Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The Dose That Works: Low Level Laser Treatment of Tendinopathy

Background: Low Level Laser Therapy (LLLT) is used in the treatment of tendon injuries. However, the clinical effectiveness of this modality remains controversial with limited agreement on the most efficacious dosage and parameter choices. Purpose: To assess the clinical effectiveness of LLLT in the treatment of tendinopathy and the validity of current dosage recommendations for treatment. Method: Medical databases were searched from inception to 1st August 2008. Controlled clinical trials evaluating LLLT as a primary intervention for any tendinopathy were included in the review. Methodological quality was classified using the PEDro scale. Appropriateness of treatment parameters were assessed using established guidelines. Results: Twenty five trials met the inclusion criteria. There was conflicting findings from multiple trials: 12 showed positive effects and 13 were inconclusive or showed no effect. Dosages used in the 12 positive studies support the existence of an effective dosage window that closely resembled current guidelines. Where pooling of data was possible, LLLT showed a positive effect size; in high quality studies of lateral epicondylitis, participants' grip strength was 9.59 Kg higher than the control group; for participants with Achilles tendinopathy, the effect was 13.6 mm less pain on a 100 mm visual analogue scale. Conclusion: This study found conflicting evidence as to the effectiveness of LLLT in the treatment of tendinopathy. However, an effective dosage window emerged showing benefit in the treatment of tendinopathy. Strong evidence exists from the 12 positive studies that positive outcomes are associated with the use of current dosage recommendations for the treatment of tendinopathy.

60 APPLIED LIFE SCIENCES↗

New linear stability parameter to describe low-β electromagnetic microinstabilities driven by passing electrons in axisymmetric toroidal geometry

In magnetic confinement fusion devices, the ratio of the plasma pressure to the magnetic field energy, β, can become sufficiently large that electromagnetic microinstabilities become unstable, driving turbulence that distorts or reconnects the equilibrium magnetic field. In this paper, a theory is proposed for electromagnetic, electron-driven linear instabilities that have current layers localised to mode-rational surfaces and binormal wavelengths comparable to the ion gyroradius. The model retains axisymmetric toroidal geometry with arbitrary shaping, and consists of orbit-averaged equations for the mode-rational surface layer, with a ballooning space kinetic matching condition for passing electrons. The matching condition connects the current layer to the large scale electromagnetic fluctuations, and is derived in the limit that β is comparable to the square root of the electron-to-ion-mass ratio. Electromagnetic fluctuations only enter through the matching condition, allowing for the identification of an effective β that includes the effects of equilibrium flux surface shaping. The scaling predictions made by the asymptotic theory are tested with comparisons to results from linear simulations of micro-tearing and electrostatic microinstabilities in MAST discharge #6252, showing excellent agreement. In particular, it is demonstrated that the effective β can explain the dependence of the local micro-tearing mode (MTM) growth rate on the ballooning parameter θ 0 – possibly providing a route to optimise local flux surfaces for reduced MTM-driven transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Image quality indicator and dechromator setup for static LANSCE proton radiography experiment

This document describes a static geometry consisting of a sphere of gold and Ti-6Al-4V alloy, along with an energy-loss matching dechromator composed of polycarbonate, to field with the X3 electromagnetic magnifying lens at LANSCE during the next beam cycle. This static configuration will allow us to: (1) characterize the system’s resolution at the material interface between the gold and titanium alloy, and test the image quality for fine features associated with the screws used to fasten the titanium alloy hemispheres; (2) tune our models of proton scattering and imaging for these materials; and (3) test a procedure to align the polycarbonate dechromator and the sphere within the proton beamline. The data will also be suitable for validation of the software options available for proton radiography simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical Study of the Single Electron Optical Stochastic Cooling Experiment at the IOTA Facility (Final Technical Report)

