At least 667 records · Page 37

Control of Stochastic Gene Expression by Host Factors at the HIV Promoter

The HIV promoter within the viral long terminal repeat (LTR) orchestrates many aspects of the viral life cycle, from the dynamics of viral gene expression and replication to the establishment of a latent state. In particular, after viral integration into the host genome, stochastic fluctuations in viral gene expression amplified by the Tat positive feedback loop can contribute to the formation of either a productive, transactivated state or an inactive state. In a significant fraction of cells harboring an integrated copy of the HIV-1 model provirus (LTR-GFP-IRES-Tat), this bimodal gene expression profile is dynamic, as cells spontaneously and continuously flip between active (Bright) and inactive (Off) expression modes. Furthermore, these switching dynamics may contribute to the establishment and maintenance of proviral latency, because after viral integration long delays in gene expression can occur before viral transactivation. The HIV-1 promoter contains cisacting Sp1 and NF-kB elements that regulate gene expression via the recruitment of both activating and repressing complexes. We hypothesized that interplay in the recruitment of such positive and negative factors could modulate the stability of the Bright and Off modes and thereby alter the sensitivity of viral gene expression to stochastic fluctuations in the Tat feedback loop. Using model lentivirus variants with mutations introduced in the Sp1 and NF-kB elements, we employed flow cytometry, mRNA quantification, pharmacological perturbations, and chromatin immunoprecipitation to reveal significant functional differences in contributions of each site to viral gene regulation. Specifically, the Sp1 sites apparently stabilize both the Bright and the Off states, such that their mutation promotes noisy gene expression and reduction in the regulation of histone acetylation and deacetylation. Furthermore, the NF-kB sites exhibit distinct properties, with kB site I serving a stronger activating role than kB site II. Moreover, Sp1 site III plays a particularly important role in the recruitment of both p300 and RelA to the promoter. Finally, analysis of 362 clonal cell populations infected with the viral variants revealed that mutations in any of the Sp1 sites yield a 6-fold higher frequency of clonal bifurcation compared to that of the wild-type promoter. Thus, each Sp1 and NF-kB site differentially contributes to the regulation of viral gene expression, and Sp1 sites functionally ‘‘dampen’’ transcriptional noise and thereby modulate the frequency and maintenance of this model of viral latency. These results may have biomedical implications for the treatment of HIV latency.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling the role of lateral surface flow in low‐relief polygonal tundra

Abstract Ice‐wedge polygon troughs play an important role in controlling the hydrology of low‐relief polygonal tundra regions. Lateral surface flow is confined to troughs only, but it is often neglected in model projections of permafrost thermal hydrology. Recent field and modeling studies have shown that, after rain events, increases in trough water levels are significantly more than the observed precipitation, highlighting the role of lateral surface flow in the polygonal tundra. Therefore, understanding how trough lateral surface flow can influence polygonal tundra thermal hydrology is important, especially under projected changes in temperatures and rainfall in the Arctic regions. Using an integrated cryohydrology model, this study presents plot‐scale end‐of‐century projections of ice‐wedge polygon water budget components and active layer thickness with and without trough lateral surface flow under the Representative Concentration Pathway 8.5 scenario. Trough lateral surface flow is incorporated through a newly developed empirical model, evaluated against field measurements. The numerical scenario that includes trough lateral surface flow simulates discharge (outflow from a polygon) and recharge (rain‐induced inflow to a polygon trough from upslope areas), while the scenario that does not include trough lateral surface flow ignores recharge. The results show considerable reduction (about 100–150%) in evapotranspiration and discharge in rainy years in the scenarios ignoring trough lateral surface flow, but less effect on soil water storage, in comparison with the scenario with trough lateral surface flow. In addition, the results demonstrate long‐term changes (~10–15 cm increase) in active layer thickness when trough lateral surface flow is modeled. This study highlights the importance of including lateral surface flow processes to better understand the long‐term thermal and hydrological changes in low‐relief polygonal tundra regions under a changing climate.

