Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The Use of Cone Beam Computed Tomography for Image Guided Gamma Knife Stereotactic Radiosurgery: Initial Clinical Evaluation

Purpose: The present study used cone beam computed tomography (CBCT) to measure the inter- and intrafraction uncertainties for intracranial stereotactic radiosurgery (SRS) using the Leksell Gamma Knife (GK). Methods and Materials: Using a novel CBCT system adapted to the GK radiosurgery treatment unit, CBCT images were acquired immediately before and after treatment for each treatment session within the context of a research ethics board–approved prospective clinical trial. Patients were immobilized in the Leksell coordinate frame (LCF) for both volumetric CBCT imaging and GK-SRS delivery. The relative displacement of the patient's skull to the stereotactic reference (interfraction motion) was measured for each CBCT scan. Differences between the pre- and post-treatment CBCT scans were used to determine the intrafraction motion. Results: We analyzed 20 pre- and 17 post-treatment CBCT scans in 20 LCF patients treated with SRS. The mean translational pretreatment setup error ± standard deviation in the left-right, anteroposterior, and craniocaudal directions was −0.19 ± 0.32, 0.06 ± 0.27, and −0.23 ± 0.2 mm, with a maximum of −0.74, −0.53, and −0.68 mm, respectively. After an average time between the pre- and post-treatment CBCT scans of 82 minutes (range 27-170), the mean intrafraction error ± standard deviation for the LCF was −0.03 ± 0.05, −0.03 ± 0.18, and −0.03 ± 0.12 mm in the left-right, anteroposterior, and craniocaudual direction, respectively. Conclusions: Using CBCT on a prototype image guided GK Perfexion unit, we were able to measure the inter- and intrafraction positional changes for GK-SRS using the invasive frame. In the era of image guided radiation therapy, the use of CBCT image guidance for both frame- and non–frame-based immobilization systems could serve as a useful quality assurance tool. Our preliminary measurements can guide the application of achievable thresholds for inter- and intrafraction discrepancy when moving to a frameless approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for multichannel dosimetry with EBT3 radiochromic films

Purpose: An improved method for multichannel dosimetry is presented. This method explicitly takes into account the information provided by the unexposed image of the film. Methods: The method calculates the dose by applying a couple of perturbations to the scanned dose, one dependent and the other independent on the color channel. The method has been compared with previous multichannel and two single channel methods (red and green) against measurements using two different tests: first, five percentage depth dose profiles covering a wide range of doses; second, the dose map perpendicular to the beam axis for a 15 × 15cm{sup 2} square field. Finally, the results of 30 IMRT quality assurances tests are presented. All tests have been evaluated using the gamma analysis. Results: The coefficient of variation was found to be similar for all methods in a wide range of doses. The results of the proposed method are more in agreement with the experimental measurements and with the treatment planning system. Furthermore, the differences in the mean gamma pass rates are statistically significant. Conclusions: The improved multichannel dosimetric method is able to remove many of the common disturbances usually present in radiochromic films and improves the gamma analysis results compared with the other three methods.

61 RADIATION PROTECTION AND DOSIMETRY↗

Studies of defects in combustion synthesized europium-doped LiAl{sub 5}O{sub 8} red phosphor

Europium-doped LiAl{sub 5}O{sub 8} red phosphor was prepared using a self-propagating (combustion) synthesis. The formation of crystalline LiAl{sub 5}O{sub 8} was confirmed by X-ray diffraction. The morphological aspect of the resulting powders was examined by scanning electron microscopy. Electron spin resonance studies have been carried out in order to study the characteristics of the defect centres and the thermoluminescence (TL) peaks observed in this phosphor. Two types of centres (centre I and centre II) have been identified in LiAl{sub 5}O{sub 8}:Eu. Centre I is characteristic of a species exhibiting an isotropic g-value 2.0089 with a line width of 70 G and is assigned to a V-centre. Centre II is also characterized by an isotropic g-value 2.0059 with a line width of about 10 G. Centre II is ascribed to a F{sup +}-centre. A room temperature photoluminescence study shows a strong emission line at 613 nm corresponding to the {sup 5}D{sub 0}{yields}{sup 7}F{sub 2} transition of Eu{sup 3+} ions. - Graphical abstract: LiAl{sub 5}O{sub 8}:Eu{sup 3+} phosphors have been synthesized in a very short time (lt;5 min) by combustion process and are well characterized by XRD and SEM. TL glow peak was observed in gamma-irradiated Eu ion-doped LiAl{sub 5}O{sub 8} at around 180 deg. C. Electron spin resonance studies have been carried out in order to study the characteristics of the defect centres. Photoluminescence studies showed red emission located at about 613 nm and is ascribed to {sup 5}D{sub 0}-{sup 7}F{sub 2} transition of Eu{sup 3+} ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements

