Search NASA⌕ Search

SEARCH · Search NASA

Results for “Direct current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Effects of hydrogen partial pressure on crack initiation and growth rate in vintage X52 steel

There is an increasing interest in ensuring compatibility of existing natural gas infrastructure with conveyance of hydrogen, especially for vintage (pre-1970s) pipeline steels. While hydrogen is known to affect the fatigue and fracture resistance of these materials, there is a lack of data on its effects on crack initiation at low hydrogen partial pressure. To address this gap, the current work presents a series of fatigue tests on vintage API Grade X52 steel in pure nitrogen, air and gaseous hydrogen at partial pressures of 1 and 207 bar. Circumferential notch tension (CNT) specimens with direct current potential difference (DCPD) measurements are used to get S–N curves for crack initiation and failure, and compact tension (CT) tests to assess crack growth rates. Results indicate that air accelerates crack initiation, low hydrogen partial pressure affects the crack growth rate, and higher pressures have the largest impact on both. Surprisingly, crack initiation is faster in air than at 1 bar hydrogen partial pressure. The CNT tests also reveal that the orientation of the banded microstructure has no effect on the crack initiation site, but it influences its growth behavior. Moreover, fractography shows that hydrogen also promotes instances of quasi-cleavage and intergranular fracture, linked to embrittlement of the material. Here, these results demonstrate that, while hydrogen may impact the entirety of the fatigue process, its effects on the early stages of damage accumulation become relevant only at larger pressures. More comprehensive studies of crack initiation in hydrogen atmospheres will be critical to future codes and standards for hydrogen infrastructure.

Circumferential notch tension↗

Public electric vehicle charging station utilization in the United States

The utilization of electric vehicle (EV) charging equipment is a key driver of charging station economics, but current trends and factors related to the utilization of public charging infrastructure in the United States are not well understood. This study analyzes EV charging data from 3,705 nationwide public Level 2 (L2) and direct current fast charging (DCFC) stations over 2.5 years (2019-2022), observing utilization patterns over time. Regression analysis is used to assess the relationships between station utilization and several contextual and environmental factors. We conclude that local EV adoption is a strong indicator of utilization; L2 station utilization decreases with the size of the local charging network, while DCFC stations are less affected; and increased charging power has a greater effect on utilization for DCFC stations than L2. This study fills a critical research gap by reporting updated public charging station utilization statistics and analysis for the U.S. market.

33 ADVANCED PROPULSION SYSTEMS↗

Fault Current Control and Protection in a Standalone DC Microgrid Using Adaptive Droop and Current Derivative

This report presents a novel fault detection, characterization, and fault current control algorithm for a standalone solar-photovoltaic (PV) based dc microgrids. The protection scheme is based on the current derivative algorithm. The overcurrent and current directional/differential comparison based protection schemes are incorporated for the dc microgrid fault characterization. For a low impedance fault, the fault current is controlled based on the current/voltage thresholds and current direction. Generally, the droop method is used to control the power-sharing between the converters by controlling the reference voltage. In this article, an adaptive droop scheme is also proposed to control the fault current by calculating a virtual resistance R droop , and to control the converter output reference voltage. For a high impedance fault, differential comparison method is used to characterize the fault. These algorithms effectively control the converter pulsewidth and reduce the flow of source current from a particular converter, which helps to increase the fault clearing time. Additionally, a trip signal is sent to the corresponding dc circuit breaker (DCCB), to isolate the faulted converter, feeder or a dc bus. The dc microgrid protection design procedure is detailed, and the performance of the proposed method is verified by simulation analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computer model for estimating electrochemical cell kinetic performance

