Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The NEID Port Adapter at WIYN: On-Sky Fast Guiding Performance

NEID (NN-explore Exoplanet Investigations with Doppler spectroscopy) is an optical, fiber-fed spectrometer installed on the WIYN 3.5m Telescope. The radial velocity precision that NEID is expected to reach requires the stellar jitter (i.e., the slight irregular movement of the stellar image induced by atmospheric turbulence, wind-shake, etc.) to be controlled within 0.05 arc-seconds 90% of the time in nominal observing conditions (i.e., 0.8-arcsecond seeing and mild winds). To achieve that, the NEID Port Adapter incorporates a fast, first-order wavefront correction system, which implements an Electron-Multiplying CCD camera and a tip/tilt piezo stage to capture and stabilize the stellar image. Here, we use on-sky data to demonstrate the performance of this system under various observing conditions.

Dan Li↗

An Overview of MaGIXS-2: The second flight of the Marshall Grazing Incidence X-ray Spectrometer

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket mission that completed a successful flight from the White Sands Missile Range on July 30, 2021. MaGIXS captured spatially resolved soft X-ray spectra from portions of two solar active regions during its roughly 5-minute flight. The instrument was originally designed as a grazing incidence slit spectrograph but flew in a slit-less configuration that produced overlapping spectroheliograms. For the second flight, MaGIXS-2, the instrument has been reconfigured to a more simplified optical layout that reuses the Wolter-I telescope and blazed varied-line space reflective grating. The field stop at the telescope focal plane and the finite conjugate spectrometer mirror pair have been removed – the telescope now directly feeds the grating. Additionally, an identical but new 2k x 1k CCD camera has been built for this flight. The MaGIXS-2 data product will again be overlapping spectroheliograms of at least one solar active region, but with improved resolution, a larger field of view and increased effective area. Here we present the updated instrument layout, the expected performance, the integration and calibration approach, and proposed future improvements, including the implementation of additional complimentary spectral diagnostics.

Imaging Spectrometer↗

A Historical Overview of the NASA Orbital Debris Program Office’s Laboratory Optical Measurements

