Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANALOG PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Digital Multicasting of Multiple Audio Streams

The Mission Control Center Voice Over Internet Protocol (MCC VOIP) system (see figure) comprises hardware and software that effect simultaneous, nearly real-time transmission of as many as 14 different audio streams to authorized listeners via the MCC intranet and/or the Internet. The original version of the MCC VOIP system was conceived to enable flight-support personnel located in offices outside a spacecraft mission control center to monitor audio loops within the mission control center. Different versions of the MCC VOIP system could be used for a variety of public and commercial purposes - for example, to enable members of the general public to monitor one or more NASA audio streams through their home computers, to enable air-traffic supervisors to monitor communication between airline pilots and air-traffic controllers in training, and to monitor conferences among brokers in a stock exchange. At the transmitting end, the audio-distribution process begins with feeding the audio signals to analog-to-digital converters. The resulting digital streams are sent through the MCC intranet, using a user datagram protocol (UDP), to a server that converts them to encrypted data packets. The encrypted data packets are then routed to the personal computers of authorized users by use of multicasting techniques. The total data-processing load on the portion of the system upstream of and including the encryption server is the total load imposed by all of the audio streams being encoded, regardless of the number of the listeners or the number of streams being monitored concurrently by the listeners. The personal computer of a user authorized to listen is equipped with special- purpose MCC audio-player software. When the user launches the program, the user is prompted to provide identification and a password. In one of two access- control provisions, the program is hard-coded to validate the user s identity and password against a list maintained on a domain-controller computer at the MCC. In the other access-control provision, the program verifies that the user is authorized to have access to the audio streams. Once both access-control checks are completed, the audio software presents a graphical display that includes audiostream-selection buttons and volume-control sliders. The user can select all or any subset of the available audio streams and can adjust the volume of each stream independently of that of the other streams. The audio-player program spawns a "read" process for the selected stream(s). The spawned process sends, to the router(s), a "multicast-join" request for the selected streams. The router(s) responds to the request by sending the encrypted multicast packets to the spawned process. The spawned process receives the encrypted multicast packets and sends a decryption packet to audio-driver software. As the volume or muting features are changed by the user, interrupts are sent to the spawned process to change the corresponding attributes sent to the audio-driver software. The total latency of this system - that is, the total time from the origination of the audio signals to generation of sound at a listener s computer - lies between four and six seconds.

Macha, Mitchell↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Time-tagging data acquisition system for testing superconducting electronics based on an RFSoC and custom analog frontend

Novel electronic devices can often be operated in a plethoraof ways, which makes testing circuits comprised of them difficult.Often, no single tool can simultaneously analyze the operatingmargins, maximum speed, and failure modes of a circuit, particularlywhen the intended behavior of subcomponents of the circuit is notstandardized. This work demonstrates a cost-effective time-domaindata acquisition system for electronic circuits that enables moreintricate verification techniques than are practical withconventional experimental setups. We use high-speeddigital-to-analog converters and real-timemulti-gigasample-per-second waveform processing to push experimentalcircuits beyond their maximum operating speed. Our customtime-tagging data capture firmware reduces memory requirements andcan be used to determine when errors occur. The firmware iscombined with a thermal-noise-limited analog frontend with50 dB of dynamic range. Compared to currentlyavailable commercial test equipment that is seven times moreexpensive, this data acquisition system was able to operate asuperconducting shift register at a nearly three-times-higher clockfrequency (200 MHz vs. 80 MHz).

Foster, Reed A. [MIT] (ORCID:0000000231002127)↗

Human Factors for Advanced Reactors

Existing light water reactors in the U.S. are primarily large baseload electricity generating facilities. The concept of operations for these plants remains largely unchanged since the advent of commercial nuclear power—the main control room serves as the hub of plant activities and is staffed with multiple licensed operators who work in tandem under the shift supervisor, and staff such as field workers support the control room remotely. While newer plants have brought the advent of digital human-machine interfaces to replace earlier analog and mechanical instrumentation and controls, much of the control process remains unchanged and manual. It is simply a newer version of legacy concepts. Advanced reactors potentially bring considerable changes to the size, fuel type, automation, and staffing of nuclear power plants, necessitating a fundamental shift not just from analog to digital, but further from human to automation, from onsite to remote, from control to monitoring, and from many to few operators. Despite this multitude of parallel evolutions in reactor designs, many of the vendors developing the next generation of reactors represent smaller research and development enterprises. It is therefore not feasible to address all aspects of plant design at the same time. In particular, the competing design aspects of new reactors present a significant challenge to the development of robust and human factored systems at the plant. As vendors develop new reactor designs, much of the early focus is naturally on the fuel and reactor system technology. Looming behind these early advances is the daunting prospect of first-of-a-kind control concepts that have not yet been developed or validated. A failure to address the human element of reactor design early will lead to missed opportunities. The quickest development process is the replication of existing concepts of operations at legacy plants, even when such systems were long ago surpassed by better human-machine technologies outside the nuclear industry. Conversely, attempting to undertake novel concepts of operations late in the design life cycle of a plant could result in protracted development efforts and delays in licensing and deployment. This does not have to happen, and it is imperative that human factors be considered now, early in the design of new reactors.

