Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Generation of solitary waves from continuous radiation in a nonlinear oppositely directed coupler

We consider a nonlinear coupler formed by two tunnelcoupled waveguides, one waveguide being made of a conventional dielectric and the other – of a negative-index material. The possibility of the formation of solitary waves from continuous radiation having a constant intensity is shown provided that the radiation is coupled into the input of a negative-index coupler channel (on the back side of the waveguide system). With increasing intensity of the input light, the speed and amplitude of the generated solitary waves increase and the period of their formation is reduced. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-474: Improvements to Intra-Oral Shield Design for Electron Beam Treatments: Use of Multi-Layered Metal Foils

Purpose: Intraoral electron shields used in radiotherapy are designed to minimize radiation exposure to non-treatment tissue. Sites where shields are used include but are not limited to, the treatment of lips, cheeks and ears whilst shielding the underlying oral cavity, tongue, gingival or temporal region. However their use produces an enhancement in dose on the beam side caused by an increase in electron backscatter radiation. This work designs a new shield incorporating copper, aluminium and wax in a step down filter arrangement to minimise backscatter whilst minimizing overall shield thickness. Methods: For electron beams ranging from 6 MeV to 10 MeV, shields of varying designs and thicknesses were assessed to determine the thinnest shield design that could be produced whilst minimising backscattered radiation to a clinically acceptable level. This was performed with conventional lead and wax shields as well as varying quantities of aluminium and copper foils. Results: From tested shield designs, a new shield design of 4 mm lead, 0.6 mm copper, 1.0 mm aluminium and 1.5 mm wax (3.1 mm added filtration, 7.1 mm total thickness) provided a clinically acceptable (no greater than 110% dose) backscatter and transmission reduction and matched a standard 4.5 mm lead and 10 mm wax (total thickness 14.5 mm) electron shield. Dose enhancement values of no more than 10 % were measured utilising this shield design with a 50 % reduction in shield thickness. Conclusion: The thinner layered shield reduced backscattered radiation dose to less than 10% enhancement for beam energies on 10 MeV and less and will allow easier patient set up. The thinner shields are tolerated better by patients when mucosal reactions occur as they place less physical pressure on these sites during treatment due to their smaller size and thickness.

60 APPLIED LIFE SCIENCES↗

Evaluation of TiO{sub 2} and TiO{sub 2}/Au nanoparticles as a Potential Radiosensitizers by Decomposition of Methylene Blue

