A fragment-based approach to discovery of Receptor for Advanced Glycation End products inhibitors
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This work addresses segmentation of volumetric images of woven carbon fiber textiles from micro-tomography data. We propose a semi-supervised algorithm to classify carbon fibers that requires sparse input as opposed to completely labeled images. The main contributions are: (a) design of effective discriminative classifiers, for three-dimensional textile samples, trained on wavelet features for segmentation; (b) coupling of previous step with nonlocal means as simple, efficient alternative to the Potts model; and (c) demonstration of reuse of classifier to diverse samples containing similar content. We evaluate our work by curating test sets of voxels in the absence of a complete ground truth mask. The algorithm obtains an average 0.95 F1 score on test sets and average F1 score of 0.93 on new samples. Finally, we conclude with discussion of failure cases and propose future directions toward analysis of spatiotemporal high-resolution micro-tomography images.
The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as an open-source repository of well-characterized targeted proteomic assays. The portal is designed to curate and disseminate highly characterized, targeted mass spectrometry (MS)-based assays by providing detailed assay performance characterization data, standard operating procedures, and access to reagents. Assay content is accessed via the portal through queries to find assays targeting proteins associated with specific cellular pathways, protein complexes, or specific chromosomal regions. The position of the peptide analytes for which there are available assays are mapped relative to other features of interest in the protein, such as sequence domains, isoforms, single nucleotide polymorphisms, and post-translational modifications. The overarching goals are to enable robust quantification of all human proteins and to standardize the quantification of targeted MS-based assays to ultimately enable harmonization of results over time and across laboratories.
A federated instrument-to-edge-to-center architecture is needed to autonomously collect, transfer, store, process, curate, and archive scientific data and reduce human-in-the-loop needs with (a) common interfaces to leverage community and custom software, (b) pluggability to permit adaptable solutions, reuse, and digital twins, and (c) an open standard to enable adoption by science facilities world-wide. The Selfdriven Experiments for Science/Interconnected Science Ecosystem (INTERSECT) Open Architecture enables science breakthroughs using intelligent networked systems, instruments and facilities with autonomous experiments, “self-driving” laboratories, smart manufacturing and artificial intelligence (AI) driven design, discovery and evaluation. It creates an open federated architecture for the laboratory of the future using a novel approach, consisting of (1) science use case design patterns, (2) a system of systems architecture, and (3) a microservice architecture.
The availability and disposition of data has assumed increasing importance in large-scale computational science. Data repositories are evolving to meet new classes of requirements: compliance with government access guidelines, support for reproducibility of experimental results, and long-term availability of data products. The Constellation public data repository at the Oak Ridge Leadership Computing Facility faces these issues while being situated in one of the most productive data centers in the world. While monitoring and operational data analysis are ingrained in the operation of the OLCF’s large-scale high performance computing platforms, data repositories do not have this history of support. Problems faced by Constellation range from data size (over 7 petabytes in current holdings) to analytic complexity (detailed curation is both absolutely necessary for many data sets and absolutely impossible for humans to accomplish in any practical manner) to deployment environment (OLCF storage resources are oriented toward the needs of the compute platforms). In this paper we describe some of the challenges for collecting monitoring and analytic data from a leadership public data repository. We also discuss various strategies we are pursuing in order to address these challenges, from manual data collection to plans for introducing machine learning-based curatorial techniques.
Global climate researchers rely upon many forms of sensor data and analytical methods to help profile subtle changes in climate conditions. The U.S. Department of Energy's Atmospheric Radiation Measurement (ARM) program provides researchers with curated Value Added Products (VAPs) resulting from continuous sensor data streams, data fusion, and modeling. The ARM operations staff and software development teams (data producers) rely upon a number of techniques to ensure strict quality control (QC) and quality assurance (QA) standards are maintained. Climate researchers (data consumers) are highly interested in obtaining as much provenance (data quality, data pedigree) as possible to establish data trustworthiness. Currently all the provenance is not easily attainable or identifiable without significant efforts to extract and piece together information from configuration files, log files, codes, and status information from ARM databases. The need for a formalized approach to managing provenance became paramount with the planned addition of 120 new instruments, new data products, and data collection scaling to half a terabyte daily. Last year our research identified the need for a multi-tier provenance model to enable the data consumer easy access to the provenance for their data. This year we are leveraging the Open Provenance Model as a foundational construct that serves the needs of both the VAP producers and consumers, we are organizing the provenance in different tiers of granularity to model VAP lineage, causality at the component level within a VAP, and the causality for each time step as samples are being assembled within the VAP. This paper shares our implementation strategy and how the ARM operations staff and the climate research community can greatly benefit from this approach to more effectively assess and quantify VAP provenance.
