Search NASA⌕ Search

SEARCH · Search NASA

Results for “Frequency extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Metagenomic Sequencing of an In Vitro-Simulated Microbial Community

Background: Microbial life dominates the earth, but many species are difficult or even impossible to study under laboratory conditions. Sequencing DNA directly from the environment, a technique commonly referred to as metagenomics, is an important tool for cataloging microbial life. This culture-independent approach involves collecting samples that include microbes in them, extracting DNA from the samples, and sequencing the DNA. A sample may contain many different microorganisms, macroorganisms, and even free-floating environmental DNA. A fundamental challenge in metagenomics has been estimating the abundance of organisms in a sample based on the frequency with which the organism's DNA was observed in reads generated via DNA sequencing. Methodology/Principal Findings: We created mixtures of ten microbial species for which genome sequences are known. Each mixture contained an equal number of cells of each species. We then extracted DNA from the mixtures, sequenced the DNA, and measured the frequency with which genomic regions from each organism was observed in the sequenced DNA. We found that the observed frequency of reads mapping to each organism did not reflect the equal numbers of cells that were known to be included in each mixture. The relative organism abundances varied significantly depending on the DNA extraction and sequencing protocol utilized. Conclusions/Significance: We describe a new data resource for measuring the accuracy of metagenomic binning methods, created by in vitro-simulation of a metagenomic community. Our in vitro simulation can be used to complement previous in silico benchmark studies. In constructing a synthetic community and sequencing its metagenome, we encountered several sources of observation bias that likely affect most metagenomic experiments to date and present challenges for comparative metagenomic studies. DNA preparation methods have a particularly profound effect in our study, implying that samples prepared with different protocols are not suitable for comparative metagenomics.

99 GENERAL AND MISCELLANEOUS↗

Fermilab PIP II machine protection system digitized data noise elimination scheme and its FPGA implementation

In Fermilab's PIP-II machine protection system, beam loss signals from various detectors are digitized at 125 MS/s. Noise from both high-frequency sources and low-frequency 60 Hz AC power equipment can contaminate the data. To suppress noise across these ranges especially 60 Hz and its harmonics, which overlap with beam loss signal frequencies advanced digital processing beyond standard filtering is required. Several real-time functional blocks were simulated and tested on an FPGA: (1) a dual time-constant discharging integrator filter, (2) a de-ripple baseline extraction and storage block, and (3) a fast-recovery discharging integrator. The nonlinear IIR integrator filter removes high-frequency noise and feeds into the baseline extractor. Upon detecting abrupt beam loss, it switches to a longer time constant to prevent baseline distortion. The de-ripple block calculates a valid baseline by averaging over multiple 60 Hz periods, storing results in a 4096-word FPGA RAM. This baseline is subtracted from raw data before integration by the fast-recovery block, which resets quickly after use. All blocks achieved expected performance.

Wu, J. [Fermilab] (ORCID:0000000344329521)↗

SISGR: Room Temperature Single-Molecule Detection and Imaging by Stimulated Emission Microscopy

