Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIGESTIVE SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Prognosis of Esophageal Cancer Patients With Pathologic Complete Response After Preoperative Concurrent Chemoradiotherapy

Purpose: To define failure patterns and predictive factors in esophageal cancer patients who had a pathologic complete response (pCR) after preoperative concurrent chemoradiotherapy (PCRT). Methods and Materials: We performed a retrospective analysis of 61 esophageal cancer patients who were enrolled in prospective studies and showed pCR after PCRT. All of the patients had squamous cell carcinoma. Of the patients, 40 were treated with hyperfractionated radiotherapy (4,560 cGy in 28 fractions) with 5-fluorouracil (5-FU) and cisplatin (FP), and 21 patients received conventional fractionation radiotherapy with capecitabine and cisplatin (XP). Results: The median follow-up time was 45.2 months (range, 6.5-162.3 months). The 5-year overall survival (OS) and disease-free survival rates (DFS) were 60.2% and 80.4%, respectively. In univariate analysis, age and lymph node (LN) metastasis were poor prognostic factors for OS, and pretreatment weight loss (>2 kg) was a poor prognostic factor for DFS. In multivariate analysis, lymph node metastasis and pretreatment weight loss were independent prognostic factors for OS and DFS. Nine patients (15%) had disease recurrence. Of the nine patients, 5 patients had locoregional failure, 1 patients had distant metastasis, and 3 patients had distant and locoregional failure. In-field failure occurred in 5 patients; out-of-field failure occurred in 1 patient; both in-field and out-of-field failure occurred in 2 patients; and both marginal and out-of-field failure occurred in 1 patient. Conclusions: Even in pCR patients, the most common failure site was within the radiation field, which suggests that more efficient local treatment is needed. Tumor recurrence was more common in patients with older age and with pretreatment weight loss.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thymidylate Synthase Gene Polymorphism Affects the Response to Preoperative 5-Fluorouracil Chemoradiation Therapy in Patients With Rectal Cancer

Purpose: This study aims to correlate thymidylate synthase (TS) gene polymorphisms with the tumor response to preoperative 5-fluorouracil (5-FU)-based chemoradiation therapy (CRT) in patients with rectal cancer. Methods and Materials: Forty-four patients with rectal cancer treated with 5-FU-based preoperative CRT were prospectively enrolled in this study. Thymidylate synthase expression and TS gene polymorphisms were evaluated in tumor obtained before preoperative CRT and were correlated with the pathologic response, as assessed by histopathologic staging (pTNM) and tumor regression grade. Results: Patients exhibited 2R/3R and 3R/3R tandem repeat polymorphisms in the TS gene. With regard to TS expression in these genotypes, 2R/3RC and 3RC/3RC were defined as the low-expression group and 2R/3RG, 3RC/3RG, and 3RG/3RG as the high-expression group. There was no significant correlation between TS expression and tumor response. There was no significant difference in the tumor response between patients homozygous for 3R/3R and patients heterozygous for 2R/3R. However, 13 of 14 patients in the low-expression group with a G>C single-nucleotide polymorphism (SNP) (2R/3RC [n = 5] or 3RC/3RC [n = 9]) exhibited a significantly greater tumor downstaging rate, as compared with only 12 of 30 patients in the high-expression group without the SNP (2R/3RG [n = 10], 3RC/3RG [n = 9], or 3RG/3RG [n = 11]) (p = 0.001). The nodal downstaging rate was also significantly greater in this low-expression group, as compared with the high-expression group (12 of 14 vs. 14 of 30, p = 0.014). However, there was no significant difference in the tumor regression grade between these groups. Conclusions: This study suggests that SNPs within the TS enhancer region affect the tumor response to preoperative 5-FU-based CRT in rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parameters Favorable to Intraprostatic Radiation Dose Escalation in Men With Localized Prostate Cancer

