Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

On the turbulent flow in piston engines: Coupling of statistical theory quantities and instantaneous turbulence

Planar particle image velocimetry (PIV) and tomographic PIV (TPIV) measurements are utilized to analyze turbulent statistical theory quantities and the instantaneous turbulence within a single-cylinder optical engine. Measurements are performed during the intake and mid-compression stroke at 800 and 1500 RPM. TPIV facilitates the evaluation of spatially resolved Reynolds stress tensor (RST) distributions, anisotropic Reynolds stress invariants, and instantaneous turbulent vortical structures. The RST analysis describes distributions of individual velocity fluctuation components that arise from unsteady turbulent flow behavior as well as cycle-to-cycle variability (CCV). A conditional analysis, for which instantaneous PIV images are sampled by their tumble center location, reveals that CCV and turbulence have similar contributions to RST distributions at the mean tumble center, but turbulence is dominant in regions peripheral to the tumble center. Analysis of the anisotropic Reynolds stress invariants reveals the spatial distribution of axisymmetric expansion, axisymmetric contraction, and 3D isotropy within the cylinder. Findings indicate that the mid-compression flow exhibits a higher tendency toward 3D isotropy than the intake flow. A novel post-processing algorithm is utilized to classify the geometry of instantaneous turbulent vortical structures and evaluate their frequency of occurrence within the cylinder. Findings are coupled with statistical theory quantities to provide a comprehensive understanding of the distribution of turbulent velocity components, the distribution of anisotropic states of turbulence, and compare the turbulent vortical flow distribution that is theoretically expected to what is experimentally observed. The analyses reveal requisites of important turbulent flow quantities and discern their sensitivity to the local flow topography and engine operation.

42 ENGINEERING↗

Examining phase separation and crystallization in glasses with X-ray nano-computed tomography

X-ray nano-computed tomography (nano-CT) is a powerful technique to characterize and visualize 3 dimensional (3D) phenomena in complex glasses at the nanoscale. This technique can offer a unique opportunity to explore the intricate morphology of multicomponent glass and glass-ceramic samples, due to its low X-ray energy and high spatial resolution (down to 50 nm). In the current demonstration paper, nano-CT provided insight into crystallization and phase separation, as well as a variety of other phenomena, including corrosion, fracture, and porosity. At scales ranging from 100 to 20 μm, the microstructures of phase separation in borosilicate, complex silicate, and chalcogenide glass compositions were examined. In addition, crystallites present in simulant nuclear waste glasses, volcanic glasses, and other related samples were explored. Nano-CT analysis can add to the understanding of (1) the formation processes, (2) distributions, interactions, and compositions of phases, and (3) the mechanisms, structures, and growth of crystallization and phase separation. Nano-CT offers wide potential in the field of glass science, especially when (1) common characterization methods are insufficient, (2) simple sample preparation is required, (3) 3D rendering is needed, or (4) compelling images of small, complex features are desired.

36 MATERIALS SCIENCE↗

Seeking regularity from irregularity: unveiling the synthesis–nanomorphology relationships of heterogeneous nanomaterials using unsupervised machine learning

Nanoscale morphology of functional materials determines their chemical and physical properties. However, despite increasing use of transmission electron microscopy (TEM) to directly image nanomorphology, it remains challenging to quantify the information embedded in TEM data sets, and to use nanomorphology to link synthesis and processing conditions to properties. We develop an automated, descriptor-free analysis workflow for TEM data that utilizes convolutional neural networks and unsupervised learning to quantify and classify nanomorphology, and thereby reveal synthesis–nanomorphology relationships in three different systems. While TEM records nanomorphology readily in two-dimensional (2D) images or three-dimensional (3D) tomograms, we advance the analysis of these images by identifying and applying a universal shape fingerprint function to characterize nanomorphology. After dimensionality reduction through principal component analysis, this function then serves as the input for morphology grouping through unsupervised learning. We demonstrate the wide applicability of our workflow to both 2D and 3D TEM data sets, and to both inorganic and organic nanomaterials, including tetrahedral gold nanoparticles mixed with irregularly shaped impurities, hybrid polymer-patched gold nanoprisms, and polyamide membranes with irregular and heterogeneous 3D crumple structures. In each of these systems, unsupervised nanomorphology grouping identifies both the diversity and the similarity of the nanomaterial across different synthesis conditions, revealing how synthetic parameters guide nanomorphology development. Our work opens possibilities for enhancing synthesis of nanomaterials through artificial intelligence and for understanding and controlling complex nanomorphology, both for 2D systems and in the far less explored case of 3D structures, such as those with embedded voids or hidden interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic super-resolution structured illumination imaging in the living brain

