Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow injection analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Effect of the neutral beam injector operational regime on the Alfven eigenmode saturation phase in DIII-D plasma

The aim of this study is to analyze the effect of the neutral beam injector (NBI) operation regime on the saturation phase of the Alfven Eigenmodes (AEs) in DIII-D plasma. Here, the analysis is done using the linear and nonlinear versions of the gyro-fluid code FAR3d. A set of parametric analyses are performed modifying the nonlinear simulation EP $β$ (NBI injection power), EP energy (NBI voltage) and the radial location of the EP density profile gradient (NBI radial deposition). The analysis indicates a transition from the soft (local plasma relaxation) to the hard MHD (global plasma relaxation) limit if the simulation EP $β$ $\unicode{x2A7E}$ $0.02$, leading to bursting MHD activity caused by radial AEs overlapping. MHD bursts cause an enhancement of the EP transport showing ballistic-like features as avalanche-like events. Simulations in the soft MHD limit show an increment of the EP density gradient as the EP $β$ increases. On the other hand, there is a gradient upper limit in the hard MHD limit, consistent with the critical-gradient behavior. AEs induce shear flows and zonal current leading to the deformation of the flux surfaces and the safety factor profile, respectively, particularly strong for the simulation in the hard MHD limit. Simulations in the hard MHD regime show a decrease of the AE frequency in the saturation phase; this is caused by the destabilization of a transitional mode between a $9/3-10/3$ TAE and a $9/3$ RSAE that may explain the AE frequency down-sweeping observed in some DIII-D discharges. Reducing the EP energy in the nonlinear simulations leads to a weakening of the plasma perturbation. On the other hand, increasing the EP energy causes the opposite effect. Nonlinear simulations of off-axis NBI profiles indicate a lower plasma perturbation as the EP density gradient is located further away from the magnetic axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

STE thrust chamber technology: Main injector technology program and nozzle Advanced Development Program (ADP)

The purpose of the STME Main Injector Program was to enhance the technology base for the large-scale main injector-combustor system of oxygen-hydrogen booster engines in the areas of combustion efficiency, chamber heating rates, and combustion stability. The initial task of the Main Injector Program, focused on analysis and theoretical predictions using existing models, was complemented by the design, fabrication, and test at MSFC of a subscale calorimetric, 40,000-pound thrust class, axisymmetric thrust chamber operating at approximately 2,250 psi and a 7:1 expansion ratio. Test results were used to further define combustion stability bounds, combustion efficiency, and heating rates using a large injector scale similar to the Pratt & Whitney (P&W) STME main injector design configuration including the tangential entry swirl coaxial injection elements. The subscale combustion data was used to verify and refine analytical modeling simulation and extend the database range to guide the design of the large-scale system main injector. The subscale injector design incorporated fuel and oxidizer flow area control features which could be varied; this allowed testing of several design points so that the STME conditions could be bracketed. The subscale injector design also incorporated high-reliability and low-cost fabrication techniques such as a one-piece electrical discharged machined (EDMed) interpropellant plate. Both subscale and large-scale injectors incorporated outer row injector elements with scarfed tip features to allow evaluation of reduced heating rates to the combustion chamber.

Source record↗

[Quantification and monitoring of vascular resistance in the lower limbs by the Doppler method (animal model)]

The object of this study was to define and validate a non-invasive method of evaluation and monitoring of vascular resistances in the leg. Blood flow velocity was measured by Doppler ultrasound in an animal model (ewe) with similar blood flow characteristics in the lower limb as man and allowing access to the required invasive measurements for validation of the method (pressure and flow). Vascular resistances distal to the measuring point (femoral, for example) were assessed using the resistance index R = D/S, S being the peak systolic deflection and D that of diastolic reflux of the Doppler spectral analysis of flow in the femoral artery. The values and variations of this resistance index were compared with the vascular resistances calculated from measurements of pressure and flow at the point of Doppler sampling and expressed in mmHg/ml/min. Femoral flow was measured by Doppler ultrasound (Doppler-echo), and mean pressure by an arterial catheter introduced into the abdominal aorta. Compression of the lower limb veins induced a venous return resulting in a reduction of cardiac output and femoral flow. During compression, femoral flow decreased by an average of 29% (p < 0.001) although mean pressure and heart rate did not change significantly. The femoral resistance index (Rf) increased by an average of 37.5% (p < 0.01) and vascular resistances increased by 45.9% (p < 0.01). Injection of 1 mg adrenaline induced peripheral vasoconstriction with an increase in blood pressure and a decrease in heart rate and femoral flow.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