Nanomaterials are constantly used in several applications of science and engineering. Nanoparticles are currently utilized in computer circuits, clothes, luminescent devices, catalysis, medicine, among many others uses. In the clinical field nanomaterials have become an innovative alternative for early diagnosis and treatment of a significant number of medical conditions. Nanoparticles can be utilized in applications ranging from contrast agents for imaging purposes to carriers for drug delivery in cancerous tumors. The use of nanoparticles made of high atomic number elements as noble metals, is becoming an attractive approach for enhancing the radiation dose delivered to a tissue during radiation therapy. The enhancement effect that makes the cells more sensitive to radiation is known as radiosensitization. Materials such as gold (Au) and titanium dioxide (TiO{sub 2}) at the nanoscale have become promising radiosensitizers. When TiO{sub 2} is irradiated with high energy photons, electron-holes are created within the material. This species interacts with surrounding medium generating reactive oxygen species (ROS). ROS create a toxic environment for cancerous cells, ultimately causing their death. On the other hand gold has a different interaction with ionizing radiation. Upon radiation, gold releases a spray of secondary products such as photoelectrons, auger electrons, and characteristic X-rays. The energy created by the escaping electrons leads to DNA strands breaks in the cells causing their death. Therefore, if these nanoparticles are initially accumulated in the tissue to be treated, the dose delivered during radiation therapy is amplified. This represents a synergistic approach to enhance radiation therapy while substantially reducing side effects. Radiosensitization by nanoparticles often depends on their particle size, morphology and synthesis route. The most commonly used methods to synthesize metallic nanoparticles such as gold involves chemical reduction of a metal precursor. In this case, reducing agents are used in order to transform the metallic ions to metal atoms that will subsequently coalesce and grow to form the nanoparticles . Nevertheless there are alternative methods that do not require a chemical reducing agent. Radiation synthesis is one of those processes. The interaction of ionizing radiation with an aqueous solution containing a metal precursor, leads to a phenomena known as radiolysis of water. Radiolysis of water produces chemical species such as solvated electrons (e{sup -}{sub aq}), and hydrogen atoms (H{sup +}). These species are strong reducing agents that bring the metal ions existing in solution into stable metal atoms that will form nanoparticles. Radiation synthesis is a novel method that offers significant advantages over conventional approaches such as wet chemistry routes. In this approach, no further chemical reducing agents are needed, thus it does not generate byproducts that may affect the nanoparticles properties. This is particularly important in medical applications. Furthermore, this technique is designed to work at room temperature and under atmospheric pressures. Nonetheless the most outstanding feature of radiation synthesis is the possibility to control the particle size and size distribution. This route allows for narrow particle size distributions with size ranging from 2 to 30 nm. Furthermore, the availability of different ionizing radiation producing devices such as synchrotrons, X-ray irradiators, and gamma irradiators enables the possibility of manufacturing nanomaterials under various conditions. In this work, Au nanoparticles were deposited onto TiO{sub 2} using the radiation synthesis method. In addition, the radiosensitization characteristics of TiO{sub 2} and TiO{sub 2}/Au nanoparticles were evaluated through the decomposition of the organic dye Methylene Blue (MB). In order to analyze the degradation of the dye the TiO{sub 2} and TiO{sub 2}/Au nanoparticles were placed in an aqueous solution along with MB and subjected to X-ray irradiation. The samples were irradiated for 30 and 60 minutes. The degradation of the MB after irradiation in the presence and absence of the nanomaterials was measured by UV-Vis spectroscopy following the decrease in the absorbance of the dye at 664 nm. (authors)

36 MATERIALS SCIENCE↗

Mechanism of acoustically induced diffusional structuring of surface adatoms

Physical mechanisms of time-averaged structuring of adatoms induced by a standing surface acoustic wave (SAW) on a solid substrate are studied. Despite some similarity with conventional mechanisms based on averaging of fast oscillation-type motion or radiation-pressure effects, we demonstrate that, for diffusional (i.e., strongly damped) adatom motion, the origin of time-averaged structuring is essentially different. The proposed analytical model and kinetic Monte–Carlo (kMC) simulations reveal several distinct structuring regimes and directly relate them to the transient modification of diffusion barriers and adiabatic temperature variations induced by SAW strains.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Making Every Microgram Count: Nanocalorimetry for Nuclear and Ultra-Rare Materials

The thermal analysis of nuclear and ultra-rare materials plays an important role in nuclear energy, planetary, environmental, and technological settings. Heat effects associated with the sample temperature, heat capacity, phase transformation, radiation damage and crystallographic defects are some of the thermochemistry measurements made with conventional differential scanning calorimeters. However, the measurement capabilities of the of traditional DSCs are often restricted when studying limited ultra-rare accessory minerals or materials submitted to extreme conditions, such as radiation in the nuclear fuel cycle and high pressure. We investigate the usage of nanocalorimetry for the energetic analysis of nuclear or ultra-rare materials, such as irradiated materials and high-pressure phases, with an emphasis on radiation damage and heat capacity measurements. Examples of how nanocalorimetry has been previously used for phase transitions, melting, and nucleation in ultra-fast heating and cooling rates are presented. Finally, an outlook of the field and future work, including beneficial safety and environmental outcomes from the potential usage of nanocalorimetry, are shown.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reproducible radiation-damage processes in proteins irradiated by intense x-ray pulses

