Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Stock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Mutiple Czochralski growth of silicon crystals from a single crucible

An apparatus for the Czochralski growth of silicon crystals is presented which is capable of producing multiple ingots from a single crucible. The growth chamber features a refillable crucible with a water-cooled, vacuum-tight isolation valve located between the pull chamber and the growth furnace tank which allows the melt crucible to always be at vacuum or low argon pressure when retrieving crystal or introducing recharge polysilicon feed stock. The grower can thus be recharged to obtain 100 kg of silicon crystal ingots from one crucible, and may accommodate crucibles up to 35 cm in diameter. Evaluation of the impurity contents and I-V characteristics of solar cells fabricated from seven ingots grown from two crucibles reveals a small but consistent decrease in cell efficiency from 10.4% to 9.6% from the first to the fourth ingot made in a single run, which is explained by impurity build-up in the residual melt. The crystal grower thus may offer economic benefits through the extension of crucible lifetime and the reduction of furnace downtime.

Lane, R. L.↗

Energy Efficiency and Conservation Block Grant (EECBG)- Better Buildings Neighborhood Program Final Report

The original BetterBuildings for Greensboro grant program included an outreach campaign to inform 100% of the Greensboro community about the benefits of reducing energy use; a plan to reduce energy consumption in at least 34% of the homes and 10% of the other buildings in the east Greensboro target area; and a plan to create and retain jobs in the energy conservation industry. Under the original program structure the City of Greensboro planned to partner with local and regional lenders to create a diversified portfolio of loan products to meet the needs of various income levels and building types. All participants would participate in the loan programs as a method of meeting the program’s 5 to1 private capital match/leverage requirements. In June 2011 the program was restructured to include partnerships with large commercial and multifamily projects, with these partners providing the greater portion of the required match/leverage. The geographic focus was revised to include reducing energy consumption across the entire City of Greensboro, targeting neighborhoods with high concentrations of low-moderate income households and aged housing stock. The community outreach component used a neighborhood-based approach to train community residents and volunteers to conduct door-to-door neighborhood sweeps; delivered high quality information on available program resources; helped residents to evaluate alternative energy efficiency measures and alternative financing sources; assisted with contractor selections and monitoring/evaluation of work; coordinated activities with BetterBuildings program partners; and collected data required by the Department of Energy. Additionally, HERO (Home Energy Response Officers) delivered intro packages (energy efficiency information and products) to thousands of households at the initial point of contact. A pilot program (Early Adopters) was offered from March 1, 2011 through June 30, 2011. The Early Adopters program was designed to offer immediate assistance to property owners ready and able to make their homes more energy efficient, by offering a rebate on their energy assessment and on the cost of upgrades installed. Eligible energy efficient upgrades were inclusive of basic level insulating and weather-stripping, HVAC system and water heater upgrades, to whole home upgrades that include the replacement of windows, doors and appliances. Renewable energy systems such as solar hot water systems were also eligible for the rebate program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Energy Impact of Window Technologies for Commercial Buildings

Windows play a significant role in commercial buildings targeting the goal of net zero energy. This report summarizes research methodology and findings in evaluating the energy impact of windows technologies for commercial buildings. The large office prototypical building, chosen from the DOE commercial building benchmarks, was used as the baseline model which met the prescriptive requirements of ASHRAE Standard 90.1-2004. The building simulations were performed with EnergyPlus and TMY3 weather data for five typical US climates to calculate the energy savings potentials of six windows technologies when compared with the ASHRAE 90.1-2004 baseline windows. The six windows cover existing, new, and emerging technologies, including ASHRAE 189.1 baseline windows, triple pane low-e windows, clear and tinted double pane highly insulating low-e windows, electrochromic (EC) windows, and highly insulating EC windows representing the hypothetically feasible optimum windows. The existing stocks based on average commercial windows sales are included in the analysis for benchmarking purposes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Composite beam builder

The building block approach to large space structures is discussed, and the progress made in constructing aluminum beams is noted. It is pointed out that composites will also be required in space structures because they provide minimal distortion characteristics during thermal transients. A composite beam builder currently under development is discussed, with attention given to cap forming and the fastening of cross-braces. The various composite materials being considered are listed, along with certain of their properties. The need to develop continuous forming stock up to 300 m long is stressed.