A numerical model for coupling between atomization and spray dynamics in liquid rocket thrust chambers

This paper describes a novel method of coupling the atomization and spray combustion processes encountered in coaxial injection elements of liquid rocket engine thrust chambers. This method is based on the Jet-Embedding technique in which the liquid jet core equations and the gas phase equations are solved separately. The liquid and gas phase solutions, however, are coupled through the boundary conditions at the interface between the phases. The computational grid for the gas phase calculations are adapted to the shape of the liquid jet core. The axial variation of droplet sizes are calculated using a stability analysis appropriate for the atomization regime of liquid jet breakup. The predictions of this method have been validated with experimental data on low speed water jets. Using this method, calculations are performed for the SSME fuel preburner single injector flow field. The results obtained are in good agreement with the predictions of the volume-of-fluid method.

Giridharan, M. G.↗

Effects of Adenovirus-Mediated Delivery of the Human Hepatocyte Growth Factor Gene in Experimental Radiation-Induced Heart Disease

Purpose: Irradiation to the heart may lead to late cardiovascular complications. The purpose of this study was to investigate whether adenovirus-mediated delivery of the human hepatocyte growth factor gene could reduce post-irradiation damage of the rat heart and improve heart function. Methods and Materials: Twenty rats received single-dose irradiation of 20 Gy gamma ray locally to the heart and were randomized into two groups. Two weeks after irradiation, these two groups of rats received Ad-HGF or mock adenovirus vector intramyocardial injection, respectively. Another 10 rats served as sham-irradiated controls. At post-irradiation Day 120, myocardial perfusion was tested by myocardial contrast echocardiography with contrast agent injected intravenously. At post-irradiation Day 180, cardiac function was assessed using the Langendorff technique with an isolated working heart model, after which heart samples were collected for histological evaluation. Results: Myocardial blood flow was significantly improved in HGF-treated animals as measured by myocardial contrast echocardiography at post-irradiation Day 120 . At post-irradiation Day 180, cardiac function was significantly improved in the HGF group compared with mock vector group, as measured by left ventricular peak systolic pressure (58.80 +- 9.01 vs. 41.94 +- 6.65 mm Hg, p < 0.05), the maximum dP/dt (5634 +- 1303 vs. 1667 +- 304 mm Hg/s, p < 0.01), and the minimum dP/dt (3477 +- 1084 vs. 1566 +- 499 mm Hg/s, p < 0.05). Picrosirius red staining analysis also revealed a significant reduction of fibrosis in the HGF group. Conclusion: Based on the study findings, hepatocyte growth factor gene transfer can attenuate radiation-induced cardiac injury and can preserve cardiac function.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Utah FORGE: Optimization of a Plug-and-Perf Stimulation (Fervo Energy)

Information around the plug-and-perf treatment design at Utah FORGE by Fervo Energy. Objective and Purpose: - Develop a multistage hydraulic stimulation approach designed specifically to target the top three factors that control the technical and commercial viability of an EGS system: i) Achieving sufficient injectivity to support high cross-well flow rates ii) Distributing flow evenly across the wellbore and reservoir to maximize heat mining efficiency, ensure sustained heat transfer, and mitigate thermal breakthrough iii) Overcoming the effects of stress heterogeneity, stress shadowing, and variations in natural fracture properties during the stimulation treatment, leading to a more predictable stimulated reservoir volume and offset well placement - The following activities will be performed: i) Design, plan, and execute a multistage plug-and-perf stimulation treatment at a Fervo site with data acquisition and well testing activities aimed at addressing key technical aspects of the issues above ii) Perform data processing and interpretation of field results to translate the results form the Fervo site to a site-specific design at the Utah FORGE site iii) Design, plan, and execute a multistage plug-and-perf stimulation treatment design at the Utah FORGE site Methods and Approach: - Design a detailed data acquisition plan to maximize learning around: i) DFIT testing ii) Petrophysical logging, image logging iii) Permanent DAS/DTS fiber optic monitoring iv) Deep borehole microseismic monitoring v) Shallow borehole induced seismicity monitoring vi) Injection/production testing (RTA analysis, tracer testing) vii) Integrated numerical modeling and production forecasting