The NASA Orbital Debris Program Office (ODPO) has used laboratory measurements to help bring ground-based measurements together with models to ascertain Earth-orbiting target parameters of interest to support various orbital debris models. In 2005, the Optical Measurement Center (OMC) was established to simulate space-based illumination conditions using equipment and techniques that recreate telescopic observations, particularly source-target-sensor orientations. The intent was to recreate light curves using known aspect angles of known targets and phase angles (angle is defined by the vertex between illumination source-object-detector) to complement telescopic observations that could be used to update the current optical size estimation model (OSEM) – a model that converts object brightness into size for orbital debris models. To support the above goals, the laboratory has undergone several equipment upgrades to increase capabilities over almost 20 years of operation. The primary instrumentation acquires reflectance measurements and includes a solar-like light source, CCD camera with astrometric filters, and robotic arm. A rotary arm was added approximately five years after full operation to allow acquisition through a full 360° range of phase angles. Another part of the OMC instrumentation is a field spectrometer, predominately used for field operations to acquire pre- and post-flight spacecraft material spectral measurements. Additionally, reflectance spectroscopy of various materials is also of interest resulting from hypervelocity impact tests, pristine spacecraft materials, or samples of materials that are used in spacecraft design. These measurements are stored in NASA’s Spectral Material Database, a resource that is still being populated today. The study of spectral measurements also enabled the development of spectral unmixing routines to support the identification of spacecraft materials from spectral data gathered by ground based telescopes. Preliminary OMC investigations focused on feasibility studies to acquire 360° rotation light curves of simple shapes at a single-phase angle and extended to measurements of representative fragments from ground-based explosion tests. To correlate the light curves with ground-based optical measurements, a focused study on high area to mass materials was conducted in support of a newly identified population (at the time) in geosynchronous orbit (GEO) consisting of multi-layered insulation. To further characterize orbital debris, a larger selection of materials was analyzed using laboratory photometric measurements that included representative targets from pristine spacecraft materials and ground-based impact tests. Around 2012, an initiative was requested to understand the feasibility of active debris removal (ADR) of larger targets using grappling methods for spent rocket bodies. Using a priori information on selected targets, scaled-down versions of rocket bodies were generated thanks to improvements in 3D printing technology and machining. These targets were studied in the OMC to understand rotation characteristics. These were compared with telescopic data to determine if the tumble and rotation angles would allow ADR. In 2013, the OMC focused on combining spectral measurements with photometric data to characterize GEO orbital debris. Several years later, NASA acquired a Titan III Transtage test article from “The Boneyard” with a high-resemblance to on-orbit Titan III Transtage rocket bodies, allowing physical access to a representative rocket body that suffered fragmentations in GEO. This prompted the creation of 3D models using lidar technology and spectral measurements of the materials. Focused research also transitioned to specific materials (i.e., solar cells) when telescopic surveys requested characterization of specific GEO targets. In the different research products presented, the focus has been to understand the various parameters that influence optical size estimation, including albedo, phase functions, and brightness variations. Work in this area continues with newer sources of data, including DebriSat, a high-fidelity 56-kg spacecraft replica representative of a modern low Earth orbit (LEO) satellite subjected to a laboratory hypervelocity impact test to understand fragmentation events and to support updates to satellite breakup models and size estimation models. Utilizing the vast population of fragments from DebriSat and prior laboratory impact experiments, the ODPO has focused on acquiring bidirectional reflectance distribution function (BRDF) data to characterize targets in the laboratory, thus removing aspect angle dependencies. Additionally, the DebriSat project has provided improved processes for measuring size via image acquisition, such that a true fragment size can be directly compared to the derived size using the OSEM. The team continues to assess BRDFs and use spectral measurement data to investigate the parameters used in the OSEM, specifically magnitudes, albedo, and phase functions.

Heather Cowardin↗

Laser Safety: A Laser Alignment Practical Training Course

SLAC National Accelerator Laboratory has developed a Laser Alignment Practical Training Course as one of its core laser safety classes. The course is taught to small groups of up to three students and takes 1-3 hours to complete. This practical course is not a substitute for site-specific On-the-Job Training; it does, however, provide a good introduction in core laser safety practices that can be broadly applied. Alignment and diagnostic tasks are performed with low power lasers. Students learn safe alignment and diagnostic techniques and how to avoid common mistakes that might lead to an accident. The class is taught by laser supervisors, enabling them to assess the skill level of new laser personnel and determine the subsequent level of supervision needed. The course has six alignment tasks. For each task, discussion points are given for the instructor to review with the students. The optics setup includes different wavelength lasers, a beam expander, mirrors, irises, a periscope, a beam-splitting polarizer and a diffraction grating. Diagnostic tools include viewing cards, an IR viewer and a ccd camera. Laser eyewear is available to block some laser wavelengths in the setup.

43 PARTICLE ACCELERATORS↗

Baseline suppression problems for high precision measurements using optical beam profile monitors

The use of fluorescent screens (e.g. YAG screens) and Optical Transition Radiation (OTR) screens for beam profile monitors provides a simple and widely used way to obtain detailed two dimensional intensity maps. What makes this possible is the availability of relatively inexpensive CCD cameras. For high precision measurements many possible error contributions need to be considered that have to do with properties of the fluorescent screens and of the CCDs. Saturation effects, reflections within and outside the screen, non-linearities, radiation damage, etc are often mentioned. Here we concentrate on an error source less commonly described, namely erroneous baseline subtraction, which is particularly important when fitting projected images. We show computer simulations as well as measurement results having remarkable sensitivity of the fitted profile widths to even partial suppression of the profile baseline data, which often arises from large pixel-to-pixel variations at low intensity levels. Such inadvertent baseline data suppression is very easy to miss as it is usually not obvious when inspecting projected profiles. In this report we illustrate this effect and discuss possible algorithms to automate the detection of this problem as well as some possible corrective measures.