Jan, Ahmad↗

Induction of p53-mediated apoptosis in splenocytes and thymocytes of C57BL/6 mice exposed to perfluorooctane sulfonate (PFOS)

Perfluorooctane sulfonate (PFOS) is a persistent environmental contaminant found in human and wildlife tissues. It has been reported that PFOS can cause atrophy of the immune organs and apoptosis of immunocytes in rodents. However, the mechanism behind such cause is still unclear. To understand the model of cell death and its mechanism on lymphoid cells in vivo, we conducted a dose/response experiment in which 4 groups of male adult C57BL/6 mice (12 mice per group) were dosed daily by oral gavage with PFOS at 0, 0.0167, 0.0833, or 0.8333 mg/kg/day, yielding targeted Total Administered Dose (TAD) of 0, 1, 5, or 50 mg PFOS/kg, respectively, over 60 days. The results showed that spleen and thymus weight were significantly reduced in the highest PFOS-dose-group (TAD 50 mg PFOS/kg) compared to the control group, whereas liver weight was significantly increased. We analyzed the cell death via apoptosis with an annexin-V/propidium iodide assay by flow cytometry, and observed that both the percentage of apoptosis and the expression of the pro-apoptotic proteins p53 in splenocytes and thymocytes increased in a dose-related manner after PFOS treatment. We also observed that PFOS induced p53-dependent apoptosis through the cooperation between the Bcl-xl down regulation without changing the Bcl-2 and Bax expression. The down regulation of Bcl-xl was strongly indicating mitochondrial involvement in apoptosis. It is confirmed by the release of cytochrome c and activation of caspase-3. All of these findings establish an important role of p53 and mitochondrial function in PFOS induced toxic environment in the host. -- Highlights: ► PFOS immunotoxicity is caused by induction of apoptosis via the p53 activation. ► PFOS exposure can induce down regulation of Bcl-xl. ► Mitochondria are involved in PFOS-induced apoptosis. ► PFOS exposure can cause the release of cytochrome c and activation of caspase-3.

60 APPLIED LIFE SCIENCES↗

Conduction of Metal–Thin Organic Film–Metal Junctions at Low Bias

A model for the low bias electric conductance of junctions, consisting of a thin organic film (TOF) positioned between two metallic electrodes (M), has been created. In contrast with other theoretical studies, the proposed model relies on the energy band picture of M–TOF–M systems. Theoretical analysis of the band-like transport has shown that the electronic flow between metallic electrodes can exist in M–TOF–M junctions only if injected charge carriers are able to overcome the potential barrier with the thickness-dependent height. Such an obstacle to the motion of injected charges in the TOF conduction band arises due to the bending of this band caused by carriers localized in structural traps. Two regimes of the zero bias conductance of M–TOF–M junctions have been studied theoretically for situations, where charges overcome the thickness-dependent barrier undergoing either thermally activated or tunneling transitions. Analytical expressions derived for the zero bias conduction in these two regimes enable us to specify key physical parameters controlling charge transport across the film and provide results consistent with observations. On the basis of our findings, we infer that thermally activated and tunneling conductances can be distinguished by temperature and thickness dependencies. Theoretical results obtained for the electric conductance of M–TOF–M systems in the tunneling regime are compared with those obtained for assemblies in which TOF has been replaced by a single molecule. Furthermore, distinctions between transport properties of these two systems and their similarities resulting from the present model are reported on.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CaCO 3 Precipitation, Transport and Sensing in Porous Media with In Situ Generation of Reactants

Ureolytically driven calcite precipitation is a promising approach for inducing subsurface mineral precipitation, but engineered application requires the ability to control and predict precipitate distribution. To study the coupling between reactant transport and precipitate distribution, columns with defined zones of immobilized urease were used to examine the distribution of calcium carbonate precipitation along the flow path, at two different initial flow rates. As expected, with slower flow precipitate was concentrated toward the upstream end of the enzyme zone and with higher flow the solid was more uniformly distributed over the enzyme zone. Under constant hydraulic head conditions the flow rate decreased as precipitates decreased porosity and permeability. The hydrolysis/precipitation zone was expected to become compressed in the upstream direction. However, apparent reductions in the urea hydrolysis rate and changes in the distribution of enzyme activity, possibly due to CaCO 3 precipitate hindering urea transport to the enzyme, or enzyme mobilization, mitigated reaction zone compression. Co-injected strontium was expected to be sequestered by coprecipitation with CaCO 3 , but the results suggested that coprecipitation was not an effective sequestration mechanism in this system. In addition, spectral induced polarization (SIP) was used to monitor the spatial and temporal evolution of the reaction zone.

