Search NASA⌕ Search

SEARCH · Search NASA

Results for “Combination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

A Combined Day-ahead and Real-time approach for Scheduling Real and Reactive power dispatch of Battery Energy Storage System

A combined day-ahead (look-ahead) and real-time optimization approach is proposed to schedule BESS real and reactive power dispatch. The look ahead scheduling agent maximizes profit and essentially performs the function of energy arbitrage by looking at forecasted prices, network constraints and BESS operating conditions to generate real power dispatch schedule. While this schedule is followed, the real time optimization agent computes an optimum reactive power set-point (for a particular objective function) using optimal power flow framework. The concepts are implemented by co-simulating legacy tools and demonstrated on a large real world distribution system. In addition to the profits from energy arbitrage, optimum reactive power set point computation results in achieving desirable network attributes like flat voltage profiles and minimizing voltage deviations from desired value.

Bhatti, Bilal A.↗

Combined Structural Analysis of Core and Image Log of TGH 76-31 South East of Mt Baker, Washington State

Despite active volcanism, few geothermal energy resources have been developed in the Cascades Range. Temperature Gradient Hole 76-31 was drilled to ~440 m measured depth to probe for zones where fractures provide fluid conduits that transport deep volcanic heat to shallow depths that could support baseload, carbon neutral electrical generation. These zones were predicted by a Play Fairway assessment (PFA) of resource potential along a zone 11 km west-southwest of the summit of Mount Baker Volcano. Rock core, temperature logs, and an acoustic image log were obtained. By comparison to outcrops, the core has been initially interpreted as the Chilliwack group comprised of partially metamorphosed basaltic to andesitic volcanics. Core mapping reveals complex, steeply dipping networks of fractures and brecciation along slickensided strike slip faults; clay alteration is common in many of these structures. The majority of fractures are thoroughly healed by layers of chlorite and calcite; preservation of pyrite indicates anoxic conditions. The majority of fracture porosity resides in very dense fractures a few centimeters or less in length. The image log provides good insights into attitude of fractures that fully transect the core, but generally underestimates fracture density. The combination of complex, non-planar fracture zones containing many short fractures and healing promote misinterpretation of natural fracture attitude and density in the image log. The healing and anoxic minerals are consistent with the conductive temperature gradient measured in the well below a shallow isothermal zone, although, several fractures are open or only partially healed and resulted in fluid entries into the well. Here, the equilibrated measured temperature gradient of 64ºC/km and calculated heat flow of 145 mW/m2 is more than twice the regional average, indicating local influence of the Mt Baker magmatic system at the Little Park Creek TGH site.

Cascades↗

Systems and methods that use harmonic drives for converting reciprocating axial motion to continuous rotary motion, helical drives for converting reciprocating rotary motion to reciprocating axial motion and combinations thereof for converting reciprocating rotary motion to continuous rotary motion

A harmonic drive assembly and fluid-powered linear motors with both axial pistons are rotary piston arrangements incorporating the harmonic drive assembly are disclosed. The motors may be used in downhole drilling applications, but the drive assembly and/or motors may be used in other applications. The assembly, motors and methods use advanced harmonic drives, advanced helical drives, and combinations thereof with 1) motors with axial pistons and reciprocating linear rings to convert reciprocative axial motion to continuous rotary motion, and 2) motors with rotary pistons and reciprocating linear rings to rectify reciprocative rotary motion to continual rotary motion to improve performance over prior configurations.

Raymond, David W.↗

Characterization of CO2 Binding on Alkaline Metal Oxide Sorbents and DFMs for Combined Capture and Conversion

As the world endures environmental crises associated with climate change and the rise of atmospheric CO2 concentrations from anthropogenic CO2 emission, carbon capture and utilization (CCU) technologies are increasingly necessary. Reactive carbon capture (RCC) technologies, in which capture and conversion of CO2 occur in a single reactor, are more energetically and economically attractive by avoiding the need to purify, compress, and transport the captured CO2. To this end, the development of dual function materials (DFM) that enable CO2 capture and conversion to useful C1 products, namely (1) methane, (2) CO, and (3) methanol, are attractive near-term targets for commercial CCU processes for renewable fuels and chemicals. DFM are composed of sorbents and catalysts co-dispersed on the same high surface area carrier. The sorbent component allows for selective capture of CO2 from a gas stream and the catalyst component subsequently performs the in-situ conversion of the adsorbed CO2 upon introduction of a reactive gas (typically H2). The survey of DFM formulations reveals a variety of sorbent+catalyst combinations of interest. There is, however, a lack of depth in fundamental understanding of how the CO2 binds to these materials and how the subsequent reaction mechanisms are affected, which are critical features for the development of next-generation materials with improved performance. To this end, we will describe in this work the CO2 binding characteristics of established and/or new DFM and their sorbent-only counterparts. The surface CO2 binding mechanism and capture capacity will be probed using techniques such as in-situ DRIFTS, operando TGA, and CO2 chemisorption.