The effective rates or "kinetics" of electrochemical reactions at electrode surfaces is an abiding area of interest for diagnostic analysis of new materials in energy storage devices such as lithium-ion cells. It is generally understood that kinetic limitations can dominate performance during power pulses and stem from interfacial impedance sources. Yet, kinetic limitations are poorly understood in contemporary electrochemical energy storage devices, and antiquated modeling techniques are often incorrectly applied to lithium-ion cell systems, for example, the classical Butler-Volmer (BV) expression. The referenced invention provides an advanced modeling technique of exceptional accuracy that allows diagnostic analysis of kinetic parameters over current, temperature, device aging, and pulse time domains. This invention represents an advanced approach that accounts for the effects of surface availability and thermodynamic constraints on kinetic rates, based on common cell data (e.g., direct-current (DC) pulse analysis under constant-current conditions). The model yields highly accurate predictions of voltage drop for a given device at arbitrary conditions. This capability satisfies a clear need for knowledge regarding mechanistic constraints of electrochemical energy storage devices under arbitrary conditions, and can be integrated into diagnostic software embedded into device applications. The methodology allows diagnostic analysis to be performed, providing key quantities central to understanding kinetic limitations in electrochemical devices, such as the (1) exchange current density, (2) the effective electrode surface availability, (3) the thermodynamic interfacial energy barrier, (4) as well as various overpotential and impedance terms dealing with the intrinsic charge transfer, mass-transport limitations, ohmic contributions, and total impedance, all given as a function of temperature, pulse time, and cell aging. The present form of CellSage-Kinetics is programmable FORTRAN code, a form that supports theoretical/mathematical development activities and single-user applications. A GUI-based software version could be released if requested under a license agreement.

Gering, KevinL.↗

Refueling Infrastructure Deployment in Low-Income and Non-Urban Communities

The U.S. National Blueprint for Transportation Decarbonization identifies the need to invest in infrastructure supporting low- and zero-emission vehicles, especially in low-income and overburdened communities, to eliminate nearly all greenhouse gas emissions from the transportation sector by 2050. The alternative fuel vehicle refueling property tax credit (26 U.S. Code § 30C) includes eligibility criteria intended to encourage investment in underserved communities based on the economic characteristics or urban character of the census tract in which the fueling infrastructure is installed. Eligible census tracts are those that qualify for the New Markets Tax Credit or that are not located within urban areas as defined by the U.S. Census Bureau. This study quantifies how many fueling-related amenities are currently located in census tracts that qualify and do not qualify for the 30C tax credit based on IRS Notice 2024-20. For existing electric vehicle charging stations, 51% of Level 2 and 60% of Direct Current Fast Charging public stations are located in eligible census tracts. 73% of natural gas, propane, and hydrogen fueling stations are in qualifying census tracts and 75% of biodiesel and renewable fuel stations are in qualifying census tracts. This compares with 73% of existing gas stations in eligible census tracts. For deploying the refueling infrastructure to satisfy future demand, this study shows that truck stops (94%), commercial truck stops (92%), and Federal Highway alternative fuel corridors (89%) are predominantly located in eligible locations. Additionally, significant percentages of the population (62%), light-duty vehicle registrations (64%), and medium- and heavy-duty vehicle registrations (68%) fall within eligible areas.

33 ADVANCED PROPULSION SYSTEMS↗

Sputter deposition of Ta 1 W 1 Au 1 Bi 7 films for next generation hohlraums

Hohlraum simulation predicts a higher x-ray drive from Ta 1 W 1 Au 1 Bi 7 compared with our current Au hohlraum. Here, we study the effect of deposition process parameters including deposition rate, working pressure, target-to-substrate distance, substrate bias, and substrate temperature on the microstructure of Ta1W1Au1Bi7 films deposited by direct current magnetron sputtering onto planar substrates. We found that the substrate temperature has a pronounced effect on the film microstructure. This is attributed to the Bi low melting point (271°C) causing its adatom mobility to be strongly dependent on the substrate temperature. Additionally, we observed phase separation for films deposited with a high substrate bias. These results have important implications for the development of a robust Ta 1 W 1 Au 1 Bi 7 hohlraum fabrication process.