Cells in the brain act as components of extended networks. Therefore, to understand neurobiological processes in a physiological context, it is essential to study them in vivo. Super-resolution microscopy has spatial resolution beyond the diffraction limit, thus promising to provide structural and functional insights that are not accessible with conventional microscopy. However, to apply it to in vivo brain imaging, we must address the challenges of 3D imaging in an optically heterogeneous tissue that is constantly in motion. We optimized image acquisition and reconstruction to combat sample motion and applied adaptive optics to correcting sample-induced optical aberrations in super-resolution structured illumination microscopy (SIM) in vivo. Lastly, we imaged the brains of live zebrafish larvae and mice and observed the dynamics of dendrites and dendritic spines at nanoscale resolution.

60 APPLIED LIFE SCIENCES↗

Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis

Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 {+-} 0.44 mm (Mean {+-} STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 {+-} 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PIMS: A Lightweight Processing-in-Memory Accelerator for Stencil Computations

Stencil computation is a classic computational kernel present in many high-performance scientific applications, like image process- ing and partial differential equation solvers (PDE). A stencil compu- tation sweeps over a multi-dimensional grid and repeatedly updates values associated with points using the values from neighboring points. Stencil computations often employ large datasets that ex- ceed cache capacity, leading to excessive accesses to the memory subsystem. As such, 3D stencil computations on large grid sizes are memory-bound. In this paper we present PIMS, an in-memory accelerator for stencil computations. PIMS, implemented in the logic layer of a 3D- stacked memory, exploits the high bandwidth provided by through- silicon vias to reduce redundant memory traffic. Our comprehensive evaluation using three different grid sizes with six categories of orders indicate that the proposed architecture reduces 48.25% of data movement on average and obtains up to 65.55% of bank conflict reduction.

Li, Jie↗

Image translation for single-shot focal tomography

Focus and depth of field are conventionally addressed by adjusting longitudinal lens position. More recently, combinations of deliberate blur and computational processing have been used to extend depth of field. Here we show that dynamic control of transverse and longitudinal lens position can be used to decode focus and extend depth of field without degrading static resolution. Our results suggest that optical image stabilization systems may be used for autofocus, extended depth of field, and 3D imaging.

47 OTHER INSTRUMENTATION↗

Full-field Strain Methods for Investigating Failure Mechanisms in Triaxial Braided Composites

Composite materials made with triaxial braid architecture and large tow size carbon fibers are beginning to be used in many applications, including composite aircraft and engine structures. Recent advancements in braiding technology have led to commercially viable manufacturing approaches for making large structures with complex shape. Although the large unit cell size of these materials is an advantage for manufacturing efficiency, the fiber architecture presents some challenges for materials characterization, design, and analysis. In some cases, the static load capability of structures made using these materials has been higher than expected based on material strength properties measured using standard coupon tests. A potential problem with using standard tests methods for these materials is that the unit cell size can be an unacceptably large fraction of the specimen dimensions. More detailed investigation of deformation and failure processes in large unit cell size triaxial braid composites is needed to evaluate the applicability of standard test methods for these materials and to develop alternative testing approaches. In recent years, commercial equipment has become available that enables digital image correlation to be used on a more routine basis for investigation of full field 3D deformation in materials and structures. In this paper, some new techniques that have been developed to investigate local deformation and failure using digital image correlation techniques are presented. The methods were used to measure both local and global strains during standard straight-sided coupon tensile tests on composite materials made with 12 and 24 k yarns and a 0/+60/-60 triaxial braid architecture. Local deformation and failure within fiber bundles was observed, and this local failure had a significant effect on global stiffness and strength. The matrix material had a large effect on local damage initiation for the two matrix materials used in this investigation. Premature failure in regions of the unit cell near the edge of the straight-sided specimens was observed for transverse tensile tests in which the braid axial fibers were perpendicular to the specimen axis and the bias fibers terminated on the cut edges in the specimen gage section. This edge effect is one factor that could contribute to a measured strength that is lower than the actual material strength in a structure without edge effects.