Purpose: To identify , within the framework of a current Phase I trial, whether factors related to intraprostatic cancer lesions (IPLs) or individual patients predict the feasibility of high-dose intraprostatic irradiation. Methods and Materials: Endorectal coil MRI scans of the prostate from 42 men were evaluated for dominant IPLs. The IPLs, prostate, and critical normal tissues were contoured. Intensity-modulated radiotherapy plans were generated with the goal of delivering 75.6 Gy in 1.8-Gy fractions to the prostate, with IPLs receiving a simultaneous integrated boost of 3.6 Gy per fraction to a total dose of 151.2 Gy, 200% of the prescribed dose and the highest dose cohort in our trial. Rectal and bladder dose constraints were consistent with those outlined in current Radiation Therapy Oncology Group protocols. Results: Dominant IPLs were identified in 24 patients (57.1%). Simultaneous integrated boosts (SIB) to 200% of the prescribed dose were achieved in 12 of the 24 patients without violating dose constraints. Both the distance between the IPL and rectum and the hip-to-hip patient width on planning CT scans were associated with the feasibility to plan an SIB (p = 0.002 and p = 0.0137, respectively). Conclusions: On the basis of this small cohort, the distance between an intraprostatic lesion and the rectum most strongly predicted the ability to plan high-dose radiation to a dominant intraprostatic lesion. High-dose SIB planning seems possible for select intraprostatic lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Prolonged Fraction Delivery Times Simulating IMRT on Cultured Nasopharyngeal Carcinoma Cell Killing

Purpose: To determine the impact of prolonged fraction delivery times (FDTs) simulating intensity-modulated radiotherapy (IMRT) on cultured nasopharyngeal carcinoma (NPC) cell killing. Methods and Material: Cultured NPC cell lines CNE1 and CNE2 were used in this study. The biological effectiveness of fractionated irradiation protocols simulating conventional external beam radiotherapy and IMRT (FDT of 15, 36, and 50 minutes) was estimated with standard colony assay, and the differences in cell surviving fractions after irradiation with different protocols were tested by use of the paired t test. The impact degree of prolonged FDTs (from 8 to 50 minutes) on cell killing was also assessed by the dose-modifying factors, which were estimated by comparing the effectiveness of intermittently delivered 2 Gy with that of continuously delivered 1.5 to 2 Gy. Results: The cell surviving fractions of both CNE1 and CNE2 after fractionated irradiation simulating IMRT were higher than those simulating conventional external beam radiotherapy (p < 0.05). The dose-modifying factors for a fraction dose of 2 Gy increased from 1.05 to 1.18 for CNE1 and from 1.05 to 1.11 for CNE2 with the FDT being prolonged from 15 to 50 minutes. Conclusions: This study showed that the prolonged FDTs simulating IMRT significantly decreased the cell killing in both CNE1 and CNE2 cell lines, and these negative effects increased with the FDT being prolonged from 15 to 50 minutes. These effects, if confirmed by in vivo and clinical studies, need to be considered in designing IMRT treatments for NPC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Evaluation of the Biologic Effectiveness Factors of Boron Neutron Capture Therapy (BNCT) in a Human Colon Carcinoma Cell Line