43 PARTICLE ACCELERATORS↗

The Dark Energy Survey Data Management System

The Dark Energy Survey (DES) is a project with the goal of building, installing and exploiting a new 74 CCD-camera at the Blanco telescope, in order to study the nature of cosmic acceleration. It will cover 5000 square degrees of the southern hemisphere sky and will record the positions and shapes of 300 million galaxies up to redshift 1.4. The survey will be completed using 525 nights during a 5-year period starting in 2012. About O(1 TB) of raw data will be produced every night, including science and calibration images. The DES data management system has been designed for the processing, calibration and archiving of these data. It is being developed by collaborating DES institutions, led by NCSA. In this contribution, we describe the basic functions of the system, what kind of scientific codes are involved and how the Data Challenge process works, to improve simultaneously the Data Management system algorithms and the Science Working Group analysis codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Novel Neutron Imaging Calibration System Using a Neutron Generating Accelerator Tube

Neutron Imaging is a key diagnostic for use in inertial confinement fusion (ICF) experiments, and has been fielded on experiments at Omega and Z. It will also be a key diagnostics at the National Ignition Facility (NIF) located at Lawrence Livermore National Laboratory (LLNL) and eventually at the Laser Megajoule in France. Most systems are based on a neutron pinhole array placed at the target chamber while it is imaged by a scintillating fiber block. The light output of this scintillator is coupled via a reducer to a fiber bundle which transports the image to a CCD camera. Alternatively some systems use optical lens assemblies to focus the light onto a camera.For ICF applications the neutron imaging systems will primarily look at 14.2 MeV neutrons. However, 2.2 MeV and 20+ MeV neutrons will also be present and will potentially provide key information.

43 PARTICLE ACCELERATORS↗

Injected Beam Dynamics in SPEAR3

For the top-off operation it is important to understand the time evolution of charge injected into the storage ring. The large-amplitude horizontal oscillation quickly filaments and decoheres, and in some cases exhibits non-linear x-y coupling before damping to the stored orbit. Similarly, in the longitudinal dimension, any mismatch in beam arrival time, beam energy or phase-space results in damped, non-linear synchrotron oscillations. In this paper we report on measurements of injection beam dynamics in the transverse and longitudinal planes using turn-by-turn BPMs, a fast-gated, image-intensified CCD camera and a Hamamatsu C5680 streak camera.

43 PARTICLE ACCELERATORS↗

Transverse Beam Emittance Measurements of a 16 MeV Linac at the Idaho Accelerator Center

A beam emittance measurement of the 16 MeV S-band High Repetition Rate Linac (HRRL) was performed at Idaho State University's Idaho Accelerator Center (IAC). The HRRL linac structure was upgraded beyond the capabilities of a typical medical linac so it can achieve a repetition rate of 1 kHz. Measurements of the HRRL transverse beam emittance are underway that will be used to optimize the production of positrons using HRRL's intense electron beam on a tungsten converter. In this paper, we describe a beam imaging system using on an OTR screen and a digital CCD camera, a MATLAB tool to extract beamsize and emittance, detailed measurement procedures, and the measured transverse emittances for an arbitrary beam energy of 15 MeV.

43 PARTICLE ACCELERATORS↗

Effects of Contact Angle Hysteresis on Ice Adhesion and Growth over Superhydrophobic Surfaces under Dynamic Flow Conditions

