Search NASA⌕ Search

SEARCH · Search NASA

Results for “Activity detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

PKS 2155-304 in July 2006: H.E.S.S. results and simultaneous multi-wavelength observations

The high-frequency-peaked BL Lac PKS 2155-304 is one of the brightest and best-studied VHE {gamma}-ray sources in the southern hemisphere. The High Energy Stereoscopic System (H.E.S.S.) has monitored PKS 2155-304 in 2006 and a multi-wavelength campaign involving X-ray, optical and radio observatories was triggered by the detection of an active state in July 2006, followed by the detection of two extraordinary flares on July, 28th and 30th, with peak fluxes {approx}100 times the usual values. We present results from the spectral and flux variability analysis of the VHE and simultaneous X-ray observations with Chandra during the second flare, as well as the detailed evolution of the VHE flux of PKS 2155-304 observed by H.E.S.S. in 2006. A study of flux correlations in the different frequency ranges during the second flare and the adjacent nights is discussed. We also present an interpretation of the active state of PKS 2155-304 in the framework of synchrotron self-Compton emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Thin film gauge

A thin film gauge for use in measuring distributed convective heat transfer rates occurring along given surfaces, is described. The gauge is particularly suited to measuring test surfaces in the air stream of a wind tunnel. The gauge is characterized by a plurality of painted platinum leads extend across the surface of a substrate; a pair of leads on the surface is adapted to deliver an electric current at a constant amperage through a selected thermally active area. Leads are also coupled at opposite sides of the thermally active area for detecting induced voltage drops occurring in the area so that the active length of the gauge is defined between voltage output leads. Changes in heat transfer to the thermally active area are isolated and determined by detecting induces changes in voltage drop.

Mcronald, A. D.↗

Nuclear Security: Quantifying Late Detection in MC&A for Item Inventories

This objectives for this presentation are to understand how physical inventories, sampling plans, and other checks of the inventory factor into detection of insider activity; be able to quantify the probability of detection for various scenarios in a single inventory and over several inventories; and understand how physical inventory and sampling procedures relate to the assumptions, analysis, and scenarios in the vulnerability assessment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nerve cell-mimicking liposomes as biosensor for botulinum neurotoxin complete physiological activity

Botulinum neurotoxins (BoNT) are the most toxic substances known, and their neurotoxic properties and paralysing effects are exploited for medical treatment of a wide spectrum of disorders. To accurately quantify the potency of a pharmaceutical BoNT preparation, its physiological key activities (binding to membrane receptor, translocation, and proteolytic degradation of SNARE proteins) need to be determined. To date, this was only possible using animal models, or, to a limited extent, cell-based assays. We here report a novel in vitro system for BoNT/B analysis, based on nerve-cell mimicking liposomes presenting motoneuronal membrane receptors required for BoNT binding. Following triggered membrane translocation of the toxin's Light Chain, the endopeptidase activity can be quantitatively monitored employing a FRET-based reporter assay within the functionalized liposomes. We were able to detect BoNT/B physiological activity at picomolar concentrations in short time, opening the possibility for future replacement of animal experimentation in pharmaceutical BoNT testing. - Highlights: • A cell-free in vitro system was used to measure BoNT/B physiological function. • The system relies on nerve-cell mimicking liposomes as a novel detection system. • A FRET-based reporter assay is used as final readout of the test system. • BoNT/B physiological activity was detected at picogram quantities in short time. • The method opens the possibility to replace animal experimentation in BoNT testing.

60 APPLIED LIFE SCIENCES↗

Developing a circularly permuted variant of Renilla luciferase as a bioluminescent sensor for measuring Caspase-9 activity in the cell-free and cell-based systems