Scientific questions of today are now more global than ever before. The answers to these questions are buried within multiple disciplines and across a diverse range of scientists and institutions. The expanse and complexity of data required by researchers often exceed the means of a single scientist. Data sharing in the form of its distributed collection and analysis is increasingly common. Collective research now takes place in what may be called 'collaboratories' or in 'centers without walls' (Clery 2006). Creating effective artifacts, which enable scientists to collaborate on data analyses, continues to be a significant challenge for today's science activities. It is rare that providing a file system abstraction on distributed data enables acceleration of scientific discoveries. By explicitly identifying and addressing the different requirements for data contributors, data curators, and data consumers, we can create a data management architecture which enables the creation of datasets that evolve over time with growing and changing data, data annotations, participants, and use rules. This involves also a crucial contribution by the teams and people collecting the data, that in addition to carefully acquire and process the measurements and to be ready to share their measurements within the scientific community, need to follow general rules that help to make their data well documented and safely stored and to maximize visibility to their works and sites. In this chapter, we provide examples of the types of functions and capabilities typically provided within the data management systems, focusing in particular on databases structures and characteristics, data practices, and data user services. Finally, the importance and advantages of collective efforts like data sharing for synthesis activities and the relative data policy options are discussed and analyzed.
Microbial taxonomy should provide adequate descriptions of bacterial, archaeal, and eukaryotic microbial diversity in ecological, clinical, and industrial environments. We re-evaluated the prokaryote species twice. It is time to revisit polyphasic taxonomy, its principles, and its practice, including its underlying pragmatic species concept. We will be able to realize an old dream of our predecessor taxonomists and build a genomic-based microbial taxonomy, using standardized and automated curation of high-quality complete genome sequences as the new gold standard.
Abstract High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution. Graphical abstract
Purpose: The aim of this study was to determine the diagnostic performance of magnetic resonance imaging (MRI)-categorized T3cd/T4 tumors for identifying high-risk stage II or stage III cancer in patients with curatively resectable colon cancer in comparison to that of multidetector computed tomography (MDCT). Materials and Methods: Thirty-eight patients with histopathologically indicated adenocarcinomas prospectively underwent MRI of the colon. Two radiologists independently and retrospectively assessed for T-category, including T3 substage (≤ T3ab vs. ≥ T3cd). The diagnostic accuracies and interreader agreements between assessments using each modality were compared using a pairwise comparison of receiver-operating characteristic curves and a weighted κ statistic, respectively. Results: Twenty-nine patients (76.3%) were histopathologically diagnosed with high-risk stage II or stage III colon cancer. The false-positive rate with MRI was lower than that with MDCT (0% vs. 7.9% for reader 1, 2.6% vs. 10.6% for reader 2). The diagnostic performance of MRI was better than that of MDCT across both readers (AUC: 0.707 vs. 0.506 [P = 0.032] for reader 1, 0.651 vs. 0.485 [P = 0.055] for reader 2). Moreover, MRI interreader agreement for the assessment of T3cd/T4 was significantly better than that of MDCT (κ = 0.821 vs. 0.391 [P = 0.017]). Conclusion: The diagnostic performance of MR imaging of the colon may be better than that of MDCT for identifying high-risk stage II or stage III cases. Particularly, colon MRI reduced the false-positive rate and improved the interreader agreement, although further studies with a larger sample size are required.