Single-molecule spectroscopy has made considerable impact on many disciplines including chemistry, physics, and biology. To date, most single-molecule spectroscopy work is accomplished by detecting fluorescence. On the other hand, many naturally occurring chromophores, such as retinal, hemoglobin and cytochromes, do not have detectable fluorescence. There is an emerging need for single-molecule spectroscopy techniques that do not require fluorescence. In the last proposal period, we have successfully demonstrated stimulated emission microscopy, single molecule absorption, and stimulated Raman microscopy based on a high-frequency modulation transfer technique. These first-of-a- kind new spectroscopy/microscopy methods tremendously improved our ability to observe molecules that fluorescence weakly, even to the limit of single molecule detection for absorption measurement. All of these methods employ two laser beams: one (pump beam) excites a single molecule to a real or virtual excited state, and the other (probe beam) monitors the absorption/emission property of the single. We extract the intensity change of the probe beam with high sensitivity by implementing a high-frequency phase-sensitive detection scheme, which offers orders of magnitude improvement in detection sensitivity over direct absorption/emission measurement. However, single molecule detection based on fluorescence or absorption is fundamentally limited due to their broad spectral response. It is important to explore other avenues in single molecule detection and imaging which provides higher molecular specificity for studying a wide variety of heterogeneous chemical and biological systems. This proposal aimed to achieve single-molecule detection sensitivity with near resonance stimulated Raman scattering (SRS) microscopy. SRS microscopy was developed in our lab as a powerful technique for imaging heterogeneous samples based on their intrinsic vibrational contrasts, which provides much higher molecular specificity than absorption and fluorescence. Current sensitivity limit of SRS microscopy has not yet reached single molecule detection. We proposed to capitalize on our state-of-the-art SRS microscopy and develop near-resonance enhanced SRS for single molecule detection of carotenoids and heme proteins. The specific aims we pursued are: (1) building the next SRS generation microscope that utilizes near resonance enhancement to allow detection and imaging of single molecules with undetectable fluorescence, such as -carotene. (2) using near-resonance SRS as a contrast mechanism to study dye-sensitize semiconductor interface, elucidating the heterogeneous electron ejection kinetics with high spatial and temporal resolution. (3) studying the binding and unbinding of oxygen in single hemoglobin molecules in order to gain molecular level understanding of the long-standing issue of cooperativity. The new methods developed in the fund period of this grant have advanced the detection sensitivity in many aspects. Near-resonance SRS improved the signal by using shorter wavelengths for SRS microscopy. Frequency modulation and multi-color SRS target the reduction of background to improve the chemical specificity of SRS while maintaining the high imaging speed. Time-domain coherent Raman scattering microscopy targets to reduce the noise floor of coherent Raman microscopy. These methods have already demonstrated first-of-a-kind new applications in biology and medical research. However, we are still one order of magnitude away from single molecule limit. It is important to continue to improve the laser specification and develop new imaging methods to finally achieve label-free single molecule microscopy.

47 OTHER INSTRUMENTATION↗

Effect of time and spatial domains on monolayer 2D material interface thermal conductance measurement using ns ET-Raman

Raman-based approaches to characterizing thermal properties of nanoscale and microscale materials have proven to be powerful experimental methods. Here, this work explores the potential of energy-transport state-resolved Raman (ET-Raman) for the precise determination of interfacial thermal conductance (G) between monolayer 2D materials and their substrates. ET-Raman employs a continuous wave laser and nanosecond (ns) pulsed laser to induce both steady state and transient heating while simultaneously collecting 2D material temperature information from the Raman signal. A 3D numerical model built using the finite volume method simulates the two differentiated thermal transport processes. The simulated temperature rises are compared with experimental Raman temperature information to extract G. In this study, we investigate the temporal effects of the pulse frequency and pulse width of the ns laser on precise characterization of G. By running multiple simulations for a range of pulsed laser frequencies and pulse widths, we determine that ET-Raman is most sensitive to precise interfacial thermal conductance measurements with short pulse widths (~below 20 ns) and with pulsing frequencies that ensure sufficient cooling time between consecutive pulses (~below 500 kHz). We also conclude that substrate thickness and laser spot size play critical roles in heat distribution and subsequent sensitivity to meaningful G measurements. As both laser spot size and SiO 2 substrate thickness decrease, detection of interfacial thermal transport becomes more difficult. These results offer essential guidance in the design of future Raman-based approaches to thermal measurements using pulsed lasers.