X-ray free-electron lasers have enabled femtosecond protein nanocrystallography, a novel method to determine the structure of proteins. It allows time-resolved imaging of nanocrystals that are too small for conventional crystallography. The short pulse duration helps in overcoming the detrimental effects of radiation damage because x rays are scattered before the sample has been significantly altered. It has been suggested that, fortuitously, the diffraction process self-terminates abruptly once radiation damage destroys the crystalline order. Our calculations show that high-intensity x-ray pulses indeed trigger a cascade of damage processes in ferredoxin crystals, a particular metalloprotein of interest. However, we found that the damage process is initially not completely random. Correlations exist among the protein monomers, so that Bragg diffraction still occurs in the damaged crystals, despite significant atomic displacements. Our results show that the damage process is reproducible to a certain degree, which is potentially beneficial for the orientation step in single-molecule imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating Mesoscale Convective Systems Over the US in Conventional and Multiscale Modeling Framework Configurations of E3SMv1

Organized mesoscale convective systems (MCSs) contribute a significant amount of precipitation in the Central and Eastern US during spring and summer, which impacts the availability of freshwater and flooding events. However, current global Earth system models cannot capture MCSs well and misrepresent the statistics of precipitation in the region. In this study, we investigate the representation of MCSs in three configurations of the Energy Exascale Earth System Model (E3SMv1) by tracking individual storms based on outgoing longwave radiation using a new application of TempestExtremes. Our results indicate that conventional parameterizations of convection, implemented in both low (LR; ~150 km) and high (HR; ~25 km) resolution configurations, fail to capture almost all MCS-like events, in-part because they underestimate high-level cloud ice associated with deep convection. On the other hand, the multiscale modeling framework (MMF; cloud-resolving models embedded in each grid-column of ~150 km resolution E3SMv1) configuration represents MCSs and their annual cycle better. Nevertheless, relative to observations, the E3SMv1-MMF spatial distribution of MCSs and associated precipitation is shifted eastward, and the diurnal timing is lagged. A comparison between the large-scale environment in E3SMv1-MMF and ERA5 reanalysis suggests that the biases during the summer in E3SMv1-MMF are associated with biases in low-level humidity and meridional moisture transport within the low-level jet. The fact that conventional parameterizations of convection, even with high-resolution, cannot capture MCSs over the US suggests that methods with explicit representation of kilometer-scale convective organization, such as the MMF, may be necessary for improving the simulation of these convective systems.

54 ENVIRONMENTAL SCIENCES↗

Tumor Volume Changes on 1.5 Tesla Endorectal MRI During Neoadjuvant Androgen Suppression Therapy for Higher-Risk Prostate Cancer and Recurrence in Men Treated Using Radiation Therapy Results of the Phase II CALGB 9682 Study

Purpose: We prospectively determined whether the change in tumor volume (TV) during 2 months of neoadjuvant androgen suppression therapy (nAST) measured using conventional 1.5 Tesla endorectal magnetic resonance imaging (eMRI) was associated with the risk of recurrence after radiation (RT) and 6 months of AST. Patients and Methods: Between 1997 and 2001, 180 men with clinical stage T1c-T3cN0M0 adenocarcinoma of the prostate were registered. Fifteen were found to be ineligible and the institutional MR radiologist could not assess the TV in 32, leaving 133 for analysis. Multivariable Cox regression analysis was used to assess whether a significant association existed between eMRI-defined TV progression during nAST and time to recurrence adjusting for prostate-specific antigen (PSA) level, Gleason score (8 to 10 or 7 vs. 6 or less) and stage (T3 vs. T1-2). Results: After a median follow up of 6.7 years and adjusting for known prognostic factors, there was a significant increase in the risk of PSA failure (HR, 2.3 [95% CI, 1.1-4.5; p = 0.025) in men with eMRI-defined TV progression during nAST. Specifically, adjusted estimates of PSA failure were significantly higher (p = 0.032) in men with, compared with men without, eMRI-defined TV progression reaching 38% vs. 19%, respectively, by 5 years. Conclusion: Eradicating intraprostatic hormone refractory prostate cancer (HRPC) by maximizing local control and randomized trials assessing whether survival is improved when agents active against HRPC are combined with maximal local therapy are needed in men who progress based on eMRI during nAST.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of switching to the ICRP-74 neutron flux-to-dose equivalent rate conversion factors at the Sandia National Laboratory Building 818 Neutron Source Range.

