Search NASA⌕ Search

SEARCH · Search NASA

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Impact of respiratory motion correction on SPECT myocardial perfusion imaging using a mechanically moving phantom assembly with variable cardiac defects

Background: The aim of this study was to determine the impact of respiratory motion correction on SPECT MPI and on defect detection using a phantom assembly. Methods: SPECT/CT data were acquired using an anthropomorphic phantom with inflatable lungs and with an ECG beating and moving cardiac compartment. The heart motion followed the respiratory pattern in the cranio-caudal direction to simulate normal or deep breathing. Small or large transmural defects were inserted into the myocardial wall of the left ventricle. SPECT/CT images were acquired for each of the four respiratory phases, from exhale to inhale. A respiratory motion correction was applied using an image-based method with transformation parameters derived from the SPECT data by a non-rigid registration algorithm. A report on defect detection from two physicians and a quantitative analysis on MPI data were performed before and after applying motion correction. Results: Respiratory motion correction eliminated artifacts present in the images, resulting in a uniform uptake and reduction of motion blurring, especially in the inferior and anterior regions of the LV myocardial walls. The physicians’ report after motion correction showed that images were corrected for motion. Conclusions: A combination of motion correction with attenuation correction reduces artifacts in SPECT MPI. AC-SPECT images with and without motion correction should be simultaneously inspected to report on small defects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single Analyzer Precursor Ion Scans in a Linear Quadrupole Ion Trap Using Orthogonal Double Resonance Excitation

Reported herein is a simple method of performing single analyzer precursor ion scans in a linear quadrupole ion trap using orthogonal double resonance excitation. A first supplementary AC signal applied to the y electrodes is scanned through ion secular frequencies in order to mass-selectively excite precursor ions while, simultaneously, a second fixed-frequency AC signal is applied orthogonally on the x electrodes in order to eject product ions of selected mass-to-charge ratios towards the detector. The two AC signals are applied orthogonally so as to preclude the possibility of (1) inadvertently ejecting precursor ions into the detector, which results in artifact peaks, and (2) prevent beat frequencies on the x electrodes from ejecting ions off-resonance. Precursor ion scans are implemented while using the inverse Mathieu q scan for easier mass calibration. The orthogonal double resonance experiment results in single ion trap precursor scans with far less intense artifact peaks than when both AC signals are applied to the same electrodes, paving the way for implementation of neutral loss scanning in single ion trap mass spectrometers. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pitfalls in the Diagnosis of Acute Pulmonary Embolism on Computed Tomography: Common Pathologic and Imaging Mimics

Purpose of Review: Acute pulmonary embolism (PE) is the third most-common acute cardiovascular disease in the United States. Nearly 900,000 new diagnoses are made each year, with 250,000 associated hospitalizations and up to 100,000 deaths (Palacio et al. in Semin Roentgenol 50(3):217–225, 2015; Metter et al. in Am J Roentgenol 208(3):489–494, 2017; Jaff et al. in Circulation 123(16):1788–830, 2011). Timely and accurate diagnosis of acute PE is crucial for the prevention of most deaths associated with PE, even more so than optimal medical therapy (Palacio et al. in Semin Roentgenol 50(3):217–225, 2015; Jaff et al. in Circulation 123(16):1788–830, 2011; Raja et al. in Ann Intern Med 163(9):701, 2015). Recent Findings: Computed tomography (CT) has emerged as the primary imaging modality used in the diagnosis of acute PE. Thus, radiologists play a key role in the correct diagnosis of acute PE, and must differentiate this diagnosis from other conditions that mimic the imaging findings of acute PE, as well as from artifacts associated with imaging techniques (Palacio et al. in Semin Roentgenol 50(3):217–225, 2015; Jaff et al. in Circulation 123(16):1788–830, 2011; Raja et al. in Ann Intern Med 163(9):701, 2015). Understanding how these diagnoses present on CT is necessary for improved patient care. Summary: This article will discuss the diagnosis of acute PE with CT, the diagnosis of diseases that may be mistaken for acute PE, and how to identify imaging artifacts that may be mistaken for an acute PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D MRI in Musculoskeletal Imaging: Current and Future Applications