36 MATERIALS SCIENCE↗

Fundamental-Frequency Reactive Circulating Current Injection for Capacitor Voltage Balancing in Hybrid-MMC HVDC Systems During Riding Through PTG Faults

Here, this article presents a comprehensive analysis and a novel solution for the discharge problem on the half-bridge submodules' (HBSMs') capacitors in the hybrid modular multilevel converter (MMC)-based high-voltage direct current transmission systems under a long-term (e.g., several minutes or longer) pole-to-ground fault condition. The mechanism of this issue is analyzed, and then a solution based on fundamental-frequency reactive circulating current (FFRCC) injection is proposed. The influence of FFRCC injection is analyzed in terms of the fluctuated arm capacitor energy and the current stress of semiconductors. Moreover, an enhanced arm voltage modulation method based on HBSMs and full-bridge submodules coordinate control is proposed to accelerate the capacitor voltage balance of HBSMs. Finally, the performance of the proposed control strategy is verified by the simulation results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Port of New York and New Jersey Drayage Electrification Analysis

The National Renewable Energy Laboratory (NREL) evaluated the potential for drayage electrification in the Port of New York and New Jersey (PoNYNJ), with a focus on operators: Harbor Freight Transport (HF), Safeway Trucking (SWT), and International Motor Freight Inc (IMF). This report summarizes the data collection and electrification evaluation of all three drayage operators, includes detailed operational data, and identifies the performance requirements for battery electric tractors (BETs) and corresponding infrastructure operated within the context of PoNYNJ drayage operation. This report also details a methodology to evaluate opportunities, strategies, and challenges associated with future expansions of BETs in meeting PANYNJ emissions goals. The Port Authority has established a goal of achieving Net Zero carbon emissions by 2050 across all facilities, including from tenant and stakeholder sources such as drayage trucks. NREL used real-world performance data collected on the three PoNYNJ drayage operations, along with modeling and analysis tools to compare BET to diesel trucks. From March to July 2021, NREL collected 1Hz vehicle and engine data from 46 drayage trucks at the three operators totaling nearly 121,000 miles of operation, providing enough information to assess vehicle operations for electrification potential. A Future Automotive Systems Technology Simulator (FASTSim) electric truck powertrain model was validated using PoNYNJ data and scenarios were run to evaluate drayage truck electrification requirements over the real-world cycles. The first scenario examined BET viability with minimal changes to existing operations. This assumes the trucks charge when stopped for two hours or longer, have a functional battery size of 375 kWh, and can charge at 270 kilowatts (kW) average which are the specification of the commercially available Freightliner eCascadia. The second scenario looked at what operational, charging infrastructure, and BET technology changes would be needed to fully electrify. Finally, detailed analysis was run on charging rate structure to understand operational costs to the fleets. The studied drayage trucks averaged 5.1 MPG, spent roughly 9% of their energy at idle, and drove an average of 140 miles per day with a maximum daily distance of 573 miles. The FASTSim model results indicate a comparable BET would use 417 kWh of energy per day on average accounting for cargo weight, which is close to the full usable capacity of the eCascadia currently available on the market. Based on the daily average operating data, partial fleet electrification is possible with current technology. However, some specific days of operation would require over 1,600 kWh of energy due to longer distances traveled by the trucks and more intense operation. Trucks used for long distance and intense operation cannot be readily electrified with current technology without operational changes. Full adoption of BETs could reduce CO 2 emissions from these fleets by roughly 75% today, eliminating 76 metric tons of CO 2 (MTCO 2 ) per vehicle each year, which equates to 24,100 MTCO 2 per year for all three operators. Commercially available direct current fast chargers (DCFC) have charge rates up to 350 kW. Based on the average daily modeled energy use for each operator, current industrial rate structures, and the assumption of 350 kW peak charging, full drayage electrification would increase electricity consumption. In addition, peak demand usage would increase with unmanaged charging along with cost of electricity having a direct impact on cost per mile for electric vehicles. The resulting cost per mile for BETs along with comparable cost per mile for conventional diesel trucks are also examined at $\$$4.00 per gallon of diesel. It will be important for PANYNJ and the drayage operators within the PoNYNJ to consider these load impacts to their existing electrical infrastructure and devise operational strategies that avoid coincident charging of vehicles to mitigate demand charges. Despite these electricity cost increases, savings from reductions in diesel consumption will help offset the costs of this increased electricity consumption. However, prices of both electricity and diesel are subject to change based on various factors meaning the realized savings will vary over time. This shows BETs could be cost-competitive on an energy cost per mile basis for all scenarios while diesel is above $\$$3.00/gal. Further, if diesel prices dropped to the 15-year low of $2.33/gal, it would still be cost competitive to operate the EVs with electricity costs of 16.3 ¢/kWh or less.