Littell, Justin D.↗

Comparison of two different surfaces for 3d model abstraction in support of remote sensing simulations

A method for abstracting a 3D model by shrinking a triangular mesh, defined upon a best fitting ellipsoid surrounding the model, onto the model's surface has been previously described. This ''shrinkwrap'' process enables a semi-regular mesh to be defined upon an object's surface. This creates a useful data structure for conducting remote sensing simulations and image processing. However, using a best fitting ellipsoid having a graticule-based tessellation to seed the shrinkwrap process suffers from a mesh which is too dense at the poles. To achieve a more regular mesh, the use of a best fitting, subdivided icosahedron was tested. By subdividing each of the twenty facets of the icosahedron into regular triangles of a predetermined size, arbitrarily dense, highly-regular starting meshes can be created. Comparisons of the meshes resulting from these two seed surfaces are described. Use of a best fitting icosahedron-based mesh as the seed surface in the shrinkwrap process is preferable to using a best fitting ellipsoid. The impacts to remote sensing simulations, specifically generation of synthetic imagery, is illustrated.

97 MATHEMATICS AND COMPUTING↗

Enhanced copper micro/nano-particle mixed paste sintered at low temperature for 3D interconnects

An enhanced copper paste, formulated by copper micro- and nano-particles mixture, is reported to prevent paste cracking and obtain an improved packing density. The particle mixture of two different sizes enables reduction in porosity of the micro-paste and resolves the cracking issue in the nano-paste. In-situ temperature and resistance measurements indicate that the mixed paste has a lower densification temperature. Electrical study also shows a ∼12× lower sheet resistance of 0.27 Ω/sq. In addition, scanning electron microscope image analysis confirms a ∼50% lower porosity, which is consistent with the thermal and electrical results. The 3:1 (micro:nano, wt. %) mixed paste is found to have the strongest synergistic effect. This phenomenon is discussed further. Consequently, the mixed paste is a promising material for potential low temperature 3D interconnects fabrication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exploring Standing and Reflected Slow-mode Waves in Flaring Coronal Loops: A Parametric Study Using 2.5D MHD Modeling

Abstract Recent observations of reflected propagating and standing slow-mode waves in hot flaring coronal loops have spurred our investigation into their underlying excitation and damping mechanisms. To understand these processes, we conduct 2.5D magnetohydrodynamic (MHD) simulations using an arcade active region model that includes a hot and dense loop. Our simulations allow for in-depth parametric investigations complementing and expanding our previous 3D MHD modeling results. We excite these waves using a large-amplitude, flow pulse applied at one footpoint of the loop in two distinct models as motivated by observations from the Solar Dynamics Observatory/Atmospheric Imaging Assembly (SDO/AIA). The first model (Model 1) incorporates classical compressive viscosity coefficient, while the second model (Model 2) adopts a 10-times enhanced viscosity coefficient. We obtain the following major results: (1) Our 2.5D MHD simulations reinforce previous conclusions derived from 1D and 3D MHD models that significantly enhanced viscosity is crucial for the rapid excitation of standing slow waves with damping times consistent with observations by Wang et al. (2015). (2)We uncover that nonlinearity in Model 1 delays the conversion of a reflected propagating wave into a standing wave. In contrast, Model 2 exhibits a much weak influence of nonlinearity on the excitation time of standing waves, thanks to the suppression of these effects by enhanced viscosity. (3) Our results reveal that the transverse temperature structure holds more influence on wave behavior than the density structure. In Model 1, increased loop temperature contrast significantly enhances wave trapping within the structure, mitigating the impact of temperature-dependent viscous damping. Conversely, in Model 2, the impact of temperature structure on wave behavior weakens in comparison to the effect of viscosity. (4) Model 1 displays evident nonlinear coupling to the fast and kink magnetoacoustic waves and pronounced wave leakage into the corona. Model 2 exhibits significantly weaker effects in this regard. Analyzing three observed wave events by SDO/AIA aligns with Model 2 predictions, providing further support for the substantial viscosity increase. Our 2.5D study unravels the complex interplay of wave-flow phenomena and nonlinear processes in coronal loops, extending our previous 1D modeling results to incorporate more realistic loop geometry. This provides insights into scenarios where 3D effects may be neglected, thereby enhancing our understanding of the intricate dynamics of the solar corona.