alkaline oxides↗

High CO2 Capture Rate Cost and Performance for F- and H-Class Natural Gas Combined Cycles (NGCC)

The National Energy Technology Laboratory (NETL) is updating its study titled “Cost and Performance Baselines for Fossil Energy Plants, Volume 1: Bituminous Coal and Natural Gas to Electricity.” Revision 4 was published in 2019. Pulverized coal (PC) and natural gas combined cycle (NGCC) cases with carbon capture in that study capture carbon dioxide (CO2) at 90% efficiency. Field-testing of post-combustion CO2 capture technology as well as vendor and industry feedback on projects currently in the planning stages (including FEED projects sponsored by DOE) indicate that capture rates as high as 95% are feasible for both coal- and natural gas-fueled electricity generating units. Technology suppliers (as reflected in vendor-supplied information provided to DOE for this study that included cost and performance estimates for both NGCC (97%) and PC (99%) study cases) as well as subject matter experts acknowledge and support that solvent-based post-combustion CO2 capture technologies are capable of achieving CO2 removal rates beyond 95% on low-purity streams representative of fossil-fueled combustion; however, the relatively limited experience with design and operation of capture systems that can routinely, reliably, and economically achieve very high removal rates (e.g., 97% for NGCC flue gas) requires further study. This presentation will address performance and cost estimates for 90%, 95%, and 97% capture for F- and H-class NGCC plants. This presentation was given at the 2022 Pittsburgh Coal Conference.

Fout, Timothy↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

Evaluation of Bifacial Modules and PV Technologies with Combined-Accelerated Stress Testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. This is attributed to previous x-ray topography work showing higher stress in cells in glass-glass modules than glass backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. Finally, among multiple cell degradation modes that we observed such as light-induced degradation (LID), we differentiated susceptibility to potential-induced degradation (PID) on the back of the bifacial Passivated Emitter Back Cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass/glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while -1200 V system voltage is applied in C-AST, supporting the conclusion that this module type would be susceptible to PID in the field.

bifacial modules↗

High Fluence Active Irradiation and Combined Effects Testing of Sapphire Optical Fiber Distributed Temperature Sensors

Investigate the in-pile performance of sapphire optical fiber temperature sensors and to develop clad sapphire optical fibers for in-pile instrumentation. Evaluate the distributed sensing performance of the sensors through optical backscatter reflectometry under combined radiation and temperature effects, and high fluence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Urban Combined Heat and Power with Integrated Renewables and Energy Storage

District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure. Frequently, district energy systems are centered around combined heat and power (CHP) plants that generate electricity as well as heating and cooling to the local buildings. By providing both electricity and thermal energy from a single fuel source and central location, these systems use less fuel, decrease energy and operational costs, and reduce the need for heating and cooling equipment in individual buildings.

EMS, CHP, GWU↗

Flexible Natural Gas/Hydrogen Combined Heat and Power System

District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure. Frequently, district energy systems are centered around combined heat and power (CHP) plants that generate electricity as well as heating and cooling to the local buildings. By providing both electricity and thermal energy from a single fuel source and central location, these systems use less fuel, decrease energy and operational costs, and reduce the need for heating and cooling equipment in individual buildings.

CHP, ID/3D↗

Combined hydrothermal liquefaction and catalytic hydrothermal gasification system and process for conversion of biomass feedstocks

A combined hydrothermal liquefaction (HTL) and catalytic hydrothermal gasification (CHG) system and process are described that convert various biomass-containing sources into separable bio-oils and aqueous effluents that contain residual organics. Bio-oils may be converted to useful bio-based fuels and other chemical feedstocks. Residual organics in HTL aqueous effluents may be gasified and converted into medium-BTU product gases and directly used for process heating or to provide energy.

