Search NASA⌕ Search

SEARCH · Search NASA

Results for “APPEALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Comparison of signal to noise ratios from spatial and frequency domain formulations of nonprewhitening model observers in digital mammography

Purpose: Image quality indices based upon model observers are promising alternatives to laborious human readings of contrast-detail images. This is especially appealing in digital mammography as limiting values for contrast thresholds determine, according to some international protocols, the acceptability of these systems in the radiological practice. The objective of the present study was to compare the signal to noise ratios (SNR) obtained with two nonprewhitening matched filter model observer approaches, one in the spatial domain and the other in the frequency domain, and with both of them worked out for disks as present in the CDMAM phantom. Methods: The analysis was performed using images acquired with the Siemens Novation and Inspiration digital mammography systems. The spatial domain formulation uses a series of high dose CDMAM images as the signal and a routine exposure of two flood images to calculate the covariance matrix. The frequency domain approach uses the mathematical description of a disk and modulation transfer function (MTF) and noise power spectrum (NPS) calculated from images. Results: For both systems most of the SNR values calculated in the frequency domain were in very good agreement with the SNR values calculated in the spatial domain. Both the formulations in the frequency domain and in the spatial domain show a linear relationship between SNR and the diameter of the CDMAM discs. Conclusions: The results suggest that both formulations of the model observer lead to very similar figures of merit. This is a step forward in the adoption of figures of merit based on NPS and MTF for the acceptance testing of mammography systems.

60 APPLIED LIFE SCIENCES↗

Heel effect adaptive flat field correction of digital x-ray detectors

Purpose: Anode heel effect renders large-scale background nonuniformities in digital radiographs. Conventional offset/gain calibration is performed at mono source-to-image distance (SID), and disregards the SID-dependent characteristic of heel effect. It results in a residual nonuniform background in the corrected radiographs when the SID settings for calibration and correction differ. In this work, the authors develop a robust and efficient computational method for digital x-ray detector gain correction adapted to SID-variant heel effect, without resorting to physical filters, phantoms, complicated heel effect models, or multiple-SID calibration and interpolation.Methods: The authors present the Duo-SID projection correction method. In our approach, conventional offset/gain calibrations are performed only twice, at the minimum and maximum SIDs of the system in typical clinical use. A fast iterative separation algorithm is devised to extract the detector gain and basis heel patterns from the min/max SID calibrations. The resultant detector gain is independent of SID, while the basis heel patterns are parameterized by the min- and max-SID. The heel pattern at any SID is obtained from the min-SID basis heel pattern via projection imaging principles. The system gain desired at a specific acquisition SID is then constructed using the projected heel pattern and detector gain map.Results: The method was evaluated for flat field and anatomical phantom image corrections. It demonstrated promising improvements over interpolation and conventional gain calibration/correction methods, lowering their correction errors by approximately 70% and 80%, respectively. The separation algorithm was able to extract the detector gain and heel patterns with less than 2% error, and the Duo-SID corrected images showed perceptually appealing uniform background across the detector.Conclusions: The Duo-SID correction method has substantially improved on conventional offset/gain corrections for digital x-ray imaging in an SID-variant environment. The technique is relatively simple, and can be easily incorporated into multiple-point gain calibration/correction techniques. It offers a potentially valuable tool for preprocessing digital x-ray images to boost image quality of mammography, chest and cardiac radiography, as well as automated computer aided diagnostic radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimating nonrigid motion from inconsistent intensity with robust shape features

