Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cycle Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

As an alternative to a steam cycle, a supercritical carbon dioxide (sCO2) power cycle can be considered. Able et. al performed an analysis of an sCO2 cycle in a 2x2-1 configuration; however, this study did not include carbon capture. Previous studies assumed an H-Frame turbine and added a solvent based 95% carbon capture system and performed a levelized cost of electricity (LCOE) optimization for the plant. Their results suggest a LCOE slightly better than when using a steam cycle. In the study, steam is still generated in the heat recovery sections for the solvent regeneration in the carbon capture stripper reboiler. H-Frame gas turbines are also assumed. This work starts with the optimal design from the mentioned work to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. H-Frame gas turbine off-design performance and exhaust conditions to the heat recovery section are obtained from commercial software, Thermoflow®. The CO2 turbomachinery, heat exchangers and other unit operations are sized and implemented in an Aspen Plus® model. Using the gas turbine exhaust conditions as input, the sCO2 cycle is optimized by adjusting stream split ratios, sCO2 circulation flowrate and compressor speed for maximum efficiency. This is done while keeping the target 95% CO2 capture.

Chinen, Anderson Soares↗

Reliability Testing of NASA Piezocomposite Actuators

NASA Langley Research Center has developed a low-cost piezocomposite actuator which has application for controlling vibrations in large inflatable smart space structures, space telescopes, and high performance aircraft. Tests show the NASA piezocomposite device is capable of producing large, directional, in-plane strains on the order of 2000 parts-per-million peak-to-peak, with no reduction in free-strain performance to 100 million electrical cycles. This paper describes methods, measurements, and preliminary results from our reliability evaluation of the device under externally applied mechanical loads and at various operational temperatures. Tests performed to date show no net reductions in actuation amplitude while the device was moderately loaded through 10 million electrical cycles. Tests were performed at both room temperature and at the maximum operational temperature of the epoxy resin system used in manufacture of the device. Initial indications are that actuator reliability is excellent, with no actuator failures or large net reduction in actuator performance.

Wilkie, W.↗

Cycle life test. Evaluation program for secondary spacecraft cells

Considerable research is being done to find more efficient and reliable means of starting electrical energy for orbiting satellites. Rechargeable cells offer one such means. A test program is described which has been established in order to further the evaluation of certain types of cells and to obtain performance and failure data as an aid to their continued improvement. The purpose of the program is to determine the cycling performance capabilities of packs of cells under different load and temperature conditions. The various kinds of cells tested were nickel-cadmium, silver-cadmium, and silver-zinc sealed cells. A summary of the results of the life cycling program is given in this report.

Harkness, J. D.↗

Lunar base heat pump, phase 1

This report describes the Phase 1 process and analysis used to select a refrigerant and thermodynamic cycle as the basis of a vapor compression heat pump requiring a high temperature lift, then to perform a preliminary design to implement the selected concept, including major component selection. Use of a vapor compression heat pump versus other types was based on prior work performed for the Electric Power Research Institute. A high lift heat pump is needed to enable a thermal control system to remove heat down to 275 K from a habitable volume when the external thermal environment is severe. For example, a long-term lunar base habitat will reject heat from a space radiator to a 325 K environment. The first step in the selection process was to perform an optimization trade study, quantifying the effect of radiator operating temperature and heat pump efficiency on total system mass; then, select the radiator operating temperature corresponding to the lowest system mass. Total system mass included radiators, all heat pump components, and the power supply system. The study showed that lunar night operation, with no temperature lift, dictated the radiator size. To operate otherwise would require a high mass penalty to store power. With the defined radiation surface, and heat pump performances assumed to be from 40 percent to 60 percent of the Carnot ideal, the optimum heat rejection temperature ranged from 387 K to 377 K, as a function of heat pump performance. Refrigerant and thermodynamic cycles were then selected to best meet the previously determined design conditions. The system was then adapted as a ground-based prototype lifting temperature to 360 K (versus 385 K for flight unit) and using readily available commercial-grade components. Over 40 refrigerants, separated into wet and dry compression behavioral types, were considered in the selection process. Refrigerants were initially screened for acceptable critical temperature. The acceptable refrigerants were analyzed in ideal single and two-stage thermodynamic cycles. Top candidates were analyzed assuming realistic component limits and system pressure drops, and were evaluated for other considerations such as safety, environmental impact, and commercial availability. A maximum coefficient of performance (COP) of 56 percent of the Carnot ideal was achievable for a three-stage CFC-11 cycle operating under the flight conditions above. The program was completed by defining a control scheme and by researching and selecting the major components, compressor and heat exchangers, that could be used to implement the thermodynamic cycle selected. Special attention was paid to using similar technologies for the SIRF and flight heat pumps resulting in the commercially available equivalent of the flight unit. A package concept was generated for the components selected and mass and volume estimated.