Sandia National Laboratories (SNL) maintains a neutron calibration facility which supports the calibration, maintenance, and repair of Radiation Protection Instruments. The SNL neutron reference fields are calibrated using the following methodology: Fluence rate is initially established by calculation using the NIST traceable source emission rate (decay corrected). Correction factors for the effects of room return or scatter, and source anisotropy are then developed by using a suitable radiation transport code to model the geometry of the facility. The conventionally true neutron dose rates are then determined using the appropriate fluence-todose equivalent conversion coefficients at several reference positions. This report describes the impact on calculated neutron dose rates of switching from NCRP-38 to CRP-74 neutron flux-todose equivalent rate conversion factors. This switch is driven by recent changes to dosimetry requirements addressed in 10 CFR 835 (Occupational Radiation Protection).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Use of a Gamma Ray Imaging Device for In-Cell Assay

Gamma ray imaging has become an established technique within the nuclear industry, especially within the field of decommissioning. The technique is most commonly used to identify the origins of radiation within contaminated environments in order to provide a level of characterisation that is not possible using conventional dosemeters. Gamma ray images demonstrate, in a clear, easy to understand format, where there are significant sources of gamma emitting radiation. These images are often used to help determine decontamination, decommissioning or clean-up strategies. Recent developments at Sellafield, in the UK, have demonstrated how gamma ray imaging devices can be used to perform in-cell, quantitative, assay. A data collection and analysis procedure has been developed that can be used to produce activity values for gamma bearing items. The technique is of especial value as the items of interest can be located in cells with limited or no man access, either due to poor physical access or high dose rates. This quantitative assay technique can be used to segregate wastes in-situ, allowing only wastes meeting user-specified criteria to be selected. This paper describes two successful applications of this newly developed technique on the Sellafield site. The technique is covered by European Patent - EP1315004A1 and US Patent - US7095030B2. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-335: Dosimetric Investigation of An Advanced Rotating Gamma Ray System for Imaged Guided Radiation Therapy

Purpose: Co-60 beams have unique dosimetric properties for cranial treatments and thoracic cancers. The conventional concern about the high surface dose is overcome by modern system designs with rotational treatment techniques. This work investigates a novel rotational Gamma ray system for image-guided, external beam radiotherapy. Methods: The CybeRT system (Cyber Medical Corp., China) consists of a ring gantry with either one or two treatment heads containing a Gamma source and a multileaf collimator (MLC). The MLC has 60 paired leaves, and the maximum field size is either 40cmx40cm (40 pairs of 0.5cm central leaves, 20 pairs of 1cm outer leaves), or 22cmx40cm (32 pairs of 0.25cm central leaves, 28 pairs of 0.5cm outer leaves). The treatment head(s) can swing 35° superiorly and 8° inferiorly, allowing a total of 43° non-coplanar beam incident. The treatment couch provides 6-degrees-of-freedom motion compensation and the kV cone-beam CT system has a spatial resolution of 0.4mm. Monte Carlo simulations were used to compute dose distributions and compare with measurements. A retrospective study of 98 previously treated patients was performed to compare CybeRT with existing RT systems. Results: Monte Carlo results confirmed the CybeRT design parameters including output factors and 3D dose distributions. Its beam penumbra/dose gradient was similar to or better than that of 6MV photon beams and its isocenter accuracy is 0.3mm. Co-60 beams produce lower-energy secondary electrons that exhibit better dose properties in low-density lung tissues. Because of their rapid depth dose falloff, Co-60 beams are favorable for peripheral lung tumors with half-arc arrangements to spare the opposite lung and critical structures. Superior dose distributions were obtained for head and neck, breast, spine and lung tumors. Conclusion: Because of its accurate dose delivery and unique dosimetric properties of C-60 sources, CybeRT is ideally suited for advanced SBRT as well as conventional RT. This work was partially supported by Cyber Medical Corp.