Purpose: Four-dimensional computed tomography (4DCT) can be used to make measurements of pulmonary function longitudinally. The sensitivity of such measurements to identify change depends on measurement uncertainty. Previously, intrasubject reproducibility of Jacobian-based measures of lung tissue expansion was studied in two repeat prior-RT 4DCT human acquisitions. Difference in respiratory effort such as breathing amplitude and frequency may affect longitudinal function assessment. In this study, the authors present normalization schemes that correct ventilation images for variations in respiratory effort and assess the reproducibility improvement after effort correction.Methods: Repeat 4DCT image data acquired within a short time interval from 24 patients prior to radiation therapy (RT) were used for this analysis. Using a tissue volume preserving deformable image registration algorithm, Jacobian ventilation maps in two scanning sessions were computed and compared on the same coordinate for reproducibility analysis. In addition to computing the ventilation maps from end expiration to end inspiration, the authors investigated the effort normalization strategies using other intermediated inspiration phases upon the principles of equivalent tidal volume (ETV) and equivalent lung volume (ELV). Scatter plots and mean square error of the repeat ventilation maps and the Jacobian ratio map were generated for four conditions: no effort correction, global normalization, ETV, and ELV. In addition, gamma pass rate was calculated from a modified gamma index evaluation between two ventilation maps, using acceptance criterions of 2 mm distance-to-agreement and 5% ventilation difference.Results: The pattern of regional pulmonary ventilation changes as lung volume changes. All effort correction strategies improved reproducibility when changes in respiratory effort were greater than 150 cc (p < 0.005 with regard to the gamma pass rate). Improvement of reproducibility was correlated with respiratory effort difference (R = 0.744 for ELV in the cohort with tidal volume difference greater than 100 cc). In general for all subjects, global normalization, ETV and ELV significantly improved reproducibility compared to no effort correction (p = 0.009, 0.002, 0.005 respectively). When tidal volume difference was small (less than 100 cc), none of the three effort correction strategies improved reproducibility significantly (p = 0.52, 0.46, 0.46 respectively). For the cohort (N = 13) with tidal volume difference greater than 100 cc, the average gamma pass rate improves from 57.3% before correction to 66.3% after global normalization, and 76.3% after ELV. ELV was found to be significantly better than global normalization (p = 0.04 for all subjects, and p = 0.003 for the cohort with tidal volume difference greater than 100 cc).Conclusions: All effort correction strategies improve the reproducibility of the authors' pulmonary ventilation measures, and the improvement of reproducibility is highly correlated with the changes in respiratory effort. ELV gives better results as effort difference increase, followed by ETV, then global. However, based on the spatial and temporal heterogeneity in the lung expansion rate, a single scaling factor (e.g., global normalization) appears to be less accurate to correct the ventilation map when changes in respiratory effort are large.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical measurements were 0.97 ± 0.03 and 1.10 ± 0.13, respectively, indicating that the accuracy of the Monte Carlo simulation was adequate. The normalized AGD with VOI field scans was substantially reduced by a factor of about 2 over the VOI region and by a factor of 18 over the entire breast for both 25% and 50% VGF simulated breasts compared with the normalized AGD with full field scans. The normalized AGD for the VOI breast CT technique can be kept the same as or lower than that for a full field scan with the exposure level for the VOI field scan increased by a factor of as much as 12. Conclusions: The authors’ Monte Carlo estimates of normalized AGDs for the VOI breast CT technique show that this technique can be used to markedly increase the dose to the breast and thus the visibility of the VOI region without increasing the dose to the breast. The results of this investigation should be helpful for those interested in using VOI breast CT technique to image small calcifications with dose concern.

60 APPLIED LIFE SCIENCES↗

A search for time-dependent astrophysical neutrino emission with icecube data from 2012 to 2017

High-energy neutrinos are unique messengers of the high-energy universe, tracing the processes of cosmic ray acceleration. This work presents analyses focusing on time-dependent neutrino point-source searches. A scan of the whole sky, making no prior assumption about source candidates, is performed, looking for a space and time clustering of high-energy neutrinos in data collected by the IceCube Neutrino Observatory between 2012 and 2017. No statistically significant evidence for a time-dependent neutrino signal is found with this search during this period, as all results are consistent with the background expectation. Within this study period, the blazar 3C 279, showed strong variability, inducing a very prominent gamma-ray flare observed in 2015 June. This event motivated a dedicated study of the blazar, which consists of searching for a time-dependent neutrino signal correlated with the gamma-ray emission. No evidence for a time-dependent signal is found. Hence, an upper limit on the neutrino fluence is derived, allowing us to constrain a hadronic emission model.

