Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Magnets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The Design of B1APF Dipole for the EIC

Brookhaven National Laboratory has been chosen to host the Electron-Ion Collider (EIC). Part of this is to install an additional electron ring to the existing RHIC tunnel. The electron hadron Interaction Region (IR) will host nine superconducting magnets on the forward side and six superconducting magnets on the rear side of the Interaction Point (IP). B1APF dipole is the last magnet of the near IR in the outgoing hadron direction. Further, the magnet has a physical aperture of 370 mm diameter and is 1.5 m long. This large aspect ratio makes this magnet particularly challenging. It is a collared magnet and uses a NbTi Rutherford cable with 15.1 mm X 1.9 mm. It is expected to operate at a maximum current of 13400 A at 2 K. The required integrated dipole field is 4.05 Tm. This paper discusses the current design status of the B1ApF dipole and presents the electromagnetic analysis and thermal quench propagation analysis.

43 PARTICLE ACCELERATORS↗

SU-G-JeP2-15: Proton Beam Behavior in the Presence of Realistic Magnet Fields

Purpose: To investigate the effects of magnetic fields on proton therapy beams for integration with MRI. Methods: 3D magnetic fields from an open-bore superconducting MRI model (previously developed by our group) and 3D magnetic fields from an in-house gradient coil design were applied to various mono energetic proton pencil beam (80MeV to 250MeV) simulations. In all simulations, the z-axis of the simulation geometry coincided with the direction of the B0 field and magnet isocentre. In each simulation, the initial beam trajectory was varied. The first set of simulations performed was based on analytic magnetic force equations (analytic simulations), which could be rapidly calculated yet were limited to propagating proton beams in vacuum. The second set is full Monte Carlo (MC) simulations, which used GEANT4 MC toolkit. Metrics such as the beam position and dose profiles were extracted. Comparisons between the cases with and without magnetic fields present were made. Results: The analytic simulations served as verification checks for the MC simulations when the same simulation geometries were used. The results of the analytic simulations agreed with the MC simulations performed in vacuum. The presence of the MRI’s static magnetic field causes proton pencil beams to follow a slight helical trajectory when there were some initial off-axis components. The 80MeV, 150MeV, and 250MeV proton beams rotated by 4.9o, 3.6o, and 2.8o, respectively, when they reached z=0cm. The deflections caused by gradient coils’ magnetic fields show spatially invariant patterns with a maximum range of 0.5mm at z=0cm. Conclusion: This investigation reveals that both the MRI’s B0 and gradient magnetic fields can cause small but observable deflections of proton beams at energies studied. The MRI’s static field caused a rotation of the beam while the gradient coils’ fields effects were spatially invariant. Dr. B Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

60 APPLIED LIFE SCIENCES↗

SUZAKU WIDE BAND ANALYSIS OF THE X-RAY VARIABILITY OF TeV BLAZAR Mrk 421 IN 2006

We present the results of X-ray observations of the well studied TeV blazar Mrk 421 with the Suzaku satellite in 2006 April 28. During the observation, Mrk 421 was undergoing a large flare and the X-ray flux was variable, decreasing by {approx}50%, from 7.8 x 10{sup -10} to 3.7 x 10{sup -10} erg s{sup -1} cm{sup -2} in about 6 hr, followed by an increase by {approx}35%. Thanks to the broad bandpass coupled with high sensitivity of Suzaku, we measured the evolution of the spectrum over the 0.4-60 keV band in data segments as short as {approx}1 ks. The data show deviations from a simple power-law model, but also a clear spectral variability. The time-resolved spectra are fitted by a synchrotron model, where the observed spectrum is due to a exponentially cutoff power-law distribution of electrons radiating in uniform magnetic field; this model is preferred over a broken power law. As another scenario, we separate the spectrum into 'steady' and 'variable' components by subtracting the spectrum in the lowest-flux period from those of other data segments. In this context, the difference ('variable') spectra are all well described by a broken power-law model with photon index {gamma} {approx} 1.6, breaking at energy {epsilon}{sub brk} {approx_equal} 3 keV to another photon index {gamma} {approx} 2.1 above the break energy, differing from each other only by normalization, while the spectrum of the 'steady' component is best described by the synchrotron model. We suggest that the rapidly variable component is due to relatively localized shock (Fermi I) acceleration, while the slowly variable ('steady') component is due to the superposition of shocks located at larger distance along the jet, or due to other acceleration process, such as the stochastic acceleration on magnetic turbulence (Fermi II) in the more extended region.