Purpose: To develop a nonrigid motion estimation method that is robust to heterogeneous intensity inconsistencies amongst the image pairs or image sequence. Methods: Intensity and contrast variations, as in dynamic contrast enhanced magnetic resonance imaging, present a considerable challenge to registration methods based on general discrepancy metrics. In this study, the authors propose and validate a novel method that is robust to such variations by utilizing shape features. The geometry of interest (GOI) is represented with a flexible zero level set, segmented via well-behaved regularized optimization. The optimization energy drives the zero level set to high image gradient regions, and regularizes it with area and curvature priors. The resulting shape exhibits high consistency even in the presence of intensity or contrast variations. Subsequently, a multiscale nonrigid registration is performed to seek a regular deformation field that minimizes shape discrepancy in the vicinity of GOIs. Results: To establish the working principle, realistic 2D and 3D images were subject to simulated nonrigid motion and synthetic intensity variations, so as to enable quantitative evaluation of registration performance. The proposed method was benchmarked against three alternative registration approaches, specifically, optical flow, B-spline based mutual information, and multimodality demons. When intensity consistency was satisfied, all methods had comparable registration accuracy for the GOIs. When intensities among registration pairs were inconsistent, however, the proposed method yielded pronounced improvement in registration accuracy, with an approximate fivefold reduction in mean absolute error (MAE = 2.25 mm, SD = 0.98 mm), compared to optical flow (MAE = 9.23 mm, SD = 5.36 mm), B-spline based mutual information (MAE = 9.57 mm, SD = 8.74 mm) and mutimodality demons (MAE = 10.07 mm, SD = 4.03 mm). Applying the proposed method on a real MR image sequence also provided qualitatively appealing results, demonstrating good feasibility and applicability of the proposed method. Conclusions: The authors have developed a novel method to estimate the nonrigid motion of GOIs in the presence of spatial intensity and contrast variations, taking advantage of robust shape features. Quantitative analysis and qualitative evaluation demonstrated good promise of the proposed method. Further clinical assessment and validation is being performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Group 176

The dosimetric impact from devices external to the patient is a complex combination of increased skin dose, reduced tumor dose, and altered dose distribution. Although small monitor unit or dose corrections are routinely made for blocking trays, ion chamber correction factors, e.g., accounting for temperature and pressure, or tissue inhomogeneities, the dose perturbation of the treatment couch top or immobilization devices is often overlooked. These devices also increase skin dose, an effect which is also often ignored or underestimated. These concerns have grown recently due to the increased use of monolithic carbon fiber couch tops which are optimal for imaging for patient position verification but cause attenuation and increased skin dose compared to the “tennis racket” style couch top they often replace. Also, arc delivery techniques have replaced stationary gantry techniques which cause a greater fraction of the dose to be delivered from posterior angles. A host of immobilization devices are available and used to increase patient positioning reproducibility, and these also have attenuation and skin dose implications which are often ignored. This report of Task Group 176 serves to present a survey of published data that illustrates the magnitude of the dosimetric effects of a wide range of devices external to the patient. The report also provides methods for modeling couch tops in treatment planning systems so the physicist can accurately compute the dosimetric effects for indexed patient treatments. Both photon and proton beams are considered. A discussion on avoidance of high density structures during beam planning is also provided. An important aspect of this report are the recommendations the authors make to clinical physicists, treatment planning system vendors, and device vendors on how to make measurements of surface dose and attenuation and how to report these values. For the vendors, an appeal is made to work together to provide accurate couch top models in planning systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-256: Optimizing the Combination of Targeted Radionuclide Therapy Agents Using a Multi-Scale Patient-Specific Monte Carlo Dosimetry Platform