Purpose: DNA lesions produced by boron neutron capture therapy (BNCT) and those produced by gamma radiation in a colon carcinoma cell line were analyzed. We have also derived the relative biologic effectiveness factor (RBE) of the neutron beam of the RA-3- Argentine nuclear reactor, and the compound biologic effectiveness (CBE) values for p-boronophenylalanine ({sup 10}BPA) and for 2,4-bis ({alpha},{beta}-dihydroxyethyl)-deutero-porphyrin IX ({sup 10}BOPP). Methods and Materials: Exponentially growing human colon carcinoma cells (ARO81-1) were distributed into the following groups: (1) BPA (10 ppm {sup 10}B) + neutrons, (2) BOPP (10 ppm {sup 10}B) + neutrons, (3) neutrons alone, and (4) gamma rays ({sup 60}Co source at 1 Gy/min dose-rate). Different irradiation times were used to obtain total absorbed doses between 0.3 and 5 Gy ({+-}10%) (thermal neutrons flux = 7.5 10{sup 9} n/cm{sup 2} sec). Results: The frequency of micronucleated binucleated cells and the number of micronuclei per micronucleated binucleated cells showed a dose-dependent increase until approximately 2 Gy. The response to gamma rays was significantly lower than the response to the other treatments (p < 0.05). The irradiations with neutrons alone and neutrons + BOPP showed curves that did not differ significantly from, and showed less DNA damage than, irradiation with neutrons + BPA. A decrease in the surviving fraction measured by 3-(4,5-dimetiltiazol-2-il)-2,5-difeniltetrazolium bromide (MTT) assay as a function of the absorbed dose was observed for all the treatments. The RBE and CBE factors calculated from cytokinesis block micronucleus (CBMN) and MTT assays were, respectively, the following: beam RBE: 4.4 {+-} 1.1 and 2.4 {+-} 0.6; CBE for BOPP: 8.0 {+-} 2.2 and 2.0 {+-} 1; CBE for BPA: 19.6 {+-} 3.7 and 3.5 {+-} 1.3. Conclusions: BNCT and gamma irradiations showed different genotoxic patterns. To our knowledge, these values represent the first experimental ones obtained for the RA-3 in a biologic model and could be useful for future experimental studies for the application of BNCT to colon carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Method for the Prediction of Late Organ-at-Risk Toxicity After Radiotherapy of the Prostate Using Equivalent Uniform Dose

Purpose: To evaluate the predictive value of equivalent uniform doses (EUD) for late bladder and rectal toxicity after high-dose three-dimensional conformal radiation therapy (3D-CRT) to the prostate. Materials and Methods: Using the method developed by Kutcher et al., EUDs for whole bladder and rectum were calculated from the dose-volume histograms of 180 patients with localized prostate cancer treated to 70-74 Gy with 3D-CRT. Late complications were recorded using the Radiation Therapy Oncology Group scale, correlated against EUD and known physical predictive indicators. Results: EUD is an independent prognostic factor for Grade 2+ long-term rectal and bladder toxicity after radiation treatment to the prostate. Patients receiving an EUD >63.1 Gy to the rectum have a statistically significant (10% vs. 30%; p = 0.002) higher risk of developing Grade 2+ late complications. Patients receiving an EUD >53.4 Gy to the bladder have a statistically significant (10% vs. 33%; p = 0.001) higher risk of developing Grade 2+ late complications. Conclusions: It has been demonstrated that EUD is a strong independent predictive factor for Grade 2+ late complications after 3D-CRT to the prostate. Threshold values have been demonstrated for both bladder and rectum, above which there is a clinically significant increased risk of complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfraction Liver Shape Variability and Impact on GTV Position During Liver Stereotactic Radiotherapy Using Abdominal Compression

Purpose: For patients receiving liver stereotactic body radiotherapy (SBRT), abdominal compression can reduce organ motion, and daily image guidance can reduce setup error. The reproducibility of liver shape under compression may impact treatment delivery accuracy. The purpose of this study was to measure the interfractional variability in liver shape under compression, after best-fit rigid liver-to-liver registration from kilovoltage (kV) cone beam computed tomography (CBCT) scans to planning computed tomography (CT) scans and its impact on gross tumor volume (GTV) position. Methods and Materials: Evaluable patients were treated in a Research Ethics Board-approved SBRT six-fraction study with abdominal compression. Kilovoltage CBCT scans were acquired before treatment and reconstructed as respiratory sorted CBCT scans offline. Manual rigid liver-to-liver registrations were performed from exhale-phase CBCT scans to exhale planning CT scans. Each CBCT liver was contoured, exported, and compared with the planning CT scan for spatial differences, by use of in house-developed finite-element model-based deformable registration (MORFEUS). Results: We evaluated 83 CBCT scans from 16 patients with 30 GTVs. The mean volume of liver that deformed by greater than 3 mm was 21.7%. Excluding 1 outlier, the maximum volume that deformed by greater than 3 mm was 36.3% in a single patient. Over all patients, the absolute maximum deformations in the left-right (LR), anterior-posterior (AP), and superior-inferior directions were 10.5 mm (SD, 2.2), 12.9 mm (SD, 3.6), and 5.6 mm (SD, 2.7), respectively. The absolute mean predicted impact of liver volume displacements on GTV by use of center of mass displacements was 0.09 mm (SD, 0.13), 0.13 mm (SD, 0.18), and 0.08 mm (SD, 0.07) in the left-right, anterior-posterior, and superior-inferior directions, respectively. Conclusions: Interfraction liver deformations in patients undergoing SBRT under abdominal compression after rigid liver-to-liver registrations on respiratory sorted CBCT scans were small in most patients (<5 mm).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SmartArc-Based Volumetric Modulated Arc Therapy for Oropharyngeal Cancer: A Dosimetric Comparison With Both Intensity-Modulated Radiation Therapy and Helical Tomotherapy