Poveromo, L. M.↗

Precise Truss Assembly Using Commodity Parts and Low Precision Welding

Hardware and software design and system integration for an intelligent precision jigging robot (IPJR), which allows high precision assembly using commodity parts and low-precision bonding, is described. Preliminary 2D experiments that are motivated by the problem of assembling space telescope optical benches and very large manipulators on orbit using inexpensive, stock hardware and low-precision welding are also described. An IPJR is a robot that acts as the precise "jigging", holding parts of a local structure assembly site in place, while an external low precision assembly agent cuts and welds members. The prototype presented in this paper allows an assembly agent (for this prototype, a human using only low precision tools), to assemble a 2D truss made of wooden dowels to a precision on the order of millimeters over a span on the order of meters. The analysis of the assembly error and the results of building a square structure and a ring structure are discussed. Options for future work, to extend the IPJR paradigm to building in 3D structures at micron precision are also summarized.

Komendera, Erik↗

Controlled Environment Agriculture - Farming and Food Access for Healthy Diets

Fruits and vegetables are critical for a healthy diet and USDA guidelines recommend increasing fruit and vegetable consumption for almost all Americans. However, most food system lifecycle assessments do not capture the importance of these food groups in the food system. Moreover, long supply chains and limited access to fresh produce are particularly prevalent in disadvantaged neighborhoods. Many of these communities are food deserts or food swamps characterized by a lack of full-scale groceries, and a prevalence of convenience stores and fast-food restaurants. Stocking of fresh produce is difficult and often unprofitable for small stores. Convenience stores are usually space-limited, unable to achieve economies-of-scale in purchasing and have difficulty managing the short shelf-life of fresh produce. Controlled-Environment (CE) farming, including greenhouses and fully indoor vertical farms, have the potential to address persistent food access issues for disadvantaged communities. CE farming offers several potential advantages for food desert and food swamp neighborhoods, including shorter or non-existent transport distances and fewer middlemen, which could reduce costs. CE farming can be integrated into existing buildings at virtually any scale, providing local jobs and revitalization of community hubs such as shopping malls, or larger-scale farms located in close-in warehouse or industrial areas. Rainwater harvesting and recovery of nutrients from wastewater could further improve food system resilience and circularity. Geospatial modeling of CE farming in case study cities of various sizes and densities will help to quantify the benefits of CE farming. Geospatial modeling can help to answer questions such as whether sufficient collection area is available for rainwater harvesting for a CE farm, and what size of farm would be required to serve the community living within walking distance of the farm. This paper reports on progress in geospatial modeling of CE farming integration into several case study cities.

controlled environment agriculture↗

Quantifying the statistical importance of utilizing regression over classic energy intensity calculations for tracking efficiency improvements in industry

In the United States, manufacturing facilities account for about 32% of total domestic energy consumption in 2014. Robust energy tracking methodologies are critical to understanding energy performance in manufacturing facilities. Due to its simplicity and intuitiveness, the classic energy intensity method (i.e. the ratio of total energy use over total production) is the most widely adopted. However, the classic energy intensity method does not take into account the variation of other relevant parameters (i.e. product type, feed stock type, weather, etc.). Furthermore, the energy intensity method assumes that the facilities’ base energy consumption (energy use at zero production) is zero, which rarely holds true. Therefore, it is commonly recommended to utilize regression models rather than the energy intensity approach for tracking improvements at the facility level. Unfortunately, many energy managers have difficulties understanding why regression models are statistically better than utilizing the classic energy intensity method. While anecdotes and qualitative information may convince some, many have major reservations about the accuracy of regression models and whether it is worth the time and effort to gather data and build quality regression models. This paper will explain why regression models are theoretically and quantitatively more accurate for tracking energy performance improvements. Based on the analysis of data from 114 manufacturing plants over 12 years, this paper will present quantitative results on the importance of utilizing regression models over the energy intensity methodology. This paper will also document scenarios where regression models do not have significant relevance over the energy intensity method.