Tongjiang Wang↗

WE-EF-207-02: The Rotate-Plus-Shift C-Arm Trajectory: Theory and First Clinical Results

Purpose: The proposed method enables the acquisition of a complete dataset for 3D reconstruction of C-Arm data using less than 180° rotation. Methods: Typically a C–arm cone–beam CT scan is performed using a circle–like trajectory around a region of interest. Therefore an angular range of at least 180° plus fan–angle must be covered to ensure a completely sampled data set. This fact defines some constraints on the geometry and technical specifications of a C–arm system, for example a larger C radius or a smaller C opening respectively. This is even more important for mobile C-arm devices which are typically used in surgical applications.To overcome these limitations we propose a new trajectory which requires only 180° minusfan–angle of rotation for a complete data set. The trajectory consists of three parts: A rotation of the C around a defined iso–center and two translational movements parallel to the detector plane at the begin and at the end of the rotation (rotate plus shift trajectory). This enables the acquisition of a completely sampled dataset using only 180° minus fan–angle of rotation. Results: For the evaluation of the method we show simulated and measured data. The results show, that the rotate plus shift scan yields equivalent image quality compared to the short scan which is assumed to be the gold standard for C-arm CT today. Compared to the pure rotational scan over only 165°, the rotate plus shift scan shows strong improvements in image quality. Conclusion: The proposed method makes 3D imaging using C–arms with less than 180° rotation range possible. This enables integrating full 3D functionality into a C- arm device without any loss of handling and usability for 2D imaging.

60 APPLIED LIFE SCIENCES↗

Nondestructively Visualizing and Understanding the Mechano-Electro-chemical Origins of “Soft Short” and “Creeping” in All-Solid-State Batteries

All-solid-state Li-metal batteries (ASLMBs) represent a significant breakthrough in the quest to overcome limitations associated with traditional Li-ion batteries, particularly in energy density and safety aspects. However, widespread implementation is stymied due to a lack of profound understanding of the complex mechano-electro-chemical behavior of Li metal in the ASLMBs. Herein, operando neutron imaging and X-ray computed tomography (XCT) are leveraged to nondestructively visualize Li behaviors within ASLMBs. This approach offers real-time observations of Li evolutions, both pre- and post- occurrence of a “soft short”. The coordination of 2D neutron radiography and 3D neutron tomography enables charting of the terrain of Li metal deformation operando. Concurrently, XCT offers a 3D insight into the internal structure of the battery following a “soft short”. Despite the manifestation of a “soft short”, the persistence of Faradaic processes is observed. To study the elusive “soft short”, phase field modeling is coupled with electrochemistry and solid mechanics theory. The research unravels how external pressure curbs dendrite growth, potentially leading to dendrite fractures and thus uncovering the origins of both “soft” and “hard” shorts in ASLMBs. Furthermore, by harnessing finite element modeling, it dive deeper into the mechanical deformation and the fluidity of Li metal.