Goldman, Jeffrey H.↗

A simple performance calculation method for LH2/LOX engines with different power cycles

A simple method for the calculation of the specific impulse of an engine with a gas generator cycle is presented. The solution is obtained by a power balance between turbine and pump. Approximate equations for the performance of the combustion products of LH2/LOX are derived. Performance results are compared with solutions of different engine types.

Schmucker, R. H.↗

Computer modeling of a regenerative solar-assisted Rankine power cycle

A detailed interpretation of the computer program that describes the performance of one of these cycles; namely, a regenerative Rankine power cycle is presented. Water is used as the working medium throughout the cycle. The solar energy collected at relatively low temperature level presents 75 to 80% of the total heat demand and provides mainly the latent heat of vaporization. Another energy source at high temperature level superheats the steam and supplements the solar energy share. A program summary and a numerical example showing the sequency of computations are included. The outcome from the model comprises line temperatures, component heat rates, specific steam consumption, percentage of solar energy contribution, and the overall thermal efficiency.

Lansing, F. L.↗

Computer program for analysis of split-Stirling-cycle cryogenic coolers

A computer program for predicting the detailed thermodynamic performance of split-Stirling-cycle refrigerators has been developed. The mathematical model includes the refrigerator cold head, free-displacer/regenerator, gas transfer line, and provision for modeling a mechanical or thermal compressor. To allow for dynamic processes (such as aerodynamic friction and heat transfer) temperature, pressure, and mass flow rate are varied by sub-dividing the refrigerator into an appropriate number of fluid and structural control volumes. Of special importance to modeling of cryogenic coolers is the inclusion of real gas properties, and allowance for variation of thermo-physical properties such as thermal conductivities, specific heats and viscosities, with temperature and/or pressure. The resulting model, therefore, comprehensively simulates the split-cycle cooler both spatially and temporally by reflecting the effects of dynamic processes and real material properties.

Brown, M. T.↗

Performance and Mass Modeling Subtleties in Closed-Brayton-Cycle Space Power Systems

Contents include the following: 1. Closed-Brayton-cycle (CBC) thermal energy conversion is one available option for future spacecraft and surface systems. 2. Brayton system conceptual designs for milliwatt to megawatt power converters have been developed 3. Numerous features affect overall optimized power conversion system performance: Turbomachinery efficiency. Heat exchanger effectiveness. Working-fluid composition. Cycle temperatures and pressures.

Barrett, Michael J.↗

Potential performance improvement using a reacting gas (nitrogin tetroxide) as the working fluid in a closed Brayton cycle

The results of an analysis to estimate the performance that could be obtained by using a chemically reacting gas (nitrogen tetroxide) as the working fluid in a closed Brayton cycle are presented. Compared with data for helium as the working fluid, these results indicate efficiency improvements from 4 to 90 percent, depending on turbine inlet temperature, pressures, and gas residence time in heat transfer equipment.

Stochl, R. J.↗

Premix fuels study applicable to duct burner conditions for a variable cycle engine

Emission levels and performance of a premixing Jet-A/air duct burner were measured at reference conditions representative of take-off and cruise for a variable cycle engine. In a parametric variation sequence of tests, data were obtained at inlet temperatures of 400, 500 and 600K at equivalence ratios varying from 0.9 to the lean stability limit. Ignition was achieved at all the reference conditions although the CO levels were very high. Significant nonuniformity across the combustor was observed for the emissions at the take-off condition. At a reference Mach number of 0.117 and an inlet temperature of 600K, corresponding to a simulated cruise condition, the NOx emission level was approximately 1 gm/kg-fuel.

Venkataramani, K. S.↗

Performance and Stability Characteristics of a Uni-Element Swirl Injector for Oxygen-Rich Stage Combustion Cycles

A uni-element liquid propellant combustion performance and instability study for liquid RP-1 and hot oxygen-rich pre-burner products was conducted, at a chamber pressure of about 1000 psi. using flush and recessed swirl injectors. High-frequency pressure transducer measurements were analyzed to yield the characteristic frequencies which were compared to expected frequencies of the chamber. Modes, which were discovered to be present within the main chamber included, the first longitudinal, detected at approximately 1950 Hz, and the second longitudinal mode at approximately 3800 Hz. An additional first longitudinal quarter wave mode was measured at a frequency of approximately 23000 Hz for the recessed swirl injector configuration. The characteristic instabilities resulting from these experiments were relatively weak averaging 0.2% to 0.3% of the chamber pressure.