60 APPLIED LIFE SCIENCES↗

SU-E-T-34: An in Vivo Study On Pulsed Low Dose-Rate Radiotherapy for Prostate Cancer

Purpose: Re-irradiation with conventional radiotherapy techniques (CRT) may pose significant risks due to high accumulative radiation doses. Pulsed low dose-rate radiotherapy (PLDR) has been used in clinical trials for recurrent cancer treatment. In our previous studies, PLDR irradiation showed significantly lower toxicity than CRT, resulting in much longer survival of mice after PLDR total body irradiation (TBI) than conventional TBI. The purpose of this study was to investigate tumor control efficacy of PLDR treatment for prostate cancer with an animal model of prostate cancer LNCaP. Methods: We used an orthotopic murine model of LNCaP cell line for this study. LNCaP cells were implanted into immune-suppressed male nude mice via surgery. We monitored the tumor growth with MRI. The tumor-bearing mice were allocated into a PLDR(n=9), CRT(n=7), and control group(n=7) randomly. The mice in the PLDR and CRT groups were irradiated with 2Gy dose for one time. For the CRT treatment, the mice received 2Gy at a dose-rate of 300 MU/minute. For the PLDR treatment, the 2Gy dose was further divided into ten pulses of 0.2Gy at the same dose-rate with an interval of 3 minutes between the pulses. Results: Sizable tumor growth delays were observed for the PLDR and CRT groups through weekly MRI scans. The mean values of the normalized tumor volumes (± standard deviation of the mean) were 1.53±0.07, 1.53±0.14, and 1.81±0.09 at one week after treatment, 2.28±0.13, 2.19±0.16, and 3.04±0.25 at two weeks after treatment, and 3.31±0.23, 3.14±0.24 and 4.62±0.49 at three weeks after treatment, for the PLDR, CRT, and control groups, respectively. Conclusion: The PLDR and CRT treatments showed comparable tumor control rates in this study. Our in vivo results indicate that PLDR may be a viable option for treating recurrent prostate cancer due to its equivalent tumor control but low normal tissue toxocities.