Purpose: Combination targeted radionuclide therapy (TRT) is appealing because it can potentially exploit different mechanisms of action from multiple radionuclides as well as the variable dose rates due to the different radionuclide half-lives. The work describes the development of a multiobjective optimization algorithm to calculate the optimal ratio of radionuclide injection activities for delivery of combination TRT. Methods: The ‘diapeutic’ (diagnostic and therapeutic) agent, CLR1404, was used as a proof-of-principle compound in this work. Isosteric iodine substitution in CLR1404 creates a molecular imaging agent when labeled with I-124 or a targeted radiotherapeutic agent when labeled with I-125 or I-131. PET/CT images of high grade glioma patients were acquired at 4.5, 24, and 48 hours post injection of 124I-CLR1404. The therapeutic 131I-CLR1404 and 125ICLR1404 absorbed dose (AD) and biological effective dose (BED) were calculated for each patient using a patient-specific Monte Carlo dosimetry platform. The optimal ratio of injection activities for each radionuclide was calculated with a multi-objective optimization algorithm using the weighted sum method. Objective functions such as the tumor dose heterogeneity and the ratio of the normal tissue to tumor doses were minimized and the relative importance weights of each optimization function were varied. Results: For each optimization function, the program outputs a Pareto surface map representing all possible combinations of radionuclide injection activities so that values that minimize the objective function can be visualized. A Pareto surface map of the weighted sum given a set of user-specified importance weights is also displayed. Additionally, the ratio of optimal injection activities as a function of the all possible importance weights is generated so that the user can select the optimal ratio based on the desired weights. Conclusion: Multi-objective optimization of radionuclide injection activities can provide an invaluable tool for maximizing the dosimetric benefits in multi-radionuclide combination TRT. BT, JG, and JW are affiliated with Cellectar Biosciences which owns the licensing rights to CLR1404 and related compounds.

60 APPLIED LIFE SCIENCES↗

SU-E-T-537: Comparison of Intra-Operative Soft X-Rays to Low Energy Electron Beams for Treatment of Superficial Lesions

Purpose: Superficial soft x-ray applicators have recently been designed for use with existing intra-operative radiotherapy systems. These applicators may be used in treating superficial lesions which are conventionally treated with electron beams. The purpose of this abstract is to compare dose distributions of an intra-operative 50kV x-ray unit with low energy electrons for the treatment of superficial lesions. Methods: Dosimetric parameters for 1 and 3-cm diameter Intrabeam superficial x-ray applicators were measured with EBT3 Gafchromic film in a solid water phantom. Depth dose distributions and profiles (d=2, 5, 10 and 15mm) were obtained by prescribing a dose of 400cGy at 5mm depth below the phantom surface. Corresponding dose profiles for 6-MeV electrons were acquired from a Varian Clinac 21EX at 100 SSD. H and D calibration curves were generated for each modality for 0-800cGy. Results: Dose coverage, penumbra, dose uniformity, surface dose, and dose fall-off were examined. Compared to electrons, Intrabeam lateral dose coverage at 5mm depth was 70% larger with a much sharper (1/4) penumbra. Electron isodose levels bulged with depth, whereas Intrabeam isodose levels exhibited a convex cone shape. The Intrabeam dose profiles demonstrated horns in the dose distribution up to a 5mm depth and an exponential dose fall-off. Relative surface dose was higher for the Intrabeam applicators. Treatment times were comparable for both modalities. Conclusions: The very small penumbra of Intrabeam at shallow depths could be useful in treating superficial lesions adjacent to critical structures. The exponential dose fall-off of Intrabeam makes it appealing in the sparing of structures beyond the lesion. However, for lesions past a depth of 5mm, electrons would be desirable as they penetrate farther and provide skin sparing. Intrabeam may be preferable for sites that are difficult to treat with electrons due to mechanical and physical limitations.

07 ISOTOPE AND RADIATION SOURCES↗

TU-D-9A-01: TG176: Dosimetric Effects of Couch Tops and Immobilization Devices

The dosimetric impact from devices external to the patient is a complex combination of increased skin dose, reduced tumor dose, and altered dose distribution. Although small monitor unit or dose corrections are routinely made for blocking trays, ion chamber correction factors, or tissue inhomogeneities, the dose perturbation of the treatment couch top or immobilization devices are often overlooked. These devices also increase surface dose, an effect which is also often ignored or underestimated. These concerns have grown recently due to the increased use of monolithic carbon fiber couch tops which are optimal for imaging for patient position verification but cause attenuation and increased surface dose compared to the ‘tennis racket’ style couch top they often replace. Also, arc delivery techniques have replaced stationary gantry techniques which cause a greater fraction of the dose to be delivered from posterior angles. A host of immobilization devices are available and used to increase patient positioning reproducibility, and these also have attenuation and skin dose implications which are often ignored. This report of Task Group 176 serves to present a survey of published data that illustrates the magnitude of the dosimetric effects of a wide range of devices external to the patient. The report also provides methods for modeling couch tops in treatment planning systems so the physicist can accurately compute the dosimetric effects for indexed patient treatments. Both photon and proton beams are considered. A discussion on avoidance of high density structures during beam planning is also provided. An important aspect of this report are the recommendations we make to clinical physicists, treatment planning system vendors, and device vendors on how to make measurements of skin dose and attenuation, how to report these values, and for the vendors, an appeal is made to work together to provide accurate couch top models in planning systems. Learning Objectives: What are the dosimetric effects of couch tops What are the dosimetric effects of immobilization devices How can one model couch tops in the treatment planning system How can one measure attenuation and surface dose changes due to external devices.