Wenning, Thomas↗

Topographic Response to the Yakutat Block Collision

The principal objective of this grant and this research were to investigate the topographic development of an active glaciated orogenic belt in southern Alaska as that development relates to patterns of erosion and crustal deformation. A specific objective of the research was to investigate feedbacks between mountain building, orographic affects on climate, and patterns of exhumation and rock uplift. To that end, an orogen-scale analysis of topography was conducted with the aid of digital elevation models, magnitudes and patterns of crustal deformation were compiled from existing literature, present and past climate patterns were constrained using the modern and past distribution of glaciers, and styles, magnitudes, and extent of erosion were constrained with observations from the 1998 field season.

Stock, Joann M.↗

The Lunar Regolith Terrain (LRT) Field: A New Lunar Surface Planetary Analog Facility at NASA Marshall Space Flight Center (MSFC)

Introduction: NASA is moving toward a new age of exploration and resource utilization of the lunar surface. Challenges related to exploration, resource utilization, and construction at the Lunar South Pole will require advanced technology and well-designed mission concepts and operations. NASA Marshall Space Flight Center (MSFC) has added new capabilities to support surface mobility and construction activities to meet industry, academia, and NASA research and development goals for lunar applications. The Lunar Regolith Terrain (LRT) field is a new, large-area, lunar regolith simulant planetary analog testing ground for users interested in surface mobility and lunar construction activities. The LRT complements NASA MSFC’s other lunar environment testing facilities such as the Lunar Surface Simulator (V20 dirty vacuum chamber), the Lunar Environment Testing System (LETS), among many others. Lunar Regolith Terrain (LTR) Description: The Lunar Regolith Terrain field is an outdoor planetary analog environment facility located on base at MSFC. The lunar regolith simulant is JSC-1A feedstock material (volcanic cinder sand sourced from Meriam Crater, Flagstaff, AZ). The field contains more than 500 tons of lunar regolith simulant confined within a 125 ft x 125 ft (38 m x 38 m) area. The field is placed ~ 50% over paved parking lot and ~ 50% over a natural ground. Currently, the depth of regolith ranges between ~ 5 in - ~ 4 ft (~ 13cm – 1.2m) but can be modified to suit user needs. The lunar regolith simulant that makes up the field has representative geotechnical, geochemical, and optical properties of lunar mare basalt. An area within the LRT of lunar highlands terrain simulant is planned. Additional Features of the LRT: The LRT was designed to allow rapid modification of the terrain’s topography obstacles in the field. The terrain can be reshaped to suit specific testing requirements that may require flat expanses, steep hills, or heavily cratered and rocky landscapes. Large rocky obstacles in Fig. 1 are artificial landscape boulders (faux-rocks) that can be easily placed by users or removed entirely. Areas of the field also contain buried fiducials, large sheets, bar stock, and pipes of various composition and dimensions to allow for possible ground penetrating radar and shallow seismic studies. Rapid modification capabilities will also allow for burial of additional user-specific materials to enable in-situ resource utilization detection (e.g., burial of hydrogen sources for neutron detection or other materials). The field is also equipped with on-site office space with an air-conditioned and heated trailer with 120/240V power and lighting. The site has Wi-Fi and Cellular signal coverage. Direct radio frequency communication with the Huntsville Operations Support Center (HOSC) is in development. Additional on-site workspace and secure equipment storage is available in adjacent buildings. Accessibility to the field is straightforward with on-site parking and access for delivery of instruments, payloads, and additional equipment. Community Availability: The LRTF provides an accessible planetary analog surface environment for surface mobility testing, autonomous roving operations, developing advanced navigation techniques and operations development. Interested parties can contact the abstract authors for additional details, tours, and scheduling.

