Search NASA⌕ Search

SEARCH · Search NASA

Results for “Complex Loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Complexity of segregation behavior at localized deformation sites formed while in service in a 316 stainless steel baffle-former bolt

Here, post-irradiation evaluation was performed on a 316 stainless steel baffle former bolt harvested after 40 years of service in a pressurized water reactor. Microstructure analysis revealed the presence of defect-free dislocation channels and strain-induced twins, indicative of loading at a stress level close to yield stress at least once while in service. Primary radiation-induced Ni/Si precipitates were destroyed during channel and twin formation, and secondary, significantly coarser Ni/Si precipitates formed along newly formed Σ3 boundaries during the continued irradiation. Additionally, an elevated phosphorus level was observed inside the strain-induced twin. Complex chemistry inside the strain-induced feature may overlap with dislocation pileups and impact localized corrosion, material long-term performance, and safety.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Identifying the Root Causes of Wait States in Large-Scale Parallel Applications

Driven by growing application requirements and accelerated by current trends in microprocessor design, the number of processor cores on modern supercomputers is increasing from generation to generation. However, load or communication imbalance prevents many codes from taking advantage of the available parallelism, as delays of single processes may spread wait states across the entire machine. Moreover, when employing complex point-to-point communication patterns, wait states may propagate along far-reaching cause-effect chains that are hard to track manually and that complicate an assessment of the actual costs of an imbalance. Building on earlier work by Meira Jr. et al., we present a scalable approach that identifies program wait states and attributes their costs in terms of resource waste to their original cause. Ultimately, by replaying event traces in parallel both forward and backward, we can identify the processes and call paths responsible for the most severe imbalances even for runs with hundreds of thousands of processes.

97 MATHEMATICS AND COMPUTING↗

Predicting Wind Loading and Instability in Solar Tracking PV Arrays

Wind loading and the fluctuating pressure loads it creates on PV panel surfaces are associated with multiple degradation mechanisms and failures. Modest wind speeds create reversing loads that can initiate cell cracks and weather cracked cells. Stronger wind speeds and extreme weather events can lead to larger scale forces and the aerodynamic instability known as torsional galloping. All these effects are dependent on the complex coupling between wind speed, panel orientation, and a myriad of other hardware and site-specific factors. In this work, we present the latest developments from our work to build an open-source, high-performance computing (HPC) fluid dynamics solver to predict and mitigate these effects. This simulation package allows users to easily specify different array layouts, solar-tracking angles, panel geometries, and weather conditions before automatically generating a refined computational mesh and solving for the unsteady loading on each panel surface. Small domains (e.g., a single panel row in isolation) can be solved on a modern laptop, while larger domains or very high-fidelity studies can be solved on distributed or HPC resources with minimal modifications to the underlying problem specification. We present preliminary case studies obtained using this simulation package and highlight how increased wind speeds combined with sub-optimal tracking angles can exacerbate degradation drivers.

aerodynamics↗

Propidium Monoazide (PMAxx)-Recombinase Polymerase Amplification Exo (RPA Exo) Assay for Rapid Detection of Burkholderia cepacia Complex in Chlorhexidine Gluconate (CHX) and Benzalkonium Chloride (BZK) Solutions

Both sterile and non-sterile pharmaceutical products, which include antiseptics, have been recalled due to Burkholderia cepacia complex (BCC) contamination. Therefore, minimizing the frequency of outbreaks may be conducive to the development of a quick and sensitive approach that can distinguish between live and dead loads of BCC. We have assessed an exo probe-based recombinase polymerase amplification (RPA) with 10 µM propidium monoazide (PMAxx) for selective detection of live/dead BCC cells in various concentrations of antiseptics (i.e., chlorhexidine gluconate (CHX) and benzalkonium chloride (BZK) solutions) after 24 h. The optimized assay conducted using a set of primer–probes targeting gbpT was performed at 40 °C for 20 min and shows a detection limit of 10 pg/µL of genomic DNA from B. cenocepacia J2315, equivalent to 10 4 colony-forming units (CFU/mL). The specificity of a newly designed primer and probe was 80% (20 negatives out of 25). The readings for total cells (i.e., without PMAxx) from 200 µg/mL CHX using PMAxx-RPA exo assay was 310 relative fluorescence units (RFU), compared to 129 RFU with PMAxx (i.e., live cells). Furthermore, in 50–500 µg/mL BZK-treated cells, a difference in the detection rate was observed between the PMAxx-RPA exo assay in live cells (130.4–459.3 RFU) and total cells (207.82–684.5 RFU). This study shows that the PMAxx-RPA exo assay appears to be a valid tool for the simple, rapid and presumptive detection of live BCC cells in antiseptics, thereby ensuring the quality and safety of pharmaceutical products.