99 GENERAL AND MISCELLANEOUS↗

Optical processing for distributed sensors in control of flexible spacecraft

A recent potential of distributed image processing is discussed. Applications in the control of flexible spacecraft are emphasized. Devices are currently being developed at NASA and in universities and industries that allow the real-time processing of holographic images. Within 5 years, it is expected that, in real-time, one may add or subtract holographic images at optical accuracy. Images are stored and processed in crystal mediums. The accuracy of their storage and processing is dictated by the grating level of laser holograms. It is far greater than that achievable using current analog-to-digital, pixel oriented, image digitizing and computing techniques. Processors using image processing algebra can conceptually be designed to mechanize Fourier transforms, least square lattice filters, and other complex control system operations. Thus, actuator command inputs derived from complex control laws involving distributed holographic images can be generated by such an image processor. Plans are revealed for the development of a Conjugate Optics Processor for control of a flexible object.

Montgomery, Raymond C.↗

Astromaterials Research Office (KR) Overview

The fundamental goal of our research is to understand the origin and evolution of the solar system, particularly the terrestrial, "rocky" bodies. Our research involves analysis of, and experiments on, astromaterials in order to understand their nature, sources, and processes of formation. Our state-of-the-art analytical laboratories include four electron microbeam laboratories for mineral analysis, four spectroscopy laboratories for chemical and mineralogical analysis, and four mass spectrometry laboratories for isotopic analysis. Other facilities include the experimental impact laboratory and both 1-atm gas mixing and high-pressure experimental petrology laboratories. Recent research has emphasized a diverse range of topics, including: Study of the solar system's primitive materials, such as carbonaceous chondrites and interplanetary dust; Study of early solar system chronology using short-lived radioisotopes and early nebular processes through detailed geochemical and isotopic characterizations; Study of large-scale planetary differentiation and evolution via siderophile and incompatible trace element partitioning, magma ocean crystallization simulations, and isotopic systematics; Study of the petrogenesis of Martian meteorites through petrographic, isotopic, chemical, and experimental melting and crystallization studies; Interpretation of remote sensing data, especially from current robotic lunar and Mars missions, and study of terrestrial analog materials; Study of the role of organic geochemical processes in the evolution of astromaterials and the extent to which they constrain the potential for habitability and the origin of life.

Draper, David S.↗

Universal signal conditioning amplifier

A state-of-the-art instrumentation amplifier capable of being used with most types of transducers has been developed at the Kennedy Space Center. This Universal Signal Conditioning Amplifier (USCA) can eliminate costly measurement setup item and troubleshooting, improve system reliability and provide more accurate data than conventional amplifiers. The USCA can configure itself for maximum resolution and accuracy based on information read from a RAM chip attached to each transducer. Excitation voltages or current are also automatically configured. The amplifier uses both analog and digital state-of-the-art technology with analog-to-digital conversion performed in the early stages in order to minimize errors introduced by offset and gain drifts in the analog components. A dynamic temperature compensation scheme has been designed to achieve and maintain 12-bit accuracy of the amplifier from 0 to 70 C. The digital signal processing section allows the implementation of digital filters up to 511th order. The amplifier can also perform real-time linearizations up to fourth order while processing data at a rate of 23.438 kS/s. Both digital and analog outputs are available from the amplifier.