60 APPLIED LIFE SCIENCES↗

SU-D-304-03: Small Field Proton Dosimetry Using MicroDiamond and Gafchromic Film

Purpose: Certain dosimetric characteristics continue to make proton beam therapy an appealing modality for cancer treatment. The proton Bragg peak allows for conformal radiation dose delivery to the target while reducing dose to normal tissue and organs. As field sizes become very small the benefit of the Bragg peak is diminished due to loss of transverse equilibrium along the central beam axis. Furthermore, aperture scattering contributes additional dose along the central axis. These factors warrant the need for accurate small field dosimetry. In this study small field dosimetry was performed using two different methods. Methods: Small field dosimetry measurements were performed using a PTW microdiamond detector and Gafchromic EBT2 film for aperture sizes ranging from 0.5cm to 10cm and a proton range in water of 10cm to 27cm. The measurements were analyzed and then compared to each other and to reference dosimetry data acquired with a Markus chamber. Results: A decrease in normalized output is observed at small field sizes and at larger ranges in water using both measurement methods. Also, a large variation is observed between the output measurements by microdiamond and film at very small field sizes. At the smallest aperture, normalized output ranged from 0.16 to 0.72 and the percent difference between both measurement methods ranged from 36% to 70% depending on proton range. At field sizes above 5cm the film and microdiamond agree within 3%. Conclusion: Although both measurement methods exhibit a general decrease in output factor at small field sizes, dosimetric measurements for small fields using these two methods can vary significantly. Dosimetry under standard conditions is not sufficient to correctly model the dose distributions and outputs factors for small field sizes, additional small field measurements should be performed.

60 APPLIED LIFE SCIENCES↗

TU-EF-304-05: Anterior Proton Beams for Prostate Treatments Lead to Substantial Elevations in Modeled RBE-Weighted Rectal Dose

Purpose: If a constant RBE of 1.1 is assumed, range-verified anterior oblique (AO) proton beams appear to offer the potential to reduce the mean dose delivered to the rectum, anterior rectal wall and penile bulb by a factor of ∼2 relative to standard bilateral (SB) proton beam arrangements. Additionally, AO proton beams targeted at the prostate avoid the femoral heads and so form a particularly appealing option for patients with hip prostheses. This study investigates LET enhancement at the distal edge of AO SOBPs, applying RBE models to consider the extent to which AO beams lead to hotspots in rectum biological dose. Methods: Eight patients were selected, all treated with passively scattered, SB proton beams to 79.2Gy(E) within the prostate and 50.4Gy(E) within the proximal 5–15mm of seminal vesicles. Additional plans utilizing AO beams (±35°) were created in XiO (Elekta) assuming a fixed RBE of 1.1. Voxelised dose and LET distributions were calculated using Monte Carlo (TOPAS). Three different LET/RBE models were applied (Carabe 2012, Wedenberg 2013, McNamara 2015). Results: Across the eight patients, the mean LET within the rectal wall was found to be 3.5(3.2–4.0)keV/µm for the SB plans compared to 10.5(8.6–13.0)keV/µm for the AO plans. Application of the median LET/RBE model to the AO plans, rather than a fixed RBE of 1.1, resulted in an increase of 13.6(11.9–14.7)GyRBE in maximum rectal wall (1cc) RBEw dose, leading to values of 90.4(90.0–91.3)GyRBE. Conclusion: relative to SB proton beams, AO proton beams exhibit substantially increased mean LET values within the rectal wall. For the passively scattered AO beams, modeling indicates that this enhancement is likely to translate into unacceptable RBEw dose hotspots. Whilst no RBE- LET model has yet been fully validated in-vivo, caution must be applied if AO beams are to be considered for prostate patients.