59 BASIC BIOLOGICAL SCIENCES↗

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-economic assessment and life cycle assessment of three potential pathways for biomass liquefaction

Biomass liquefaction can enhance corn-stover slurry transportation by reducing yield stress and overall viscosity, easing biomass handling, especially for slurries at high solids loading (≥30 % (w/v). Implementing a liquefaction process at the front-end of the biorefinery could reduce downtime caused by equipment fouling. Furthermore, liquefaction reduces process complexity by transforming high fiber mass into a pumpable slurry. Three scenarios for liquefaction of corn stover pellets: enzyme process, enzyme mimetic process, and a combined process of enzyme and enzyme mimetic were assessed. The ideal process will have the best performance-to-cost ratio, with minimal impact on the environment. Techno-economic and life-cycle analyses were used to understand the economic and environmental effects of the three liquefaction scenarios and to determine if one or more can achieve cost parity. Here, results show that the enzyme process had the best performance in terms of cost and emissions (gCO 2 -equivalent/kg slurry)compared to the other scenarios.

09 BIOMASS FUELS↗

Mesoscale Modeling Approach for Quantifying Microstructure-Aware Micromechanical Responses in Metal Hydrides

Metal hydrides can undergo significant volume changes upon hydrogen uptake and release, which induce a mechanical response that depends not only on the evolving hydrogen composition but also on the microstructure. We present a comprehensive mesoscale modeling framework based on microelasticity theory to quantify the micromechanical responses of metal hydrides, specifically focusing on a hydrogenating polycrystalline MgH 2x particle within a host material as a model micromechanical system. Utilizing digitally generated realistic microstructures and density-functional-theory-derived parameters, we analyzed highly nonuniform local stress profiles in the polycrystalline hydrides under the clamping force exerted by the host during hydrogenation. Our framework also allows us to predict the corresponding strain energy accumulation and mechanical hot spots formation in the hydrides, highlighting their roles in thermodynamic destabilization and mechanical failure, respectively. Through extensive parametric simulations, we further quantified the influence of interface type, crystallinity, grain size, loading ratio, and host stiffness, providing practical guidance for optimizing microstructural design and host material selection. This proposed approach is broadly applicable to micromechanical systems with complex microstructural features involving chemical reaction- and/or phase-transformation-induced deformation.

36 MATERIALS SCIENCE↗

Large Scale Frequent Pattern Mining using MPI One-Sided Model

In this paper, we propose a work-stealing runtime --- Library for Work Stealing LibWS --- using MPI one-sided model for designing scalable FP-Growth --- {\em de facto} frequent pattern mining algorithm --- on large scale systems. LibWS provides locality efficient and highly scalable work-stealing techniques for load balancing on a variety of data distributions. We also propose a novel communication algorithm for FP-growth data exchange phase, which reduces the communication complexity from state-of-the-art O(p) to O(f + p/f) for p processes and f frequent attributed-ids. FP-Growth is implemented using LibWS and evaluated on several work distributions and support counts. An experimental evaluation of the FP-Growth on LibWS using 4096 processes on an InfiniBand Cluster demonstrates excellent efficiency for several work distributions (87\% efficiency for Power-law and 91% for Poisson). The proposed distributed FP-Tree merging algorithm provides 38x communication speedup on 4096 cores.