Purpose: To investigate the roles of volumetric modulated arc therapy with SmartArc (VMAT-S), intensity-modulated radiation therapy (IMRT), and helical tomotherapy (HT) for oropharyngeal cancer using a simultaneous integrated boost (SIB) approach. Methods and Materials: Eight patients treated with IMRT were selected at random. Plans were computed for both IMRT and VMAT-S (using Pinnacle TPS for an Elekta Infinity linac) along with HT. A three-dose level prescription was used to deliver 70 Gy, 63 Gy, and 58.1 Gy to regions of macroscopic, microscopic high-risk, and microscopic low-risk disease, respectively. All doses were given in 35 fractions. Comparisons were performed on dose-volume histogram data, monitor units per fraction (MU/fx), and delivery time. Results: VMAT-S target coverage was close to that achieved by IMRT, but inferior to HT. The conformity and homogeneity within the PTV were improved for HT over all strategies. Sparing of the organs at risk (OAR) was achieved with all modalities. VMAT-S (along with HT) shortened delivery time (mean, -38%) and reduced MU/fx (mean, -28%) compared with IMRT. Conclusion: VMAT-S represents an attractive solution because of the shorter delivery time and the lower number of MU/fx compared with IMRT. However, in this complex clinical setting, current VMAT-S does not appear to provide any distinct advantage compared with helical tomotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Reduction Study in Vaginal Balloon Packing Filled With Contrast for HDR Brachytherapy Treatment;HDR; Uterine cervix cancer; Vaginal balloon packing; Contrast; Monte Carlo

Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken with each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Radiotherapy of Primary Lung Cancer and Other Targets: Results of Consultant Meeting of the International Atomic Energy Agency

To evaluate the current status of stereotactic body radiotherapy (SBRT) and identify both advantages and disadvantages of its use in developing countries, a meeting composed of consultants of the International Atomic Energy Agency was held in Vienna in November 2006. Owing to continuous developments in the field, the meeting was extended by subsequent discussions and correspondence (2007-2010), which led to the summary presented here. The advantages and disadvantages of SBRT expected to be encountered in developing countries were identified. The definitions, typical treatment courses, and clinical results were presented. Thereafter, minimal methodology/technology requirements for SBRT were evaluated. Finally, characteristics of SBRT for developing countries were recommended. Patients for SBRT should be carefully selected, because single high-dose radiotherapy may cause serious complications in some serial organs at risk. Clinical experiences have been reported in some populations of lung cancer, lung oligometastases, liver cancer, pancreas cancer, and kidney cancer. Despite the disadvantages expected to be experienced in developing countries, SBRT using fewer fractions may be useful in selected patients with various extracranial cancers with favorable outcome and low toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anal Cancer: An Examination of Radiotherapy Strategies

The Radiation Therapy Oncology Group 9811, ACCORD-03, and ACT II Phase III trials in anal cancer showed no benefit for cisplatin-based induction and maintenance chemotherapy, or radiation dose-escalation >59 Gy. This review examines the efficacy and toxicity of chemoradiation (CRT) in anal cancer, and discusses potential alternative radiotherapy strategies. The evidence for the review was compiled from randomized and nonrandomized trials of radiation therapy and CRT. A total of 103 retrospective/observational studies, 4 Phase I/II studies, 16 Phase II prospective studies, 2 randomized Phase II studies, and 6 Phase III trials of radiotherapy or chemoradiation were identified. There are no meta-analyses based on individual patient data. A 'one-size-fits-all' approach for all stages of anal cancer is inappropriate. Early T1 tumors are probably currently overtreated, whereas T3/T4 lesions might merit escalation of treatment. Intensity-modulated radiotherapy or the integration of biological therapy may play a role in future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Reproducibility in Pancreatic Position Based on Four-Dimensional Computed Tomography