33 ADVANCED PROPULSION SYSTEMS↗

Three-dimensional modelling of a self-sustained atmospheric pressure glow discharge

The atmospheric pressure glow discharge (APGD) is a relatively simple and versatile plasma source used in diverse applications. Stable APGD operation at high currents, generally a challenge due to instabilities leading to glow-to-arc transition, has been demonstrated using actively-controlled cathodic cooling. This article presents the computational modelling and simulation of a self-sustained direct-current APGD in helium within a 10 mm pin-to-plate inter-electrode gap for currents ranging from 4 to 40 mA. The APGD model is comprised of the conservation equations for total mass, chemical species, momentum, thermal energy of heavy-species and of free electrons, and electric charge. The model equations are discretized using a nonlinear variational multi-scale finite element method that has demonstrated superior accuracy in other plasma flow problems, on a temporal and three-dimensional computational domain suitable to unveil the potential occurrence of instabilities. Modelling results show good agreement with experimental measurements of voltage drop and the same trend but higher values of temperature. The higher temperatures obtained by the simulations appear to be due to the absence of a near-cathode heat dissipation model. Here, the results also reveal that the distribution of electron density and of the ratio of atomic helium ions to total ions transitions from monotonically increasing away from the cathode to presenting a minimum near the centre of the gap with increasing current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fault Location Using the Natural Frequency of Oscillation of Current Discharge in MTdc Networks

This paper discusses a novel offline-fault location approach using single ended measurements. The natural dissipation of the circuit parameters are considered for fault location. A relationship between the damped natural frequency of oscillation of the transmission line current and fault location is established. The hybrid dc circuit breaker (dcCB) interrupts the fault current, whereby the transmission line current attenuates under the absence of any driving voltage source. The line capacitance discharges into the fault at a specific frequency of oscillation and rate of attenuation. Utilizing this information, the fault location in a multi-terminal direct current (MTdc) network can be obtained. A three terminal radial model of a MTdc is used for performance evaluation of the proposed method using Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

42 ENGINEERING↗

Safeguards Challenges and Safeguards Technology Needs Assessment for Leading Thorium Fuel Cycles

Several thorium fuel cycle variants are currently being actively pursued by the global nuclear energy community. These variants have short-, medium-, and long-term deployment pathways in a variety of reactor types, including thorium-fueled molten salt reactors. Those pathways in turn give rise to a variety of fuel designs, fuel cycle facilities, and nuclear material processing requirements. These emerging fuel cycles will impact the technical implementation of safeguards, and they already raise questions about the applicability of current verification technologies. To address this issue, research is being performed to produce a detailed safeguards technology road map. It will include a needs assessment of the detection research and development (R&D;) necessary to transition the current safeguards technology toolkit to meet the verification needs of thorium fuel cycles, and to formulate the scientific basis for building new instrumentation to fill any potential capability gaps. The purpose of this technology road map is to define and inform on the safeguards technology needs for thorium fuel cycles, reflecting only the leading candidate thorium fuel cycles prioritized based on implementation timescales and the current direction of international programs. This work provides a guide to the priorities for future directed R&D; needed to bring the technology readiness levels (TRLs) of safeguards detection solutions in line with the higher TRLs of the most promising thorium fuel cycles. Herein, a summary is presented of thorium fuel cycle options and activities currently under way worldwide, which provides the technical basis for the needs evaluation. The key synergies and differences between these fuel cycles and current conventional uranium- and plutonium-based fuel cycles will be discussed from a nuclear material accountancy and detection standpoint. Reactor inventory calculations, fuel cycle simulations, and conclusions from the safeguards technology needs assessment will be presented, together with plans for experimental validation.