79 ASTRONOMY AND ASTROPHYSICS↗

The Spectrum of the Cosmic X-ray Background Observed by RTXE/PCA

We have analyzed a large set of Rossi X-ray Timing Explorer/Proportional Counter Array (RXTE/PCA) scanning and slewing observations performed between April 1996 and March 1999. We obtained the 3-20 keV spectrum of the cosmic X-ray background (CXB) by subtracting Earth-occulted observations from observations of the X-ray sky at high galactic latitude and far away from sources. The sky coverage is approximately 22.6 x 10(exp 3) square degrees. The PCA spectrum of CXB in 3-20 keV energy band is adequately approximated by a single power law with photon index GAMMA approximately 1.4 and normalization at 1 keV approximately 9.5 phot/s/square centimeter/keV/sr. Instrumental background uncertainty precludes accurate RXTE/PCA measurements of the spectrum of cosmic X-ray background at energies above 15 keV and therefore we cannot detect the high energy cutoff observed by the High Energy Astronomical Observatory (HEAO)-1 A2 experiment. Deep observations of the 6 high latitude points used to model the PCA background provide a coarse measure of the spatial variation of the CXB. The CXB variations are consistent with a fixed spectral shape and variable normalization characterized by a fractional rms amplitude of approximately 7% on angular scales of approximately 1 square deg.

Revnivtsev, M.↗

Dual ring multilayer ionization chamber and theory-based correction technique for scanning proton therapy

Purpose: To develop a multilayer ionization chamber (MLIC) and a correction technique that suppresses differences between the MLIC and water phantom measurements in order to achieve fast and accurate depth dose measurements in pencil beam scanning proton therapy. Methods: The authors distinguish between a calibration procedure and an additional correction: 1—the calibration for variations in the air gap thickness and the electrometer gains is addressed without involving measurements in water; 2—the correction is addressed to suppress the difference between depth dose profiles in water and in the MLIC materials due to the nuclear interaction cross sections by a semiempirical model tuned by using measurements in water. In the correction technique, raw MLIC data are obtained for each energy layer and integrated after multiplying them by the correction factor because the correction factor depends on incident energy. The MLIC described here has been designed especially for pencil beam scanning proton therapy. This MLIC is called a dual ring multilayer ionization chamber (DRMLIC). The shape of the electrodes allows the DRMLIC to measure both the percentage depth dose (PDD) and integrated depth dose (IDD) because ionization electrons are collected from inner and outer air gaps independently. Results: IDDs for which the beam energies were 71.6, 120.6, 159, 180.6, and 221.4 MeV were measured and compared with water phantom results. Furthermore, the measured PDDs along the central axis of the proton field with a nominal field size of 10 × 10 cm{sup 2} were compared. The spread out Bragg peak was 20 cm for fields with a range of 30.6 and 3 cm for fields with a range of 6.9 cm. The IDDs measured with the DRMLIC using the correction technique were consistent with those that of the water phantom; except for the beam energy of 71.6 MeV, all of the points satisfied the 1% dose/1 mm distance to agreement criterion of the gamma index. The 71.6 MeV depth dose profile showed slight differences in the shallow region, but 94.5% of the points satisfied the 1%/1 mm criterion. The 90% ranges, defined at the 90% dose position in distal fall off, were in good agreement with those in the water phantom, and the range differences from the water phantom were less than ±0.3 mm. The PDDs measured with the DRMLIC were also consistent with those that of the water phantom; 97% of the points passed the 1%/1 mm criterion. Conclusions: It was demonstrated that the new correction technique suppresses the difference between the depth dose profiles obtained with the MLIC and those obtained from a water phantom, and a DRMLIC enabling fast measurements of both IDD and PDD was developed. The IDDs and PDDs measured with the DRMLIC and using the correction technique were in good agreement with those that of the water phantom, and it was concluded that the correction technique and DRMLIC are useful for depth dose profile measurements in pencil beam scanning proton therapy.