Purpose of Review: This article addresses current clinical applications, recent literature, and potential future applications of 3-dimensional magnetic resonance imaging (3D MRI) for musculoskeletal (MSK) applications. Recent Findings: The main advantage of 3D MRI over standard 2-dimensional MRI is its ability to reduce partial volume averaging artifacts and create multiplanar reconstruction (MPRs) in any plane with any slice thickness from a single high-resolution isotropic acquisition. 3D MRI acquisitions are particularly useful for the evaluation of articular cartilage, which is prone to volume averaging artifacts, and for the assessment of longitudinally coursing structures such as peripheral nerves and tendons, which are better visualized with non-orthogonal MPRs. 3D MRI is also useful for surface and volumetric analysis of bone and cartilage for preoperative and longitudinal assessments. Current research is focused on decreasing acquisition times and automating segmentation through machine learning, thus overcoming some of the current limitations of 3D MRI and providing new applications for this technique. Summary: 3D MRI is widely used in MSK imaging today, and its use is likely to continue to increase in the future, with recent advancements focused on accelerated acquisition techniques and quantitative imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimodal imaging and machine learning to enhance microscope images of shale

A machine learning based image processing workflow is presented to enhance shale source rock microscopic images obtained using diverse imaging platforms. Images were acquired from a 30 μm diameter cylindrical Vaca Muerta shale sample using both nondestructive Transmission X-Ray Microscopy (TXM, alternately referred to as nano computed tomography) and destructive Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM). Output cross-sectional images from each modality were aligned using a combination of manual and automated registration techniques to create a registered image dataset. We then apply this dataset for two image processing tasks: prediction of image cross sections with SEM-like resolution from nondestructive TXM data and repair of charged region artifacts (localized accumulation of electrons) within SEM images. The image processing algorithms for both tasks use deep learning models, specifically image-to-image Convolutional Neural Networks (CNNs) and conditional Generative Adversarial Networks (cGANs). In the image enhancement tasks, we are able to achieve significant qualitative and quantitative improvement in TXM images. Here, the best model reaches an average Peak Signal to Noise Ratio (PSNR) of 15.8 dB. Conditioning on TXM data is also shown to reduce artifacts from SEM charging, achieving an average PSNR of 25.8 dB. Furthermore, our results suggest that properly trained and validated networks are capable of significant enhancement of images obtained using nondestructive techniques, thereby improving interpretation of two- and three-dimensional images while preserving samples for future use.

58 GEOSCIENCES↗

Directly imaging steeply-dipping fault zones in geothermal fields with multicomponent seismic data

For characterizing geothermal systems, it is important to have clear images of steeply-dipping fault zones because they may confine the boundaries of geothermal reservoirs and influence hydrothermal flow. Elastic reverse-time migration (ERTM) is the most promising tool for subsurface imaging with multicomponent seismic data. However, conventional ERTM usually generates significant artifacts caused by the cross correlation of undesired wavefields and the polarity reversal of shear waves. In addition, it is difficult for conventional ERTM to directly image steeply-dipping fault zones. We develop a new ERTM imaging method in this paper to reduce these artifacts and directly image steeply-dipping fault zones. In our new ERTM method, forward-propagated source wavefields and backward-propagated receiver wavefields are decomposed into compressional (P) and shear (S) components. Furthermore, each component of these wavefields is separated into left- and right-going, or downgoing and upgoing waves. The cross correlation imaging condition is applied to the separated wavefields along opposite propagation directions. For converted waves (P-to-S or S-to-P), the polarity correction is applied to the separated wavefields based on the analysis of Poynting vectors. Numerical imaging examples of synthetic seismic data demonstrate that our new ERTM method produces high-resolution images of steeply-dipping fault zones.

58 GEOSCIENCES↗

Time-lapse 3-D electrical resistance tomography inversion for crosswell monitoring of dissolved and supercritical CO 2 flow at two field sites: Escatawpa and Cranfield, Mississippi, USA

In this study, we advance the understanding of three-dimensional (3-D) electrical resistivity tomography (ERT) for monitoring long-term CO 2 storage by analyzing two previously published field time-lapse data sets. We address two important aspects of ERT inversion-the issue of resolution decay, a general impediment to the ERT method, and the issue of potentially misleading imaging artifacts due to 2-D model assumptions. The first study analyzes data from a shallow dissolved-CO 2 injection experiment near Escatawpa (Mississippi), where ERT data were collected in a 3-D crosswell configuration. Here, we apply a focusing approach designed for crosswell configurations to counteract resolution loss in the inter-wellbore area, with synthetic studies demonstrating its effectiveness. The 3-D field data analysis reveals an initially southwards-trending flow path development and a dispersing plume development in the downgradient inter-well region. The second data set was collected during a deep (over 3 km) injection of supercritical CO 2 near Cranfield (Mississippi). Comparative 2-D and 3-D inversions reveal the projection of off-planar anomalies onto the cross-section, a typical artifact introduced by 2-D model assumptions. Conforming 3-D images from two different algorithms support earlier hydrological investigations, indicating a conduit system where flow velocity variations lead to a circumvention of a close observation well and an onset of increased CO 2 saturation downgradient from this well. We relate lateral permeability variations indicated by an independently obtained hydrological analysis to this consistently observed pattern in the CO 2 spatial plume evolution.