The objectives of this proposal were to explore fundamental aspects of radiation from individual and small groups of electrons in the optical stochastic cooling experiment conducted at Fermi National Laboratory's IOTA facility. Professor Swapan Chattopadhyay collaborated directly with the IOTA team on their initial experimental endeavors. Concurrently, a team from Berkeley, including Prof. Wurtele, Dr. Charman, and Dr. Greggory Penn from LBNL, and Prof. Chattapadhyay, pursued a theoretical exploration to identify potential subsequent experiments for IOTA. A wide range of possible experiments were considered, but they do not allow for tests for new quantum mechanical phenomena at the precision level of the current IOTA apparatus. However, the experimentally observed optical stochastic cooling of a single electron in IOTA validated the relevance of the classical electromagnetic field nature of the continuous electron-radiation interaction (as opposed to discrete instantaneous photon emissions and associated 'classical particle trajectory jumps') responsible for cooling and pointed towards innovative methods of experimental techniques to measure 'turn-by-turn' field correlations. Such measurements have the promise of bridging the transition from classical fields building up to discrete quantum transitions and enhance proper theoretical understanding.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The TE Wave Transmission Method for Electron Cloud Measurements at Cesr-TA

We report on the optimization of TE Wave measurements at the Cesr-TA ring at Cornell University. The CESR storage ring is currently used as a test bed for technologies to be used in the damping rings of the International Linear Collider. The TE Wave measurement method utilizes capacitive buttons (BPMs) in the ring to excite and detect a propagating electromagnetic wave corresponding to the beampipe's fundamental TE mode. The presence of low-energy electrons along the wave path changes its propagation characteristics, which can be detected by analyzing the received signal. By choosing the machine fill pattern (gaps and bunch trains length) it is possible to modulate the density of the electron cloud and derive information on its rise and fall times by observing the detected signal spectrum. The possibility of circulating both electron and positron beams in the ring enabled us to separate the contribution of primary photoelectrons, which are independent on the circulating particle nature, from the transverse resonant mechanism, which can increase the primary electron density many times over and which only takes place with a circulating positron beam.

43 PARTICLE ACCELERATORS↗

Fracture Diagnostics Using Low Frequency Electromagnetic Induction and Electrically Conductive Proppants

The monitoring and diagnostics of induced fractures are important for the real-time performance evaluation of hydraulic fracturing operations. Previous electromagnetic (EM) based studies show that single backbone tri-axial induction logging tools are promising candidates for real-time monitoring and diagnosis of fractures in open-hole wells. To support the development of field deployable tools, the concept must be tested in experiments, in a controllable environment, before it is tested under field-like conditions. To this end, we have developed numerical tools which can simulate any wellbore environment while logging hydraulic fractures with the induction tool. We have designed and built a prototype induction tool and performed two sets of tests to compare with numerical simulation results. The computational and experimental setup consists of tri-axial transmitter- and receiver-coils in co-axial, co-planar and cross-polarized configurations. Both lab and shallow earth measurements are shown to be in good agreement with simulations for all examined cases. The average relative and maximum discrepancies of the measured signals from the simulated ones were lower than 3% and 10%, respectively. With the prototype tool, strong signals sensitive to the fracture’s surface area and dip-angle were measured in co-axial coil configuration, while weaker signals sensitive to the fracture’s aspect ratio were observed in the co-planar configuration. Cross-polarized signals are also shown to be strong and sensitive to the fracture’s dip. Lastly, we resolved the detectable components of the signal tensor to obtain parameters of simplified fracture geometries. The inversion algorithm, a derivative free directional search model, uses an objective function defined as a combination of co-axial and cross-polarized signals from different tool spacings to provide a well behaved global minimum. The robustness of inversion algorithm is tested on synthetic data for single cluster fractures in homogeneous and heterogeneous background electrical conductivity. All the effective model parameters for different cases, fracture conductivity (width), propped area (length) and dip-angle, are shown to be recovered with sufficient accuracy. We also evaluated the effect of multiple neighboring fractures and suggested a multi-cluster inversion algorithm that can accurately recover the proppant distribution in each fracture. Based on these results we provide a downhole tool design, with detailed specifications, that can effectively recover far-field proppant distribution in hydraulic fractures.

02 PETROLEUM↗

Can explicit suggestions about the harmfulness of EMF exposure exacerbate a nocebo response in healthy controls?