60 APPLIED LIFE SCIENCES↗

Conductance quantization of an ideal Sharvin contact

Thorough calculations of the conductance of an idealized quantum point contact are presented. The point contact is modelled as a configuration in which two conductive half-spaces are separated by a non-conductive planar screen with a circular window of a given radius a. The screen is considered as opaque for the electrons with the exception of the window. From the viewpoint of the electrical conduction, the half-spaces are interpreted as leads which are perfectly coalesced with one another across the window. We assume that the leads are reservoirs of a strongly degenerate gas of electrons. If the leads are made from an n-type degenerate semiconductor, the Fermi wavelength {lambda}{sub F} = 2{pi}/k{sub F} = 2{pi}/(3{pi}{sup 2}n){sup 1/3} may be tens of nanometers. The theory of the conductance {gamma}{sub S} of such a point contact is reconsidered. Within the framework of the approximation that we use assuming that T = 0, we show that the dependence of {gamma}{sub S} on the variable k{sub F}a manifests curved steps terminated by singular spikes. Owing to stochastic influences, the spikes should be seen as maxima in measured spectra. We predict that these maxima should demarcate the edges of the steps in the {gamma}{sub S} vs. k{sub F}a plot. This prediction is in agreement with the STM observations reported recently by Nagaoka et al. [K. Nagaoka, S. Yaginuma, T. Nagao, T. Nakayama, Phys. Rev. B. 74 (2006) 033310].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-371: Evaluating the Convolution Algorithm of a Commercially Available Radiosurgery Irradiator Using a Novel Phantom

Purpose: The purpose of this study was to develop and use a novel phantom to evaluate the accuracy and usefulness of the Leskell Gamma Plan convolution-based dose calculation algorithm compared with the current TMR10 algorithm. Methods: A novel phantom was designed to fit the Leskell Gamma Knife G Frame which could accommodate various materials in the form of one inch diameter, cylindrical plugs. The plugs were split axially to allow EBT2 film placement. Film measurements were made during two experiments. The first utilized plans generated on a homogeneous acrylic phantom setup using the TMR10 algorithm, with various materials inserted into the phantom during film irradiation to assess the effect on delivered dose due to unplanned heterogeneities upstream in the beam path. The second experiment utilized plans made on CT scans of different heterogeneous setups, with one plan using the TMR10 dose calculation algorithm and the second using the convolution-based algorithm. Materials used to introduce heterogeneities included air, LDPE, polystyrene, Delrin, Teflon, and aluminum. Results: The data shows that, as would be expected, having heterogeneities in the beam path does induce dose delivery error when using the TMR10 algorithm, with the largest errors being due to the heterogeneities with electron densities most different from that of water, i.e. air, Teflon, and aluminum. Additionally, the Convolution algorithm did account for the heterogeneous material and provided a more accurate predicted dose, in extreme cases up to a 7–12% improvement over the TMR10 algorithm. The convolution algorithm expected dose was accurate to within 3% in all cases. Conclusion: This study proves that the convolution algorithm is an improvement over the TMR10 algorithm when heterogeneities are present. More work is needed to determine what the heterogeneity size/volume limits are where this improvement exists, and in what clinical and/or research cases this would be relevant.

60 APPLIED LIFE SCIENCES↗

An all sky study of fast X-ray transients

In the HEAO 1 A-2 survey of fast X-ray transients, a search of 2 to 20 keV scanning data was made for brief increases in flux, greater than 4 millicrabs, on timescales approximately 1 to 10 to the 4th s above a 12-hour average. The search was divided into two regions, and all-sky survey of the Galaxy, and a survey of the Magellanic Clouds. In the latter, 37 events were found and identified with 4 of the 5 brighest sources in the LMC, plus 2 as flares from a foreground star. Np X-ray bursts, no gamma-ray bursts, and no events from the SMC were found. In the all-sky survey, after excluding well-known variable sources, out of the equivalent of approximately 104 days of data, 15 events were found which falling into 2 broad categories: flares from coronal sources, roughly isotropically distributed, with optically thin thermal spectra; and harder fast transients apparently distributed near the Galactic plane. The first were identified as flares from ubiquitous active cool dwarf stars. It was hypothesized that the second may have been from distant Be-neutron star binaries. However, at least two of the harder, more luminous events remained unidentified. Future research should examine the nature of these rare events, and how they may fit into a hierarchy of hard fast transients from gamma-ray bursts to outbursts from pulsar systems.