15 GEOTHERMAL ENERGY↗

High Fidelity Computational Analysis of CO2 Trapping at Pore Scales (Final Technical Report)

With an alarming rise in carbon dioxide (CO2) emission from anthropogenic sources, CO2 sequestration has become an attractive choice to mitigate the emission. Some popular storage media for CO 2 are oil reservoirs, deep coal-bed, and deep oceanic-beds. These have been used for the long term CO 2 storage. Due to special lowering viscosity and surface tension property of CO 2 , it has been widely used for enhanced oil recovery. The sites for CO 2 sequestration or enhanced oil recovery mostly consist of porous rocks. Lack of knowledge of molecular mobility under confinement and molecule-surface interactions between CO2 and natural porous media results in generally governed by unpredictable absorption kinetics and total absorption capacity for injected fluids, and therefore, constitutes barriers to the deployment of this technology. Therefore, it is important to understand the flow dynamics of CO 2 through the porous microstructures at the finest scale (pore-scale) to accurately predict the storage potential and long-term dynamics of the sequestered CO 2 . This report discusses about pore-network flow modeling approach using variational method and analyzes simulated results this method simulations at pore-scales for idealized network and using Berea Sandstone CT scanned images. Variational method provides a promising way to study the kinetic behavior and storage potential at the pore scale in the presence of other phases. The current study validates variational solutions for single and two-phase Newtonian and single phase non-Newtonian flow through angular pores for special geometries whose analytical and/or empirical solutions are known. The hydraulic conductance for single phase flow through a triangular duct was also validated against empirical results derived from lubricant theory.

54 ENVIRONMENTAL SCIENCES↗

Shattered pellet injection simulations with NIMROD

Optimal strategies for disruption mitigation benefit from the understanding of details both spatially and temporally. Beyond the assessment of the efficacy of a particular proposed Disruption Mitigation System (DMS), ITER's longevity will require accounting of both mitigated and unmitigated disruptions. Accurate models and validated simulations that detail multiple ITER scenarios with mitigated and unmitigated disruptions are essential for accurate estimates of load damage. The primary candidate for ITER's DMS is Shattered Pellet Injection (SPI); its efficacy must be evaluated within the next several years. To perform critical time dependent 3-D nonlinear simulations, we have developed a particle based SPI model in the NIMROD code coupled to its modified single fluid equations with impurity and radiation [Izzo, Nucl. Fusion 46(5), 541 (2006)]. SPI validation simulations of the thermal quench and comparisons to DIII-D impurity scan experiments [Shiraki et al., Phys. Plasmas 23(6), 062516 (2016)] are presented. We also present an initial ITER Q = 10 pure neon SPI simulation and compare it with the DIII-D SPI simulations. NIMROD SPI simulations demonstrate that the ablating fragment drives strong parallel flows that transport the impurities and governs the thermal quench. Analysis of SPI simulations shows that the mixed deuterium/neon SPI results in a more benign thermal quench due to the enhanced transport caused by the additional deuterium. These results suggest that an optimal pellet mixture exists for the SPI system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of Power Distribution Models using Load Flow Analysis in an ADMS Environment

Electric utilities are facing the need for better monitoring, analysis, and control of their distribution systems. An accurate mathematical model is a key to both the development of cutting-edge, scalable model-based algorithms and the assessment of emerging technologies such as distributed energy resources (DER) for grid planning and operation. However, the constantly evolving nature of power distribution systems poses challenges to maintaining accurate models. In this paper, we propose a novel load flow based approach to validate power distribution models. Networked equipment models described according to the Common Information Model (CIM) standard and a measurement model are used to formulate the distribution load flow problem. First, a system admittance matrix (Ybus) is derived from device-level CIM parameters. Next, the operational parameters (dynamic Ybus and nodal injections) are extracted from the measurement model using sensor configuration and equipment state. An iterative power flow method is then used to compute nodal voltages and branch flows that are compared against the measurement data to find any inconsistencies in the networked equipment model. This approach is implemented within GridAPPS-D, an open-source standards-based platform for advanced distribution management system (ADMS) application development, and demonstrated on the IEEE 13-bus, 123-bus, and 8500-node test feeders.