Vishnu, Abhinav↗

Comparison of Multi-Scale Nonlinear and Conventional Linear Methods for Stress Analysis of Nb 3 Sn Superconducting Magnets

Here this is an extension of the work on a multi-scale nonlinear procedure that demonstrated how to conduct nonlinear stress analysis of Nb 3 Sn superconducting accelerator magnets. The nonlinear procedure uses measured stress-strain curves of annealed copper, Nb 3 Sn strands and coil samples as inputs, which reduces the number of assumptions made for material properties—key uncertainties of any engineering analysis. The results from nonlinear analysis, semi-nonlinear analysis, and linear analysis of the same QFFB2 Nb 3 Sn quadrupole magnet under the same temperature and loads, were compared and discussed. The comparison illustrates that nonlinear stress analysis is significantly more accurate than other methods. As the superconducting coil block is a complex, composite material, it would be inadequate to assume the whole coil block to be linear, either isotropic or orthotropic. It is imperative to conduct nonlinear analysis by simulating the superconducting coil to the level of detail of the individual cables and individual strands. The nonlinear stress analysis procedure can be used to simulate not only Nb 3 Sn magnets, but also NbTi and HTS magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A software package for plasma facing component analysis and design: the Heat flux Engineering Analysis Toolkit (HEAT)

The engineering limits of plasma facing components (PFCs) constrain the allowable operational space of tokamaks. Poorly managed heat fluxes that push the PFCs beyond their limits not only degrade core plasma performance via elevated impurities, but can also result in PFC failure due to thermal stresses or melting. Simple axisymmetric assumptions fail to capture the complex interaction between 3D PFC geometry and 2D or 3D plasmas. This results in fusion systems that must either operate with increased risk or reduce PFC loads, potentially through lower core plasma performance, to maintain a nominal safety factor. High precision 3D heat flux predictions are necessary to accurately ascertain the state of a PFC given the evolution of the magnetic equilibrium. A new code, the Heat flux Engineering Analysis Toolkit (HEAT), has been developed to provide high precision 3D predictions and analysis for PFCs. HEAT couples many otherwise disparate computational tools together into a single open source python package. Magnetic equilibrium, engineering CAD, finite volume solvers, scrape off layer plasma physics, visualization, high performace computing, and more, are connected in a single web-based user interface. Linux users may use HEAT without any software prerequisites via an appImage. This manuscript introduces HEAT, discusses the software architecture, presents first HEAT results, and outlines physics modules in development.

divertor physics↗

PBX 9502 Multimode Damage Accumulation Cycles-to-Failure Study

In FY13, we performed a detailed cycles-to-failure study of PBX 9502 using 3- point bend specimens. In that study we examined the effect of temperature and cyclic frequency on the failure behavior of PBX 9502. We identified cycles-to-failure curves for samples tested at -20°C, ~19°C and 50°C and at cyclic frequencies of 0.0001 up to 1-Hz. We also did cyclic conditioning of parts in an effort to establish damage accumulation criteria that could then be used in predictive models. As follow-on to that work, in FY14 we have added multimode cycles-to-failure to our test suite. Work this year re-established the baseline cycles-to-failure behavior of the PBX 9502 material tested round ~19°C at 1-Hz and also looked at damage accumulation under a multimode loading environment. This fresh baseline development was performed to remove any time related or test rig related variables. The multimode loading was done because real-world applications are not mono-modal and we desire for our predictive capability to be robust and include more complex, realistic scenarios. In the following sections we briefly describe the test setup, we provide a summary of the new baseline results and we show the multimode cycles-to-failure data and how it compares to the mono-modal test data.

42 ENGINEERING↗

Methods for Representing Flexible, Energy-Constrained Technologies in Utility Planning Tools

Capacity expansion models are widely used by power system researchers, planners, and policy analysts to evaluate alternative power system investment scenarios. With the increasing deployment of wind and solar in the US, there has been much focus on improving the representations of variable generation (VG) technologies within capacity expansion models. Models that capture the variable net-load profiles and larger reserve requirements associated with high penetration VG systems represent an improvement to classic capacity expansion models, but fall short of capturing the complexities associated with storage technologies, such as battery energy storage (BES) and concentrating solar power with thermal energy storage (CSP with TES). While difficult to model in a capacity expansion setting, these technologies are potentially competitive sources of flexibility with the intriguing characteristics of being able to absorb VG that would otherwise be curtailed and directly contribute to renewable energy goals, respectively. In this paper we present methods for accurately representing these technologies in a large-scale capacity expansion model with high electrical and geospatial resolution. VG modeling techniques, including novel methods for capturing curtailment due to unit commitment and other hourly dispatch phenomena, are also reviewed. Modeling for a region in the southwestern United States demonstrates the economic relevance of being able to explicitly trade off the costs and capabilities of energy-constrained technologies, especially BES, against other resources in the near-term, in time to make plans for the coming decade