Highlights: • Results do not support a relationship between radiofrequency exposure and symptoms. • Healthy participants exhibited a nocebo response during believed radiofrequency exposure. • Awareness and belief are crucial in the presentation of symptoms. • The nocebo response may be exacerbated by alarmist media reports. While there has been consistent evidence that symptoms reported by individuals who suffer from Idiopathic Environmental Intolerance attributed to Electromagnetic Fields (IEI-EMF) are not caused by EMF and are more closely associated with a nocebo effect, whether this response is specific to IEI-EMF sufferers and what triggers it, remains unclear. The present experiment tested whether perceived EMF exposure could elicit symptoms in healthy participants, and whether viewing an ‘alarmist’ video could exacerbate a nocebo response. Participants were randomly assigned to watch either an alarmist (N = 22) or control video (N = 22) before completing a series of sham and active radiofrequency (RF) EMF exposure provocation trials (2 open-label, followed by 12 randomized, double-blind, counterbalanced trials). Pre- and post-video state anxiety and risk perception, as well as belief of exposure and symptom ratings during the open-label and double-blind provocation trials, were assessed. Symptoms were higher in the open-label RF-ON than RF-OFF trial (p < .001). No difference in either symptoms (p = .183) or belief of exposure (p = .144) was observed in the double-blind trials. Participants who viewed the alarmist video had a significant increase in symptoms (p = .041), state anxiety (p < .01) and risk perception (p < .001) relative to the control group. These results reveal the crucial role of awareness and belief in the presentation of symptoms during perceived exposure to EMF, showing that healthy participants exhibit a nocebo response, and that alarmist media reports emphasizing adverse effects of EMF also contribute to a nocebo response.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Analysis of the impact of parallel magnetic fluctuations on linear gyrokinetic stability in NSTX-U and verification of gyro-fluid models

In this work, we use the CGYRO gyrokinetic code to analyze two L- and one H-mode discharges from the National Spherical Torus Experiment (NSTX) and NSTX-Upgrade (NSTX-U) selected due to their different mix of ion-scale driftwaves, ion temperature gradient (ITG) mode and trapped electron mode (TEM), and electromagnetic instabilities, kinetic ballooning mode (KBM), and micro-tearing mode (MTM) in the plasma core. It is found that the effect of parallel magnetic fluctuations is strongly destabilizing to the unstable KBMs compared to calculations with only perpendicular magnetic fluctuations. Two discharges have a mix of ITG/TEM and MTMs that are predicted to be dominant instability across the plasma radius. The parallel magnetic fluctuations are found to have little effect on the MTM stability but are destabilizing to ITG/TEM modes. To test the validity of the gyro-fluid linear stability codes TGLF and GFS at low aspect ratio, a database of linear growth rates has been created using the CGYRO gyrokinetic code. The database is comprised of various parameter scans around a standardized set of NSTX-U core parameters. It contains a group of electrostatic cases and an electromagnetic group that includes the effects of perpendicular and parallel magnetic fluctuations. Comparing the results from the GFS and TGLF models, we find that GFS exhibits the best agreement with the database of CGYRO linear growth rates. Comparing the model results for the electromagnetic scans shows that GFS captures the effects of parallel magnetic fluctuations accurately, while the TGLF model does not, as it lacks sufficient perpendicular energy resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New electromagnetic particle simulation code for the analysis of spacecraft-plasma interactions

A novel particle simulation code, the electromagnetic spacecraft environment simulator (EMSES), has been developed for the self-consistent analysis of spacecraft-plasma interactions on the full electromagnetic (EM) basis. EMSES includes several boundary treatments carefully coded for both longitudinal and transverse electric fields to satisfy perfect conductive surface conditions. For the longitudinal component, the following are considered: (1) the surface charge accumulation caused by impinging or emitted particles and (2) the surface charge redistribution, such that the surface becomes an equipotential. For item (1), a special treatment has been adopted for the current density calculated around the spacecraft surface, so that the charge accumulation occurs exactly on the surface. As a result, (1) is realized automatically in the updates of the charge density and the electric field through the current density. Item (2) is achieved by applying the capacity matrix method. Meanwhile, the transverse electric field is simply set to zero for components defined inside and tangential to the spacecraft surfaces. This paper also presents the validation of EMSES by performing test simulations for spacecraft charging and peculiar EM wave modes in a plasma sheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ensuring electromagnetic compatibility in grid-connected power converters: Challenges, standards, and compliance strategies