Medelius, Pedro J.↗

Design and Performance of the Astro-E/XRS Signal Processing System

We describe the signal processing system of the Astro-E XRS Instrument. The Calorimeter Analog Processor (CAP) provides bias and power for the detectors and amplifies the detector signals by a factor of 20,000. The Calorimeter Digital Processor (CDP) performs the digital processing of the calorimeter signals, detecting X-ray pulses and analyzing them by optimal filtering. We describe the operation of pulse detection, pulse height analysis, and risetime determination. We also discuss performance, including the three event grades (hi-res, mid-res, and low-res), anticoincidence detection, counting rate dependence, and noise rejection.

Boyce, K. R.↗

The Design and Performance of the Astro-E/XRS Signal Processing System

We describe the signal processing system of the Astro-E XRS instrument. The Calorimeter Analog Processor (CAP) provides bias and power for the detectors and amplifies the detector signals by a factor of 20,000. The Calorimeter Digital Processor (CDP) performs the digital processing of the calorimeter signals, detecting X-ray pulses and analyzing them by optimal filtering. We describe the operation of pulse detection, pulse height analysis, and risetime determination. We also discuss performance, including the three event grades (hi-res, mid-res, and low-res), anticoincidence detection, counting rate dependence, and noise rejection.

Boyce, K. R.↗

Design and Performance of the Astro-E/XRS Signal Processing System

We describe the signal processing system of the Astro-E XRS instrument. The Calorimeter Analog Processor (CAP) provides bias and power for the detectors and amplifies the detector signals by a factor of 20,000. The Calorimeter Digital Processor (CDP) performs the digital processing of the calorimeter signals, detecting X-ray pulses and analyzing them by optimal filtering. We describe the operation of pulse detection, Pulse height analysis. and risetime determination. We also discuss performance, including the three event grades (hi-res mid-res, and low-res). anticoincidence detection, counting rate dependence, and noise rejection.

Boyce, Kevin R.↗

Analog Module Architecture for Space-Qualified Field-Programmable Mixed-Signal Arrays

Spacecraft require all manner of both digital and analog circuits. Onboard digital systems are constructed almost exclusively from field-programmable gate array (FPGA) circuits providing numerous advantages over discrete design including high integration density, high reliability, fast turn-around design cycle time, lower mass, volume, and power consumption, and lower parts acquisition and flight qualification costs. Analog and mixed-signal circuits perform tasks ranging from housekeeping to signal conditioning and processing. These circuits are painstakingly designed and built using discrete components due to a lack of options for field-programmability. FPAA (Field-Programmable Analog Array) and FPMA (Field-Programmable Mixed-signal Array) parts exist but not in radiation-tolerant technology and not necessarily in an architecture optimal for the design of analog circuits for spaceflight applications. This paper outlines an architecture proposed for an FPAA fabricated in an existing commercial digital CMOS process used to make radiation-tolerant antifuse-based FPGA devices. The primary concerns are the impact of the technology and the overall array architecture on the flexibility of programming, the bandwidth available for high-speed analog circuits, and the accuracy of the components for high-performance applications.

Edwards, R. Timothy↗

A Note on Truncated Long-Range Percolation with Heavy Tails on Oriented Graphs

We consider oriented long-range percolation on a graph with vertex set ℤ{sup d}×ℤ{sub +} and directed edges of the form 〈(x,t),(x+y,t+1)〉, for x, y in ℤ{sup d} and t∈ℤ{sub +}. Any edge of this form is open with probability p{sub y}, independently for all edges. Under the assumption that the values p{sub y} do not vanish at infinity, we show that there is percolation even if all edges of length more than k are deleted, for k large enough. We also state the analogous result for a long-range contact process on ℤ{sup d}.

97 MATHEMATICS AND COMPUTING↗

Comparison of analog and digital pulse-shape-discrimination systems

Pulse shape discrimination (PSD) performance of two optimized PSD systems (one digital and one analog) is compared in this work. One system uses digital charge integration, while the other system uses analog zero crossing. Measurements were conducted with each PSD system using the CAEN V1720 (250 MHz) data acquisition system. An organic-liquid scintillator, coupled to a photo-multiplier tube, was used to detect neutrons and gamma rays from a Cf-252 spontaneous-fission source. The PSD perfor-mance of both systems was optimized and quantified using a traditional figure-of-merit (FOM) approach. FOM's were found for three, 300 keVee light-output bins, spanning from 100 to 1000 keVee, and one larger bin from 100 to 1800 keVee. Digital PSD outperformed analog PSD in the lowest light-output bin by approximately 50%, and by 11% for the highest light-output bin.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Injection Locking Techniques for Spectrum Analysis