24 POWER TRANSMISSION AND DISTRIBUTION↗

Combined Assay Systems for the Characterisation of Historical ILW at of the Dounreay Shaft and Silo-18140

In 1955 the Dounreay nuclear power development establishment was created on the northern coast of Scotland primarily to pursue the UK Government policy of developing Fast Breeder Reactor (FBR) technology. The site operated then by the United Kingdom Atomic Energy Authority (UKAEA) saw the development, test and operation of 3 nuclear reactors, two of them FBRs, alongside fabrication and reprocessing facilities for the FBR fuel elements. From the late 1950's until 1977 Intermediate Level radioactive Waste (ILW) generated on site was disposed of into a 65 m deep, 4.6 m diameter shaft. In January 1977, an explosion thought to be caused by hydrogen generated from sodium and potassium wastes reacting with water occurred in the upper part of the shaft, thus stopping any further waste disposal. A second ILW storage facility, the ILW-Silo, started operation in 1971 to deal with the increasing volume of intermediate level waste generated on site in the mid-1960's and continued receiving waste until 1998. The decommissioning of the Shaft and Silo facilities is a challenging engineering task due to the complexity and potential hazards linked with the retrieval and handling of historical waste. Following recovery it is intended to shred the majority of the waste and load it into 200-l assay drums. Sludges would be separated and solidified within a special annulus drum to make them suitable for assay. To support the decommissioning strategies put forward by Dounreay Site Restoration Limited (DSRL), Mirion Technologies Canberra UK Ltd have designed and completed the manufacture of a pair of combined non-destructive waste assay (NDA) systems. The two identical automated ILW counters are intended to provide a means to characterise the waste materials by performing active and passive neutron measurement as well as segmented high resolution gamma spectrometry (HRGS) of 200-l sacrificial waste drums. The active neutron technique is based on the Differential Die Away (DDA) technique using a pulsed Deuterium-Tritium neutron generator to interrogate fissile material present in the waste. The active neutron measurements support, as well as the passive neutron coincidence measurements, a matrix correction capability by use of an Add-a-Source mechanism. The publication will describe in broad lines the approach proposed by DSRL in the processing of the waste retrieved from both the Shaft and Silo facilities. It will also present a description of the overall design of the NDA counters, illustrating how the measurements to be performed will allow DSRL to safely characterise the retrieved waste materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing high energy density sulfur cathodes: A multivariate approach to electrode formulation and processing

Lithium-sulfur (Li-S) batteries involve complex solid-liquid-solid phase transformations during both discharging and charging processes, where cathode materials, formulation, and structure play a crucial role. Here, a design of experiments (DoE) methodology and an empirical model are developed to systematically explore the interactions and trade-offs among cathode factors and process variables, and to obtain generalizable effects estimates for the multivariate system. Compared to the conventional one-factor-at-a-time (OFAT) approach, this work demonstrates advantages in both efficiency and accuracy by allowing the data to guide future research and decisions. Further, an optimized cathode formulation and processing parameters are predicted and validated experimentally, achieving over 1000 mAh g -1 in discharge capacity and improved cycling under practical lean electrolyte (4 µL mg -1 S) and high S-loading cathodes (>4 mg cm -2 ) conditions. The optimized cathode was scaled up and assembled into Li-S pouch cells, achieving 316 Wh kg -1 in cell-level energy, proving that the comprehensive and rigorous framework for optimizing complex systems with DoE leads to improved performance in a practical pouch cell system.

25 ENERGY STORAGE↗

Investigation on Tuning Power–Frequency Droop for Improved Grid–Forming Inverter and Synchronous Generator Transient Load Sharing