Worrall, Louise G.↗

Multi-Port Autonomous Reconfigurable Solar Power Plant

As the penetration level of power electronics increases and remote photovoltaic (PV) generation is integrated into the alternating current (ac) grid, the short-circuit ratio (SCR) at the point of interconnection of a hybrid PV–energy storage system (ESS) plant may be low. Additionally, the inertia of the alternating current (ac) grid may be low. The low SCRs and inertias can lead to reliability challenges in the power grid. These operating conditions require additional reinforcements, such as synchronous condensers, static var compensators, static synchronous compensators, and high-voltage direct current (HVdc) links/grids. HVdc links or grids may also provide the additional capability of connecting the plant to asynchronous grids and/or connecting asynchronous grids, among others. This scenario leads to discrete development of solar inverters, energy storage inverters, HVdc converters, and several transformers. Some of the problems associated with this discrete development and inverter-based generation include increased cost, lower reliability, and reduced efficiency associated with duplication of power electronics (PEs); competing controls of several individual discrete inverter-based generators due to the presence of multiple PEs, which leads to derating of the system; and transient stability problems arising from inverter-based generation, such as voltage/frequency events leading inverter shutdowns, voltage instability and control interactions in the formed weak grid, and harmonics caused by resonances of multiple inverters.

14 SOLAR ENERGY↗

Electrochemical formation of hydroxide for enhancing carbon dioxide and acid gas uptake by a solution

A system is described for forming metal hydroxide from a metal carbonate utilizing a water electrolysis cell having an acid-producing anode and a hydroxyl-producing cathode immersed in a water solution of sufficient ionic content to allow an electric current to pass between the hydroxyl-producing cathode and the acid-producing anode. A metal carbonate, in particular water-insoluble calcium carbonate or magnesium carbonate, is placed in close proximity to the acid-producing anode. A direct current electrical voltage is provided across the acid-producing anode and the hydroxyl-producing cathode sufficient to generate acid at the acid-producing anode and hydroxyl ions at the hydroxyl-producing cathode. The acid dissolves at least part of the metal carbonate into metal and carbonate ions allowing the metal ions to travel toward the hydroxyl-producing cathode and to combine with the hydroxyl ions to form the metal hydroxide. The carbonate ions travel toward the acid-producing anode and form carbonic acid and/or water and carbon dioxide. Among other uses, the metal hydroxide formed can be employed to absorb acid gases such as carbon dioxide from a gas mixture. The invention can also generate hydrogen and oxidative gases such as oxygen or chlorine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct/Alternating Current Electrochemical Method for Removing and Recovering Heavy Metal from Water Using Graphene Oxide Electrode

Treatment of heavy-metal pollution in both point-of-use water and industrial wastewater is critical in protecting human health and the environment. Current methods for heavy-metal treatment in both sources have limitations. For point-of-use water, current methods usually suffer from limited capacity and difficulties in spontaneously removing multiple heavy metals. For industrial wastewater, current methods greatly reduce the value of heavy metal by precipitating them as sludge which requires further treatment. Here we developed an electrochemical method that can treat both low-concentration and high-concentration heavy-metal pollution using either direct current (DC) or alternating current (AC) electrodeposition with graphene-oxide-modified carbon felt electrode (CF-GO). The graphene oxide provides a high density of surface functional groups to assist the electrodeposition. The electrodeposition method showed 2 orders of magnitude higher capacity (>29 g heavy metal for 1 g of graphene oxide) compared with traditional adsorption methods. For low levels of heavy-metal pollution in point-of-use water, DC electrodeposition with a CF-GO electrode can reduce single heavy-metal ion pollution (Cu, Cd, and Pb) as well as multiple ion mixtures to below safe water drinking levels. This method can tolerate a much wider range of heavy-metal pollution in point-of-use water than traditional adsorption methods. For high-level pollution in industrial wastewater, AC electrodeposition can recover >99.9% heavy-metal ions. Finally, by tuning the AC frequency and voltage, the electrodeposition method can further selectively recover Cu, Cd, and Pb separately, which adds values to the heavy-metal removal process.