60 APPLIED LIFE SCIENCES↗

Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries

Purpose: The in vivo 3D dose delivered to a patient during volumetric modulated arc therapy (VMAT) delivery can be calculated using electronic portal imaging device (EPID) images. These images must be acquired in cine-mode (i.e., “movie” mode) in order to capture the time-dependent delivery information. The angle subtended by each cine-mode EPID image during an arc can be changed via the frame averaging number selected within the image acquisition software. A large frame average number will decrease the EPID’s angular resolution and will result in a decrease in the accuracy of the dose information contained within each image. Alternatively, less EPID images acquired per delivery will decrease the overall 3D patient dose calculation time, which is appealing for large-scale clinical implementation. Therefore, the purpose of this study was to determine the optimal frame average value per EPID image, defined as the highest frame averaging that can be used without an appreciable loss in 3D dose reconstruction accuracy for VMAT treatments. Methods: Six different VMAT plans and six different SBRT-VMAT plans were delivered to an anthropomorphic phantom. Delivery was carried out on a Varian 2300ix model linear accelerator (Linac) equipped with an aS1000 EPID running at a frame acquisition rate of 7.5 Hz. An additional PC was set up at the Linac console area, equipped with specialized frame-grabber hardware and software packages allowing continuous acquisition of all EPID frames during delivery. Frames were averaged into “frame-averaged” EPID images using MATLAB. Each frame-averaged data set was used to calculate the in vivo dose to the patient and then compared to the single EPID frame in vivo dose calculation (the single frame calculation represents the highest possible angular resolution per EPID image). A mean percentage dose difference of low dose (<20% prescription dose) and high dose regions (>80% prescription dose) was calculated for each frame averaged scenario for each plan. The authors defined their unacceptable loss of accuracy as no more than a ±1% mean dose difference in the high dose region. Optimal frame average numbers were then determined as a function of the Linac’s average gantry speed and the dose per fraction. Results: The authors found that 9 and 11 frame averages were suitable for all VMAT and SBRT-VMAT treatments, respectively. This resulted in no more than a 1% loss to any of the dose region’s mean percentage difference when compared to the single frame reconstruction. The optimized number was dependent on the treatment’s dose per fraction and was determined to be as high as 14 for 12 Gy/fraction (fx), 15 for 8 Gy/fx, 11 for 6 Gy/fx, and 9 for 2 Gy/fx. Conclusions: The authors have determined an optimal EPID frame averaging number for multiple VMAT-type treatments. These are given as a function of the dose per fraction and average gantry speed. These optimized values are now used in the authors’ clinical, 3D, in vivo patient dosimetry program. This provides a reduction in calculation time while maintaining the authors’ required level of accuracy in the dose reconstruction.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-179: Fast and Accurate Profile Acquisition for Proton Beam Using Multi-Ion Chamber Arrays