3-D inversion↗

High Retention and Safety of Percutaneously Implanted Endovascular Embolization Coils as Fiducial Markers for Image-Guided Stereotactic Ablative Radiotherapy of Pulmonary Tumors

Purpose: To compare the retention rates of two types of implanted fiducial markers for stereotactic ablative radiotherapy (SABR) of pulmonary tumors, smooth cylindrical gold 'seed' markers ('seeds') and platinum endovascular embolization coils ('coils'), and to compare the complication rates associated with the respective implantation procedures. Methods and Materials: We retrospectively analyzed the retention of percutaneously implanted markers in 54 consecutive patients between January 2004 and June 2009. A total of 270 markers (129 seeds, 141 coils) were implanted in or around 60 pulmonary tumors over 59 procedures. Markers were implanted using a percutaneous approach under computed tomography (CT) guidance. Postimplantation and follow-up imaging studies were analyzed to score marker retention relative to the number of markers implanted. Markers remaining near the tumor were scored as retained. Markers in a distant location (e.g., pleural space) were scored as lost. CT imaging artifacts near markers were quantified on radiation therapy planning scans. Results: Immediately after implantation, 140 of 141 coils (99.3%) were retained, compared to 110 of 129 seeds (85.3%); the difference was highly significant (p < 0.0001). Of the total number of lost markers, 45% were reported lost during implantation, but 55% were lost immediately afterwards. No additional markers were lost on longer-term follow-up. Implanted lesions were peripherally located for both seeds (mean distance, 0.33 cm from pleural surface) and coils (0.34 cm) (p = 0.96). Incidences of all pneumothorax (including asymptomatic) and pneumothorax requiring chest tube placement were lower in implantation of coils (23% and 3%, respectively) vs. seeds (54% and 29%, respectively; p = 0.02 and 0.01). The degree of CT artifact was similar between marker types. Conclusions: Retention of CT-guided percutaneously implanted coils is significantly better than that of seed markers. Furthermore, implanting coils is at least as safe as implanting seeds. Using coils should permit implantation of fewer markers and require fewer repeat implantation procedures owing to lost markers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Clinical Evaluation of a Three-Dimensional Cone-Beam Computed Tomography Estimation Method Using a Deformation Field Map

Purpose: To develop a three-dimensional (3D) cone-beam computed tomography (CBCT) estimation method using a deformation field map, and to evaluate and optimize the efficiency and accuracy of the method for use in the clinical setting. Methods and Materials: We propose a method to estimate patient CBCT images using prior information and a deformation model. Patients' previous CBCT data are used as the prior information, and the new CBCT volume to be estimated is considered as a deformation of the prior image volume. The deformation field map is solved by minimizing deformation energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. This method was implemented in 3D form using hardware acceleration and multi-resolution scheme, and it was evaluated for different scan angles, projection numbers, and scan directions using liver, lung, and prostate cancer patient data. The accuracy of the estimation was evaluated by comparing the organ volume difference and the similarity between estimated CBCT and the CBCT reconstructed from fully sampled projections. Results: Results showed that scan direction and number of projections do not have significant effects on the CBCT estimation accuracy. The total scan angle is the dominant factor affecting the accuracy of the CBCT estimation algorithm. Larger scan angles yield better estimation accuracy than smaller scan angles. Lung cancer patient data showed that the estimation error of the 3D lung tumor volume was reduced from 13.3% to 4.3% when the scan angle was increased from 60 Degree-Sign to 360 Degree-Sign using 57 projections. Conclusions: The proposed estimation method is applicable for 3D DTS, 3D CBCT, four-dimensional CBCT, and four-dimensional DTS image estimation. This method has the potential for significantly reducing the imaging dose and improving the image quality by removing the organ distortion artifacts and streak artifacts shown in images reconstructed by the conventional Feldkamp-Davis-Kress (FDK) algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the reliability of fast Fourier transform-based crystal plasticity simulations of a polycrystalline material near a crack tip