Purpose: To assess the interfractional positional variation of the pancreas using four-dimensional computed tomography (4D-CT) and to determine the suitable phase of respiration for dose delivery methods to account for pancreatic tumor motion. Methods and Materials: Fifteen patients with pancreatic cancer were enrolled in this study. For each patient, 4D-CT scans were performed at CT simulation and three times during the course of treatment. Regions of interest were set to the intrapancreatic bile ducts as a surrogate for pancreatic position. The centroids of the regions of interest were calculated at end-inhalation and end-exhalation of the respiration phase. The ranges of respiratory motion and interfractional positional variation were evaluated in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions. Results: The medians of respiratory motion were 1.1 mm (range, 0.0-9.8 mm), 1.5 mm (range, 0.0-7.0 mm), and 5.0 mm (range, 0.0-12.5 mm) in the LR, AP, and SI directions, respectively. The means {+-} SDs of the interfractional positional variation at end-inhalation were 0.9 {+-} 5.1 mm (range, -9.2 to 15.6 mm), -1.9 {+-} 3.9 mm (range, -12.8 to 6.4 mm), and -1.3 {+-} 6.9 mm (range, -15.0 to 13.7 mm) and those at end-exhalation were 0.0 {+-} 3.1 mm (range, -7.0 to 5.3 mm), -1.2 {+-} 3.9 mm (range, -11.2 to 6.7 mm), and 0.1 {+-} 3.2 mm (range, -9.9 to 5.1 mm) in the LR, AP, and SI directions, respectively. The SDs of the interfractional positional variation in the LR and SI directions were significantly larger at end-inhalation than at end-exhalation (LR, p < 0.001; SI, p < 0.001). Conclusions: The ranges of respiratory motion during the course of treatment and the interfractional positional variation were not negligible. The interfractional positional reproducibility was higher at end-exhalation than at end-inhalation under free breathing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Moving Toward Focal Therapy in Prostate Cancer: Dual-Isotope Permanent Seed Implants as a Possible Solution

Purpose: To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Methods and Materials: Nine plans, using {sup 125}I, {sup 103}Pd, and {sup 131}Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTV{sub i}) were delineated along with PTV (prostate + 5 mm), rectum, and urethra. Single-isotope implants, prescribed to conventional doses, were generated to achieve good PTV coverage. The PTV{sub i} were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. Results: The EUBED of PTV{sub i} in the setting of primary {sup 125}I implant increased 20-66% when {sup 103}Pd and {sup 131}Cs were used compared with {sup 125}I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTV{sub i} (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. Conclusions: This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experience-Based Quality Control of Clinical Intensity-Modulated Radiotherapy Planning