99 GENERAL AND MISCELLANEOUS↗

The optimization of a DC injector for the Energy Recovery Linac upgrade to APS

An energy recovery linac based light source is a potential revolutionary upgrade to the Advanced Photon Source (APS) at Argonne National Laboratory. The concept relies on several key research areas, one of which is the generation of ultra-low emittance, high-average-current electron beams. In this paper, we present our investigation of a dc-gun-based system for ultra-low emittance bunches in the 20 pC range. A parallel multi-objective numerical optimization is performed in multi-parameter space. Parameters varied include experimentally feasible drive-laser shapes, the DC gun voltage, the thermal energy of the emitted photo-electrons and other electric or magnetic field strengths, RF cavity phase etc. Our goal is to deliver a {approx}10 MeV, 20 pC bunch at the entrance of the linac with an emittance of 0.1 {micro}m or lower, rms bunch length of 2 {approx} 3 ps, and energy spread no larger than 140 keV. We present the machine parameters needed to generate such an injector beam, albeit without a merger.

43 PARTICLE ACCELERATORS↗

Quench performance and field quality of FNAL twin-aperture 11 T Nb 3 Sn dipole model for LHC upgrades

A 2 m long single-aperture dipole demonstrator and two 1 m long single-aperture models based on Nb 3 Sn superconductor have been built and tested at FNAL. The two 1 m long collared coils were then assembled in a twin-aperture Nb 3 Sn dipole demonstrator compatible with the LHC main dipole and tested in two thermal cycles. This paper summarizes the quench performance of the FNAL twin-aperture Nb 3 Sn 11 T dipole in the temperature range of 1.9-4.5 K. The results of magnetic measurements for one of the two apertures are also presented. Test results are compared to the performance of coils in a single-aperture configuration. Lastly, a summary of quench propagation studies in both apertures is given.

43 PARTICLE ACCELERATORS↗

Laser-based profile and energy monitor for H beams

A beam profile and energy monitor for H{sup -} beams based on laser photoneutralization was built at Brookhaven National Laboratory (BNL)* for use on the High Intensity Neutrino Source (HMS) at Fermilab. An H{sup -} ion has a first ionization potential of 0.75eV and can be neutralized by light from a Nd:YAG laser ({lambda}=1064nm). To measure beam profiles, a narrow laser beam is stepped across the ion beam, removing electrons from the portion of the H{sup -} beam intercepted by the laser. These electrons are channeled into a Faraday cup by a curved axial magnetic field. To measure the energy distribution of the electrons, the laser position is fixed and the voltage on a screen in front of the Faraday cup is raised in small steps. We present a model which reproduces the measured energy spectrum from calculated beam energy and space-charge fields. Measurements are reported from experiments in the BNL linac MEBT at 750keV.

43 PARTICLE ACCELERATORS↗

Microbunching and RF Compression

Velocity bunching (or RF compression) represents a promising technique complementary to magnetic compression to achieve the high peak current required in the linac drivers for FELs. Here we report on recent progress aimed at characterizing the RF compression from the point of view of the microbunching instability. We emphasize the development of a linear theory for the gain function of the instability and its validation against macroparticle simulations that represents a useful tool in the evaluation of the compression schemes for FEL sources.