In this paper, the iceophobic properties of superhydrophobic surfaces are investigated under dynamic flow conditions by using a closed loop low-temperature wind tunnel. Superhydrophobic surfaces were prepared by coating the substrates of aluminum and steel plates with nano-structured hydrophobic particles. The superhydrophobic plates along with uncoated control ones were exposed to an air flow of 12 m/s and 20 F accompanying micron-sized water droplets in the icing wind tunnel and the ice formation and accretion were probed by high-resolution CCD cameras. Results show that the superhydrophobic coatings significantly delay the ice formation and accretion even under the dynamic flow condition of the highly energetic impingement of accelerated super-cooled water droplets. It is found that there is a time scale for this phenomenon (delay of the ice formation) which has a clear correlation with the contact angle hysteresis and the length scale of surface roughness of the superhydrophobic surface samples, being the highest for the plate with the lowest contact angle hysteresis and finer surface roughness. The results suggest that the key parameter for designing iceophobic surfaces is to retain a low contact angle hysteresis (dynamic property) and the non-wetting superhydrophobic state under the hydrodynamic pressure of impinging droplets, rather than to only have a high contact angle (static property), in order to result in efficient anti-icing properties under dynamic conditions such as forced flows.

36 MATERIALS SCIENCE↗

Real-time Studies of Shocked Polycrystalline Materials with Single-Pulse X-ray Diffraction

Characteristic K-α x-rays used for single-pulse XRD are conventionally produced by a 37-stage high-voltage Marx pulse generator coupled to a vacuum needle-and-washer x-ray diode via coaxial transmission line. A large field-of-view x-ray image plate detection system typically enables observation of several Debye-Scherrer rings. Recently, we have developed a fiber-optic reducer, coupled to a CCD camera, to obtain low-noise, large field-of-view images. The direct beam spot is produced by bremsstrahlung radiation attenuated by a twomillimeter tungsten beam stop. Determination of the direct beam position is necessary to perform the ring integration.

36 MATERIALS SCIENCE↗

Optical Synchrotron Radiation Beam Imaging with a Digital Mask

We have applied a new imaging/optical masking technique, which employs a digital micro-mirror device (DMD) and optical synchrotron radiation (OSR), to perform high dynamic range (DR) beam imaging at the JLAB Energy Recovery Linac and the SLAC/SPEAR3 Synchrotron Light Source. The OSR from the beam is first focused onto the DMD to produce a primary image; selected areas of this image are spatially filtered by controlling the state of individual micro-mirrors; and finally, the filtered image is refocused onto a CCD camera. At JLAB this technique has been used successfully to view the beam halo with a DR ~ 105. At SPEAR3 the DMD was used to filter out the bright core of the stored beam to study the turn-by-turn dynamics of the 10-3 weaker injected beam. We describe the optical performance, present limitations and our plans to improve the DR of both experimental systems.

43 PARTICLE ACCELERATORS↗

Hand-held portable microarray reader for biodetection

A hand-held portable microarray reader for biodetection includes a microarray reader engineered to be small enough for portable applications. The invention includes a high-powered light-emitting diode that emits excitation light, an excitation filter positioned to receive the excitation light, a slide, a slide holder assembly for positioning the slide to receive the excitation light from the excitation filter, an emission filter positioned to receive the excitation light from the slide, a lens positioned to receive the excitation light from the emission filter, and a CCD camera positioned to receive the excitation light from the lens.

47 OTHER INSTRUMENTATION↗

X-ray Diffraction and Multi-Frame Phase Contrast Imaging Diagnostics for IMPULSE at the Advanced Photon Source

The diagnostic needs of any dynamic loading platform present unique technical challenges that must be addressed in order to accurately measure in situ material properties in an extreme environment. The IMPULSE platform (IMPact system for Ultrafast Synchrotron Experiments) at the Advanced Photon Source (APS) is no exception and, in fact, may be more challenging, as the imaging diagnostics must be synchronized to both the experiment and the 60 ps wide x-ray bunches produced at APS. The technical challenges of time-resolved x-ray diffraction imaging and high-resolution multi-frame phase contrast imaging (PCI) are described in this paper. Example data from recent IMPULSE experiments are shown to illustrate the advances and evolution of these diagnostics with a focus on comparing the performance of two intensified CCD cameras and their suitability for multi-frame PCI. The continued development of these diagnostics is fundamentally important to IMPULSE and many other loading platforms and will benefit future facilities such as the Dynamic Compression Sector at APS and MaRIE at Los Alamos National Laboratory.