Pancreatic neuroendocrine tumors (pNETs) are rare neoplasms that secrete peptides and neuro-amines. pNETs can be sporadic or hereditary, syndromic or non-syndromic with different clinical presentations and prognoses. The role of medical imaging includes locating the tumor, assessing its extent, and evaluating the feasibility of curative surgery or cytoreduction. Pancreatic NETs have very distinctive phenotypes on CT, MRI, and PET. PET have been demonstrated to be very sensitive to detect either well-differentiated pNETs using {sup 68}Gallium somatostatin receptor (SSTR) radiotracers, or more aggressive undifferentiated pNETS using {sup 18}F-FDG. A comprehensive interpretation of multimodal imaging guides resectability and cytoreduction in pNETs. The imaging phenotype provides information on the differentiation and proliferation of pNETs, as well as the spatial and temporal heterogeneity of tumors with prognostic and therapeutic implications. This review provides a structured approach for standardized reading and reporting of medical imaging studies with a focus on PET and MR techniques. It explains which imaging approach should be used for different subtypes of pNET and what a radiologist should be looking for and reporting when interpreting these studies.
Purpose: Colorectal cancer is a commonly encountered disease that poses several diagnostic and therapeutic challenges. The inherent heterogeneity of tumor biology and propensity to relapse despite “curative” resection pose significant challenges with regard to response assessment. Although MR imaging already plays a key role in primary staging of patients with rectal carcinoma, its reliability in restaging after neoadjuvant therapy is debatable (Van der broek et al. in Dis Colon Rectum 60(3):274–283, 2017). Therefore, there is significant interest in developing additional methods which may improve diagnostic accuracy. This study aims to evaluate the role of multimodality imaging and liquid biopsy in therapeutic response assessment. Methods: Seventeen patients were enrolled into the study over a span of 24 months. All underwent hybrid PET-MRI and CT-perfusion (CT-P), prior to and following neoadjuvant therapy for locally advanced rectal carcinoma. Twelve of the 17 patients also underwent liquid biopsy, which consisted of blood sampling and analysis of circulating tumor cells (CTCs) and extracellular vesicles (EVs), including cell fragments and microparticles (MPs), using the Cell Search System (Menarini Silicon Biosystems). SUV, DWI, and ADC were calculated during PET-MRI, and several parameters were evaluated during CT-perfusion, including average perfusion, blood flow (BF), blood volume (BV), mean transit time (MTT), permeability-surface area product (PS), contrast extraction efficiency (E), and K-trans (K). Changes observed pre- and post-neoadjuvant therapy in each modality were compared to tumor response at histopathology using a modified Ryan tumor regression grading system. Results: Of the 17 patients included in the study, 14 were classified as non-responders, and 3 were classified as responders as determined by the modified Ryan Tumor Regression Grade (TRG) scoring system (Van der broek et al. in Dis Colon Rectum 60(3):274–283, 2017). When combined, blood markers and CT-P parameters (mean transit time (MTT), K-trans, and permeability-surface area product (PS)) produced the strongest models (p < 0.01). PET (SUV measurement) combined with CT-P-derived K-trans produced a marginally significant (p = 0.057) model for predicting response. MRI-derived ADC value did not provide a significant model for response prediction. Conclusion: A model of CT-P parameters plus liquid biopsy more accurately predicts tumor response than PET-MRI, CT-P alone, or liquid biopsy alone. These results suggest that in the evaluation of treatment response, liquid biopsy could provide additional information to functional imaging modalities such as CT-P and should therefore be explored further in a trial with larger sample size.