Highlights: • A luciferase based biosensor for measuring caspase-9 activity has been constructed using circular permutation strategy. • The designed biosensor detects the caspase-9 activity in a cell-free coupled assay system. • The designed biosensor can be implemented as a cell-based biosensor to detect cellular caspase-9 activity and apoptosis. Biosensors and whole cell biosensors consisting of biological molecules and living cells can sense a special stimulus on a living system and convert it to a measurable signal. A major group of them are the bioluminescent sensors derived from luciferases. This type of biosensors has a broad application in molecular biology and imaging systems. In this project, a luciferase-based biosensor for detecting and measuring caspase-9 activity is designed and constructed using the circular permutation strategy. The spectroscopic method results reveal changes in the biosensor structure. Additionally, its activity is examined in a cell-free coupled assay system. Afterward, the biosensor is utilized for measuring the cellular caspase-9 activity upon apoptosis induction in a cancer cell line. In following the gene of biosensor is sub-cloned into a eukaryotic vector and transfected to HEK293T cell line and then its activity is measured upon apoptosis induction in the presence and absence of a caspase-9 inhibitor. The obtained results show that the designed biosensor detects the caspase-9 activity in the cell-free and cell-based systems.

60 APPLIED LIFE SCIENCES↗

Detecting Falling Snow from Space

There is an increased interest in detecting and estimating the amount of falling snow reaching the Earth's surface in order to fully capture the atmospheric water cycle. An initial step toward global spaceborne falling snow algorithms includes determining the thresholds of detection for various active and passive sensor channel configurations, snow event cloud structures and microphysics, snowflake particle electromagnetic properties, and surface types. In this work, cloud resolving model simulations of a lake effect and synoptic snow event were used to determine the minimum amount of snow (threshold) that could be detected by the following instruments: the W -band radar of CloudSat, Global Precipitation Measurement (GPM) Dual-frequency Precipitation Radar (DPR) Ku and Ka band, and the GPM Microwave Imager (GMI) channels from 10 to 183 plus or minus 7 GHz. Eleven different snowflake shapes were used to compute radar reflectivities and passive brightness temperatures. Notable results include: (1) the W-Band radar has detection thresholds more than an order of magnitude lower than the future GPM sensors, (2) the cloud structure macrophysics influences the thresholds of detection for passive channels, (3) the snowflake microphysics plays a large role in the detection threshold for active and passive instruments, (4) with reasonable assumptions, "the passive 166 GHz channel has detection threshold values comparable to the GPM DPR Ku and Ka band radars with approximately 0.05 g per cubic meter detected at the surface, or an approximately 0.5-1 millimeter per hr. melted snow rate (equivalent to 0.5-2 centimeters per hr. solid fluffy snowflake rate). With detection levels of falling snow known, we can focus current and future retrieval efforts on detectable storms and concentrate advances on achievable results. We will also have an understanding of the light snowfall events missed by the sensors and not captured in the global estimates.

Gail Skofronick-Jackson↗

24.1.3.1.1 - Frisch Grid CZT Spectrometer

Brookhaven National Laboratory (BNL) worked with FLIR System Inc., the manufacturer of the nanoRAIDER, to develop a handheld field deployable detector based on the novel position-sensitive virtual Frisch-grid (VFG) Cadmium-Zinc-Telluride (CdZnTe or CZT) detectors (with 1% FWHM at 662 keV or better energy resolution). The detector called nanoRAIDER-VFG would be an improvement to the current nanoRAIDER, which is a compact gamma-ray detection instrument manufactured by FLIR Systems Inc. that employs relatively lower-performing CZT hemispheric detectors (i.e., 3%-FWHM CZT detectors). The nanoRAIDER-VFG would have significantly improved accuracy of measurements while maintaining similar efficiency, as compared to the nanoRAIDER, for in-field analysis of nuclear materials and detection of undeclared activities during inspections conducted by the International Atomic Energy Agency (IAEA). Since the nanoRAIDER is currently used by the IAEA as part of its Complementary Access toolkit, a relatively quick acceptance of the nanoRAIDER-VFG for safeguards was anticipated. The nanoRAIDER-VFG project was undertaken to address the following items in the IAEA's Long-Term R&D Plan, 2012-2023: 2.2 (elemental and isotopic signatures of fuel cycle processes); 2.3 (detect signatures of undeclared activity and improve analysis); and 2.6 (detect process emanations). The high energy-resolution of the nanoRAIDER-VFG would also have had applicability to 3.2 (fissile content of metal mixtures containing actinides Np, Am, etc.). The project was not completed due to a change in priorities within FLIR.