25 ENERGY STORAGE↗

The Toughness of Interlocking Metasurfaces

Interlocking metasurfaces (ILMs) are arrays of autogenous latching unit cells patterned across a surface. These create structural joints similar to bioinspired suture joints but patterned over a 2D surface rather than a 1D seam. This enables ILMs to be an alternative to conventional joining technologies such as bolts, welds, and adhesives. However, compared to conventional joining methods, relatively little is known of the engineering considerations for designing structural ILMs. Herein, the interfacial toughness of an archetypal ILM is examined for the first time. Under the conditions studied here, the ILM is substantially tougher than the material from which it is made, in this case, exhibiting up to a 50% increase in interfacial crack initiation energy over the solid base material, a photocured 3D‐printed polymer. Through experimental tests using in‐situ digital image correlation along with complementary computational analyses, the mechanism of toughening in the ILM structure and the origins of toughness anisotropy are revealed. The increase in toughness is associated with cross‐cell interactions, that is, load‐sharing across unit cells, which give rise to a finite process zone length with different effective material properties. In this way, ILM toughening is analogous to crack blunting in ductile materials or fiber bridging in composites; yet here, the ILM is composed of a single‐phase base material and so the architected toughening is geometric in nature and hence amenable to future topological optimization.

fracture↗

Low dose tomographic fluoroscopy: 4D intervention guidance with running prior

Purpose: Today's standard imaging technique in interventional radiology is the single- or biplane x-ray fluoroscopy which delivers 2D projection images as a function of time (2D+T). This state-of-the-art technology, however, suffers from its projective nature and is limited by the superposition of the patient's anatomy. Temporally resolved tomographic volumes (3D+T) would significantly improve the visualization of complex structures. A continuous tomographic data acquisition, if carried out with today's technology, would yield an excessive patient dose. Recently the authors proposed a method that enables tomographic fluoroscopy at the same dose level as projective fluoroscopy which means that if scanning time of an intervention guided by projective fluoroscopy is the same as that of an intervention guided by tomographic fluoroscopy, almost the same dose is administered to the patient. The purpose of this work is to extend authors' previous work and allow for patient motion during the intervention.Methods: The authors propose the running prior technique for adaptation of a prior image. This adaptation is realized by a combination of registration and projection replacement. In a first step the prior is deformed to the current position via affine and deformable registration. Then the information from outdated projections is replaced by newly acquired projections using forward and backprojection steps. The thus adapted volume is the running prior. The proposed method is validated by simulated as well as measured data. To investigate motion during intervention a moving head phantom was simulated. Real in vivo data of a pig are acquired by a prototype CT system consisting of a flat detector and a continuously rotating clinical gantry.Results: With the running prior technique it is possible to correct for motion without additional dose. For an application in intervention guidance both steps of the running prior technique, registration and replacement, are necessary. Reconstructed volumes based on the running prior show high image quality without introducing new artifacts and the interventional materials are displayed at the correct position.Conclusions: The running prior improves the robustness of low dose 3D+T intervention guidance toward intended or unintended patient motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-204-06: Pseudo-CT Generation Using Undersampled, Single-Acquisition UTE-MDixon and Direct-Mapping Artificial Neural Networks for MR-Based Attenuation Correction and Radiation Therapy Planning