Purpose. We retrospectively evaluated the safety and efficacy of preoperative initial hepatic arterial infusion chemotherapy (HAIC) through a port-catheter system in patients with liver dysfunction due to synchronous and unresectable liver metastases. The aim of HAIC was to improve patients' clinical condition for later surgical removal of primary colorectal cancer. Methods. Port-catheter systems were placed radiologically in 21 patients (mean age 58.6 {+-} 8.1 years) with liver dysfunction due to synchronous liver metastases from colorectal cancer. Initial HAIC of 1,000 mg/m{sup 2} 5-fluorouracil was administered weekly as a 5 hr continuous infusion through this system. Surgical removal of the primary lesion was planned after HAIC improved the liver function. Results. Port-catheter system placement was successful in all patients without severe complications. Patients were followed up for a median of 309 days (range 51-998 days). After starting HAIC, no severe adverse events that caused drug loss and treatment postponement or suspension were observed in any of the patients. HAIC was performed a mean of 4.5 {+-} 3.0 times and the liver function improved in all patients. Curative (n = 18) or palliative (n = 1) surgical removal of the primary lesion was performed. The remaining 2 patients died because extrahepatic metastases developed and their performance status worsened; thus, surgery could not be performed. The median survival times of all patients and the operated patients were 309 and 386 days, respectively. Conclusion. Initial HAIC administration is a safe and efficacious method for improving liver function prior to operative resection of primary colorectal cancer in patients with liver dysfunction due to synchronous and unresectable liver metastases.
The purpose of this study was to evaluate the clinical feasibility and efficacy of transcatheter selective arterial chemoembolization (TACE) for unresectable hepatoblastoma in infants and children. The study was performed with the approval of our institutional review board. Sixteen patients (13 boys, 3 girls) with unresectable hepatoblastoma were treated one to three times with preoperative TACE in an effort to improve the surgical and clinical outcome. Their ages ranged from 50 days to 60 months, with a mean age of 20.4 months. All cases were pathologically proved hepatoblastoma by fine-needle biopsy. After an intra-arterial catheter was selectively inserted into the main feeding artery of the tumor, cycles of cisplatin (40 to 50 mg/m{sup 2}) and adriamycin (20 to 30 mg/m{sup 2}) mixed with lipiodol were given, followed by gelatin foam particles or stainless-steel coils. Tumor response was evaluated according to tumor shrinkage, {alpha}-fetoprotein (AFP) levels, and pathological findings. TACE procedure was performed one to three times, depending on the patient's response. Surgical resection was carried out when the tumor volume appeared sufficiently reduced to allow safe resection by either lobectomy or extended lobectomy. A marked reduction in tumor size associated with decreased AFP level occurred after treatment. According to paired-samples test, tumor shrinkage ranged from 19.0% to 82.0%, with a mean value of 59.2%. AFP levels decreased 99.0% to 29.0% from initial levels, with a mean decrease of 60.0%. TACE allowed subsequent complete surgical resection in 13 cases and the other 3 cases underwent partial resection. One patient underwent successful orthotopic liver transplantation after receiving TACE therapy. Pathological examination showed that the mean percentage of necrotic area in the surgical specimens was 87%. Overall survival rate at 1, 3, and 5 years was 87.5%, 68.7%, and 50%, respectively. Correspondingly, event-free survival rate was 75%, 62.5%, and 43.7%, respectively. In addition, there was no marked chemotherapeutic agent-induced toxicity noted during the observation period. We conclude that TACE is feasible, well tolerated, and effective in inducing surgical resectability of hepatoblastoma in pediatric patients, which has become an independent palliative or curative therapeutic option, especially for patients without distant metastasis.
Transcatheter arterial chemoembolization (TACE) offers a survival benefit to patients with intermediate hepatocellular carcinoma (HCC). A widely accepted TACE regimen includes administration of doxorubicin-oil emulsion followed by gelatine sponge-conventional TACE. Recently, a drug-eluting bead (DC Bead) has been developed to enhance tumor drug delivery and reduce systemic availability. This randomized trial compares conventional TACE (cTACE) with TACE with DC Bead for the treatment of cirrhotic patients with HCC. Two hundred twelve patients with Child-Pugh A/B cirrhosis and large and/or multinodular, unresectable, N0, M0 HCCs were randomized to receive TACE with DC Bead loaded with doxorubicin or cTACE with doxorubicin. Randomization was stratified according to Child-Pugh status (A/B), performance status (ECOG 0/1), bilobar disease (yes/no), and prior curative treatment (yes/no). The primary endpoint was tumor response (EASL) at 6 months following independent, blinded review of MRI studies. The drug-eluting bead group showed higher rates of complete response, objective response, and disease control compared with the cTACE group (27% vs. 22%, 52% vs. 44%, and 63% vs. 52%, respectively). The hypothesis of superiority was not met (one-sided P = 0.11). However, patients with Child-Pugh B, ECOG 1, bilobar disease, and recurrent disease showed a significant increase in objective response (P = 0.038) compared to cTACE. DC Bead was associated with improved tolerability, with a significant reduction in serious liver toxicity (P < 0.001) and a significantly lower rate of doxorubicin-related side effects (P = 0.0001). TACE with DC Bead and doxorubicin is safe and effective in the treatment of HCC and offers a benefit to patients with more advanced disease.