Common information model, model validation, power ↗

TREATABILITY TEST REPORT FOR THE REMOVAL OF CHROMIUM FROM GROUNDWATER AT 100-D AREA USING ELECTROCOAGULATION

The U.S. Department of Energy (DOE) has committed to accelerate cleanup of contaminated groundwater along the Columbia River. The current treatment approach was driven by a series of Interim Action Records of Decision (IAROD) issued in the mid-1990s. Part of the approach for acceleration involves increasing the rate of groundwater extraction for the chromium plume north of the 100-D Reactor and injecting the treated water in strategic locations to hydraulically direct contaminated groundwater toward the extraction wells. The current treatment system uses ion exchange for Cr(VI) removal, with off-site regeneration of the ion exchange resins. Higher flow rates will increase the cost and frequency of ion exchange resin regeneration; therefore, alternative technologies are being considered for treatment at high flow rates. One of these technologies, electrocoagulation (EC), was evaluated through a pilot-scale treatability test. The primary purpose of the treatability study was to determine the effectiveness of Cr(VI) removal and the robustness/implementability of an EC system. Secondary purposes of the study were to gather information about derivative wastes and to obtain data applicable to scaling the process from the treatability scale to full-scale. The treatability study work plan identified a performance objective and four operational objectives. The performance objective for the treatability study was to determine the efficiency (effectiveness) of hexavalent chromium removal from the groundwater, with a desired concentration of {le} 20 micrograms per liter ({micro}g/L) Cr(VI) in the effluent prior to re-injection. Influent and effluent total chromium and hexavalent chromium data were collected using a field test kit for multiple samples per week, and from off-site laboratory analysis of samples collected approximately monthly. These data met all data quality requirements. Two of three effluent chromium samples analyzed in the off-site (that is, fixed) laboratory met the performance objective during the continuous operational testing. Effluent hexavalent chromium analyzed by the field laboratory met the performance goal in over 90 percent of the samples. All effluent hexavalent chromium samples during the batch testing with high influent hexavalent chromium concentrations ({approx}2000 {micro}g/L) met the performance objective. Although the EC system was able to meet the performance goal, it must be noted that it was not uncommon for the system to be operated in recycle mode to achieve the performance goal. The EC unit was sometimes, but not always, capable of a single pass treatment efficiency high enough to meet the performance goal, and recycling water for multiple treatment passes was effective. An operational objective was to determine the volume and composition of the waste streams to enable proper waste designation. The toxicity characteristic leaching procedure (TCLP) concentrations, pH, and free liquids were determined for solid material from the EC electrodes (mechanically removed scale), the filter press, and the tank bottoms for the effluent and waste collector tanks. These data met all data quality requirements. All solid-phase secondary waste streams were found to be below the TCLP limits for the toxicity characteristic, and a pH value within the limits for the corrosivity characteristic. Out of three samples, two (one of scale from the EC unit and one from filter press solids) failed the free liquid (paint filter) test, which is one of the acceptability criteria for Hanford's Environmental Restoration Disposal Facility (ERDF). The solid-phase waste generation rate was about 0.65-gallon of solid waste per 100 gallons of water treated. It is concluded that the solid-phase secondary waste generated from this technology under the conditions at the test site will meet the toxicity and corrosivity criteria for disposal. It is also concluded that with engineering and/or operational improvements, a solid-phase secondary waste could be produced that would meet the free liquid disposal requirements. The second operational objective was to assess the operational reliability and safety of the system. For the continuous operations testing period from July 23 to September 12,2007, the system was not able to operate unattended. An extensive period of startup and adjustment preceded continuous operations, but was unsuccessful in providing a suitable and robust operating condition. Primary operational reliability problems were related to the sensitivity of the solid separation process to operational conditions such that a robust operating procedure (for example, chemical dosage) was not identified during the treatability test. Poor solids separation and high effluent iron concentrations also led to operational difficulties associated with injection well fouling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Numerical and Experimental Study of Mixing Processes Associated with Hydrogen and High Hydrogen Content Fuels

