Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Tax Credits for Clean Electricity: The Distributional Impacts of Supply-Push Policies in the Power Sector

We evaluate distributional and efficiency consequences of the bulk power clean electricity tax credits authorized by the 2022 Inflation Reduction Act. To do so, we link detailed electricity capacity expansion, computable general equilibrium, data-rich microsimulation, and air pollution models to estimate the policy incidence in terms of economic welfare and health impacts across a wide range of demographic groups. We evaluate the tradeoff between policy efficiency and income progressivity by comparing the tax credits to cap-and-trade policies that vary revenue recycling approaches. Under the scenarios analyzed the bulk power tax credits lead to increased clean electricity technology deployment resulting in a reallocation of capital from elsewhere in the economy, higher prices for capital and other goods, lower power prices, and lower emissions. The tax credits yield progressive outcomes for both economic welfare and health impacts. The health benefits exceed total policy costs and provide greater benefits for low-income and historically-marginalized households given the coincidence of household and emission source locations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data from: Land-based climate solutions for the United States

Meeting end-of-century global warming targets requires aggressive action on multiple fronts. Recent reports note the futility of addressing mitigation goals without fully engaging the agricultural sector, yet no available assessments combine both nature-based solutions (reforestation, grassland and wetland protection, and agricultural practice change) and cellulosic bioenergy for a single geographic region. Collectively, these solutions might offer a suite of climate, biodiversity, and other benefits greater than either alone. Nature-based solutions are largely constrained by the duration of carbon accrual in soils and forest biomass; each of these carbon pools will eventually saturate. Bioenergy solutions can last indefinitely but carry significant environmental risk if carelessly deployed. We detail a simplified scenario for the U.S. that illustrates the benefits of combining approaches. We assign a portion of non-forested former cropland to bioenergy sufficient to meet projected mid-century transportation needs, with the remainder assigned to nature-based solutions such as reforestation. Bottom-up mitigation potentials for the aggregate contributions of crop, grazing, forest, and bioenergy lands are assessed by including in a Monte Carlo model conservative ranges for cost-effective local mitigation capacities, together with ranges for (a) areal extents that avoid double counting and include realistic adoption rates and (b) the projected duration of different carbon sinks. The projected duration illustrates the net effect of eventually saturating soil carbon pools in the case of most strategies, and additionally saturating biomass carbon pools in the case of reforestation. Results show a conservative end-of-century mitigation capacity of 110 (57 – 178) Gt CO2e for the U.S., ~50% higher than existing estimates that prioritize nature-based or bioenergy solutions separately. Further research is needed to shrink uncertainties but there is sufficient confidence in the general magnitude and direction of a combined approach to plan for deployment now.

09 BIOMASS FUELS↗

POTENTIAL IMPACT OF INTERFACIAL BONDING EFFICIENCY ON USED NUCLEAR FUEL VIBRATION INTEGRITY DURING NORMAL TRANSPORTATION

Finite element analysis (FEA) was used to investigate the impacts of interfacial bonding efficiency at pellet pellet and pellet clad interfaces on surrogate of used nuclear fuel (UNF) vibration integrity. The FEA simulation results were also validated and benchmarked with reversible bending fatigue test results on surrogate rods consisting of stainless steel (SS) tubes with alumina-pellet inserts. Bending moments (M) are applied to the FEA models to evaluate the system responses of the surrogate rods. From the induced curvature, , the flexural rigidity EI can be estimated as EI=M/ . The impacts of interfacial bonding efficiency include the moment carrying capacity distribution between pellets and clad and cohesion influence on the flexural rigidity of the surrogate rod system. The result also indicates that the immediate consequences of interfacial de-bonding are a load carrying capacity shift from the fuel pellets to the clad and a reduction of the composite rod flexural rigidity. Therefore, the flexural rigidity of the surrogate rod and the bending moment bearing capacity between the clad and fuel pellets are strongly dependent on the efficiency of interfacial bonding at the pellet pellet and pellet clad interfaces. FEA models will be further used to study UNF vibration integrity.