In today's rapidly advancing world, electronic devices and systems are fundamental to a wide range of industries, including renewable energy and global telecommunications infrastructure. However, as these devices become more complex and widespread, the risk of electromagnetic interference (EMI) also increases, underscoring the importance of stringent Electromagnetic Compatibility (EMC) requirements for maintaining system integrity. This paper addresses the specific challenges associated with grid-connected power converters (GCPCs), which are critical in integrating renewable energy into existing power grids. It explores the complexities of EMI in the context of GCPCs, particularly given the recent emergence of tailored EMC standards for these systems. The paper also highlights the shortcomings of applying generic or unrelated standards to GCPCs, often leading to inadequate compliance and testing protocols. Through a detailed analysis of existing standards and recent advancements in product-specific EMC requirements, this paper provides a comprehensive overview of the current landscape, offering guidance to stakeholders on navigating the intricate EMC compliance landscape, with a focus on methodologies, testing procedures, and the evolving regulatory environment for GCPCs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

IMPROVING SENSITIVITY TO WEAK PULSATIONS WITH PHOTON PROBABILITY WEIGHTING

All {gamma}-ray telescopes suffer from source confusion due to their inability to focus incident high-energy radiation, and the resulting background contamination can obscure the periodic emission from faint pulsars. In the context of the Fermi Large Area Telescope, we outline enhanced statistical tests for pulsation in which each photon is weighted by its probability to have originated from the candidate pulsar. The probabilities are calculated using the instrument response function and a full spectral model, enabling powerful background rejection. With Monte Carlo methods, we demonstrate that the new tests increase the sensitivity to pulsars by more than 50% under a wide range of conditions. This improvement may appreciably increase the completeness of the sample of radio-loud {gamma}-ray pulsars. Finally, we derive the asymptotic null distribution for the H-test, expanding its domain of validity to arbitrarily complex light curves.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmological electromagnetic fields and dark energy

We show that the presence of a temporal electromagnetic field on cosmological scales generates an effective cosmological constant which can account for the accelerated expansion of the universe. Primordial electromagnetic quantum fluctuations produced during electroweak scale inflation could naturally explain the presence of this field and also the measured value of the dark energy density. The behavior of the electromagnetic field on cosmological scales is found to differ from the well studied short-distance behavior and, in fact, the presence of a non-vanishing cosmological constant could be signalling the breakdown of gauge invariance on cosmological scales. The theory is compatible with all the local gravity tests, and is free from classical or quantum instabilities. Thus we see that, not only the true nature of dark energy can be established without resorting to new physics, but also the value of the cosmological constant finds a natural explanation in the context of standard inflationary cosmology. This mechanism could be discriminated from a true cosmological constant by upcoming observations of CMB anisotropies and large scale structure.

79 ASTRONOMY AND ASTROPHYSICS↗

An experimental program with high duty-cycle polarized and unpolarized positron beams at Jefferson Lab

Positron beams, both polarized and unpolarized, are identified as important ingredients for the experimental programs at the next generation of lepton accelerators. In the context of the hadronic physics program at Jefferson Lab (JLab), positron beams are complementary, even essential, tools for a precise understanding of the electromagnetic structure of nucleons and nuclei, in both the elastic and deep-inelastic regimes. For instance, elastic scattering of polarized and unpolarized electrons and positrons from the nucleon enables a model independent determination of its electromagnetic form factors. Also, the deeply-virtual scattering of polarized and unpolarized electrons and positrons allows unambiguous separation of the different contributions to the cross section of the lepto-production of photons and of lepton-pairs, enabling an accurate determination of the nucleons and nuclei generalized parton distributions, and providing an access to the gravitational form factors of the energy-momentum tensor. Furthermore, positron beams offer the possibility of alternative tests of the Standard Model of particle physics through the search of a dark photon, the precise measurement of electroweak couplings, and the investigation of charged lepton flavor violation. This document discusses the perspectives of an experimental program with high duty-cycle positron beams at JLab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First beam tests of prototype silicon modules for the CMS High Granularity Endcap Calorimeter