As simulation capability improves exponentially with increasingly more cost effective CPUs and hardware, it can be used “routinely” for engineering applications. Many commercial products are available and they are marketed as increasingly powerful and easy to use. The question remains as to the overall accuracy of results obtained. To support the validation of the CFD, a hierarchical experiment was established in which the type of fuel injection (radial, axial) as well as level of swirl (non-swirling, swirling) could be systematically varied. The effort was limited to time efficient approaches (i.e., generally RANS approaches) although limited assessment of time resolved methods (i.e., unsteady RANS and LES) were considered. Careful measurements of the flowfield velocity and fuel concentration were made using both intrusive and non-intrusive methods. This database was then used as the basis for the assessment of the CFD approach. The numerical studies were carried out with a statistically based matrix. As a result, the effect of turbulence model, fuel type, axial plane, turbulent Schmidt number, and injection type could be studied using analysis of variance. The results for the non-swirling cases could be analyzed as planned, and demonstrate that turbulence model selection, turbulence Schmidt number, and the type of injection will strongly influence the agreement with measured values. Interestingly, the type of fuel used (either hydrogen or methane) has no influence on the accuracy of the simulations. For axial injection, the selection of proper turbulence Schmidt number is important, whereas for radial injection, the results are relatively insensitive to this parameter. In general, it was found that the nature of the flowfield influences the performance of the predictions. This result implies that it is difficult to establish a priori the “best” simulation approach to use. However, the insights from the relative orientation of the jet and flow do offer some guidance for which approach to take. Overall, the results underscore the importance of model “anchoring” (i.e., “tuning” the model to provide “reasonable” agreement with a well characterized geometry/flow). Finally, the results obtained have been carefully compiled into a standalone database following a standard format that is contained in an Appendix. This database is thus available for use by others for CFD modeling evaluations.

08 HYDROGEN↗

Dynamic modeling of injection-induced fault reactivation and ground motion and impact on surface structures and human perception

We summarize recent modeling studies of injection-induced fault reactivation, seismicity, and its potential impact on surface structures and nuisance to the local human population. We used coupled multiphase fluid flow and geomechanical numerical modeling, dynamic wave propagation modeling, seismology theories, and empirical vibration criteria from mining and construction industries. We first simulated injection-induced fault reactivation, including dynamic fault slip, seismic source, wave propagation, and ground vibrations. From co-seismic average shear displacement and rupture area, we determined the moment magnitude to about M w = 3 for an injection-induced fault reactivation at a depth of about 1000 m. We then analyzed the ground vibration results in terms of peak ground acceleration (PGA), peak ground velocity (PGV), and frequency content, with comparison to the U.S. Bureau of Mines’ vibration criteria for cosmetic damage to buildings, as well as human-perception vibration limits. For the considered synthetic M w = 3 event, our analysis showed that the short duration, high frequency ground motion may not cause any significant damage to surface structures, and would not cause, in this particular case, upward CO 2 leakage, but would certainly be felt by the local population.

58 GEOSCIENCES↗

Velocity and void distribution in a counter-current two-phase flow

Different flow regimes were investigated in a horizontal channel. Simulating a hot leg injection in case of a loss of coolant accident or flow conditions in reflux condenser mode, the hydraulic jump and partially reversed flow were identified as major constraints for a high amount of entrained water. Trying to simulate the reflux condenser mode, the test section now includes an inclined section connected to a horizontal channel. The channel is 90 mm high and 110 mm wide. Tests were carried out for water and air at ambient pressure and temperature. High speed video-metry was applied to obtain velocities from flow pattern maps of the rising and falling fluid. In the horizontal part of the channel with partially reversed flow the fluid velocities were measured by planar particle image velocimetry. To obtain reliable results for the gaseous phase, this analysis was extended by endoscope measurements. Additionally, a new method based on the optical refraction at the interface between air and water in a back-light was used to obtain time-averaged void fraction. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: Analysis of human plasma and cerebrospinal fluid

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

59 BASIC BIOLOGICAL SCIENCES↗

Microstructure and Properties of Thermally Sprayed Functionally Graded Coatings for Polymeric Substrates

The use of polymer matrix composites (PMCs) in the gas flow path of advanced turbine engines offers significant benefits for aircraft engine performance but their useful lifetime is limited by their poor erosion resistance. High velocity oxy-fuel (HVOF) sprayed polymer/cermet functionally graded (FGM) coatings are being investigated as a method to address this technology gap by providing erosion and oxidation protection to polymer matrix composites. The FGM coating structures are based on a polyimide matrix filled with varying volume fractions of WC-Co. The graded coating architecture was produced using a combination of internal and external feedstock injection, via two computer-controlled powder feeders and controlled substrate preheating. Porosity, coating thickness and volume fraction of the WC-Co filler retained in the coatings were determined using standard metallographic techniques and computer image analysis. The pull-off strength (often referred to as the adhesive strength) of the coatings was evaluated according to the ASTM D 4541 standard test method, which measured the greatest normal tensile force that the coating could withstand. Adhesive/cohesive strengths were determined for three different types of coating structures and compared based on the maximum indicated load and the surface area loaded. The nature and locus of the fractures were characterized according to the percent of adhesive and/or cohesive failure, and the tested interfaces and layers involved were analyzed by Scanning Electron Microscopy.