Purpose: To incorporate a quality control tool, according to previous planning experience and patient-specific anatomic information, into the intensity-modulated radiotherapy (IMRT) plan generation process and to determine whether the tool improved treatment plan quality. Methods and Materials: A retrospective study of 42 IMRT plans demonstrated a correlation between the fraction of organs at risk (OARs) overlapping the planning target volume and the mean dose. This yielded a model, predicted dose = prescription dose (0.2 + 0.8 [1 - exp(-3 overlapping planning target volume/volume of OAR)]), that predicted the achievable mean doses according to the planning target volume overlap/volume of OAR and the prescription dose. The model was incorporated into the planning process by way of a user-executable script that reported the predicted dose for any OAR. The script was introduced to clinicians engaged in IMRT planning and deployed thereafter. The script's effect was evaluated by tracking {delta} = (mean dose-predicted dose)/predicted dose, the fraction by which the mean dose exceeded the model. Results: All OARs under investigation (rectum and bladder in prostate cancer; parotid glands, esophagus, and larynx in head-and-neck cancer) exhibited both smaller {delta} and reduced variability after script implementation. These effects were substantial for the parotid glands, for which the previous {delta} = 0.28 {+-} 0.24 was reduced to {delta} = 0.13 {+-} 0.10. The clinical relevance was most evident in the subset of cases in which the parotid glands were potentially salvageable (predicted dose <30 Gy). Before script implementation, an average of 30.1 Gy was delivered to the salvageable cases, with an average predicted dose of 20.3 Gy. After implementation, an average of 18.7 Gy was delivered to salvageable cases, with an average predicted dose of 17.2 Gy. In the prostate cases, the rectum model excess was reduced from {delta} = 0.28 {+-} 0.20 to {delta} = 0.07 {+-} 0.15. On surveying dosimetrists at the end of the study, most reported that the script both improved their IMRT planning (8 of 10) and increased their efficiency (6 of 10). Conclusions: This tool proved successful in increasing normal tissue sparing and reducing interclinician variability, providing effective quality control of the IMRT plan development process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of {alpha}/{beta} for Late Rectal Toxicity Based on RTOG 94-06

Purpose: To estimate {alpha}/{beta}, the parameter ratio from the linear-quadratic (LQ) model, for Grade {>=}2 late rectal toxicity among patients treated on Radiation Therapy Oncology Group (RTOG) protocol 94-06; and to determine whether correcting the rectal dose-volume histogram (DVH) for differences in dose per fraction, based on the LQ model, significantly improves the fit to these data of the Lyman-Kutcher-Burman (LKB) normal-tissue complication probability (NTCP) model. Methods and Materials: The generalized LKB model was fitted to the Grade {>=}2 late rectal toxicity data in two ways: by using DVHs representing physical dose to rectum, and by using a modified approach in which dose bins in the rectal DVH were corrected for differences in dose per fraction using the LQ model, with {alpha}/{beta} estimated as an additional unknown parameter. The analysis included only patients treated with the same treatment plan throughout radiotherapy, so that the dose per fraction to each voxel of rectum could be determined from the DVH. The likelihood ratio test was used to assess whether the fit of the LQ-corrected model was significantly better than the fit of the LKB model based on physical doses to rectum. Results: The analysis included 509 of the 1,084 patients enrolled on RTOG 94-06. The estimate of {alpha}/{beta} from the LQ-corrected LKB model was 4.8 Gy, with 68% confidence interval 0.6 Gy to 46 Gy. The fit was not significantly different from the fit of the LKB model based on physical dose to rectum (p = 0.236). Conclusions: The estimated fractionation sensitivity for Grade {>=}2 late rectal toxicity is consistent with values of {alpha}/{beta} for rectum found previously in human beings and in rodents. However, the confidence interval is large, and there is no evidence that LQ correction of the rectal DVH significantly changes the fit or predictions of the LKB model for this endpoint.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Preoperative Radiotherapy on General and Disease-Specific Health Status of Rectal Cancer Survivors: A Population-Based Study

Purpose: To date, few studies have evaluated the impact of preoperative radiotherapy (pRT) on long-term health status of rectal cancer survivors. Using a population-based sample, we assessed the impact of pRT on general and disease-specific health status of rectal cancer survivors up to 10 years postdiagnosis. The health status of older ({>=}75 years old at diagnosis) pRT survivors was also compared with that of younger survivors. Methods and Materials: Survivors identified from the Eindhoven Cancer Registry treated with surgery only (SU) or with pRT between 1998 and 2007 were included. Survivors completed the Short Form-36 (SF-36) health survey questionnaire and the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Colorectal 38 (EORTC QLQ-CR38) questionnaire. The SF-36 and EORTC QLQ-CR38 (sexuality subscale) scores of the survivors were compared to an age- and sex-matched Dutch normal population. Results: A total of 340 survivors (response, 85%; pRT survivors, 71%) were analyzed. Overall, survivors had similar general health status. Both short-term (<5 years) and long-term ({>=}5 years) pRT survivors had significantly poorer body image and more problems with gastrointestinal function, male sexual dysfunction, and defecation than SU survivors. Survivors had comparable general health status but greater sexual dysfunction than the normal population. Older pRT survivors had general and disease-specific health status comparable to that of younger pRT survivors. Conclusions: For better survivorship care, rectal cancer survivors could benefit from increased clinical and psychological focus on the possible long-term morbidity of treatment and its effects on health status.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Study of Epidermal Growth Factor Receptor Tyrosine Kinase Inhibitors Concurrent With Individualized Radiotherapy for Patients With Locally Advanced or Metastatic Non-Small-Cell Lung Cancer