43 PARTICLE ACCELERATORS↗

Status of the SAGA Light Source

The SAGA Light Source (SAGA-LS) is a synchrotron radiation facility consisting of a 255 MeV injector linac and a 1.4 GeV storage ring that is 75.6 m in circumference. The SAGA-LS has been stably providing synchrotron radiation to users since it first started user operation in February 2006. Along with the user operation, various machine improvements have been made over the past years, including upgrading the injector linac control system, replacing a septum magnet and constructing a beam diagnostic system. In addition to these improvements, insertion devices have been developed and installed. An APPLE-II type variable polarization undulator was installed in 2008. To address the demand from users for high-flux hard x-rays, a superconducting 4 T class wiggler is being developed. An experimental setup for generating MeV photons by laser Compton scattering is being constructed for beam monitoring and future user experiments.

43 PARTICLE ACCELERATORS↗

Monte Carlo characterization of skin doses in 6 MV transverse field MRI-linac systems: Effect of field size, surface orientation, magnetic field strength, and exit bolus

Purpose: The main focus of this work is to continue investigations into the Monte Carlo predicted skin doses seen in MRI-guided radiotherapy. In particular, the authors aim to characterize the 70 {mu}m skin doses over a larger range of magnetic field strength and x-ray field size than in the current literature. The effect of surface orientation on both the entry and exit sides is also studied. Finally, the use of exit bolus is also investigated for minimizing the negative effects of the electron return effect (ERE) on the exit skin dose. Methods: High resolution GEANT4 Monte Carlo simulations of a water phantom exposed to a 6 MV x-ray beam (Varian 2100C) have been performed. Transverse magnetic fields of strengths between 0 and 3 T have been applied to a 30x30x20 cm{sup 3} phantom. This phantom is also altered to have variable entry and exit surfaces with respect to the beam central axis and they range from -75 deg. to +75 deg. The exit bolus simulated is a 1 cm thick (water equivalent) slab located on the beam exit side. Results: On the entry side, significant skin doses at the beam central axis are reported for large positive surface angles and strong magnetic fields. However, over the entry surface angle range of -30 deg. to -60 deg., the entry skin dose is comparable to or less than the zero magnetic field skin dose, regardless of magnetic field strength and field size. On the exit side, moderate to high central axis skin dose increases are expected except at large positive surface angles. For exit bolus of 1 cm thickness, the central axis exit skin dose becomes an almost consistent value regardless of magnetic field strength or exit surface angle. This is due to the almost complete absorption of the ERE electrons by the bolus. Conclusions: There is an ideal entry angle range of -30 deg. to -60 deg. where entry skin dose is comparable to or less than the zero magnetic field skin dose. Other than this, the entry skin dose increases are significant, especially at higher magnetic fields. On the exit side there is mostly moderate to high skin dose increases for 0.2-3 T with the only exception being large positive angles. Exit bolus of 1 cm thickness will have a significant impact on lowering such exit skin dose increases that occur as a result of the ERE.

60 APPLIED LIFE SCIENCES↗

Challenges and Opportunities for the Next Generation of Photon Regeneration Experiments

Photon regeneration experiments searching for signatures of oscillations of photons into hypothetical very weakly interacting ultra-light particles, such as axions, axion-like and hidden-sector particles, have improved their sensitivity considerably in recent years. Important progress in laser and detector technology as well as recycling of available magnets from accelerators may allow a big further step in sensitivity such that, for the first time, laser light shining through a wall experiments will explore territory in parameter space that has not been excluded yet by astrophysics and cosmology. We review these challenges and opportunities for the next generation experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-239: Influence of RF Coil Materials On Surface and Buildup Dose From a 6MV Photon Beam

