Quasi-Static Time-Series Test Feeder for PV Integration Analysis on Distribution Systems
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
This paper summarizes the three-year technical activities of the IEEE Task Force (TF) on behind-the-meter (BTM) distributed energy resources (DERs): estimation, uncertainty quantification, and control. The potential grid services from BTM DERs are discussed in detail. The paper also reviews the state-of-the-art for BTM DERs visibility, uncertainty quantification, and, optimization and control. Furthermore, different aspects of the market structures associated with BTM DERs are covered, including emerging market and business models. Finally, needs and recommendations are provided for additional areas such as system protection, computing capabilities, algorithm development, market structure design, cyberinfrastructure and security, and hardware and software developments.
We propose to continue the development of the restoration algorithms and the tool’s user interface, both of which have been developed under the GMLC-0131 project. This project aims to develop a distribution restoration decision support tool that will assist utilities in performing distribution restoration after extreme weather events in an optimal and efficient manner. The tool will integrate the weather information/forecasts and system fragility assessment together with the field measurement data to improve the situational awareness and estimate the system damage status. Advanced optimization models will be leveraged to dispatch repair crews and associated resources. New resources (e.g., automatic switches and distributed generators (DGs)) enabled by distribution automation and smart grid development will be utilized to reconfigure distribution grids and pick up loads promptly to reduce the outage sizes and durations. The closed-loop feature of the tool will make the tool adaptive to the evolving weather events and varying restoration capabilities. In this CRADA, we will collaborate with S&C Electric Company (S&C) to refine ANL-1060 (07/17/2019) the restoration algorithms that can be potentially applicable for any utility systems and vendor products, including: 1) Customizable information from both utility users and vendor users; 2) User interface design.
Not Available
Explore the source record for details and available documents.
Not Available
During a major outage in a secondary network distribution system, distributed generators (DGs) connected to the primary feeders as well as the secondary network can be used to serve critical loads. This paper proposed a resilience-oriented method to determine restoration strategies for secondary network distribution systems after a major disaster. Technical issues associated with the restoration process are analyzed, including the operation of network protectors, inrush currents caused by the energization of network transformers, synchronization of DGs to the network, and circulating currents among DGs. A look-ahead load restoration framework is proposed, incorporating technical issues associated with secondary networks, limits on DG capacity and generation resources, dynamic constraints, and operational limits. The entire outage duration is divided into a sequence of periods. Restoration strategies can be adjusted at the beginning of each period using the latest information. Numerical simulation of the modified IEEE 342-node low voltage networked test system is performed to validate the effectiveness of the proposed method.
Explore the source record for details and available documents.
The broad purpose of this project was to work cooperatively with the DOE to explore technology nad policy issues associated with more efficient, reliable, and affordable electric transmission and distribution use.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
High penetration from volatile renewable energy resources in the grid and the varying nature of loads raise the need for frequent line switching to ensure the efficient operation of electrical distribution networks. Operators must ensure maximum load delivery, reduced losses, and the operation between voltage limits. However, computations to decide the optimal feeder configuration are often computationally expensive and intractable, making it unfavorable for real-time operations. This is mainly due to the existence of binary variables in the network reconfiguration optimization problem. To tackle this issue, we have devised an approach that leverages machine learning techniques to reshape distribution networks featuring multiple substations. This involves predicting the substation responsible for serving each part of the network. Hence, it leaves simple and more tractable Optimal Power Flow problems to be solved. This method can produce accurate results in a significantly faster time, as demonstrated using the IEEE 37-bus distribution feeder. Compared to the traditional optimization-based approaches, a feasible solution is achieved approximately ten times faster for all the tested scenarios.
As modern power grids tend towards greater levels of automation and communication, the challenges of identifying and mitigating vulnerabilities to cyber-attacks are ones that are increasingly demanding attention. Today’s power system has evolved to form the foundational bedrock of modern society, and an attack on this infrastructure could prove disastrous. In this project we were tasked to investigate the use of distribution synchrophasors as an independent isolated sensor network with which we can corroborate, or flag potentially spoofed,Supervisory Control And Data Acquisition (SCADA) data. We adapted an approach to marry the underlying physical properties of power systems with the network communications used by power systems in order to offer insights unattainable by either data stream isolation. While the concept of intrusion detection systems (IDS) is well understood for monitoring network traffic and traditional IT computing systems, the approach discussed in this report is motivated by several key notions: first, current SCADA communications alone presents an incomplete view of the grid. Second, the power grid, and the equipment controlling it, is grounded by laws of physics. Given this, we leverage high-frequency physical grid measurements to understand the physical condition of the grid, and combine this with SCADA. While high-frequency physical grid measurements and SCADA communication over Internet Protocol (IP) networks are fundamentally disparate information sources, when collectively examined through appropriate lenses, they offer a much more nuanced depiction of the grid.
This paper proposes a solution for maintaining power balance within all three phases at residential level during islanded mode of operation. Grid abnormalities can lead to isolating the residential microgrid from the main grid, and as a result, distributed generation (DG) units take the full responsibility of supplying local loads. However, in such condition, some phases might face the challenge of meeting local load demand due to the lack of enough power generation, resulting in voltage drop and frequency variation across household loads. In order to resolve this issue, the proposed method in this paper seamlessly interconnects all three single-phase feeders during islanded mode and forms a unified single-phase residential microgrid. Consequently, the load demands in all three phases are met, leading to enhanced voltage and frequency profiles. For this purpose, a seamless transition algorithm is defined which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid accordingly during transitions. Case study results are provided to verify the validity of proposed method.
Not Available
Not Available
The growth of inverter-based resources (IBRs) in modern power systems can challenge system stability since they do not natively provide inertia, prompting a need to develop new methods to address the potential instabilities. In this paper, a dynamically configurable grid-forming (GFM) and grid-following (GFL) control is proposed, which enables inverters to flexibly transition to support system needs. The operation mode transition between GFM and GFL controls is adopted as an additional degree of control flexibility to adjust the small-signal stability margin. In addition, a holistic and detailed small-signal model for a distribution feeder that captures the dynamics from both synchronous generators (SGs) and IBRs is also derived and used to evaluate the effectiveness of the proposed GFM/GFL controls to augment the system small-signal stability margin. Case studies with varying levels of IBRs were implemented in MATLAB/Simulink to demonstrate the effectiveness of the proposed approach.