Lunar Regolith↗

Marshall Space Flight Center: Lunar Regolith Terrain (LRT)

Introduction: NASA is moving toward a new age of exploration and resource utilization of the lunar surface. Challenges related to exploration, resource utilization, and construction at the Lunar South Pole will require advanced technology and well-designed mission concepts and operations. NASA Marshall Space Flight Center (MSFC) has added new capabilities to support surface mobility and construction activities to meet industry, academia, and NASA research and development goals for lunar applications. The Lunar Regolith Terrain (LRT) field is a new, large-area, lunar regolith simulant planetary analog testing ground for users interested in surface mobility and lunar construction activities. The LRT complements NASA MSFC’s other lunar environment testing facilities such as the Lunar Surface Simulator (V20 dirty vacuum chamber), the Lunar Environment Testing System (LETS), among many others. Lunar Regolith Terrain (LTR) Description: The Lunar Regolith Terrain field is an outdoor planetary analog environment facility located on base at MSFC. The lunar regolith simulant is JSC-1A feedstock material (volcanic cinder sand sourced from Meriam Crater, Flagstaff, AZ). The field contains more than 500 tons of lunar regolith simulant confined within a 125 ft x 125 ft (38 m x 38 m) area. The field is placed ~ 50% over paved parking lot and ~ 50% over a natural ground. Currently, the depth of regolith ranges between ~ 5 in - ~ 4 ft (~ 13cm – 1.2m) but can be modified to suit user needs. The lunar regolith simulant that makes up the field has representative geotechnical, geochemical, and optical properties of lunar mare basalt. An area within the LRT of lunar highlands terrain simulant is planned. Additional Features of the LRT: The LRT was designed to allow rapid modification of the terrain’s topography obstacles in the field. The terrain can be reshaped to suit specific testing requirements that may require flat expanses, steep hills, or heavily cratered and rocky landscapes. Large rocky obstacles in Fig. 1 are artificial landscape boulders (faux-rocks) that can be easily placed by users or removed entirely. Areas of the field also contain buried fiducials, large sheets, bar stock, and pipes of various composition and dimensions to allow for possible ground penetrating radar and shallow seismic studies. Rapid modification capabilities will also allow for burial of additional user-specific materials to enable in-situ resource utilization detection (e.g., burial of hydrogen sources for neutron detection or other materials). The field is also equipped with on-site office space with an air-conditioned and heated trailer with 120/240V power and lighting. The site has Wi-Fi and Cellular signal coverage. Direct radio frequency communication with the Huntsville Operations Support Center (HOSC) is in development. Additional on-site workspace and secure equipment storage is available in adjacent buildings. Accessibility to the field is straightforward with on-site parking and access for delivery of instruments, payloads, and additional equipment. Community Availability: The LRTF provides an accessible planetary analog surface environment for surface mobility testing, autonomous roving operations, developing advanced navigation techniques and operations development. Interested parties can contact the abstract authors for additional details, tours, and scheduling.

Lunar Regolith↗

Marshall Space Flight Center: Lunar Regolith Terrain (LRT)