finite element method↗

A Sensitivity Analysis of a Thin Film Conductivity Estimation Method

An analysis method was developed for determining the thermal conductivity of a thin film on a substrate of known thermal properties using the flash diffusivity method. In order to determine the thermal conductivity of the film using this method, the volumetric heat capacity of the film must be known, as determined in a separate experiment. Additionally, the thermal properties of the substrate must be known, including conductivity and volumetric heat capacity. The ideal conditions for the experiment are a low conductivity film adhered to a higher conductivity substrate. As the film becomes thinner with respect to the substrate or, as the conductivity of the film approaches that of the substrate, the estimation of thermal conductivity of the film becomes more difficult. The present research examines the effect of inaccuracies in the known parameters on the estimation of the parameter of interest, the thermal conductivity of the film. As such, perturbations are introduced into the other parameters in the experiment, which are assumed to be known, to find the effect on the estimated thermal conductivity of the film. A baseline case is established with the following parameters: Substrate thermal conductivity 1.0 W/m-K Substrate volumetric heat capacity 106 J/m3-K Substrate thickness 0.8 mm Film thickness 0.2 mm Film volumetric heat capacity 106 J/m3-K Film thermal conductivity 0.01 W/m-K Convection coefficient 20 W/m2-K Magnitude of heat absorbed during the flash 1000 J/m2 Each of these parameters, with the exception of film thermal conductivity, the parameter of interest, is varied from its baseline value, in succession, and placed into a synthetic experimental data file. Each of these data files is individually analyzed by the program to determine the effect on the estimated film conductivity, thus quantifying the vulnerability of the method to measurement errors.

36 MATERIALS SCIENCE↗

Availability Estimates of Low-Cost, Dispatch-Constrained Electricity (LDE)

This dataset accompanies the report "Potential Availability of and Supply Curves for Low-Cost, Dispatch-Constrained Electricity", which provides initial estimates of the quantity and availability of the potential low-cost, dispatch-constrained electricity (LDE) resource in the United States under scenarios with high variable renewable energy (VRE) penetrations. The analysis also estimates supply curves that can be used in subsequent analysis of the opportunity to use the LDE. The estimated LDE resource could be used for various applications that value low-cost electricity and can operate at reduced capacity factors, including electrolytic hydrogen production and carbon capture. The analysis accompanying this dataset was performed in 2018-2019 to support an analysis of "The Technical and Economic Potential of the H2@Scale Concept within the United States" ( https://www.nlr.gov/docs/fy21osti/77610.pdf ). This dataset includes the quantity of estimated LDE resource for each hour of the year in 2050, aggregated to both the national level and the ReEDS balancing area level. As described in the accompanying report, the ReEDS model was used to project the evolution of the power sector over time. Links to the mapping of ReEDS balancing areas to states and ReEDS balancing area shape files are provided. This dataset also includes the report figure data.

08 HYDROGEN↗

Survey and Assessment of the Ocean Renewable Energy Resources in the US Gulf of Mexico

This study was conducted by the National Renewable Energy Laboratory (NREL) and funded by the Bureau of Ocean Energy Management (BOEM). It provides a comprehensive feasibility assessment of multiple offshore renewable energy technologies in the Gulf of Mexico (GoM) to inform BOEM's strategic plans related to possible Outer Continental Shelf alternative energy leasing activities in the GoM. In coordination with Gulf Coast states, the study includes some information on offshore renewable energy potential in state waters for future energy planning. The goal of the study is to survey potential offshore renewable energy sources in the GoM and quantify their feasibility relating to resource adequacy, technology maturity, and the potential for competitive cost. The study provides a review of available technologies and concepts for generating offshore renewable energy, including a high-level assessment of the current state of each technology and its potential for future advances. It provides a breakdown of resource capacity for each renewable energy technology and a recommendation that offshore wind be pursued for future study as the most promising technology. The renewable technologies that were considered include offshore wind, wave energy, tidal energy, ocean current energy, offshore solar energy, ocean thermal energy conversion (OTEC), cold water source cooling, and hydrogen (as a storage medium to utilize existing pipeline infrastructure). The resource capacity for each of these renewable energy sources was quantified for both the gross resource capacity potential (gross resource) and the technical resource capacity potential (technical resource) using the methodology described in an earlier NREL report. Many of these sources are very immature from a commercial perspective, which makes some of the comparisons difficult. In many cases, new methods were developed to estimate nominal power density for each technology type, which were necessary to convert the resource areas into deployable gross and technical resource capacity potentials.

17 WIND ENERGY↗

Jobs and Economic Development from New Transmission and Generation in Wyoming (Fact Sheet)

Wyoming is a significant energy exporter, producing nearly 40% of the nation's coal and 10% of the nation's natural gas. However, opportunities to add new energy exports in the form of power generation are limited by insufficient transmission capacity. This fact sheet summarizes results from a recent analysis conducted by NREL for the Wyoming Infrastructure Authority (WIA) that estimates jobs andeconomic development activity that could occur in Wyoming should the market support new investments in power generation and transmission in the state.