Purpose: In order to perform real time tumour tracking using an integrated Linac-MR, images have to be acquired during irradiation. MRI uses RF coils in close proximity to the imaged volume. Given current RF coil designs this means that the high energy photons will be passing through the coil before reaching the patient. This study experimentally investigates the dose modifications that occur due to the presence of various RF coil materials in the treatment beam. Methods: Polycarbonate, copper or aluminum tape, and Teflon were used to emulate the base, conductor and cover respectively of a surface RF coil. These materials were placed at various distances from the surface of polystyrene or solid water phantoms which were irradiated in the presence of no magnetic field, a transverse 0.2T magnetic field, and a parallel 0.2T magnetic field. Percent depth doses were measured using ion chambers. Results: A significant increase in surface and buildup dose is observed. The surface dose is seen to decrease with an increasing separation between the emulated coil and the phantom surface, when no magnetic field is present. When a transverse magnetic field is applied the surface dose decreases faster with increasing separation, as some of the electrons created in the coil are curved away from the phantom’s surface. When a parallel field is present the surface dose stays approximately constant for small separations, only slightly decreasing for separations greater than 5cm, since the magnetic field focuses the electrons produced in the coil materials not allowing them to scatter. Conclusion: Irradiating a patient through an RF coil leads to an increase in the surface and buildup doses. Mitigating this increase is important for the successful clinical use of either a transverse or a parallel configuration Linac-MR unit. This project is partially supported by an operating grant from the Canadian Institute of Health Research (CIHR MOP 93752)

60 APPLIED LIFE SCIENCES↗

Linac Energy Management for LCLS

Linac Energy Management (LEM) is a control system program that scales magnet field set-point settings following a change in beam energy. LEM is necessary because changes in the number, phase, and amplitude of the active klystrons change the beam's rigidity, and therefore, to maintain constant optics, one has to change focusing gradients and bend fields accordingly. This paper describes the basic process, the control system application programs we developed for LEM, and some of the implementation lessons learned at the Linac Coherent Light Source (LCLS).

43 PARTICLE ACCELERATORS↗

Design of an Emittance Compensation Superconducting Magnet Package for LCLS-II-HE's SRF Photo-Injector

An SRF photo-injector (low frequency, quarter-wave resonator plus emittance compensation magnet) is planned for LCLS-II-HE as it can provide a higher cathode gradient and better electron beam quality than other types of CW electron guns. The magnet package is located immediately downstream of the SRF cavity, and incorporates a solenoid doublet, bucking coils for reduction of the fringe field, normal/skew quadrupoles and horizontal/vertical dipoles. All the magnets are wound of NbTi wire and operate in liquid helium environment. The solenoid package is located inside the SRF gun cryomodule. Design considerations include space limitations, optimal emittance compensation, the magnetic field limits in the superconducting wire and quench protection. The solenoid coils must provide a peak excitation > 25 kgauss 2 ·cm, a fringe field < 20 gauss at the wall of the SRF cavity, an integrated dipole field < 90 gauss·cm and an integrated quadrupole field < 10 gauss. As a result, a genetic algorithm was used to optimize the solenoid design. Correction dipoles and quadrupoles were designed using coil dominated Walstrom style coils.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self-Induced Harmonic Generation in a Storage-Ring Free-Electron Laser

Coherent radiation from a relativistic electron beam is a valuable way to overcome the present limitations of conventional lasers and synchrotron radiation light sources. The typical scheme has electrons, directly from a linac, in a single-pass interaction with a laser pulse in the presence of a static undulator magnetic field. We demonstrate that a storage-ring free-electron laser can also achieve harmonic generation (down to 36.5 nm), presenting both experimental and theoretical results, and offer a reliable interpretation of the peculiar underlying physical processes involved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system