2D materials↗

Coherence Spectroscopy in the Condensed Phase: Insights into Molecular Structure, Environment, and Interactions

The role of coherences, or coherently excited superposition states, in complex condensed-phase systems has been the topic of intense interest and debate for a number of years. In many cases, coherences have been utilized as spectators of ultrafast dynamics or for identifying couplings between electronic states. In rare cases, they have been found to drive excited state dynamics directly. Interestingly though, the utilization of coherences as a tool for high-detail vibronic spectroscopy has largely been overlooked until recently, despite their encoding of key information regarding molecular structure, electronically sensitive vibrational modes, and intermolecular interactions. Furthermore, their detection in the time domain makes for a highly comprehensive spectroscopic technique wherein the phase and dephasing times are extracted in addition to amplitude and intensity, an element not afforded in analogous frequency domain “steady-state” measurements. However, practical limitations arise in disentangling the large number of coherent signals typically accessed in broadband nonlinear spectroscopic experiments, often complicating assignment of the origin and type of coherences generated. Two-dimensional electronic spectroscopy (2DES) affords an avenue by which to disperse and decompose the large number of coherent signals generated in nonlinear experiments, facilitating the assignment of various types of quantum coherences. 2DES takes advantage of the broad bandwidth necessary for achieving the high time resolution desired for ultrafast dynamics and coherence generation by resolving the excitation axis to detect all excitation channels independently. This feature is beneficial for following population dynamics such as electronic energy transfer, and 2DES has become the choice method for such studies. Simultaneously, coherences arise as oscillations at well-defined coordinates across the 2D map often atop those evolving population signals. By isolating the coherent contribution to the 2DES data and Fourier transforming along the population time, a 3D spectral representation of the coherent 2D data is generated, and coherences are then ordered by their oscillation frequency, ν2. Individual coherences can then be selected by their frequency and evaluated via their distinct “2D coherence” spectra, yielding a significantly more distinctive set of spectroscopic signatures over other 1D methodologies and single-point 2DES analysis. Given that coherences of different origin result in unique 2D coherence spectra, these characteristics can be catalogued and compared directly against experiment for prompt assignment, a strategy not afforded by traditional 2DES analysis. In this Account, a structure-driven time-independent spectral model is discussed and employed to compare the 2D fingerprints of various coherences to experimental 2D coherence spectra. The frequency-domain approach can easily integrate ab initio derived vibronic parameters, and its correspondence with experimental coherence spectra of a model compound is demonstrated. Several examples and applications are discussed herein, from 2D Franck–Condon analysis of a model compound, to identifying the signatures of interpigment vibronic coupling in a photosynthetic light-harvesting complex. The 3D spectral approach to 2DES provides remarkable spectroscopic detail, in turn leading to new insights in molecular structure and interactions, which complement the time-resolved dynamics simultaneously recorded. The approach presented herein has the potential to distill down the convoluted set of nonlinear signals appearing in 2D coherent spectra, making the technique more amenable to high-detail vibronic spectroscopy in inherently complex condensed phase systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reactants, products, and transition states of elementary chemical reactions based on quantum chemistry

Reaction times, activation energies, branching ratios, yields, and many other quantitative attributes are important for precise organic syntheses and generating detailed reaction mechanisms. Often, it would be useful to be able to classify proposed reactions as fast or slow. However, quantitative chemical reaction data, especially for atom-mapped reactions, are difficult to find in existing databases. Therefore, we used automated potential energy surface exploration to generate 12,000 organic reactions involving H, C, N, and O atoms calculated at the ω B97X-D3/def2-TZVP quantum chemistry level. We report the results of geometry optimizations and frequency calculations for reactants, products, and transition states of all reactions. Additionally, we extracted atom-mapped reaction SMILES, activation energies, and enthalpies of reaction. We believe that this data will accelerate progress in automated methods for organic synthesis and reaction mechanism generation—for example, by enabling the development of novel machine learning models for quantitative reaction prediction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Collisional and Spectroscopic Studies of Exotic Atoms Using Ultra-Slow Antiprotons