The High Luminosity phase of the Large Hadron Collider will deliver 10 times more integrated luminosity than the existing collider, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry. As part of its upgrade program, the Compact Muon Solenoid collaboration is designing a high-granularity calorimeter (HGCAL) to replace the existing endcap calorimeters. It will feature unprecedented transverse and longitudinal readout and triggering segmentation for both electromagnetic and hadronic sections. The electromagnetic section and a large fraction of the hadronic section will be based on hexagonal silicon sensors of 0.5–1 cm 2 cell size, with the remainder of the hadronic section being based on highly-segmented scintillators with silicon photomultiplier readout. The intrinsic high-precision timing capabilities of the silicon sensors will add an extra dimension to event reconstruction, especially in terms of pileup rejection. First hexagonal silicon modules, using the existing Skiroc2 front-end ASIC developed for CALICE, have been tested in beams at Fermilab and CERN in 2016. Here, we present results from these tests, in terms of system stability, calibration with minimum-ionizing particles and resolution (energy, position and timing) for electrons, and the comparisons of these quantities with GEANT4-based simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of vacuum fluctuation suppression on atomic decay rates

Highlights: > Excited atoms are shot through a cavity containing an electromagnetic field. > Cavity is in the lowest mode in a non-classical state. > Such a state can suppress the decay rate of the atoms in certain situations. > We show that this effect can be correlated with periods of negative energy density. - Abstract: The use of atomic decay rates as a probe of sub-vacuum phenomena will be studied. Because electromagnetic vacuum fluctuations are essential for radiative decay of excited atomic states, decay rates can serve as a measure of the suppression of vacuum fluctuations in non-classical states, such as squeezed vacua. In such states, the renormalized expectation value of the square of the electric field or the energy density can be periodically negative, representing suppression of vacuum fluctuations. We explore the extent to which atomic decays can be used to measure the mean squared electric field or energy density. We consider a scheme in which atoms in an excited state transit a closed cavity whose lowest mode contains photons in a non-classical state. A crucial feature of our analysis is that we do not employ the rotating wave approximation. The change in the decay probability of the atom in the cavity due to the non-classical state can, under certain circumstances, serve as a measure of the mean squared electric field or energy density in the cavity. We make some estimates of the magnitude of this effect, which indicate that an experimental test might be possible, although very challenging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulsed thrust measurements using electromagnetic calibration techniques

A thrust stand for accurately measuring impulse bits, which ranged from 10-1000 {mu}N s using a noncontact electromagnetic calibration technique is described. In particular, a permanent magnet structure was designed to produce a uniform magnetic field, and a multiturn coil was made to produce a calibration force less than 10 mN. The electromagnetic calibration force for pulsed thrust measurements was linear to the coil current and changed less than 2.5% when the distance between the coil and magnet changed 6 mm. A pulsed plasma thruster was first tested on the thrust stand, and afterward five single impulse bits were measured to give a 310 {mu}N s average impulse bit. Uncertainty of the measured impulse bit was analyzed to evaluate the quality of the measurement and was found to be 10 {mu}N s with 95% credibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of absorber coupled TES polarimeter at millimeter wavelengths.

We report an absorber coupled TES bolometric polarimeter, consisting of an absorptive metal grid and a Mo/Au bi-layer TES on a suspended silicon nitride membrane disk. The electromagnetic design of the polarization sensitive absorbers, the heat transport modeling of the detector, the thermal response of the TES, and the micro-fabrication processes are presented. We also report the results of laboratory tests of a single pixel prototype detector, and compare with theoretical expectations.

47 OTHER INSTRUMENTATION↗

Streaming readout for next generation electron scattering experiments

Current and future experiments at the high-intensity frontier are expected to produce an enormous amount of data that needs to be collected and stored for offline analysis. Thanks to the continuous progress in computing and networking technology, it is now possible to replace the standard ‘triggered’ data acquisition systems with a new, simplified and outperforming scheme. ‘Streaming readout’ (SRO) DAQ aims to replace the hardware-based trigger with a much more powerful and flexible software-based one, that considers the whole detector information for efficient real-time data tagging and selection. Considering the crucial role of DAQ in an experiment, validation with on-field tests is required to demonstrate SRO performance. In this paper, we report results of the on-beam validation of the Jefferson Lab SRO framework. In this work, we exposed different detectors (PbWO-based electromagnetic calorimeters and a plastic scintillator hodoscope) to the Hall-D electron-positron secondary beam and to the Hall-B production electron beam, with increasingly complex experimental conditions. By comparing the data collected with the SRO system against the traditional DAQ, we demonstrate that the SRO performs as expected. Furthermore, we provide evidence of its superiority in implementing sophisticated AI-supported algorithms for real-time data analysis and reconstruction.

47 OTHER INSTRUMENTATION↗