Ivosevic, M.↗

Analysis of film cooling in rocket nozzles

This report summarizes the findings on the NASA contract NAG8-212, Task No. 3. The overall project consists of three tasks, all of which have been successfully completed. In addition, some supporting supplemental work, not required by the contract, has been performed and is documented herein. Task 1 involved the modification of the wall functions in the code FDNS (Finite Difference Navier-Stokes) to use a Reynolds Analogy-based method. This task was completed in August, 1992. Task 2 involved the verification of the code against experimentally available data. The data chosen for comparison was from an experiment involving the injection of helium from a wall jet. Results obtained in completing this task also show the sensitivity of the FDNS code to unknown conditions at the injection slot. This task was completed in September, 1992. Task 3 required the computation of the flow of hot exhaust gases through the P&W 40K subscale nozzle. Computations were performed both with and without film coolant injection. This task was completed in July, 1993. The FDNS program tends to overpredict heat fluxes, but, with suitable modeling of backside cooling, may give reasonable wall temperature predictions. For film cooling in the P&W 40K calorimeter subscale nozzle, the average wall temperature is reduced from 1750R to about 1050R by the film cooling. The average wall heat flux is reduced by a factor of 3.

Woodbury, Keith A.↗

Chemical Tool Peer Review Summary.

Chemical tracers are commonly used to characterize fracture networks and to determine the connectivity between the injection and production wells. Currently, most tracer experiments involve injecting the tracer at the injection well, manually collecting liquid samples at the wellhead of the production well, and sending the samples off for laboratory analysis. While this method provides accurate tracer concentration data, it does not provide information regarding the location of the fractures conducting the tracer between wellbores. The goal of this project is to develop chemical sensors and design a prototype tool to help understand the fracture properties of a geothermal reservoir by monitoring tracer concentrations along the depth of the well. The sensors will be able to detect certain species of the ionic tracers (mainly iodide) and pH in-situ during the tracer experiment. The proposed high-temperature (HT) tool will house the chemical sensors as well as a standard logging sensor package of pressure, temperature, and flow sensors in order to provide additional information on the state of the geothermal reservoir. The sensors and the tool will be able to survive extended deployments at temperatures up to 225 °C and high pressures to provide real-time temporal and spatial feedback of tracer concentration. Data collected from this tool will allow for the real-time identification of the fractures conducting chemical tracers between wellbores along with the pH of the reservoir fluid at various depths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Simple and Sensitive LC-MS/MS Method for the Determination of Free 8-Hydroxy-2'-Deoxyguanosine in Human Urine

Urinary free 8-hydroxy-2'-deoxyguanosine (8OHdG), an oxidized product of DNA, and is frequently chosen as a biomarker of oxidative stress in humans, including studies of oxidative DNA damage during space flight. It is challenging to accurately and efficiently quantify urinary free 8OHdG in large scale human studies. LC-MS/MS is emerging as a preferable analytical technique owing its high sensitivity, selectivity and efficiency, compared to some traditional methods such as ELISA and HPLC. A simple and sensitive LC-MS/MS method has been developed for the determination of free 8OHdG in human urine. Sample preparation was done by solid phase extraction with a Waters Oasis HLB 96 well plate. A Waters Alliance 2795 HT Separation Module combined with a Quattro Micro tandem mass spectrometer was used as the LC-MS/MS system. The runtime of one injection can be less than 5 minutes using a reversed phase C18 column and an isocratic flow of methanol/water. ESI positive ions were quantified in the multiple reaction modes (MRM) using m/z 284 yields 168 for 8OHdG and m/z 289 yields173 for stable isotope labeled internal standard [(15)N5] 8OHdG. With this method for 8OHdG, a lower limit of quantitation of 1.0 nM (0.28 ng/mL) has been achieved using 100 microliter urine sample. The analytical range is between 1.0 and 100 nM with a correlation coefficient greater than or equal to 0.99. Good reproducibility can be obtained with intra-assay and inter-assay CVs less than or equal to 10% for 8OHdG spiked urine QC samples. This method can be used in high-throughput routine analysis of free 8OHdG in human urine.

Wang, Zuwei↗