17 WIND ENERGY↗

Low global warming potential (GWP) refrigerant supermarket refrigeration system modeling and its application

As an environmentally friendly low global warming potential (GWP) refrigerant, Carbon dioxide (CO 2 ) has continuously gained popularity and research attention as alternative refrigerant for supermarket refrigeration system. In this paper, to fulfill the increasing need of accurate Low-GWP supermarket refrigeration models for development of supervisory level control and optimization strategies, a high fidelity model is developed for CO 2 transcritical supermarket refrigeration system which includes compressor rack of low temperature (LT) compressors and medium temperature (MT) compressors, air-cooled gas cooler, evaporator, expansion valves and other auxiliary equipment. A resistance-capacity model structure is proposed to simulate the display cases. Semi-thermodynamic models are proposed to estimate reciprocating compressors volumetric efficiency and power consumption. Furthermore the zone modeling approach is used for evaporator simulation, and air-cooled gas cooler is modeled with distributed modeling method. The expansion valve simulation is based on orifice flow model. To calibrate these models, both manufacture performance data and experimental data are used. The experiments are conducted with a full instrumental CO 2 supermarket refrigeration system installed in Oak Ridge National Lab Flexible Research Platform (FRP). The simulation model can predict the system performance, including power consumption, cooling capacity, mass flow rate, temperature, and pressure, with high accuracy (within ±4%) compared to experimental data. In addition, this developed model has been used to create the system optimum high side pressure for high side expansion valve control, and to generate wide operating range simulation data for developing the batter-equivalent commercial refrigeration system model which can be used in grid interactive control development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geothermal Deep Direct Use for Turbine Inlet Cooling in East Texas

The National Renewable Energy Laboratory (NREL), the Southern Methodist University Geothermal Laboratory (SMU), Eastman Chemical (Longview, TX), and TAS (Houston, TX) evaluated the feasibility of using geothermal heat to improve the performance of a natural-gas power plant in East Texas. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of a geologic region known as the Sabine Uplift. The feasibility study focused on determining the potential for accessing a subsurface hot-water geothermal resource within a 10-km radius of the site to provide thermal energy for absorption chillers. Wells within a 20-km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, field porosity and permeability. The lithologies of most interest are the Lower Cretaceous Trinity Group and Upper Jurassic Cotton Valley Group. The deeper Cotton Valley formations are hotter (averaging 117 to 130°C), yet permeability and porosity are low. The shallower Trinity Group contains more variability in permeability and porosity and lower temperatures averaging about 98 to 117°C. The shallower formations are considered despite the lower temperature because of increased ability to produce larger volumes of water and extract enough heat before reinjection. The complete SMU analysis is available in the National Geothermal Data System (NGDS). Tapping such deep geothermal sources for direct heating (as opposed to power generation) is known as geothermal deep direct use (DDU). Geothermal DDU has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for what are typically small-scale, variable-demand projects. This project examines the feasibility of geothermal energy integration in a natural-gas combined cycle power station in East Texas. The DDU resource is tapped to drive absorption chillers (24/7) for production of chilled water at 5-10°C (41-50°F). This chilled water is stored until needed, which allows for continuous operation with a relatively small-capacity geothermal/absorption chiller system. When conditions are favorable, the chilled water is dispatched to cool the air entering the compressor stage of a gas combustion turbine. This process, known as turbine inlet cooling (TIC), boosts power production during periods of high temperature and high-power demand. Such systems can enhance grid reliability and reduce the cost for peak-demand power. A simulation model of the power plant was developed in IPSEpro software and validated against operational data from the plant. This model allowed the team to estimate the additional power that could be produced by applying TIC under different operating and ambient conditions. Absorption chiller performance was estimated from vendor sources to determine the production rate of chilled water from the geothermal resource. Geothermal drilling and development costs were estimated using NREL's GEOPHIRES 2.0. The expected lower drilling costs in this region led to an estimated cost of geothermal heat of about $4/MMBtu (1.4 cents/kWh t ). The estimated cost for the absorption chillers and TIC hardware were obtained from literature sources and project partners. Hourly data were obtained for weather, natural gas and electricity prices, and plant operating state for 2017, which served as a representative year. NREL estimated the capital cost, operating cost, and additional electricity production and revenue for different combinations of geothermal capacity, chiller capacity, and water storage-tank size. The analysis drove toward smaller geothermal and chiller systems to reduce equipment cost. A relatively low-cost water storage tank accumulated the near-continuous chilled water output for later use when TIC was most valued.