IMPULSE, x-ray, diffraction, PCI, imaging↗

The CG-1D neutron imaging beamline at the Oak Ridge National Laboratory High Flux Isotope Reactor

The Oak Ridge National Laboratory Neutron Sciences Directorate has installed a neutron imaging beamline at the High Flux Isotope Reactor (HFIR) cold guide hall. CG-1D is one of the three instruments that make up the CG1 instrument suite. The beamline optics and detector have recently been upgraded to meet the needs of the neutron imaging community (better smoothing of guide system artifacts, higher flux or spatial resolution). These upgrades comprise a new diffuser/aperture system, two new detectors, a He-filled flight tube and silicon (Si) windows. Shielding inside the flight tube, beam scrapers and a beam stop ensure that biological dose is less than 50 Sv/hr outside of the radiation boundary. A set of diffusers and apertures (pinhole geometry) has been installed at the exit of the guide system to allow motorized L/D variation. Samples sit on a translation/rotation stage for alignment and tomography purposes. Detectors for the CG-1D beamline are (1) an ANDOR DW936 charge coupled device (CCD) camera with a field of view of approximately 7 cm x 7 cm and ~ 80 microns spatial resolution and 1 frame per second time resolution, (2) a new Micro-Channel Plate (MCP) detector with a 2.8 cm x 2.8 cm field of view and 55 microns spatial resolution, and 5 s timing capability. 6LiF/ZnS scintillators of thickness varying from 50 to 200 microns are being used at this facility. An overview of the beamline upgrade and preliminary data is presented here.

Santodonato, Louis J↗

Observations of Coherent Optical Transition Radiation Interference Fringes Generated by Laser Plasma Accelerator Electron Beamlets

We report initial observations of coherent optical transition radiation interferometry (COTRI) patterns generated by microbunched electrons from laser-driven plasma accelerators (LPAs). These are revealed in the angular distribution patterns obtained by a CCD camera with the optics focused at infinity, or the far-field, viewing a Wartski two-foil interferometer. The beam divergences deduced by comparison to results from an analytical model are sub-mrad, and they are smaller than the ensemble vertical beam divergences measured at the downstream screen of the electron spectrometer. The transverse sizes of the beamlet images were obtained with focus at the object, or near field, and were in the few-micron regime as reported by LaBerge et al. [8]. The enhancements in intensity are significant relative to incoherent optical transition radiation (OTR) enabling multiple cameras to view each shot. We present two-foil interferometry effects coherently enhanced in both the 100-TW LPA at 215 MeV energy at Helmholtz-Zentrum Dresden-Rossendorf and the PW LPA at 1.0-GeV energy at the University of Texas-Austin. A transverse emittance estimate is reported for a microbunched beamlet example generated within the plasma bubble.

43 PARTICLE ACCELERATORS↗

Water Scintillation under Proton Beam Exposure

Ionizing radiation has been accepted as an effective way to treat cancer patients by killing malignant tumors through localized energy deposition. Intensity modulated proton therapy is an advanced radiation delivery technique that provides a highly conformal dose, which converges to the target with less integral dose to normal tissue and organs. Radiation therapy treatments all require an extensive quality assurance (QA) program to ensure that the patient treatment plan is safe and could achieve its objective. Part of this process requires measuring and validating that the dose is reaching the target accurately and with the proper dose. Established QA methods are either costly, inconvenient or time consuming. Scintillation of water when exposed to gamma rays and electron beams has been observed and several QA methods have proposed to take advantage of this phenomena. The water scintillation phenomenon has recently been observed for proton beams as well. This study measured the light produced by proton beam passing water using a cooled charged-coupled device (CCD) camera and demonstrated how these finding could be used to develop a low-cost, efficient, and accurate QA process to verify proton beam spot location, spot shape, and 3D dose distribution. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