Crystal plasticity simulations enable a physically-based description of the micromechanical fields associated with microstructural attributes in polycrystalline materials. Fast Fourier transforms implementation of crystal plasticity (CP-FFT) in periodic unit cells offers increased computational efficiency compared to traditional finite element methods (CP-FEM). Albeit, questions may arise concerning the accuracy of the CP-FFT approach given its underlying spectral framework, specifically in regards to: potential artifacts due to violating the traction-free conditions at internal free surface within the unit cell, Gibbs phenomenon near regions with sharp changes in local mechanical properties, and representation of free surfaces under the constraints imposed by the requirement of periodicity of the unit cell. This paper presents a custom massively parallelized implementation of CP-FFT. A direct comparison of simulation results for polycrystalline deformation near a crack in a Ti55531 alloy is presented between CP-FEM and CP-FFT. The micromechanical fields and slip system level values are quantified and are similar between the two methods. Up to 10% difference in the stress fields is reported at the crack tip and this value dissipates moving away from the crack tip after 5 voxels (7 µm). In conclusion, the results point towards the reliable use of CP-FFT simulations to model polycrystalline deformation with caveats based on the treatment of the discussed artifacts.

36 MATERIALS SCIENCE↗

SREMI: Super-resolution electromagnetic imaging with single-channel ground-penetrating radar

High-resolution near-surface imaging has important applications in civil engineering, infrastructure inspection, military threat detection, geological characterization, and lunar and planetary exploration. Zero-offset, singlechannel ground penetrating radar (GPR) imaging is an established technique for near-surface target imaging and sensing but often suffers from low spatial resolution and imaging artifacts, especially of deep structures. In response, we formulate the GPR imaging as a dual-sparsity optimization problem, and develop a super-resolution electromagnetic imaging method based on a fast iterative shrinkage-thresholding algorithm. We develop our GPR imaging method in the framework of electromagnetic exploding-reflectors simulation theory, therefore the imaging method is computationally efficient. In this work, we demonstrate through synthetic and field data examples that our method can produce sharper, more reliable images with fewer artifacts compared with single-pass reverse-time migration GPR method, thus leading to improved near-surface interpretation and object identification.

58 GEOSCIENCES↗

Magnetic anisotropy in permalloy antidot square lattice

Here, magnetic anisotropy of Permalloy (Py) antidot square lattice was investigated by torquemetry method using Rotation Magneto-Optic Kerr Effect (ROTMOKE). We find that there exists a field-dependent 4-fold magnetic anisotropy with the easy magnetization axis along the axis of the antidot square lattice. In addition, there also exists an artifact of a uniaxial magnetic anisotropy in ROTMOKE result. We show that both results are due to the period wiggling of the magnetization in space which was confirmed by magnetic imaging using magnetic transmission soft x-ray microscopy (MTXM). Micromagnetic simulation from MuMax3 supports the wiggling structure of the magnetization, as well as reproduces ROTMOKE result. A simplified model was developed based on the periodic wiggling of the magnetization and successfully explored the physical origin of the field-dependent 4-fold anisotropy and the artifact of the uniaxial anisotropy.

36 MATERIALS SCIENCE↗

Systematic and statistical uncertainties of the hilbert-transform based high-precision FID frequency extraction method

Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytically. A method of mitigating the artifacts in the extracted phase function of an FID is discussed. Correlations between noises of the phase function samples are studied for different noise spectra. We discovered that the error covariance matrix for the extracted phase function is nearly singular and improper for constructing the $\chi^2$ used in the fitting routine. A down-sampling method for fixing the singular covariance matrix has been developed, so that the minimum $\chi^2$-fit yields properly the statistical uncertainty of the extracted frequency. Other practical methods of obtaining the statistical uncertainty are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Simulation of Borosilicate Glass Dissolution using Molecular Dynamics-Generated Glass Structures

Atomic-scale insights into the dissolution mechanisms of borosilicate glasses are critical to the development of the waste form corrosion models that inform performance assessments of nuclear waste disposal facilities. Monte Carlo (MC) simulations have been instrumental in advancing the state of knowledge of borosilicate glass dissolution; however, all such simulations to date have relied on lattices to represent the amorphous glass structure, thereby potentially introducing artifacts. Therefore, a new approach, referred to as the amorphous MC approach, has been developed whereby glass structures generated from molecular dynamics simulations are used as starting points for MC simulations of glass dissolution. MC simulations of sodium borosilicate glasses that covered a wide compositional range were performed and revealed correlations between dissolution rate and structural features of the glasses. Notably, the lattice MC approach predicted the fraction of tetrahedral boron to have a lesser influence on the dissolution rate than computed with the amorphous MC approach. The lattice MC simulations also overestimated the dissolution rate for a given glass composition. These findings highlight the importance of using truly amorphous structures in MC simulations of glass corrosion.