60 APPLIED LIFE SCIENCES↗

Nuclear Thermal Rocket (NTR) Development Risk Communication

There are clear advantages of development of a Nuclear Thermal Rocket (NTR) for a crewed mission to Mars. NTR for in-space propulsion enables more ambitious space missions by providing high thrust at high specific impulse (approximately 900 sec) that is 2 times the best theoretical performance possible for chemical rockets. Missions can be optimized for maximum payload capability to take more payload with reduced total mass to orbit; saving cost on reduction of the number of launch vehicles needed. Or missions can be optimized to minimize trip time significantly to reduce the deep space radiation exposure to the crew. NTR propulsion technology is a game changer for space exploration. However, "NUCLEAR" is a word that is feared and vilified by some groups and the hostility towards development of any nuclear systems can meet great opposition by the public as well as from national leaders and people in authority. Communication of nuclear safety will be critical to the success of the development of the NTR. Why is there a fear of nuclear? A bomb that can level a city is a scary weapon. The first and only times the Nuclear Bomb was used in a war was on Hiroshima and Nagasaki during World War 2. The "Little Boy" atomic bomb was dropped on Hiroshima on August 6, 1945 and the "Fat Man" on Nagasaki 3 days later on August 9th. Within the first 4 months of bombings, 90- 166 thousand people died in Hiroshima and 60-80 thousand died in Nagasaki. It is important to note for comparison that over 500 thousand people died and 5 million made homeless due to strategic bombing (approximately 150 thousand tons) of Japanese cities and war assets with conventional non-nuclear weapons between 1942- 1945. A major bombing campaign of "firebombing" of Tokyo called "Operation Meetinghouse" on March 9 and 10 consisting of 334 B-29's dropped approximately1,700 tons of bombs around 16 square mile area and over 100 thousand people have been estimated to have died. The declaration of death is very clear for conventional weapons and then the declaration of death due to radiation becomes vague and unclear. This may have been due to people mis-understanding the dangers and effects of radiation when assessing the damage and harm to people initially, but it is also become insidious when expressing opposition to nuclear energy. A nuclear radiation accident can be scary due to the power involved and the fear of radiation release. The International Atomic Energy Agency defines a nuclear and radiation accident a "an event that has led to significant consequences to people, the environment or the facility." There have been 3 commercial nuclear reactor accidents (Chernobyl, Three Mile Island, and Fukushima) that stand out to the public and much of the information about the result and impact to workers, environment, and public can be misleading. Often information is presented without clear correlation with radiation and other pertinent information is left out presenting a very scary situation to affect the emotions of the reader. A very boring but "critically acclaimed" movie was made in 1979 called "The China Syndrome" starring Jane Fonda and Jack Lemmon. The film was released on March 16, 1979, 12 days before the 3-Mile Island nuclear accident in Pennsylvania. The basis from the movie was from a few nuclear plant incidents and in particular, the Brown's Ferry Alabama Power Plant fire. In one scene from the movie, a physicist Dr. Elliott Lowell played by Donald Hotton states that a China Syndrome event would make "an area the size of Pennsylvania" permanently uninhabitable. Real serious nuclear incidents like Chernobyl and Fukushima are often sited to make people fear the consequences of using nuclear power. However, the consequences are at best poorly communicated and at worst fictitiously inflated to instigate social unrest against nuclear power. There is an article being circulated on Facebook with a title "28 Signs that the (US) West Coast is being absolutely fried with nuclear radiation from Fukushima" which focus on mis-information and fear mongering. Nuclear power and NTR are powerful resources that can open many doors for future prosperity and capability. With great power comes great responsibility. Radiation and its effects need to be better understood, quantified, and communicated. A human mission to mars has its own risks of deep space radiation and is considered a considerable risk at 400 milli-Sieverts per year in deep space and 245 milli-Sieverts per year on the surface of Mars as measured by the Mars Curiosity mission. Although these quantities of ionizing radiation are within the astronaut career limit, it exceeds the yearly average amounts of ionizing radiation. Astronaut crews have experienced these levels of radiation before, but for durations shorter than a year, and a mission to Mars could possibly be 3 years in length. There is also evidence that people can comfortably handle higher levels of ionizing radiation where the radiation occurs naturally like Ramsar, Iran when people can experience 270 milli-Sieverts per year. A risk posture that the development, test, and flight of an NTR will meet opposition from groups who oppose nuclear energy must be likely and the impact can be sever to the effort. Active risk mitigation must be taken for an NTR full-scale development project. The NTR design must take into account safety for transport and off nominal conditions. Nuclear fuel element must consider containment of fission products and Low Enriched Uranium (LEU) that may meet less opposition should be considered for safety and security reasons. Even though testing was conducted on Rover/NERVA safely and successfully in the 60's with exhaust sent heavenward in to open air, modern testing of NTR must consider full containment and no release of ionizing radiation to the public and must meet the current requirement of no more than 0.1 milli-Sieverts per year to the public. 0.1 milli-Sieverts is equivalent to eating one banana or a 20 hour plane flight. Good communication with the public and regulatory agencies will be essential to show that all effort is applied toward protection to the public and astronauts. The inspiring endeavor to put humans on Mars to study the planet, search for life, and learn more about this Solar System will be full of risks but it will be worth it. NTR will be worth the development effort if it allows humans to explore our Solar System.