54 ENVIRONMENTAL SCIENCES↗

Colloid Science of Metal Nanoparticle Catalysts in 2D and 3D Structures. Challenges of Nucleation, Growth, Composition, Particle Shape, Size Control and their Influence on Activity and Selectivity

Recent breakthroughs in synthesis in nanosciences have achieved control of size and shapes of nanoparticles that are relevant for catalyst design. In this article, we review the advance of synthesis of nanoparticles, fabrication of two and three dimensional model catalyst system, characterization, and studies of activity and selectivity. The ability to synthesize monodispersed platinum and rhodium nanoparticles in the 1-10 nm range permitted us to study the influence of composition, structure, and dynamic properties of monodispersed metal nanoparticle on chemical reactivity and selectivity. We review the importance of size and shape of nanoparticles to determine the reaction selectivity in multi-path reactions. The influence of metal-support interaction has been studied by probing the hot electron flows through the metal-oxide interface in catalytic nanodiodes. Novel designs of nanoparticle catalytic systems are discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Transient evolution of permeability and friction in a slowly slipping fault activated by fluid pressurization

The mechanisms of permeability and friction evolution in a natural fault are investigated in situ. During three fluid injection experiments at different places in a fault zone, we measured simultaneously the fluid pressure, fault displacements and seismic activity. Changes in fault permeability and friction are then estimated concurrently. Results show that fault permeability increases up to 1.58 order of magnitude as a result of reducing effective normal stress and cumulative dilatant slip, and 19-to-60.8% of the enhancement occurs without seismic emissions. When modeling the fault displacement, we found that a rate-and-state friction and a permeability dependent on both slip and slip velocity together reasonably fit the fault-parallel and fault-normal displacements. This leads to the conclusion that the transient evolution of fault permeability and friction caused by a pressure perturbation exerts a potentially dominant control on fault stability during fluid flow.

58 GEOSCIENCES↗

Sequential Electrochemical Flow Cell for Complex Multicomponent Electrocatalysis

A highly efficient flow cell for sequential electrolysis containing two complete electrochemical cells, capable of generating reactive species at the upstream working electrode and transporting them to the downstream working electrode, is demonstrated. Deconvolution of the intermixed electrode circuits is accomplished through analysis of the inherent resistance of the electrolyte, which allows for precise and independent control of the electrochemical potential at each electrode without altering concentrations of supporting or background electrolyte species. Sequential electrolysis involving oxidation of hydrogen and reduction of the generated protons downstream is demonstrated at nearly 100% efficiency on Pt-decorated dealloyed porous Nb catalysts. The conversion efficiency of the catalysts is discussed in terms of their geometries and active surface composition, elucidating strategies for use of sequential electrolysis cells for fundamental and applied studies.

25 ENERGY STORAGE↗

Post-Closure Monitoring Report for Corrective Action Unit 98, Frenchman Flat, Underground Test Area, Nevada National Security Site, Nevada for Calendar Year 2016 (January 2016–December 2016), Revision 1

Corrective Action Unit (CAU) 98: Frenchman Flat on the Nevada National Security Site was the location of 10 underground nuclear tests. CAU 98 underwent a series of investigations and actions in accordance with the Federal Facility Agreement and Consent Order to assess contamination of groundwater by radionuclides from the tests. A Closure Report completed that process in 2016 and called for long-term monitoring, use restrictions (URs), and institutional controls to protect the public and environment from potential exposure to contaminated groundwater. Three types of monitoring are performed for CAU 98: water quality, water level, and institutional control. These are monitored to determine whether the UR boundaries remain protective of human health and the environment, and to ensure that the regulatory boundary objectives are being met. Monitoring data will be used in the future, once multiple years of data are available, to evaluate consistency with the groundwater flow and contaminant transport models because the contaminant boundaries calculated with the models are the primary basis of the UR boundaries. Six wells were sampled for water-quality monitoring in 2016. Contaminants of concern were detected only in the two source/plume wells already known to contain contamination as a result of a radionuclide migration experiment. The tritium concentration in both wells is slowly decreasing. The water-level monitoring network includes 16 wells. Depth to water measured in 2016 in all wells is consistent with recent measurements. Institutional control monitoring confirmed the URs are recorded in U.S. Department of Energy and U.S. Air Force land management systems, and that no activities within Frenchman Flat basin are occurring that could potentially affect the contaminant boundaries. Survey of groundwater resources in basins surrounding Frenchman Flat similarly identify no current or pending development that would indicate the need to increase monitoring activities or would otherwise cause concern for the closure decision. The URs continue to prevent exposure of the public, workers, and the environment to contaminants of concern by preventing use of potentially contaminated groundwater.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗

Utilizing a Novel Acoustic Backscatter Array to Characterize Waste Consolidation and Settling in a Horizontal Flow Clarifier - 16051

As part of a collaboration between the University of Leeds, Sellafield Ltd and MMI Engineering Ltd, bespoke acoustic instrumentation and numerical simulation methods have been established to optimize nuclear legacy waste transfers. Specifically, a new ultrasonic measurement system has been developed, allowing suspended particle concentration and consolidation to be measured remotely. This technology has been combined with computational fluid dynamics (CFD) modelling of settling particulate systems, permitting full characterization, simulation and prediction of sludge separation processes. Presented here are experimental and numerical results on the transport and settling behavior of non-active nuclear-analogue suspensions in two flow geometries: gravitational settling of glass dispersions in a 250-liter column; and transport and sedimentation of flocculated calcite in a close-to-full-scale clarifier (9 m{sup 3} total volume and 4.8 m{sup 2} length). In addition, details of the design, construction and calibration of a custom-built Ultrasonic Array Research Platform (UARP) are described. Settling column results suggested that particle concentration changes could be simulated with good accuracy by a CFD model (developed using the open source OpenFOAM framework) when compared to measured samples. Large-scale clarifier trials were used to assess the effectiveness of the UARP controller with an attached in situ acoustic backscatter array (ABA). The ABA consisted of 8 transducers angled down at 20 deg. to the vertical, pulsing at 2-2.5 MHz in cycles (covering 1.8 m total depth). In comparison to a range of sampled concentrations across the length of the clarifier, results confirmed that the UARP-ABA system was highly successful at characterizing these complex flows over several hours of operation, allowing visualization of depth-wise bulk density changes and bed build-up over time. Collectively, this work highlights the capability of these tools to monitor and optimize a number of current waste transfer operations at Sellafield, with further potential applications for solid-liquid separations across waste, water treatment and minerals engineering industries. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Active combustion flow modulation valve

A flow modulation valve has a slidably translating hollow armature with at least one energizable coil wound around and fixably attached to the hollow armature. The energizable coil or coils are influenced by at least one permanent magnet surrounding the hollow armature and supported by an outer casing. Lorentz forces on the energizable coils which are translated to the hollow armature, increase or decrease the flow area to provide flow throttling action. The extent of hollow armature translation depends on the value of current supplied and the direction of translation depends on the direction of current flow. The compact nature of the flow modulation valve combined with the high forces afforded by the actuator design provide a flow modulation valve which is highly responsive to high-rate input control signals.

42 ENGINEERING↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using a 3D Porous Flow-Through Electrode Geometry for High-Rate Electrochemical Reduction of CO 2 to CO in Ionic Liquid

Three-dimensional porous flow-through electrodes promise the realization of higher current densities in the electrochemical carbon dioxide reduction reaction (CO 2 RR) by overcoming mass-transport limitations associated with the diffusion of dissolved CO 2 in the bulk electrolyte. Using an ionic-liquid-based electrolyte, [EMIM]BF 4 , offers the additional benefit of higher CO 2 solubility compared to water-based electrolytes. Here, we quantitatively evaluated the effects of flow-driven reactant transport on electrode activity and selectivity for the electrochemical CO 2 RR in [EMIM]BF4. High-surface-area porous flow-through electrodes were fabricated by wet-chemical deposition of Ag nanoflowers on commercial macroporous Al foams. At the highest electrolyte flow-through rate of 100 mL min –1 , we observed a 70-fold increase in partial CO current density, and a 7-fold increase in the Faradaic efficiency toward CO, from 10% without flow to 75% with flow. At the same time, the selectivity changed from oxalate as the main product without flow to CO in the electrolyte flow-through configuration. These results demonstrate that the flow-through approach provides a promising path forward to control selectivity and to overcome mass-transport limitations of the electrochemical CO 2 RR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D characterisation and quantification of an offshore freshened groundwater system in the Canterbury Bight