Purpose: Proton beam profile measurement is more time-consuming than photon beam. Due to the energy modulation during proton delivery, chambers have to move step-by-step instead of continuously. Multi-ion chamber arrays are appealing to this task since multiple measurements can be performed at once. However, their utilization suffers from sparse spatial resolution and potential intrinsic volume-averaging effect of the disk-shaped ion chambers. We proposed an approach to measure proton beam profiles accurately and efficiently. Methods: Mevion S250 proton system and IBA Matrixx ion chamber arrays were used in this study. Matrixx has interchamber distance of 7.62 mm, and chamber diameter of 4.5 mm. We measured the same beam profile by moving the Matrixx seven times with 1 mm each time along y axis. All 7 measurements were superimposed to get a “finer” profile with 1 mm spatial resolution. Coarser resolution profiles of 2 mm and 3 mm were also generated by using subsets of measurements. Those profiles were compared to the TPS calculated beam profile. Gamma analysis was performed for 2D dose maps to evaluate the difference to TPS dose plane. Results: Preliminary results showed a large discrepancy between the TPS calculated profile and the single measurement profile with 7.6 mm resolution. A good match could be achieved when the resolution reduced to 3 mm by adding one extra measurement. Gamma analysis for 2D dose map of a 10×10 field showed a passing rate (γ ≤ 1) of 90.6% using a 3% and 3mm criterion for single measurement, which increased to 92.3% for 2-measurement superimposition, and slightly further increased to 92.9% for 7-measurement superimposition. Conclusion: The results indicated that 2 measurements shifted by 3mm using Matrixx generated a smooth proton beam profile with good matching to Eclipse beam profile. We suggest using this 2-measurement approach in clinic for double scattering proton beam profile measurement.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-JeP3-02: Automated Dose Accumulation and Dose Accuracy Assessment for Online Or Offline Adaptive Replanning

Purpose: With introduction of high-quality treatment imaging during radiation therapy (RT) delivery, e.g., MR-Linac, adaptive replanning of either online or offline becomes appealing. Dose accumulation of delivered fractions, a prerequisite for the adaptive replanning, can be cumbersome and inaccurate. The purpose of this work is to develop an automated process to accumulate daily doses and to assess the dose accumulation accuracy voxel-by-voxel for adaptive replanning. Methods: The process includes the following main steps: 1) reconstructing daily dose for each delivered fraction with a treatment planning system (Monaco, Elekta) based on the daily images using machine delivery log file and considering patient repositioning if applicable, 2) overlaying the daily dose to the planning image based on deformable image registering (DIR) (ADMIRE, Elekta), 3) assessing voxel dose deformation accuracy based on deformation field using predetermined criteria, and 4) outputting accumulated dose and dose-accuracy volume histograms and parameters. Daily CTs acquired using a CT-on-rails during routine CT-guided RT for sample patients with head and neck and prostate cancers were used to test the process. Results: Daily and accumulated doses (dose-volume histograms, etc) along with their accuracies (dose-accuracy volume histogram) can be robustly generated using the proposed process. The test data for a head and neck cancer case shows that the gross tumor volume decreased by 20% towards the end of treatment course, and the parotid gland mean dose increased by 10%. Such information would trigger adaptive replanning for the subsequent fractions. The voxel-based accuracy in the accumulated dose showed that errors in accumulated dose near rigid structures were small. Conclusion: A procedure as well as necessary tools to automatically accumulate daily dose and assess dose accumulation accuracy is developed and is useful for adaptive replanning. Partially supported by Elekta, Inc.

60 APPLIED LIFE SCIENCES↗

Unconventional route to dual-shelled organolead halide perovskite nanocrystals with controlled dimensions, surface chemistry, and stabilities

The past few years have witnessed rapid advances in the synthesis of high-quality perovskite nanocrystals (PNCs). However, despite the impressive developments, the stability of PNCs remains a substantial challenge. The ability to reliably improve stability of PNCs while retaining their individual nanometer size represents a critical step that underpins future advances in optoelectronic applications. Here, we report an unconventional strategy for crafting dual-shelled PNCs (i.e., polymer-ligated perovskite/SiO 2 core/shell NCs) with exquisite control over dimensions, surface chemistry, and stabilities. In stark contrast to conventional methods, our strategy relies on capitalizing on judiciously designed star-like copolymers as nanoreactors to render the growth of core/shell NCs with controlled yet tunable perovskite core diameter, SiO 2 shell thickness, and surface chemistry. Consequently, the resulting polymer-tethered perovskite/SiO 2 core/shell NCs display concurrently a stellar set of substantially improved stabilities (i.e., colloidal stability, chemical composition stability, photostability, water stability), while having appealing solution processability, which are unattainable by conventional methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrically driven photon emission from individual atomic defects in monolayer WS 2