Purpose: Emerging technologies such as dedicated PET/MRI and MR-therapy systems require robust and clinically practical methods for determining photon attenuation. Herein, we propose using novel MR acquisition methods and processing for the generation of pseudo-CTs. Methods: A single acquisition, 190-second UTE-mDixon sequence with 25% (angular) sampling density and 3D radial readout was performed on nine volunteers. Three water-filled tubes were placed in the FOV for trajectory-delay correction. The MR data were reconstructed to generate three primitive images acquired at TEs of 0.1, 1.5 and 2.8 ms. In addition, three derived MR images were generated, i.e. two-point Dixon water/fat separation and R2* (1/T2*) map. Furthermore, two spatial features, i.e. local binary pattern (S-1) and relative spatial coordinates (S-2), were incorporated. A direct-mapping operator was generated using Artificial Neural Networks (ANNs) for transforming the MR features to a pseudo-CT. CT images served as the training data and, using a leave-one-out method, for performance evaluation using mean prediction deviation (MPD), mean absolute prediction deviation (MAPD), and correlation coefficient (R). Results: The errors between measured CT and pseudo-CT declined dramatically when the spatial features, i.e. S-1 and S-2, were included. The MPD, MAPD, and R were, respectively, 5±57 HU, 141±41 HU, and 0.815±0.066 for results generated by the ANN trained without the spatial features and were 32±26 HU, 115±18 HU, and 0.869±0.035 with the spatial features. The estimation errors of the pseudo-CT were smaller when both the S-1 and S-2 were used together than when either the S-1 or the S-2 was used. Pseudo-CT generation (256×256×256 voxels) by ANN took < 0.5 s using a computer having an Intel i7 3.4GHz CPU and 16 GB RAM. Conclusion: The proposed direct-mapping ANN approach is a technically accurate, clinically practical method for pseudo-CT generation and can potentially help improve the accuracy of MR-AC and MR-RTP applications. Please note that the project was completed with partial funding from the Ohio Department of Development grant TECH 11-063 and a sponsored research agreement with Philips Healthcare that is managed by Case Western Reserve University. As noted in the affiliations, some of the authors are Philips employees.

60 APPLIED LIFE SCIENCES↗

A Dual Alpha/Gamma Imaging Tool to Manage Decommissioning Operations

The knowledge of the radiological state of a nuclear plant under decommissioning is a key factor at any stage of the project: from the initial characterization (to define the best scenario and the main dismantling steps), during the monitoring of the decontamination operations, for the waste management and, last but not least, for the final controls. During a facility's operation, a clear view of the process radiological level is equally necessary, in order to plan maintenance scheduling and optimize interventions by personnel. Radiation protection teams generally ensure worker radiological safety, and also supply dose mappings for each of the areas associated with typical spectra. In most cases, this mapping does not give enough information to be used as input data when preparing maintenance or clean-up work. With advances in activity modeling calculation codes (using 3D), the way measurements are made to recover the best input radiological data on site is a key factor. Nuclear instrumentation is still in progress and the evolution of the technologies and software allow us to get imaging information in real time. The gamma camera is going to evolve and to become more compact and more sensitive. New portable gamma cameras have to be tested under high level dose rate. The alpha camera is also evolving: from the first prototype tested on site to solar blind alpha camera (to reduce the influence of light) to the new dual alpha/gamma prototype. (authors)

42 ENGINEERING↗

2D-3D registration for prostate radiation therapy based on a statistical model of transmission images

Purpose: In external beam radiation therapy of pelvic sites, patient setup errors can be quantified by registering 2D projection radiographs acquired during treatment to a 3D planning computed tomograph (CT). We present a 2D-3D registration framework based on a statistical model of the intensity values in the two imaging modalities. Methods: The model assumes that intensity values in projection radiographs are independently but not identically distributed due to the nonstationary nature of photon counting noise. Two probability distributions are considered for the intensity values: Poisson and Gaussian. Using maximum likelihood estimation, two similarity measures, maximum likelihood with a Poisson (MLP) and maximum likelihood with Gaussian (MLG), distribution are derived. Further, we investigate the merit of the model-based registration approach for data obtained with current imaging equipment and doses by comparing the performance of the similarity measures derived to that of the Pearson correlation coefficient (ICC) on accurately collected data of an anthropomorphic phantom of the pelvis and on patient data. Results: Registration accuracy was similar for all three similarity measures and surpassed current clinical requirements of 3 mm for pelvic sites. For pose determination experiments with a kilovoltage (kV) cone-beam CT (CBCT) and kV projection radiographs of the phantom in the anterior-posterior (AP) view, registration accuracies were 0.42 mm (MLP), 0.29 mm (MLG), and 0.29 mm (ICC). For kV CBCT and megavoltage (MV) AP portal images of the same phantom, registration accuracies were 1.15 mm (MLP), 0.90 mm (MLG), and 0.69 mm (ICC). Registration of a kV CT and MV AP portal images of a patient was successful in all instances. Conclusions: The results indicate that high registration accuracy is achievable with multiple methods including methods that are based on a statistical model of a 3D CT and 2D projection images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