36 MATERIALS SCIENCE↗

Microscopic vertical orientation of nano-interspaced graphene architectures in deposit films as electrodes for enhanced supercapacitor performance

This paper reported a novel two-step process to fabricate high-performance supercapacitor films that contain microscale domains of nano-interspaced, re-stacked graphene sheets oriented perpendicular to the surface of current collector substrate, i.e., carbon fiber paper. In the two-step process, we first used ligand molecules to modify the surface of graphene oxide (GO) sheets and manipulate the interspacing between the re-stacked GO sheets. The ligand-modified GOs, i.e., m-GOs, were then reduced to obtain more conductive graphene (m-rGO), where X-ray diffraction measurement results indicated well-controlled interlayer spacing between the restacked m-rGO sheets up to 1 nm. The typical lateral dimension of the restacked m-rGO sheets were ~40 µm. Then, electrical field was introduced during m-rGO slurry deposition process to induce the vertical orientation of the m-rGO sheets/stacks in the film deposit. The direct current electrical field induced the orientation of the domains of m-rGO stacks along the direction perpendicular to the surface of deposit film, i.e., direction of electric field. Also, the applied electric field increased the interlayer spacing further, which should enhance the diffusion and accessibility of electrolyte ions. As compared with the traditionally deposited “control” films, the field-processed film deposits that contain oriented structure of graphene sheets/stacks have shown up to ~1.6 times higher values in capacitance (430 F/g at 0.5 A/g) and ~67% reduction in equivalent series resistance. Finally, the approach of using electric field to tailor the microscopic architecture of graphene-based deposit films is effective to fabricate film electrodes for high performance supercapacitors.

36 MATERIALS SCIENCE↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

The impact of Hall physics on magnetized high energy density plasma jets

Hall physics is often neglected in high energy density plasma jets due to the relatively high electron density of such jets (n{sub e} ∼ 10{sup 19} cm{sup −3}). However, the vacuum region surrounding the jet has much lower densities and is dominated by Hall electric field. This electric field redirects plasma flows towards or away from the axis, depending on the radial current direction. A resulting change in the jet density has been observed experimentally. Furthermore, if an axial field is applied on the jet, the Hall effect is enhanced and ignoring it leads to serious discrepancies between experimental results and numerical simulations. By combining high currents (∼1 MA) and magnetic field helicity (15° angle) in a pulsed power generator such as COBRA, plasma jets can be magnetized with a 10 T axial field. The resulting field enhances the impact of the Hall effect by altering the density profile of current-free plasma jets and the stability of current-carrying plasma jets (e.g., Z-pinches)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring the alignment of carbon nanotubes dispersed in a liquid crystal matrix using coplanar electrodes

We report on the use of a liquid crystalline host medium to align single-walled carbon nanotubes in an electric field using an in-plane electrode configuration. Electron microscopy reveals that the nanotubes orient in the field with a resulting increase in the DC conductivity in the field direction. Current versus voltage measurements on the composite show a nonlinear behavior, which was modelled by using single-carrier space-charge injection. The possibility of manipulating the conductivity pathways in the same sample by applying the electrical field in different (in-plane) directions has also been demonstrated. Raman spectroscopy indicates that there is an interaction between the nanotubes and the host liquid crystal molecules that goes beyond that of simple physical mixing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