Purpose: To establish the safety profile and efficacy of epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs) concurrent with individualized radiotherapy (RT) in patients with locally advanced or metastatic non-small-cell lung cancer (NSCLC). Patients and Methods: Between June 2007 and January 2010, 26 patients with Stage III/IV NSCLC were enrolled in this prospective study. These patients were treated with EGFR-TKIs (gefitinib 250 mg or erlotinib 150 mg, oral daily) concurrent with individualized RT with curative intent. The thoracic RT plans were individually designed on the basis of tumor size and normal tissue volume constraints. All patients were assessed for toxicity, and 25 patients were available for efficacy. The primary endpoints were acute toxicity, overall survival, and median survival time. The secondary endpoints included local control rate, time to tumor progression, and progression-free survival (PFS). Results: Median gross tumor volume, mean lung dose, and lung V20 were 56 cm{sup 3}, 8.6 Gy, and 14%, respectively. Median thoracic radiation dose was 70 Gy at a margin of gross tumor volume (range, 42-82 Gy), and median biological equivalent dose was 105 Gy (range, 60-119 Gy). Acute skin, hematologic, esophageal, and pulmonary toxicities were acceptable and manageable. Severe adverse events included neutropenia (Grade 4, 4%) and thrombocytopenia (Grade 4, 8%), esophagitis (Grade 3, 4%), and pneumonitis (Grade 3, 4%). With a median follow-up of 10.2 months, a local control rate of 96% was achieved for thoracic tumor. Median time to progression, median PFS, and median survival time were 6.3, 10.2, and 21.8 months, respectively. The 1- and 2-year PFS rates were both 42%, and 1-, 2-, and 3-year overall survival rates were 57%, 45%, and 30%, respectively. Conclusion: Concurrent EGFR-TKIs with individualized RT shows a favorable safety profile and promising outcome, therefore serving as a therapeutic option for patients with locally advanced or metastatic NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Abdominal {gamma}-Radiation Induces an Accumulation of Function-Impaired Regulatory T Cells in the Small Intestine

Purpose: To assess the frequency and the functional characteristics of one major component of immune tolerance, the CD4{sup +}FoxP3{sup +} regulatory T cells (Tregs) in a mouse model of abdominal irradiation. Methods and Materials: Mice were exposed to a single abdominal dose of {gamma}-radiation (10 Gy). We evaluated small intestine Treg infiltration by Foxp3 immunostaining and the functional suppressive activity of Tregs isolated from mesenteric lymph nodes. Results: Foxp3 immunostaining showed that radiation induced a long-term infiltration of the intestine by Tregs (levels 5.5 times greater than in controls). Co-culture of Tregs from mesenteric lymph nodes with CD4{sup +} effector cells showed that the Tregs had lost their suppressive function. This loss was associated with a significant decrease in the levels of Foxp3, TGF-{beta}, and CTLA-4 mRNA, all required for optimal Treg function. At Day 90 after irradiation, Tregs regained their suppressive activity as forkhead box P3 (Foxp3), transforming growth factor beta (TGF-{beta}), and cytotoxic T-lymphocyte antigen 4 (CTLA-4) expression returned to normal. Analysis of the secretory function of mesenteric lymph node Tregs, activated in vitro with anti-CD3/anti-CD28 Abs, showed that this dysfunction was independent of a defect in interleukin-10 secretion. Conclusion: Radiation caused a long-term accumulation of function-impaired Foxp3{sup +}CD4{sup +} Tregs in the intestine. Our study provides new insights into how radiation affects the immune tolerance in peripheral tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