Radiofrequency ablation of lung tumours is a curative technique that is newly considered being offered to nonsurgical patients. It is of major interest because it enables local destruction of the tumour without surgery and spares healthy parenchyma. However, some patients have previous serious respiratory failure, thus ruling out mechanical ventilation. To operate with the patient under thoracic epidural is an answer to this problem. Our experience shows that the procedure is able to be performed completely without converting to general anaesthesia.
Today, radiofrequency ablation (RFA) of primary and metastatic lung tumor is increasingly used. Because RFA is most often used with curative intent, preablation workup must be a preoperative workup. General anesthesia provides higher feasibility than conscious sedation. The electrode positioning must be performed under computed tomography for sake of accuracy. The delivery of RFA must be adapted to tumor location, with different impedances used when treating tumors with or without pleural contact. The estimated rate of incomplete local treatment at 18 months was 7% (95% confidence interval, 3-14) per tumor, with incomplete treatment depicted at 4 months (n = 1), 6 months (n = 2), 9 months (n = 2), and 12 months (n = 2). Overall survival and lung disease-free survival at 18 months were, respectively, 71 and 34%. Size is a key point for tumor selection because large size is predictive of incomplete local treatment and poor survival. The ratio of ablation volume relative to tumor volume is predictive of complete ablation. Follow-up computed tomography that relies on the size of the ablation zone demonstrates the presence of incomplete ablation. Positron emission tomography might be an interesting option. Chest tube placement for pneumothorax is reported in 8 to 12%. Alveolar hemorrhage and postprocedure hemoptysis occurred in approximately 10% of procedures and rarely required specific treatment. Death was mostly related to single-lung patients and hilar tumors. No modification of forced expiratory volume in the first second between pre- and post-RFA at 2 months was found. RFA in the lung provides a high local efficacy rate. The use of RFA as a palliative tool in combination with chemotherapy remains to be explored.
Purpose: Irreversible electroporation (IRE) is a newly developed nonthermal tissue-ablation technique in which high-voltage electrical pulses of microsecond duration are applied to induce irreversible permeabilisation of the cell membrane, presumably through nanoscale defects in the lipid bilayer, leading to apoptosis. The purpose of this study was to assess the feasibility and safety of ablating renal cell carcinoma (RCC) tissue by IRE. Methods: Six patients scheduled for curative resection of RCC were included. IRE was performed during anaesthesia immediately before the resection with electrographic synchronisation. Central haemodynamics were recorded before and 5 min after electroporation. Five-channel electrocardiography (ECG) was used for detailed analysis of ST waveforms. Blood sampling and 12-lead ECG were performed before, during, and at scheduled intervals after the intervention. Results: Analysis of ST waveforms and axis deviations showed no relevant changes during the entire study period. No changes in central haemodynamics were seen 5 min after IRE. Similarly, haematological, serum biochemical, and ECG variables showed no relevant differences during the investigation period. No changes in cardiac function after IRE therapy were found. One case of supraventricular extrasystole was encountered. Initial histopathologic examination showed no immediate adverse effects of IRE (observation of delayed effects will require a different study design). Conclusion: IRE seems to offer a feasible and safe technique by which to treat patients with kidney tumours and could offer some potential advantages over current thermal ablative techniques.