36 MATERIALS SCIENCE↗

Review of current neutron detection systems for emergency response

Neutron detectors are utilized in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 ( 3 He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution. Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 ( 10 B), lithium-6 ( 6 Li), and gadollinium-157 ( 157 Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 ( 4 He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Finally, modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Active Seismic and Electrical Methods to Detect and Characterize Subsurface Effects of an Underground Explosion

During the period of underground nuclear testing in the U.S., now ended for over 20 years, the focus of work was to conduct the test and analyze the data as quickly as possible; there was little concern about application of technologies that could be used to detect and characterize the location and depth of the explosion. Thus, there is little experience with applying geophysical methods in places where an underground nuclear explosion (UNE) has taken place. On the other hand, application of geophysical methods to the detection of shallow artifacts and water table depth is commonly applied in the environmental remediation and site characterization realm of commercial geophysical surveys. For nuclear nonproliferation treaty applications which may incorporate both shallow and deep geophysical probing methods (such as on-site inspection (OSI) under the Comprehensive Nuclear Test Ban Treaty [CTBT]), there thus remains a need to better understand detection capabilities of the deeper targets: anomalies related to an explosion cavity or rubble zone that may be located several hundred meters below the ground surface. The purpose of this Coordinated Inspection Technologies (CIT) project was to gain experience in applying active seismic methods and electrical methods at a site in Nevada where an underground nuclear test (UNE) had been conducted in the past to get a better understanding of the capabilities of these methods for detection and characterization of deep subsurface effects of the explosion.

58 GEOSCIENCES↗

Detection of Special Nuclear Material in Cargo using Continuous Neutron Interrogation and Tension Metastable Fluid Detectors

This paper presents results using a novel technique for detecting special nuclear materials (SNMs) based on interrogation with a continuous beam of 2.45 MeV neutrons coupled with high intrinsic efficiency tensioned metastable fluid detectors (TMFDs) operated in threshold rejection mode. While passive interrogation may be utilized for detecting SNMs such as {sup 239}Pu from their strong spontaneous fission neutron signatures, this is not so for highly-enriched uranium (HEU), the timely detection of which has been identified as a grand challenge by the U.S. Domestic Nuclear Detection Office (DNDO). Active (neutron and/or photon based) interrogation represents the only viable means for detecting HEU either shielded or unshielded within cargo containers. Active interrogation by neutrons or photons leads to unequivocal induced fission based signatures in terms of neutron energy and multiplicity. The main challenge under such circumstances pertains to being able to discern the relatively weak emission signatures from the intense interrogation pulses of neutrons and/or photons. Purdue University together with Sagamore Adams Laboratories, LLC (SAL) has been developing the TMFD sensor system that promises to provide high neutron detection efficiency for fast and thermal neutrons while remaining gamma-beta blind. As described in these references, the TMFD sensor system works on the principle of transient cavitation detection events (CDEs) caused by ionizing particles such as neutrons, alphas and fission fragments in fluids that have been placed in various states of tensioned (sub-zero) pressure states of fluid metastability. Such CDEs result in recordable signatures - both electronically as for conventional detectors, but also in the form of audio-visual signals. One key advantage that the TMFD holds over conventional neutron detectors is that it has proven gamma-beta 'blindness' and indeed, confirmed to possess GARRn = 1.0 to γ photons (tested in up to 10{sup 11} γ/s field from a 3 Ci {sup 137}Cs source). Such an enablement allows for detection without saturation from background, interrogating and fission created γ photons. Another key attribute is up to 60 % intrinsic fission spectrum neutron detection efficiency which, furthermore, is amenable to tailoring for threshold based rejection. That is, to be able to detect neutrons at or above a desired energy with good efficiency, while remaining relatively blind to neutrons below the chosen threshold. This research is the subject of our ongoing DNDO project at Purdue University, the results of which form the basis of this paper. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Behavioral screening of the LOPAC{sup 1280} library in zebrafish embryos