Quantum dot–like single-photon sources in transition metal dichalcogenides (TMDs) exhibit appealing quantum optical properties but lack a well-defined atomic structure and are subject to large spectral variability. Here, we demonstrate electrically stimulated photon emission from individual atomic defects in monolayer WS 2 and directly correlate the emission with the local atomic and electronic structure. Radiative transitions are locally excited by sequential inelastic electron tunneling from a metallic tip into selected discrete defect states in the WS 2 bandgap. Coupling to the optical far field is mediated by tip plasmons, which transduce the excess energy into a single photon. The applied tip-sample voltage determines the transition energy. Atomically resolved emission maps of individual point defects closely resemble electronic defect orbitals, the final states of the optical transitions. Inelastic charge carrier injection into localized defect states of two-dimensional materials provides a powerful platform for electrically driven, broadly tunable, atomic-scale single-photon sources.

74 ATOMIC AND MOLECULAR PHYSICS↗

Global minimization via classical tunneling assisted by collective force field formation

Simple elements interacting in networks can give rise to intricate emergent behaviors. Examples such as synchronization and phase transitions often apply in many contexts, as many different systems may reduce to the same effective model. Here, we demonstrate such a behavior in a model inspired by memristors. When weakly driven, the system is described by movement in an effective potential, but when strongly driven, instabilities cause escapes from local minima, which can be interpreted as an unstable tunneling mechanism. We dub this collective and nonperturbative effect a “Lyapunov force,” which steers the system toward the global minimum of the potential function, even if the full system has a constellation of equilibrium points growing exponentially with the system size. This mechanism is appealing for its physical relevance in nanoscale physics and for its possible applications in optimization, Monte Carlo schemes, and machine learning.

97 MATHEMATICS AND COMPUTING↗

Reticulated Nanoporous Polymers by Controlled Polymerization-Induced Microphase Separation

Materials with percolating mesopores are attractive for applications such as catalysis, nanotemplating, and separations. Polymeric frameworks are particularly appealing because the chemical composition and the surface chemistry are readily tunable. We report on the preparation of robust nanoporous polymers with percolating pores in the 4- to 8-nanometer range from a microphase-separated bicontinuous precursor. We combined polymerization-induced phase separation with in situ block polymer formation from a mixture of multifunctional monomers and a chemically etchable polymer containing a terminal chain transfer agent. This marriage results in microphase separation of the mixture into continuous domains of the etchable polymer and the emergent cross-linked polymer. Precise control over pore size distribution and mechanical integrity renders these materials particularly suited for various advanced applications.

36 MATERIALS SCIENCE↗

Metagenomic analysis reveals global-scale patterns of ocean nutrient limitation

Genomes reveal nutrient stress patterns Within the surface ocean, nitrogen, iron, and phosphorous can all be limiting nutrients for phytoplankton depending on location. Ustick et al. used the prevalence of Prochlorococcus genes involved in nutrient acquisition to develop maps of inferred nutrient stress across the global ocean (see the Perspective by Coleman). They found broad patterns of limitation consistent with an Earth system model and nutrient addition experiments. Leveraging metagenomic data in this manner is an appealing approach that will help to expand our understanding of the biogeochemistry in the vast open ocean. Science , this issue p. 287 ; see also p. 239

Science & Technology - Other Topics↗

Engineered Root Bacteria Release Plant-Available Phosphate from Phytate

Phosphate fertilizers are essential for high-yield agriculture yet are costly and environmentally damaging. Microbes that release soluble phosphate from naturally occurring sources in the soil are appealing, as they may reduce the need for such fertilizers. In this study, we used synthetic biology approaches to create a collection of engineered root-associated microbes with the ability to release phosphate from phytate. We demonstrate that these strains improve plant growth under phosphorus-limited conditions. This represents a first step in the development of phosphate-mining bacteria for future use in crop systems.

59 BASIC BIOLOGICAL SCIENCES↗