Antiproton, the antiparticle of proton, is a unique projectile in the study of atomic collision physics, which can be treated theoretically either as a 'negative proton' or a 'heavy electron'. Atomic capture of an antiproton will result in formation of a highly excited exotic atom. Antiprotonic helium atom has been studied intensively by means of precision laser spectroscopy, which has led to a stringent determination of antiproton mass and charge to a level of ppb. Comparison of these values with those of proton gives one of the best tests of CPT invariance, the most fundamental symmetry in physics. However, the dynamic processes of antiproton capture remain unclarified, except for some indirect information given by those optical and X-ray observations. With an aim to produce an antiproton beam at atomic-physics energies for 'pure' collision experiments, we have so far developed techniques to decelerate, cool and confine antiprotons in vacuo, using a sequential combination of the Antiproton Decelerator (AD) at CERN, a Radio-Frequency Quadrupole Decelerator (RFQD), and an electromagnetic trap. Our recent success in stable extraction of monoenergetic ultra-slow antiprotons, about 3x10{sup 5} in number available every 5 minutes, has opened up the possibility to study ionization and atomic capture processes between an antiproton thus provided as a beam and an atom prepared in the form of a supersonic gas-jet target, at an unprecedented low energy from 10 eV to 1 keV under the single-collision condition. Our design and strategy of the cross-beam experiments are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electron cyclotron resonance heating by magnetic filter field in a negative hydrogen ion source

The influence of magnetic filter field on plasma properties in the heating region has been investigated in a planar-type inductively coupled radio-frequency (RF) H{sup −} ion source. Besides filtering high energy electrons near the extraction region, the magnetic filter field is clearly observed to increase the electron temperature in the heating region at low pressure discharge. With increasing the operating pressure, enhancement of electron temperature in the heating region is reduced. The possibility of electron cyclotron resonance (ECR) heating in the heating region due to stray magnetic field generated by a filter magnet located at the extraction region is examined. It is found that ECR heating by RF wave field in the discharge region, where the strength of an axial magnetic field is approximately ∼4.8 G, can effectively heat low energy electrons. Depletion of low energy electrons in the electron energy distribution function measured at the heating region supports the occurrence of ECR heating. The present study suggests that addition of axial magnetic field as small as several G by an external electromagnet or permanent magnets can greatly increase the generation of highly ro-vibrationally excited hydrogen molecules in the heating region, thus improving the performance of H{sup −} ion generation in volume-produced negative hydrogen ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural, vibrational, thermal and optical studies of organic single crystal: Benzotriazolium p-toluene sulfonate (BTPTS)

Benzotriazolium p-toluene sulfonate (BTPTS) was grown by solution growth technique. The powder X-ray diffraction analysis was carried out to evaluate crystal system of the compound. LeBail Profile fitting analysis was performed to extract the individual peak intensities. FTIR spectrum analysis was recorded to study vibration frequencies of the prepared organic salt. Thermal studies were carried out using TG-DSC analysis. Optical absorption and energy band gap of the title compound was evaluated by UV-Vis spectral study.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Primary processes in the bacterial reaction center probed by two-dimensional electronic spectroscopy

In the initial steps of photosynthesis, reaction centers convert solar energy to stable charge-separated states with near-unity quantum efficiency. The reaction center from purple bacteria remains an important model system for probing the structure–function relationship and understanding mechanisms of photosynthetic charge separation. Here we perform 2D electronic spectroscopy (2DES) on bacterial reaction centers (BRCs) from two mutants of the purple bacterium Rhodobacter capsulatus , spanning the Q y absorption bands of the BRC. We analyze the 2DES data using a multiexcitation global-fitting approach that employs a common set of basis spectra for all excitation frequencies, incorporating inputs from the linear absorption spectrum and the BRC structure. We extract the exciton energies, resolving the previously hidden upper exciton state of the special pair. We show that the time-dependent 2DES data are well-represented by a two-step sequential reaction scheme in which charge separation proceeds from the excited state of the special pair (P*) to P + H A − via the intermediate P + B A − . When inhomogeneous broadening and Stark shifts of the B* band are taken into account we can adequately describe the 2DES data without the need to introduce a second charge-separation pathway originating from the excited state of the monomeric bacteriochlorophyll B A *.