Wideband spectrum analysis supports future communication systems that reconfigure and adapt to the capacity of the spectral environment. While test equipment manufacturers offer wideband spectrum analyzers with excellent sensitivity and resolution, these spectrum analyzers typically cannot offer acceptable size, weight, and power (SWAP). CMOS integrated circuits offer the potential to fully integrate spectrum analysis capability with analog front-end circuitry and digital signal processing on a single chip. Unfortunately, CMOS lacks high-Q passives and wideband resonator tunability that is necessary for heterodyne implementations of spectrum analyzers. As an alternative to the heterodyne receiver architectures, two nonlinear methods for performing wideband, low-power spectrum analysis are presented. The first method involves injecting the spectrum of interest into an array of injection-locked oscillators. The second method employs the closed loop dynamics of both injection locking and phase locking to independently estimate the injected frequency and power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality assurance test of silicon photomultipliers and electronic boards for STAR event plane detector

The event plane detector (EPD), installed in the Solenoid Tracker at the Relativistic Heavy-Ion Collider located at the Brookhaven National Laboratory is a plastic scintillator-based device that measures the reaction centrality and event plane in the forward region of the relativistic heavy-ion collisions. We used silicon photomultiplier (SiPM) arrays to detect the photons produced in the scintillator via the fiber connection. Signals from the SiPM arrays were amplified by the front-end electronic (FEE) board, and sent to the analog-to-digital converter (ADC) boards for further processing via the receiver (RX) board. The full EPD system consisted of 24 super-sectors (SSs); each SS was equipped with two SiPM boards, two FEE boards and two RX boards, and they corresponded to 744 readout channels. All these boards were mass produced at the University of Science and Technology of China, with a dedicated quality assurance (QA) procedures applied to identify any problems before deployment. This article describes the details of the QA method and the related test system. As a result, the QA test results are presented along with the discussions.

EPD↗

Information-Guided Dynamic Nuclear Polarization

A spin ensemble in thermal equilibrium continuously undergoes random fluctuations analogous to those observed in Brownian motion, a process known as spin noise. Here, we investigate the dynamics of a system comprising a spin-1 paramagnetic center and a hyperfine-coupled spin-1/2 nucleus in the vicinity of a level crossing. We theoretically show that nuclear spins polarize efficiently under the combined action of thermal fluctuations and a closed-loop feedback protocol. The latter articulates periodic observations of the electronic magnetization and radio-frequency pulses connecting hybrid states with opposite nuclear spin alignment. Since nuclear polarization emerges from electronic spin fluctuations, not spin order, this microwave-free technique generically benefits from warmer, not colder, operation temperatures. Furthermore, because the spin dynamics at play near a level crossing is rather insensitive to the absolute value of the magnetic field, our work promises opportunities for high-field dynamic nuclear polarization, which is difficult to attain through present methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Energy Collision of Quarks and Mesons in the Schwinger Model: From Tensor Networks to Circuit QED

With the aim of studying nonperturbative out-of-equilibrium dynamics of high-energy particle collisions on quantum simulators, we investigate the scattering dynamics of lattice quantum electrodynamics in 1 + 1 dimensions. Working in the bosonized formulation of the model and in the thermodynamic limit, we use uniform-matrix-product-state tensor networks to construct multiparticle wave-packet states, evolve them in time, and detect outgoing particles post collision. This facilitates the numerical simulation of scattering experiments in both confined and deconfined regimes of the model at different energies, giving rise to rich phenomenology, including inelastic production of quark and meson states, meson disintegration, and dynamical string formation and breaking. We obtain elastic and inelastic scattering cross sections, together with time-resolved momentum and position distributions of the outgoing particles. Furthermore, we propose an analog circuit-QED implementation of the scattering process that is native to the platform, requires minimal ingredients and approximations, and enables practical schemes for particle wave-packet preparation and evolution. Furthermore, this study highlights the role of classical and quantum simulation in enhancing our understanding of scattering processes in quantum field theories in real time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implementation of a Readout Circuit on SOI Technology for the Signal Conditioning of a Neutron Detector in Harsh Environment

A transistor level implementation of the analog block of a readout system on SOI process is presented here. This system is dedicated to the signal conditioning of a neutron detector in harsh environment. The different parts of the readout circuits are defined. The harsh environment constraints (crossing particle effect, high temperatures) are also detailed and modeled in the circuit in order to test and evaluate the characteristics of the designed block when working under these conditions. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