Kim, Tony↗

Mechanisms underlying cellular responses of cells from haemopoietic tissue to low dose/low LET radiation

To accurately define the risks associated with human exposure to relevant environmental doses of low LET ionizing radiation, it is necessary to completely understand the biological effects at very low doses (i.e., less than 0.1 Gy), including the lowest possible dose, that of a single electron track traversal. At such low doses, a range of studies have shown responses in biological systems which are not related to the direct interaction of radiation tracks with DNA. The role of these “non-targeted” responses in critical tissues is poorly understood and little is known regarding the underlying mechanisms. Although critical for dosimetry and risk assessment, the role of individual genetic susceptibility in radiation risk is not satisfactorily defined at present. The aim of the proposed grant is to critically evaluate radiation-induced genomic instability and bystander responses in key stem cell populations from haemopoietic tissue. Using stem cells from two mouse strains (CBA/H and C57BL/6J) known to differ in their susceptibility to radiation effects, we plan to carefully dissect the role of genetic predisposition on two non-targeted radiation responses in these models; the bystander effect and genomic instability, which we believe are closely related. We will specifically focus on the effects of low doses of low LET radiation, down to doses approaching a single electron traversal. Using conventional X-ray and γ-ray sources, novel dish separation and targeted irradiation approaches, we will be able to assess the role of genetic variation under various bystander conditions at doses down to a few electron tracks. Irradiations will be carried out using facilities in routine operation for bystander targeted studies. Mechanistic studies of instability and the bystander response in different cell lineages will focus initially on the role of cytokines which have been shown to be involved in bystander signaling and the initiation of instability. These studies also aim to uncover protein mediators of the bystander responses using advanced proteomic screening of factors released from irradiated, bystander and unstable cells. Integral to these studies will be an assessment of the role of genetic susceptibility in these responses, using CBA/H and C57BL/6J mice. The relevance of in vivo interactions between stem cells and the stem cell niche will be explored in the future by re-implantation techniques of previously irradiated cells. The above studies will provide fundamental mechanistic information relating genetic predisposition to important low dose phenomena, and will aid in the development of Department of Energy policy, as well as radiation risk policy for the public and the workplace. We believe the proposed studies accurately reflect the goals of the DOE low dose program.

99 GENERAL AND MISCELLANEOUS↗

Improving the prediction of DNI with physics-based representation of all-sky circumsolar radiation

Direct normal irradiance (DNI) is often interpreted differently in ground measurements and forecasts using numerical weather prediction (NWP) models, leading to substantial bias in DNI forecasting especially under cloudy-sky conditions. To mitigate the bias, we use the Fast All-sky Radiation Model for Solar applications with DNI (FARMS-DNI) to conduct physics-based simulations of solar radiation in the circumsolar region. The DNI is quantified using the sum of the radiation along the sun direction and the scattered radiation within the circumsolar region. FARMS-DNI is coupled with the Weather Research and Forecasting model with solar extensions (WRF-Solar) to predict day-ahead DNI in 9-km pixels over an extended domain covering the contiguous United States. The DNI forecasts for the entire year of 2018 are validated using surface-based observations at the Atmospheric Radiation Measurement (ARM) and Surface Radiation Budget Network (SURFRAD) sites and a satellite-based solar radiation product developed by the procedure of the National Solar Radiation Data Base (NSRDB). The results show that the WRF-Solar coupled with the conventional Beer-Bouguer-Lambert law underestimes the overall DNI forecasts by 30%-60%, which is a joint effect of the uncertainties in computing the circumsolar radiation and forecasting cloud properties. This bias is significantly reduced by using FARMS-DNI.