Pal, S.↗

Multilayer Architecture Barriers for High Temperature Nuclear Applications

Innovative thin film multilayer metal/ceramic barrier coatings have been developed by Argonne National Laboratory to protect fuel cladding against different phenomena that can be encountered under the harsh operating conditions of advanced nuclear reactors. One phenomenon is Fuel-Cladding Chemical Interaction (FCCI), which can represent a challenge to the performance of steel-clad metallic fuels in sodium-cooled fast reactors (SFRs), especially when operating to high burnups at elevated cladding temperatures, and long fuel residence time. Another phenomenon is the corrosion of zirconium-based cladding under prototypic boiling water reactor (BWR) conditions and associated cladding during off normal conditions, including loss of coolant accidents (LOCA). This work provides details of the development and testing of a thin film (few microns) multilayer metal/ceramic (CrY/Y 2 O 3 ) coatings on steel cladding and its performance against FCCI. The coating architecture evolved through systematic mechanical testing, radiation tolerance assessments, and high-temperature diffusion studies from a preliminary multilayer concept to an optimized high-performance design. The optimized structure leverages stoichiometric Y 2 O 3 for its exceptional radiation stability, chemical inertness, and ultra-low fission product diffusivity (e.g., Ce diffusivity ~10 -20 m 2 /s in irradiated Y 2 O 3 at 650 °C). This is paired with ductile chromium-rich interlayers (Cr 95 Y 5 ), which significantly enhance fracture toughness and mechanical resilience. Design refinements, including increased ceramic layer thickness and optimized Cr–Y interlayer composition, eliminated fracture propagation and preserved coating integrity under extreme mechanical stress (>10× typical reactor conditions) and prolonged radiation exposure (~300 dpa). Those conditions are well beyond expected conditions during normal operations in SFR, and cover some of the transient conditions as well. In addition, the coating deposition was demonstrated to be applied uniformly to the inner surface of steel tubes representing prototypic SFR cladding. Another phenomenon under consideration in this work is the corrosion of zirconium-based cladding under prototypic boiling water reactor (BWR) conditions and associated off normal conditions including loss of coolant accident (LOCA). Another multilayer thin film coating is considered for mitigation of this phenomenon, where a coating of yttrium aluminum and yttrium aluminum ceramic/metal thin film coating. Preliminary results on the coating performance during high temperature thermal cycling (up to 1000 C) have shown promising performance of the coating. On-going optimization of the coating will continue in FY26.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IPAC-Inlet Performance Analysis Code

A series of analyses have been developed which permit the calculation of the performance of common inlet designs. The methods presented are useful for determining the inlet weight flows, total pressure recovery, and aerodynamic drag coefficients for given inlet geometric designs. Limited geometric input data is required to use this inlet performance prediction methodology. The analyses presented here may also be used to perform inlet preliminary design studies. The calculated inlet performance parameters may be used in subsequent engine cycle analyses or installed engine performance calculations for existing uninstalled engine data.

Barnhart, Paul J.↗

Identifying Outside Influences as Latent Factors to Risk in Human Performance

During the Acquisition Life Cycle for a program, there are several opportunities for the system in design to be adjusted in accordance with its changing landscape as it is being shaped by evolving policy and organizational culture. Human Systems Integration is integral to identifying these opportunities of change as there are a set number of activities that may account for altered operational states, human performance deviations, and overall component engagement if HSI is enacted early enough in the life cycle. Some changes that occur in the operational environment may not be accounted for since the organizational culture and practices are not currently a part of the HSI focus. Likewise, policy changes themselves from a top-to-bottom analysis may not have the appearance of effecting human performance until having gone through a trail-and-error period. Workarounds to adjust for unforeseen policy affects become the system's solution that usually includes changes in the training and education of the operators, maintainers, and support personnel. A system full of workarounds and off-normal practices, that cause operators to disregard the purpose of the design, coupled with the false notion that these activities are proven for successful system operation, is the very definition of “an accident waiting to happen”. Unforeseen changes in policies and practices that cause new and unusual activities to successfully and keep the system running, should be considered latent factors that may cause a potential mishap, and not part of the resilience that humans provide to the successful operation of the system. This presentation will explore how latent factors may find their way into system operations and how they can be identified and addressed.

Human Systems Integration↗

Analysis of a topping-cycle, aircraft, gas-turbine-engine system which uses cryogenic fuel

A topping-cycle aircraft engine system which uses a cryogenic fuel was investigated. This system consists of a main turboshaft engine that is mechanically coupled (by cross-shafting) to a topping loop, which augments the shaft power output of the system. The thermodynamic performance of the topping-cycle engine was analyzed and compared with that of a reference (conventional) turboshaft engine. For the cycle operating conditions selected, the performance of the topping-cycle engine in terms of brake specific fuel consumption (bsfc) was determined to be about 12 percent better than that of the reference turboshaft engine. Engine weights were estimated for both the topping-cycle engine and the reference turboshaft engine. These estimates were based on a common shaft power output for each engine. Results indicate that the weight of the topping-cycle engine is comparable with that of the reference turboshaft engine.

Turney, G. E.↗

Regenerative superheated steam turbine cycles

PRESTO computer program was developed to analyze performance of wide range of steam turbine cycles with special attention given to regenerative superheated steam turbine cycles. It can be used to model standard turbine cycles, including such features as process steam extraction, induction and feedwater heating by external sources, peaking, and high back pressure. Expansion line efficiencies, exhaust loss, leakages, mechanical losses, and generator losses are used to calculate cycle heat rate and generator output. Program provides power engineer with flexible aid for design and analysis of steam turbine systems.

Fuller, L. C.↗