15 GEOTHERMAL ENERGY↗

A Demand-driven, Capacity-constrained, Adaptive Algorithm for Computing Steady-state and Transient Flows in a Petroleum Transportation Network

We developed an algorithm to perform simulations of a supply network for crude oil and refined products in order to estimate the consequences of disruptions to components of the network. Components include oil fields, import terminals, refineries, transmission pipelines, tank farms, and distribution terminals. The physical system is represented as network connections, capacities, and inventories. The governing equations describe mass balance in a non-linear diffusive system in which flows in the network are along gradients in a potential field. Each node in the network has a defined storage capacity and desired storage amount. The potential at each node is a function of the difference between the actual and desired amount of fluid stored. The potential can be thought of as the balance between the desire to increase inflows to maintain the desired storage level and the willingness to provide fluid for consumption or outflow to downstream nodes.

02 PETROLEUM↗

ELM 1016706669-AA B581 GDE01 Generator Summary pg 4-5 only

The table below shows the general load breakdown for 581GDE01. Although the total connected load exceeds the generator’s 150kW nameplate capacity, the normal configured load during standby power mode is less, which was measured at 81kW, or 54%, during preventive maintenance activities on 12/12/24. The generator’s available spare capacity must account for dynamically changing loads that can increase the total power demand at any time. If the two online VFD’s are operated at full speed the actual standby mode load is estimated to increase by 38kW, which would bring the total configured load during standby power mode to 119kW, or 79%, still within 581GDE01’s acceptable capacity. Per the LLNL Site 200 Generator Consolidation Final Study 2022, “Standby Emergency Generator nameplate ratings are based upon operation with varying load averaging 70% of the nameplate for 200 hours per year. Continuous loading between 70% and 100% will reduce a generator’s expected lifetime before a major overhaul. This is never a problem with Laboratory machines because of conservative application of generators and the reliability of the normal power system combines to keeps the load and hours down”. To achieve optimal performance and prolong generator life, the recommended generator loading is between 40% and 70%, optimally at 70%, which 581GDE01 appropriately falls within.

42 ENGINEERING↗

Evaluation of Nominal Energy Storage at Existing Hydropower Reservoirs in the US

Long-term planning and operation of hydropower reservoirs require an understanding of both water and energy storage. As energy storage needs of the evolving grid increase, we must account for the water and energy storage potential of these reservoirs. Given the limitations of current data on existing hydropower, we compile statistics related to storage volume and hydraulic head from publicly available data sets and examine differences in descriptions of US hydropower storage. Assembled characteristics are used to calculate nominal energy storage capacity, a simple measure of potential to generate power from a given volume of water, not factoring in detailed constraints. Inventory-based estimates of energy storage are calculated at 2,075 dams, which helps put the potential for US hydropower to support energy storage in context with similar evaluations in other regions and with other energy storage technologies. The national energy storage capacity ranges between 34.5 and 45.1 TWh depending on the information used, with 52% of energy storage located at the 10 largest reservoirs in the US. Energy storage capacities are also calculated at 236 dams with historical volume and elevation data. Finally, reservoir inflows provide context for the storage volumes and sensitivities to hydrologic variability. Larger reservoirs with greater storage volume to inflow ratios are concentrated in the Western US, but the majority of hydropower reservoirs store less than the annual inflow. We address several infrastructure and water resource informatics challenges and highlight remaining issues, including representing seasonal or shorter variability in water volumes and representing connected hydropower facilities.

13 HYDRO ENERGY↗

RectifHydPlus: Forty Year Hydropower Generation Reanalysis for Conterminous United States, Version 1.1.

This dataset contains monthly hydropower net-generation totals for 590 plants (each >10 MW) across the conterminous United States (CONUS) from 1980 to 2019. RectifHydPlus v1.1 includes one harmonized table of historical monthly generation—backfilled with observed monthly values where available—and two companion tables: (i) an estimates-only version with no backfill and (ii) a hydrological-control version that removes the effects of capacity and operational change. Each table comprises 23,600 records (590 plants × 40 years). The dataset was developed to address temporal gaps and inconsistencies in publicly available hydropower generation data as available through EIA-923 survey reports. Each record includes a quality label denoting the underlying proxy—from best (direct reservoir releases) to weakest (pattern copied from similar years). By combining the agency-reported survey records with observed and simulated hydrologic releases, RectifHydPlus offers complete, quality-labeled monthly estimates suitable for trend analysis and generation of hydropower generation inputs for energy-water modeling.