Introduction: NASA is moving toward a new age of exploration and resource utilization of the lunar surface. Challenges related to exploration, resource utilization, and construction at the Lunar South Pole will require advanced technology and well-designed mission concepts and operations. NASA Marshall Space Flight Center (MSFC) has added new capabilities to support surface mobility and construction activities to meet industry, academia, and NASA research and development goals for lunar applications. The Lunar Regolith Terrain (LRT) field is a new, large-area, lunar regolith simulant planetary analog testing ground for users interested in surface mobility and lunar construction activities. The LRT complements NASA MSFC’s other lunar environment testing facilities such as the Lunar Surface Simulator (V20 dirty vacuum chamber), the Lunar Environment Testing System (LETS), among many others. Lunar Regolith Terrain (LTR) Description: The Lunar Regolith Terrain field is an outdoor planetary analog environment facility located on base at MSFC. The lunar regolith simulant is JSC-1A feedstock material (volcanic cinder sand sourced from Meriam Crater, Flagstaff, AZ). The field contains more than 500 tons of lunar regolith simulant confined within a 125 ft x 125 ft (38 m x 38 m) area. The field is placed ~ 50% over paved parking lot and ~ 50% over a natural ground. Currently, the depth of regolith ranges between ~ 5 in - ~ 4 ft (~ 13cm – 1.2m) but can be modified to suit user needs. The lunar regolith simulant that makes up the field has representative geotechnical, geochemical, and optical properties of lunar mare basalt. An area within the LRT of lunar highlands terrain simulant is planned. Additional Features of the LRT: The LRT was designed to allow rapid modification of the terrain’s topography obstacles in the field. The terrain can be reshaped to suit specific testing requirements that may require flat expanses, steep hills, or heavily cratered and rocky landscapes. Large rocky obstacles in Fig. 1 are artificial landscape boulders (faux-rocks) that can be easily placed by users or removed entirely. Areas of the field also contain buried fiducials, large sheets, bar stock, and pipes of various composition and dimensions to allow for possible ground penetrating radar and shallow seismic studies. Rapid modification capabilities will also allow for burial of additional user-specific materials to enable in-situ resource utilization detection (e.g., burial of hydrogen sources for neutron detection or other materials). The field is also equipped with on-site office space with an air-conditioned and heated trailer with 120/240V power and lighting. The site has Wi-Fi and Cellular signal coverage. Direct radio frequency communication with the Huntsville Operations Support Center (HOSC) is in development. Additional on-site workspace and secure equipment storage is available in adjacent buildings. Accessibility to the field is straightforward with on-site parking and access for delivery of instruments, payloads, and additional equipment. Community Availability: The LRTF provides an accessible planetary analog surface environment for surface mobility testing, autonomous roving operations, developing advanced navigation techniques and operations development. Interested parties can contact the abstract authors for additional details, tours, and scheduling.

Lunar Regolith↗

WE-DE-207A-00: Advances in Image-Guided Neurointerventions-Clinical Pull and Technology Push

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-03: Recent Advances in Devices Used in Neuro--Interventions

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-04: Advances in Radiological Neuro-Endovascular Interventional Imaging

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Role of Cyclic Phase Transitions in Additive Manufacturing of Metals and Alloys - Lessons Learned from Welding Science

Additive manufacturing (also known as 3D printing) of metals is considered to be a disruptive technology, able to produce limited number of high value components with topologically optimized geometries and functionalities. Realization of the above potential for real-world applications is stifled by lack of standard computational design tools; component certifications, varied starting powder feed stock compositions, methods to probe thermomechanical processes, microstructural homogeneity, residual stress, as well as, anisotropic static- and dynamic-material properties. Detailed research of direct energy deposition, laser- and electron-powder bed additive manufacturing demonstrates that the underlying physics of these processes are very similar to welding, except for complex boundary conditions. This paper will review published literature and on-going research with reference to fundamental aspects of heat and mass transfer, solidification under large (103 to 105 K/m) thermal gradients and (10-3 to 100 m/s) liquid solid-interface velocities, as well as, solid->solid transformation under repeated thermal excursions. Case studies on model based qualification of Ni- and Ti- alloy builds made by additive manufacturing (AM), based on the above fundamental knowledge will be discussed.

Babu, Sudarsanam Suresh↗

Modeling Framework and Results to Inform Charging Infrastructure Investments

Plug-in electric vehicle (PEV) sales in the United States increased by 40% in 2016, reaching a total stock of over 500,000 vehicles. Still, widespread market adoption of PEVs remains hindered by many factors, including a lack of a convenient and ubiquitous network of charging stations. Understanding the barriers to and benefits of deploying a widespread and effective network of PEV charging stations, also known as electric vehicle supply equipment (EVSE), is particularly important. Such a network would promote PEV consumer acceptance and market growth, enable long-distance travel for BEVs (alleviating the range anxiety concerns of many consumers), and potentially increase the share of electric miles driven by PHEVs. Infrastructure planning must anticipate PEV adoption while remaining cost-effective so low station utilization does not severely undermine the business case for building and operating stations. This project presents an approach for developing a U.S. network of non-residential EVSE that enables broader PEV adoption and maximizes PEV use. This analysis can help inform various public and private stakeholders who are seeking to provide nationwide charging coverage and improve the business case for building stations by maximizing station utilization.

33 ADVANCED PROPULSION SYSTEMS↗