09 BIOMASS FUELS↗

Combined Algal Processing for the Synthesis of Liquid Oleofuels and Products (CAPSLOC) - WBS 1.3.4.204

Combined Algal Processing for the Synthesis of Liquid Oleofuels and Products (CAPSLOC) aims to develop a biorefinery concept that is composition-agnostic and enables economically, environmentally, and socially viable biofuel production by maximizing the value from each fraction. To achieve this, we have employed an iterative approach between R&D and TEA/LCA to establish process targets and quantify improvements in the minimum fuel selling price (MFSP), reduce carbon intensity, and support the state of technology (SOT). We have surveyed various methods for biomass pretreatment and successfully demonstrated pre-pilot scale pretreatment in batch mode. Using techniques such as lipid modification, fermentation, mild oxidative treatment (MOT), and carbonization, we have developed biofuel precursors and a range of value-added co-products. Our project has demonstrated significant improvements in key aspects of algae processing, particularly in pretreatment technologies suitable for variable composition, co-products available from lipid and extracted solid streams, conditioning and fermenting high-protein hydrolysates, and recovering nitrogen (N) and phosphorus (P) nutrients for recycling to cultivation ponds. The success of this project will support the commercialization of a sustainable microalgal biorefinery industry.

biofuel↗

Combined TREAT-LOC & SATS Integral LOCA Experiment Plan

The Transient Reactor Test Facility (TREAT) loss-of-coolant (LOC) and highburnup (HBu) experiment series, along with the Severe Accident Test Station (SATS) HBu experiment series, are integral LOC accident (LOCA) experiments planned under the Department of Energy (DOE) Advanced Fuels Campaign (AFC) program, which aims to support burnup extension needs by addressing identified R&D priorities in order to achieve an improved understanding of fuel fragmentation, relocation, and dispersal (FFRD) of HBu fuel during LOCA events. Priorities have been identified by the Electric Power Research Institute (EPRI)’s Collaborative Research on Advanced Fuel Technologies (CRAFT) Fuel Performance and Testing Technical Experts Group (FPTTEG). The data produced under this plan will be used to further validate and confirm existing models and inform future R&D and model development. The experimental program was specifically developed to address data gaps and opportunities identified via detailed review of the existing public knowledge base on LOCA FFRD, as well as reviewing specific experimental development activities regarding prototypic LOCA conditions for light-water reactor (LWR) systems. The test program relies on a unique combination of in- and out-of-pile experimental approaches to provide a clear tieback to the existing integral and semi-integral LOCA experiment database, using state-of-the-art facilities. More importantly, the program will systematically investigate the impacts of prototypic HBu fuel/cladding thermomechanical behaviors under postulated LWR LOCA conditions not yet fully investigated. These conditions correspond with prototypic decay-energy heatup (DEH) and stored-energy heatup (SEH) conditions. First, TREAT’s unique capability will enable the first evaluation of the impact of SEH conditions on HBu fuels. The test program will emphasize the development of an improved mechanistic understanding of key phenomena through independent experimental systems, development of a database to support fuel performance modeling tools, world-leading advanced materials characterization, and the most advanced approach to in situ diagnostics ever deployed to evaluate FFRD. The results will represent a significant leap forward in evaluating prototypic conditions and novel data to support modeling development and validation, as well as to inform the technical basis for LOCA-induced FFRD.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Combining complex flow manifold with three dimensional woven lattices as a thermal management unit

The present invention is directed to a manifold for directing cooling fluid and/or gas to a heat exchanger in a flow configuration designed to optimize heat transfer from the heat exchanger. The manifold can take many different forms such as a layered construction with distributed inlet paths, local outlet paths, a central collection changer and a path for fluid removal. The manifold can be formed from a metal, plastic, rubber, ceramic, or other heat resistant material known to or conceivable by one of skill in the art. The manifold can also be combined with any type of heat exchanger known to or conceivable by one of skill in the art to form a thermal management unit. To optimize overall properties such as low pressure drop, high heat transfer, and excellent temperature uniformity of the thermal management unit, the manifold can be graded, expanded and scaled as needed.

Hemker, Kevin J.↗

Combined thermal energy storage and heat exchanger unit

The invention provides a method for storing heat and continuously generating electricity, the method comprising a phase change material; first fluid conduit in thermal communication with the phase change material wherein the first conduit is adapted to receive a first fluid; a second fluid conduit in thermal communication with the phase change material, wherein the second conduit is adapted to receive a second fluid; and a turbine in thermal communication with the second fluid. Also provided is a method for continuously charging the energy power block portion of a combined thermal energy storage and heat exchanger unit with heated fluid generated by concentrated solar power, the method comprising intermittently storing heat in a phase change material; and continually directing the heat from the phase change material to a turbine such that the phase change material buffers the turbine against inconsistent solar heat inputs.

France, David M.↗

Advanced Airfoils for Efficient Combined Heat and Power

This poster summarizes a recent effort to use advanced materials, additive manufacturing, and advanced cooling designs to increase the gas turbine inlet temperature for small (<10MW) gas turbines typically used in combined heat and power applications.

Straub, Douglas↗