Kerisit, Sebastien N.↗

Modeling the impact of radiation-enhanced diffusion on implanted ion profiles

We report that ion irradiations are a valuable research tool for exploring radiation effects in materials. However, it is well recognized that the implanted ions can artificially modify the radiation damage evolution, e.g., enhancing amorphization processes at low irradiation temperatures and suppressing void swelling at elevated temperatures. Therefore, the implanted ion region should be avoided for most studies of ion irradiated materials. Due to increased interest in high damage, high temperature ion irradiations studying radiation effects in materials for proposed high dose Generation IV fission and fusion energy applications, it is crucial to quantify the extent of diffusional broadening of the implanted ion profile for a variety of temperatures, irradiation fluxes, and sink strengths. The present study summarizes computational analyses of thermal and depth-dependent radiation enhanced difusion (RED) on diffusion broadening of the implanted ion profiles in Fe and Ni for a variety of irradiation conditions. For a low assumed RED coefficient (10 -20 -10 -19 m 2 /s and 10 -4 and 10 -3 peak dpa/s, respectively) or high flux, broadening of the as-implanted ion profile is very small and a suitable artifact-free midrange region for analysis exists for ion energies above 5-6 MeV at 100 peak dpa. At high RED coefficients (10 -19 -10 -18 m 2 /s and 10 -4 and 10 -3 peak dpa/s, respectively) broadening is much more significant, and no valid region for investigation exists below 6-8 MeV ion energies at any damage level >50 dpa. While increasing flux decreases irradiation time, it also increases the RED coefficient; these effects mostly offset except under recombination-dominant conditions. For typical high dose irradiation studies of void swelling that exceed ~100 displacement per atom (dpa), ion energies > 6-8 MeV must be employed in order to achieve suitable artifact-free midrange irradiation analysis regions, depending on the material system. Lastly, analysis of amorphization/precipitation require even higher energies (>10 MeV).

07 ISOTOPE AND RADIATION SOURCES↗

Mesoscale Modeling of the Effects of Accelerated Burnup on UO2 Microstructural Evolution

Accelerating the nuclear fuel qualification process will rely on some combination of advanced modeling and simulation techniques with accelerated irradiation testing and separate effects experiments to enable the development of new fuel concepts in a shorter time frame. One of the key challenges to successfully leveraging accelerated irradiation tests will be understanding the artifacts that may be introduced with accelerated accumulation of dose and/or burnup. This work presents phase field (MARMOT) simulations of the evolution of representative 2D UO2 microstructures up to 40 MWd/kgU. Simulations were performed under both commercial light water reactor fuel conditions as well as those that would be expected for highly accelerated (~10x) burnup conditions similar to those used in the MiniFuel irradiations in Oak Ridge National Laboratory’s High Flux Isotope Reactor. The phase field model was coupled with a discrete nucleation algorithm to model re- structuring at high burnup. The effect of the different fission rates in both microstructures was investigated at two temperatures: 650?C and 800?C. The lower temperature simulations both showed an onset of restructuring at nearly 60 MWd/kgU. More extensive restructuring was obtained in the MiniFuel microstructure compared with that of the PWR fuel. At 800?C, no restructuring was obtained as a result of the thermally activated diffusion of Xe atoms and U vacancies to fission gas bubbles, which reduces the nucleation driving force. These results highlight the importance of using modeling and simulation tools to inform the environmental conditions during targeted accelerated irradiation tests to extract the most useful fuel performance data.

accelerated fuel qualification, Phase Field, Restr↗

Deposition of metallic gallium on re-crystallized ceramic material during focused ion beam milling

We report a new kind of artifact observed in the preparation of a TEM sample of zirconia by FIB, which consists in the deposition of metallic gallium nano-dots on the TEM sample surface. High resolution TEM images showed a microstructure of fine equiaxed grains of ∼ 5 nm, with some of them possessing two particular characteristics: high contrast and well-defined fast Fourier transform. These grains could not be identified as any phase of zirconia but it was possible to identify them as gallium crystals in the zone axis [110]. Based on HRTEM simulations, the possible orientations between zirconia substrate and deposited gallium are discussed in terms of lattice mismatch and oxygen affinity. - Highlights: • We show a new type of artifact induced during preparation of TEM samples by FIB. • Deposition of Ga occurs due to its high affinity for oxygen. • Materials with small grain size (∼ 5 nm) could promote Ga deposition. • Small grain size permits the elastic accommodation of deposited Ga.

36 MATERIALS SCIENCE↗