Turner, Sean [Oak Ridge National Laboratory (ORNL)↗

Analysis of Plug Load Capacities and Power Requirements in Commercial Buildings: Preprint

Plug and process load power requirements are frequently overestimated because designers often use estimates based on 'nameplate' data, or design assumptions are high because information is not available. This generally results in oversized heating, ventilation, and air-conditioning systems; increased initial construction costs; and increased energy use caused by inefficiencies at low, part-load operation. Rightsizing of chillers in two buildings reduced whole-building energy use by 3%-4%. If an integrated design approach could enable 3% whole-building energy savings in all U.S. office buildings stock, it could save 34 TBtu of site energy per year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economics for Conversion of Lignocellulosic Biomass to Ethanol by Indirect Gasification and Mixed Alcohol Synthesis

This techno-economic study investigates the production of ethanol and a higher alcohols coproduct by conversion of lignocelluosic biomass to syngas via indirect gasification followed by gas-to-liquids synthesis over a precommercial heterogeneous catalyst. The design specifies a processing capacity of 2,205 dry U.S. tons (2,000 dry metric tonnes) of woody biomass per day and incorporates 2012 research targets from NREL and other sources for technologies that will facilitate the future commercial production of cost-competitive ethanol. Major processes include indirect steam gasification, syngas cleanup, and catalytic synthesis of mixed alcohols, and ancillary processes include feed handling and drying, alcohol separation, steam and power generation, cooling water, and other operations support utilities. The design and analysis is based on research at NREL, other national laboratories, and The Dow Chemical Company, and it incorporates commercial technologies, process modeling using Aspen Plus software, equipment cost estimation, and discounted cash flow analysis. The design considers the economics of ethanol production assuming successful achievement of internal research targets and nth-plant costs and financing. The design yields 83.8 gallons of ethanol and 10.1 gallons of higher-molecular-weight alcohols per U.S. ton of biomass feedstock. A rigorous sensitivity analysis captures uncertainties in costs and plant performance.

09 BIOMASS FUELS↗

Optimum Full Information, Unlimited Complexity, Invariant and Minimax Clock Skew and Offset Estimators for IEEE 1588

This paper presents the problem of clock skew and offset estimation for the IEEE 1588 precision time protocol. Built on the classical two-way message exchange scheme, IEEE 1588 is a prominent synchronization protocol for packet switched networks. Because of the presence of random queuing delays in a packet switched network, the joint recovery of clock skew and offset from the received packet timestamps can be viewed as a statistical estimation problem. Recently, assuming perfect clock skew information, minimax optimum clock offset estimators were developed for IEEE 1588. Building on this work, we first develop joint optimum invariant clock skew and offset estimators for IEEE 1588 for known queuing delay statistics and unlimited computational complexity. We then show the developed estimators are minimax optimum, i.e., these estimators minimize the maximum skew normalized mean square estimation error over all possible values of the unknown parameters. Minimax optimum estimators that utilize information from past timestamps to improve accuracy are also introduced. The developed optimum estimators provide useful fundamental limits for evaluating the performance of clock skew and offset estimation schemes. These performance limits can aid system designers to develop algorithms with the desired computational complexity that achieve performance close to the performance of the optimum estimators. If a designer finds an approach with a complexity they find acceptable and which provides performance close to the optimum performance, they can use it and know they have near optimum performance. This is precisely the approach used in communications when comparing to capacity.

Cellular networks↗

Thermophysical properties of the Ghareb formation relevant for nuclear waste disposal

The Ghareb formation, a shallowly buried porous chalk in Israel, is currently a candidate for nuclear waste disposal. The potential repository is somewhat unique for its host rock and emplacement in shallow (500 m) engineered large diameter boreholes. Herein, the thermal properties of the Ghareb are determined to support design and performance assessment; the relevant properties measured are thermal conductivity, specific heat capacity, thermal diffusivity, and thermal expansion coefficient along with their relationship with varying temperature. For the temperature range of 40 to 275 °C, the thermal conductivity ranges from 0.30 to 1.10 W/m·K, the thermal diffusivity ranges from 0.20 to 0.72 mm 2 /s, and volumetric heat capacity ranges from 0.86 to 2.00 MJ/m 3 ·K. Thermal strain measurements were used to estimate the linear thermal expansion coefficient to be 6·10 –4 –9·10 –2 °C -1 from 40 to 300 °C. These measured properties were used in a thermomechanical model to estimate near-field stresses an hour and 10 years after waste emplacement; the borehole was found to be stable. Thermal loading after 10 years was predicted to elevate local pore pressures by 1–1.5 MPa. The laboratory measurements coupled with analyses are the first attempts at performance assessment characterization for this first of its kind potential repository setting with this chosen host rock.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