Poor transient load sharing has been observed during the parallel operation of synchronous generators (SGs) and droop-controlled grid-forming (GFM) inverter-based resources (IBRs) in islanded microgrids. This can result in overcurrent protections, causing the inverters to trip, which leads to the collapse of voltage and frequency. In this article, small-signal analysis supported by electromagnetic transients (EMTs) simulation is performed on a detailed model of a microgrid containing IBRs and an SG to identify underdamped modes and their sensitivities to the power–frequency (P-F) droop parameter. Further EMT simulation of a more complex microgrid model with multiple GFM IBRs and SGs is performed to determine whether trends identified from the modal analysis extend to cases where the number of SGs in operation may vary. The objective is to investigate the effectiveness of tuning this parameter to reduce the likelihood of overcurrents in response to load and generation disturbances. The work uncovers both fast and slow modes of concern. Primarily, the findings show that increasing the P-F droop value improves the damping of the slower mode while degrading the damping of the faster mode, leading to an upper limit on the damping improvement of the GFM IBR output current. In EMT simulations of the more complex microgrid, the greatest damping improvement still exhibits significant maximum overshoot. Furthermore, the optimal value of the P-F droop parameter is sensitive to the number of SGs in operation. The conclusion is that tuning the P-F droop parameter is not an effective means to avoid the overcurrent tripping of GFM IBRs during response to large load or generation disturbances when operating in parallel to SGs in islanded microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced EMT and Phasor-Domain Hybrid Simulation With Simulation Mode Switching Capability for Transmission and Distribution Systems

Conventional electromagnetic transient (EMT) and phasor do-main hybrid simulation approaches presently exist for transmission system level studies and their simulation efficiency is generally constrained by the EMT simulation. With an increasing number of distributed energy resources and non-conventional loads being installed in the distribution systems, it is imperative to ex-tend the hybrid simulation application to include distribution systems and integrated transmission and distribution systems. Meanwhile, it is equally important to improve the simulation efficiency as the modeling scope and complexity of the detailed system in the EMT simulation increases. To meet both requirements, this paper introduces an advanced electromagnetic transient (EMT) and phasor domain hybrid simulation approach. This approach has two outstanding features: 1) a comprehensive phasor domain modeling framework which supports positive-sequence, three-sequence, three-phase and mixed three-sequence/three-phase representations; 2) a robust and flexible simulation mode switching scheme which enables simulation switching from hybrid simulation mode back to pure phasor domain dynamic simulation mode to achieve significantly improved simulation efficiency. The proposed method has been tested on integrated transmission and distribution systems, and the results show that with the developed simulation switching feature, the total computational time is significantly reduced compared to running the hybrid simulation for the whole simulation period, while good accuracy is maintained.

Huang, Qiuhua (ORCID:0000000184577429)↗

Allocation and Operation of A Hydropneumatic Energy Storage with Building Microgrid

Behind-meter application for a recently invented hydropneumatic Ground-Level Integrated Diverse Energy Storage (GLIDES) is focused in this research. Considering possible uncertainties from solar radiation and electricity load in a building microgrid, two-stage stochastic programming is adopted for 15-min operation and a mixed-integer nonlinear stochastic model is built with integrated energy systems of GLIDES, solar panel and power generating unit. In order to make the model computationally tractable, we use sample average approximate method to decrease associated complexity with sample size and improve solving efficiency. The experimental results in deterministic and stochastic operation indicate that best candidate solution from SAA are superior to the solution from expected value problem in terms of optimality gap and variance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Physics-Informed Sparse Gaussian Process for Probabilistic Stability Analysis of Large-Scale Power System with Dynamic PVs and Loads

This work proposes a physics-informed sparse Gaussian process (SGP) for probabilistic stability assessment of large-scale power systems in the presence of uncertain dynamic PVs and loads. The differential and algebraic equations considering uncertainties from dynamic PVs and loads are reformulated to a nonlinear mapping relationship that allows the application of SGP. Thanks to the nonparametric characteristic of Gaussian process, the proposed framework does not require distributions of uncertain inputs and this distinguishes it from existing approaches. As the original Gaussian process is not scalable to large-scale systems with high dimensional uncertain inputs, this paper develops the SGP with a stochastic variational inference technique. It leads to approximately two orders of complex reduction. A data pre-processing step is also introduced to tackle the coexistence of stable and unstable cases by sample clustering and constructing separate SGPs. The probabilistic transient stability index is analyzed to assess system stability under different uncertain dynamics loads and PVs. Comparisons are performed with the sampling-based, the polynomial chaos expansion-based, and traditional Gaussian process-based methods on the modified IEEE 118-bus and Texas 2000-bus systems under various scenarios, including different levels of uncertainties and the existence of nonlinear correlations among dynamic PVs. The impacts of data quality and quantity issues are also investigated. It is shown that the proposed SGP achieves significantly improved computational efficiency while maintaining high accuracy with a limited number of data.

24 POWER TRANSMISSION AND DISTRIBUTION↗