59 BASIC BIOLOGICAL SCIENCES↗

Bridging the Gap: Thermal Properties in Composites from Microscale Constituents to Macroscale Performance

In this work, a finite element analysis model was developed to predict the frequency domain thermal response to heat input from a gaussian heat source for arbitrary 2-dimensional geometries. The model was used for geometric parameter fitting of samples experimentally measured using Frequency Domain Thermoreflectance (FDTR). Inverse fitting was performed to on experimental data to extract characteristic geometries of samples with feature sizes smaller than the Il e 2 radius of the laser used to probe the system. Further simulations were done to demonstrate the ability of the system to detect a variety of feature types. Silicon wafers with 50 nm to 1 pm of wet thermal oxide were measured and fit. Finally, microparticles suspended in epoxy were imaged using FDTR.

42 ENGINEERING↗

Radio wave propagation experiments to probe the ionosphere

Ionospheric bias corrections associated with radio tracking of spacecraft depend on the following measuring techniques for integrated electron content: (1) Faraday rotation measurements from an earth synchronous satellite; (2) ranging measurements at two frequencies; and (3) group and phase velocity measurements obtained from tracking data. The extraction of the integrated electron content directly from tracking data is achieved by comparison of range-rate measurements based on Doppler shift with differentiated range measurements based on tone delay. This method is most desirable because the measured corrections pertain directly to the spacecraft whose orbit is being determined and can be used in near earth as well as deep space tracking data.

Schmid, P. E.↗

Slosh testing of a spherical mercury propellant tank with positive-expulsion diaphragm

A preliminary investigation was conducted to evaluate the lateral slosh characteristics of a 23-cm diameter mercury propellant tank with a positive-expulsion diaphragm and 17.5% ullage. Data are presented for tank sinusoidal acceleration levels between 0.05 and 0.5 g at frequencies ranging from 5 to 50 Hz. Results indicate that slosh characteristics are highly nonlinear at acceleration levels approaching those in flight, and depend heavily on the shape and stiffness of the diaphragm. Nyquist plots of driving force over acceleration are shown to be a useful tool for determining natural frequency, damping, and modal mass characteristics. A computerized nonlinear least squares method for extracting the modal parameters from the Nyquist plots is described and results of applying the method are presented.

Ross, R. G., Jr.↗

Noncoherent sampling technique for communications parameter estimations

This paper presents a method of noncoherent demodulation of the PSK signal for signal distortion analysis at the RF interface. The received RF signal is downconverted and noncoherently sampled for further off-line processing. Any mismatch in phase and frequency is then compensated for by the software using the estimation techniques to extract the baseband waveform, which is needed in measuring various signal parameters. In this way, various kinds of modulated signals can be treated uniformly, independent of modulation format, and additional distortions introduced by the receiver or the hardware measurement instruments can thus be eliminated. Quantization errors incurred by digital sampling and ensuing software manipulations are analyzed and related numerical results are presented also.

Su, Y. T.↗

Database tomography for commercial application

Database tomography is a method for extracting themes and their relationships from text. The algorithms, employed begin with word frequency and word proximity analysis and build upon these results. When the word 'database' is used, think of medical or police records, patents, journals, or papers, etc. (any text information that can be computer stored). Database tomography features a full text, user interactive technique enabling the user to identify areas of interest, establish relationships, and map trends for a deeper understanding of an area of interest. Database tomography concepts and applications have been reported in journals and presented at conferences. One important feature of the database tomography algorithm is that it can be used on a database of any size, and will facilitate the users ability to understand the volume of content therein. While employing the process to identify research opportunities it became obvious that this promising technology has potential applications for business, science, engineering, law, and academe. Examples include evaluating marketing trends, strategies, relationships and associations. Also, the database tomography process would be a powerful component in the area of competitive intelligence, national security intelligence and patent analysis. User interests and involvement cannot be overemphasized.