Spontaneous activity represents an early, primitive form of motor activity within zebrafish embryos, providing a potential readout for identification of neuroactive compounds. However, despite use as an endpoint in chemical screens around the world, the predictive power and limitations of assays relying on spontaneous activity remain unclear. Using an improved high-content screening assay that increased throughput from 384 to 3072 wells per week, we screened a well-characterized library of 1280 pharmacologically active compounds (LOPAC{sup 1280}) – 612 of which target neurotransmission – to identify which targets are detected using spontaneous activity as a readout. Results from this screen revealed that (1) 8% of the LOPAC{sup 1280} library was biologically active; (2) spontaneous activity was affected by compounds spanning a broad array of targets; (3) only 4% of compounds targeting neurotransmission impacted spontaneous activity; and (4) hypoactivity was observed for 100% of hits detected, including those that exhibit opposing mechanisms of action for the same target. Therefore, while this assay was able to rapidly identify potent neuroactive chemicals, these data suggest that spontaneous activity may lack the ability to discriminate modes of action for compounds interfering with neurotransmission, an issue that may be due to systemic uptake following waterborne exposure, persistent control variation, and/or interference with non-neurotransmission-related mechanisms. - Highlights: • Assay throughput was increased from 384 to 3072 wells per week. • 8% of the LOPAC{sup 1280} library was biologically active within zebrafish embryos. • Spontaneous activity was affected by compounds spanning a broad array of targets. • Only 4% of compounds targeting neurotransmission impacted spontaneous activity. • Hypoactivity was observed for 100% of hits detected.

60 APPLIED LIFE SCIENCES↗

Tracking Seismic Velocity Perturbations at Ridgecrest Using Ballistic Correlation Functions

Abstract We present results based on data of a dense nodal array composed of 147 stations, deployed in 2022 near the epicenter of the 2019 Mw 7.1 Ridgecrest earthquake to investigate characteristics of the seismic wavefields. Through array analyses, we identified two primary components. First, we observed far-field P waves dominating the 0.5–1.2 Hz frequency range, which are likely primarily generated by wind-driven oceanic swell activity. Second, we detected near-field body waves resulting from anthropogenic activities in the frequency range 2–8 Hz. We examined noise correlation functions derived from data of the dense deployment and regional stations to explore fault-zone seismic velocity changes using ballistic arrivals, with a focus on velocity perturbation shortly before and after the Ridgecrest earthquake sequence. Our findings exhibit distinct behavior compared to results obtained through standard coda-wave interferometry. Particularly, we observed a decrease in P-wave travel time on certain station pairs prior to the 2019 earthquake sequence. Supported by detailed investigation of the local seismic wavefields, we interpret the decreasing P-wave travel time as likely caused by a velocity increase away from the fault, possibly related to fluid migration. However, additional information is necessary to verify this hypothesis.

Geochemistry & Geophysics↗

A Multifunctional Coating for Autonomous Corrosion Control

This slide presentation reviews the effects of corrosion on various structures at the Kennedy Space Center, and the work to discover a corrosion control coating that will be autonomous and will indicate corrosion at an early point in the process. Kennedy Space Center has many environmental conditions that are corrosive: ocean salt spray, heat, humidity, sunlight and acidic exhaust from the Solid Rocket Boosters (SRBs). Presented is a chart which shows the corrosion rates of carbon steel at various locations. KSC has the highest corrosion rates with 42.0 mils/yr, leading the next highest Galeta Point Beach, in the Panama Canal Zone with 27 mils/yr corrosion. A chart shows the changes in corrosion rate with the distance from the ocean. The three types of corrosion protective coatings are described: barrier (passive), Barrier plus active corrosion inhibiting components, and smart. A smart coating will detect and respond actively to changes in its environment in a functional and predictable manner and is capable of adapting its properties dynamically. The smart coating uses microcapsules, particles or liquid drops coated in polymers, that can detect and control the corrosion caused by the environment. The mechanism for a pH sensitive microcapsule and the hydrophobic core microcapsule are demonstrated and the chemistry is reviewed. When corrosion begins, the microcapsule will release the contents of the core (indicator, inhibitor, and self healing agent) in close proximity to the corrosion. The response to a pH increase is demonstrated by a series of pictures that show the breakdown of the microcapsule and the contents release. An example of bolt corrosion is used, as an example of corrosion in places that are difficult to ascertain. A comparison of various coating systems is shown.