The authors report the first magnetic resonance (MR) images produced by their prototype MR system integrated with a radiation therapy source. The prototype consists of a 6 MV linac mounted onto the open end of a biplanar 0.2 T permanent MR system which has 27.9 cm pole-to-pole opening with flat gradients (40 mT/m) running under a TMX NRC console. The distance from the magnet isocenter to the linac target is 80 cm. The authors' design has resolved the mutual interferences between the two devices such that the MR magnetic field does not interfere with the trajectory of the electron in the linac waveguide, and the radiofrequency (RF) signals from each system do not interfere with the operation of the other system. Magnetic and RF shielding calculations were performed and confirmed with appropriate measurements. The prototype is currently on a fixed gantry; however, in the very near future, the linac and MR magnet will rotate in unison such that the linac is always aimed through the opening in the biplanar magnet. MR imaging was found to be fully operational during linac irradiation and proven by imaging a phantom with conventional gradient echo sequences. Except for small changes in SNR, MR images produced during irradiation were visually and quantitatively very similar to those taken with the linac turned off. This prototype system provides proof of concept that the design has decreased the mutual interferences sufficiently to allow the development of real-time MR-guided radiotherapy. Low field-strength systems (0.2-0.5 T) have been used clinically as diagnostic tools. The task of the linac-MR system is, however, to provide MR guidance to the radiotherapy beam. Therefore, the 0.2 T field strength would provide adequate image quality for this purpose and, with the addition of fast imaging techniques, has the potential to provide 4D soft-tissue visualization not presently available in image-guided radiotherapy systems. The authors' initial design incorporates a permanent magnet; however, other types of magnets and field strengths could also be incorporated. Usable MR images were obtained during linac irradiation from the linac-MR prototype. The authors' prototype design can be used as the functional starting point in developing real-time MR guidance offering soft-tissue contrast that can be coupled with tumor tracking for real-time adaptive radiotherapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hall Probe Calibration System Design for the Mu2e Solenoid Field Mapping System

The goal of the Mu2e experiment at Fermilab is to search for charged-lepton flavor violation by looking for neutrino-less muon to electron conversion in the field of the nucleus. The Mu2e experimental apparatus utilizes a complex magnetic field in the muon generation and momentum and charge selection process. Precise knowledge of the magnetic field is crucial. It is planned to map the solenoid field with calibrated 3D Hall probes up to 10 -5 accuracy. Here, this article describes a new design of a Hall probe calibration system that will be used to calibrate 3D Hall probes to better than 10 -5 accuracy for the Mu2e Solenoid Field Mapping System.

43 PARTICLE ACCELERATORS↗

SU-F-J-147: Magnetic Field Dose Response Considerations for a Linac Monitor Chamber

Purpose: The impact of magnetic fields on the readings of a linac monitor chamber have not yet been investigated. Herein we examine the total dose response as well as any deviations in the beam parameters of flatness and symmetry when a Varian monitor chamber is irradiated within an applied magnetic field. This work has direct application to the development of Linac-MR systems worldwide. Methods: A Varian monitor chamber was modeled in the Monte Carlo code PENELOPE and irradiated in the presence of a magnetic field with a phase space generated from a model of a Linac-MR prototype system. The magnetic field strength was stepped from 0 to 3.0T in both parallel and perpendicular directions with respect to the normal surface of the phase space. Dose to each of the four regions in the monitor chamber were scored separately for every magnetic field adaptation to evaluate the effect of the magnetic field on flatness and symmetry. Results: When the magnetic field is perpendicular to the phase space normal we see a change in dose response with a maximal deviation (10–25% depending on the chamber region) near 0.75T. In the direction of electron deflection we expectedly see opposite responses in chamber regions leading to a measured asymmetry. With a magnetic field parallel to the phase space normal we see no measured asymmetries, however there is a monotonic rise in dose response leveling off at about +12% near 2.5T. Conclusion: Attention must be given to correct for the strength and direction of the magnetic field at the location of the linac monitor chamber in hybrid Linac-MR devices. Elsewise the dose sampled by these chambers may not represent the actual dose expected at isocentre; additionally there may be a need to correct for the symmetry of the beam recorded by the monitor chamber. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

Engineering Design of D1/D3 Dipole Magnets for the Electron-Ion Collider (EIC)

Here, the Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) is designed to deliver a peak luminosity of 10 34 cm −2 s −1 . An electron storage ring (ESR) will be installed in the existing Relativistic Heavy Ion Collider (RHIC) tunnel and will store polarized electron beams from 5 to 18 GeV. The ESR will have 750 dipole magnets with varying field requirements, including 576 super-bend triplets consisting of two magnets D1/D3 and D2. This paper presents on the engineering design of the D1/D3 dipole magnets within the arcs, with special focus on the coil design that allows the magnet to be configured for variable ampere-turns per energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