Although offshore freshened groundwater (OFG) systems have been documented in numerous continental margins worldwide, their geometry, controls and emplacement dynamics remain poorly constrained. Here we integrate controlled-source electromagnetic, seismic reflection and borehole data with hydrological modelling to quantitatively characterise a previously unknown OFG system near Canterbury, New Zealand. The OFG system consists of one main, and two smaller, low salinity groundwater bodies. The main body extends up to 60 km from the coast and a seawater depth of 110 m. We attribute along-shelf variability in salinity to permeability heterogeneity due to permeable conduits and normal faults, and to recharge from rivers during sea level lowstands. A meteoric origin of the OFG and active groundwater migration from onshore are inferred. However, modelling results suggest that the majority of the OFG was emplaced via topographically-driven flow during sea level lowstands in the last 300 ka. Global volumetric estimates of OFG will be significantly revised if active margins, with steep coastal topographies like the Canterbury margin, are considered.

54 ENVIRONMENTAL SCIENCES↗

Ultra Low Density Shape Memory Polymer Foams With Tunable Physicochemical Properties for Treatment of intracranial Aneurysms

Shape memory polymers (SMPs) are a rapidly emerging class of smart materials that can be stored in a deformed temporary shape, and can actively return to their original shape upon application of an external stimulus such as heat, pH or light. This behavior is particularly advantageous for minimally invasive biomedical applications comprising embolic/regenerative scaffolds, as it enables a transcatheter delivery of the device to the target site. The focus of this work was to exploit this shape memory behavior of polyurethanes, and develop an efficient embolic SMP foam device for the treatment of intracranial aneurysms.In summary, this work reports a novel family of ultra low density polymer foams which can be delivered via a minimally invasive surgery to the aneurysm site, actuated in a controlled manner to efficiently embolize the aneurysm while promoting physiological fluid/blood flow through the reticulated/open porous structure, and eventually biodegrade leading to complete healing of the vasculature.

36 MATERIALS SCIENCE↗

Vibration control in accelerators

In the vast majority of accelerator applications, ground vibration amplitudes are well below tolerable magnet jitter amplitudes. In these cases, it is necessary and sufficient to design a rigid magnet support structure that does not amplify ground vibration. Since accelerator beam lines are typically installed at an elevation of 1-2m above ground level, special care has to be taken in order to avoid designing a support structure that acts like an inverted pendulum with a low resonance frequency, resulting in untolerable lateral vibration amplitudes of the accelerator components when excited by either ambient ground motion or vibration sources within the accelerator itself, such as cooling water pumps or helium flow in superconducting magnets. In cases where ground motion amplitudes already exceed the required jiter tolerances, for instance in future linear colliders, passive vibration damping or active stabilization may be considered.

43 PARTICLE ACCELERATORS↗

Self‐Propelling Macroscale Sheets Powered by Enzyme Pumps

Nanoscale enzymes anchored to surfaces act as chemical pumps by converting chemical energy released from enzymatic reactions into spontaneous fluid flow that propels entrained nano‐ and microparticles. Enzymatic pumps are biocompatible, highly selective, and display unique substrate specificity. Utilizing these pumps to trigger self‐propelled motion on the macroscale has, however, constituted a significant challenge and thus prevented their adaptation in macroscopic fluidic devices and soft robotics. Using experiments and simulations, we herein show that enzymatic pumps can drive centimeter‐scale polymer sheets along directed linear paths and rotational trajectories. In these studies, the sheets are confined to the air/water interface. With the addition of appropriate substrate, the asymmetric enzymatic coating on the sheets induces chemically driven, buoyancy flows that controllably propel the sheet's motion on the air/water interface. The directionality and speed of the motion can be tailored by changing the pattern of the enzymatic coating, type of enzyme, and nature and concentration of the substrate. This work highlights the utility of biocompatible enzymes for generating motion in macroscale fluidic devices and robotics and indicates their potential utility for in vivo applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