Calle, L. M.↗

Predicting transcription factor activity using prior biological information

Dysregulation of normal transcription factor activity is a common driver of disease. Therefore, the detection of aberrant transcription factor activity is important to understand disease pathogenesis. We have developed Priori, a method to predict transcription factor activity from RNA sequencing data. Priori has two key advantages over existing methods. First, Priori utilizes literature-supported regulatory information to identify transcription factor-target gene relationships. It then applies linear models to determine the impact of transcription factor regulation on the expression of its target genes. Second, results from a third-party benchmarking pipeline reveals that Priori detects aberrant activity from 124 single-gene perturbation experiments with higher sensitivity and specificity than 11 other methods. We applied Priori and other top-performing methods to predict transcription factor activity from two large primary patient datasets. Our work demonstrates that Priori uniquely discovered significant determinants of survival in breast cancer and identified mediators of drug response in leukemia.

59 BASIC BIOLOGICAL SCIENCES↗

A multiplexed nanostructure-initiator mass spectrometry (NIMS) assay for simultaneously detecting glycosyl hydrolase and lignin modifying enzyme activities

Lignocellulosic biomass is composed of three major biopolymers: cellulose, hemicellulose and lignin. Analytical tools capable of quickly detecting both glycan and lignin deconstruction are needed to support the development and characterization of efficient enzymes/enzyme cocktails. Previously we have described nanostructure-initiator mass spectrometry-based assays for the analysis of glycosyl hydrolase and most recently an assay for lignin modifying enzymes. Here we integrate these two assays into a single multiplexed assay against both classes of enzymes and use it to characterize crude commercial enzyme mixtures. Application of our multiplexed platform based on nanostructure-initiator mass spectrometry enabled us to characterize crude mixtures of laccase enzymes from fungi Agaricus bisporus (Ab) and Myceliopthora thermophila (Mt) revealing activity on both carbohydrate and aromatic substrates. Using time-series analysis we determined that crude laccase from Ab has the higher GH activity and that laccase from Mt has the higher activity against our lignin model compound. Inhibitor studies showed a significant reduction in Mt GH activity under low oxygen conditions and increased activities in the presence of vanillin (common GH inhibitor). Ultimately, this assay can help to discover mixtures of enzymes that could be incorporated into biomass pretreatments to deconstruct diverse components of lignocellulosic biomass.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ACTIVE GALACTIC NUCLEI IN GROUPS AND CLUSTERS OF GALAXIES: DETECTION AND HOST MORPHOLOGY

The incidence and properties of active galactic nuclei (AGNs) in the field, groups, and clusters can provide new information about how these objects are triggered and fueled, similar to how these environments have been employed to study galaxy evolution. We have obtained new XMM-Newton observations of seven X-ray selected groups and poor clusters with 0.02 < z < 0.06 for comparison with previous samples that mostly included rich clusters and optically selected groups. Our final sample has ten groups and six clusters in this low-redshift range (split at a velocity dispersion of sigma = 500 kms{sup -1}). We find that the X-ray selected AGN fraction increases from f{sub A} (L{sub X} >= 10{sup 41}; M{sub R} <= M*{sub R} + 1) = 0.047{sup +0.023}{sub -0.016} in clusters to 0.091{sup +0.049}{sub -0.034} for the groups (85% significance), or a factor of 2, for AGN above an 0.3-8 keV X-ray luminosity of 10{sup 41}ergs{sup -1} hosted by galaxies more luminous than M*{sub R} + 1. The trend is similar, although less significant, for a lower-luminosity host threshold of M{sub R} = -20 mag. For many of the groups in the sample, we have also identified AGN via standard emission-line diagnostics and find that these AGNs are nearly disjoint from the X-ray selected AGN. Because there are substantial differences in the morphological mix of galaxies between groups and clusters, we have also measured the AGN fraction for early-type galaxies alone to determine if the differences are directly due to environment, or indirectly due to the change in the morphological mix. We find that the AGN fraction in early-type galaxies is also lower in clusters f{sub A,n>}={sub 2.5}(L{sub X} >= 10{sup 41}; M{sub R} <= M*{sub R} + 1) = 0.048{sup +0.028}{sub -0.019} compared to 0.119{sup +0.064}{sub -0.044} for the groups (92% significance), a result consistent with the hypothesis that the change in AGN fraction is directly connected to environment.

79 ASTRONOMY AND ASTROPHYSICS↗