Kostoff, Ronald N.↗

Plasma membrane ordering agent pluronic F-68 (PF-68) reduces neurotransmitter uptake and release and produces learning and memory deficits in rats

A substantial body of evidence indicates that aged-related changes in the fluidity and lipid composition of the plasma membrane contribute to cellular dysfunction in humans and other mammalian species. In the CNS, reductions in neuronal plasma membrane order (PMO) (i.e., increased plasma membrane fluidity) have been attributed to age as well as the presence of the beta-amyloid peptide-25-35, known to play an important role in the neuropathology of Alzheimer's disease (AD). These PMO increases may influence neurotransmitter synthesis, receptor binding, and second messenger systems as well as signal transduction pathways. The effects of neuronal PMO on learning and memory processes have not been adequately investigated, however. Based on the hypothesis that an increase in PMO may alter a number of aspects of synaptic transmission, we investigated several neurochemical and behavioral effects of the membrane ordering agent, PF-68. In cell culture, PF-68 (nmoles/mg SDS extractable protein) reduced [3H]norepinephrine (NE) uptake into differentiated PC-12 cells as well as reduced nicotine stimulated [3H]NE release. The compound (800-2400 microg/kg, i.p., resulting in nmoles/mg SDS extractable protein in the brain) decreased step-through latencies and increased the frequencies of crossing into the unsafe side of the chamber in inhibitory avoidance training. In the Morris water maze, PF-68 increased the latencies and swim distances required to locate a hidden platform and reduced the time spent and distance swam in the previous target quadrant during transfer (probe) trials. PF-68 did not impair performance of a well-learned working memory task, the rat delayed stimulus discrimination task (DSDT), however. Studies with 14C-labeled PF-68 indicated that significant (pmoles/mg wet tissue) levels of the compound entered the brain from peripheral (i.p.) injection. No PF-68 related changes were observed in swim speeds or in visual acuity tests in water maze experiments, rotorod performance, or in tests of general locomotor activity. Furthermore, latencies to select a lever in the DSDT were not affected. These results suggest that PF-68 induced deficits in learning and memory without confounding peripheral motor, sensory, or motivational effects at the tested doses. Furthermore, none of the doses induced a conditioned taste aversion to a novel 0.1% saccharin solution indicating a lack of nausea or gastrointestinal malaise induced by the compound. The data indicate that increases in neuronal plasma membrane order may have significant effects on neurotransmitter function as well as learning and memory processes. Furthermore, compounds such as PF-68 may also offer novel tools for studying the role of neuronal PMO in mnemonic processes and changes in PMO resulting from age-related disorders such as AD.

Poloxamer/pharmacology↗

Composite Characterization Using Laser Doppler Vibrometry and Multi-Frequency Wavenumber Analysis

NASA has recognized the need for better characterization of composite materials to support advances in aeronautics and the next generation of space exploration vehicles. An area of related research is the evaluation of impact induced delaminations. Presented is a non-contact method of measuring the ply depth of impact delamination damage in a composite through use of a Scanning Laser Doppler Vibrometer (SLDV), multi-frequency wavenumber analysis, and a wavenumber-ply correlation algorithm. A single acquisition of a chirp excited lamb wavefield in an impacted composite is post-processed into a numerous single frequency excitation wavefields through a deconvolution process. A spatially windowed wavenumber analysis then extracts local wavenumbers from the wavefield, which are then correlated to theoretical dispersion curves for ply depth determination. SLDV based methods to characterize as-manufactured composite variation using wavefield analysis will also be discussed.

Juarez, Peter↗

Non-contact fluid characterization in containers using ultrasonic waves

Apparatus and method for non-contact (stand-off) ultrasonic determination of certain characteristics of fluids in containers or pipes are described. A combination of swept frequency acoustic interferometry (SFAI), wide-bandwidth, air-coupled acoustic transducers, narrowband frequency data acquisition, and data conversion from the frequency domain to the time domain, if required, permits meaningful information to be extracted from such fluids.

47 OTHER INSTRUMENTATION↗