14 SOLAR ENERGY↗

SPIN EVOLUTION OF MILLISECOND MAGNETARS WITH HYPERACCRETING FALLBACK DISKS: IMPLICATIONS FOR EARLY AFTERGLOWS OF GAMMA-RAY BURSTS

The shallow decay phase or plateau phase of early afterglows of gamma-ray bursts (GRBs), discovered by Swift, is currently understood as being due to energy injection to a relativistic blast wave. One natural scenario for energy injection invokes a millisecond magnetar as the central engine of GRBs because the conventional model of a pulsar predicts a nearly constant magnetic-dipole-radiation luminosity within the spin-down timescale. However, we note that significant brightening occurs in some early afterglows, which apparently conflicts with the above scenario. Here we propose a new model to explain this significant brightening phenomena by considering a hyperaccreting fallback disk around a newborn millisecond magnetar. We show that for typical values of the model parameters, sufficient angular momentum of the accreted matter is transferred to the magnetar and spins it up. It is this spin-up that leads to a dramatic increase of the magnetic-dipole-radiation luminosity with time and thus significant brightening of an early afterglow. Based on this model, we carry out numerical calculations and fit well early afterglows of 12 GRBs assuming sufficiently strong fallback accretion. If the accretion is very weak, our model turns out to be the conventional energy-injection scenario of a pulsar. Therefore, our model can provide a unified explanation for the shallow decay phase, plateaus, and significant brightening of early afterglows.

79 ASTRONOMY AND ASTROPHYSICS↗

Interstellar dust charging in dense molecular clouds: Cosmic ray effects

The local cosmic-ray (CR) spectra are calculated for typical characteristic regions of a cold, dense molecular cloud to investigate two mechanisms of dust charging that have, thus far, been neglected: the collection of suprathermal CR electrons and protons by grains and photoelectric emission from grains due to the UV radiation generated by CRs. These two mechanisms add to the conventional charging by ambient plasma, produced in the cloud by CRs. We show that the CR-induced photoemission can dramatically modify the charge distribution function for submicron grains. We demonstrate the importance of the obtained results for dust coagulation: while the charging by ambient plasma alone leads to a strong Coulomb repulsion between grains and inhibits their further coagulation, the combination with the photoemission provides optimum conditions for the growth of large dust aggregates in a certain region of the cloud, corresponding to the densities n(H{sub 2}) between ∼10{sup 4} and ∼10{sup 6} cm{sup −3}. The charging effect of CRs is of a generic nature, and is therefore expected to operate not only in dense molecular clouds but also in the upper layers and the outer parts of protoplanetary disks.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of infrared illumination on the characteristics of CdZnTe detectors

Infrared (IR) radiation of proper wavelength deep penetrating inside the CdZnTe detector may interact with trapping centers and has a significant influence on the trapping-detrapping processes of charge carriers from traps, thereby influencing charge collection efficiency in the detector. We studied the effect of infrared (IR) illumination on the characteristics of planar and quasi-hemispherical CdZnTe detectors. These results show that the near bandgap IR illumination significantly affects the detectors characteristics. By selecting a wavelength and intensity of illumination, detectors spectrometric characteristics can be significantly improved. Improvement of spectrometric characteristics is due to better uniformity of charge collection on the detector volume, as evidenced by the improvement in the total absorption peak symmetry and shape of the output pulses. The degree of improvement is different for various detectors depending on the characteristics of source material used for detector fabrication and theirs dimensions. For example, a detector of sizes 10 x 10 x 5 mm{sup 3} with an initial energy resolution (FWHM) of 20.6 keV at 662 keV under IR illumination was improved up to 9.1 keV, but a detector of sizes 5 x 5 x 2.5 mm{sup 3} with an initial energy resolution (FWHM) of 7.1 keV can be improved up to 4.8 keV. The IR illumination with a properly chosen intensity improves spectrometric characteristic in a wide range of energies without any losses of registration effectiveness. IR Illumination was practically performed using conventional GaAlAs IR LEDs with different peak wavelengths of emitted radiation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