Connors, Alanna↗

Evaluation of Cloud-Resolving and Limited Area Model Intercomparison Simulations Using TWP-ICE Observations: Precipitation Microphysics - Part 2

Ten 3-D cloud-resolving model (CRM) simulations and four 3-D limited area model (LAM) simulations of an intense mesoscale convective system observed on 23-24 January 2006 during the Tropical Warm Pool-International Cloud Experiment (TWP-ICE) are compared with each other and with observations and retrievals from a scanning polarimetric radar, colocated UHF and VHF vertical profilers, and a Joss-Waldvogel disdrometer in an attempt to explain a low bias in simulated stratiform rainfall. Despite different forcing methodologies, similar precipitation microphysics errors appear in CRMs and LAMs with differences that depend on the details of the bulk microphysics scheme used. One-moment schemes produce too many small raindrops, which biases Doppler velocities low, but produces rainwater contents (RWCs) that are similar to observed. Two-moment rain schemes with a gamma shape parameter (mu) of 0 produce excessive size sorting, which leads to larger Doppler velocities than those produced in one-moment schemes but lower RWCs. Two-moment schemes also produce a convective median volume diameter distribution that is too broad relative to observations and, thus, may have issues balancing raindrop formation, collision-coalescence, and raindrop breakup. Assuming a mu of 2.5 rather than 0 for the raindrop size distribution improves one-moment scheme biases, and allowing mu to have values greater than 0 may improve excessive size sorting in two-moment schemes. Underpredicted stratiform rain rates are associated with underpredicted ice water contents at the melting level rather than excessive rain evaporation, in turn likely associated with convective detrainment that is too high in the troposphere and mesoscale circulations that are too weak. A limited domain size also prevents a large, well-developed stratiform region like the one observed from developing in CRMs, although LAMs also fail to produce such a region.

three dimensional models↗

Electron microscopy characterization of an as-fabricated research reactor fuel plate comprised of U-7Mo particles dispersed in an Al-2Si alloy matrix

To understand the microstructural development of nuclear fuel plates during irradiation, it is imperative to know the microstructure of a fuel plate after all the fabrication steps have been completed and before it is inserted into the reactor. To this end, a U-7 wt.% Mo alloy research reactor dispersion fuel plate with Al-2 wt.% Si matrix was destructively examined using scanning and transmission electron microscopy to characterize the developed microstructure after fabrication. Of particular interest for this study was how the Si that was added to the fuel matrix partitioned between the various fuel plate phases during fabrication. Si was added to the matrix so that the microstructure that developed during fuel fabrication would exhibit good irradiation behavior. SEM analysis was used to identify the representative microstructure, the compositions of the various phases, and the partitioning behavior of the fuel and matrix constituents. TEM analysis was employed to definitively identify the phases in the U-7Mo alloy and the phases that formed due to diffusional interactions between the fuel particles and matrix during fuel plate fabrication. The TEM results are the first reported for an as-fabricated U-7 wt.% Mo dispersion fuel plate with an Al alloy matrix. SEM results showed that a significant portion of the original {gamma}-(U-Mo) fuel particles had transformed to a lamellar microstructure, comprised of {alpha}-U and either {gamma} or {gamma}' phases, and the fuel/matrix interaction layers were enriched in Si. TEM analysis identified an ordered fcc (U-Mo)(Al-Si){sub 3} type of phase, which formed at the decomposed U-7Mo/matrix interface and extended into the lamellar microstructure. Some regions of the U-7Mo particles retained the single-phase {gamma}-(U-Mo). Small precipitate phases were observed in the fuel meat matrix that contained Fe, Al, and Si. The Si that is added to the matrix of a U-Mo dispersion fuel plate to improve irradiation performance appears to result in the creation of a Si-rich (U-Mo)(Al-Si){sub 3} type of fuel/matrix interaction layer during fabrication that appears to exhibit favorable behavior during irradiation compared to the behavior of the layers that form in U-Mo dispersion fuel plates without Si in the matrix. - Research Highlights: {yields}Si seems to positively affect the microstructure of an as-fabricated fuel plate. {yields}Si modifications to the fuel plate exhibit favorable performance during irradiation. {yields}Si interdiffuses faster than Al.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Post Irradiation Examination of Pressurized Water Reactor Stainless Steel Internal Components

Internal structural components of pressurized water reactors (PWR), such as baffle former bolts, are subjected to significant neutron irradiation and mechanical stresses at elevated temperatures during plant operation. Over the long operation of the power plant, these conditions lead to potential degradation and reduced load-carrying capacity of these bolts. To understand property degradation more fully, to confirm the results of experimental irradiation programs, and to predict operational lifetime performance of structural materials in internal components, post irradiation examination of harvested materials from operating nuclear reactors is required. In this work, two high fluence 316 stainless steel baffle former bolts were retrieved from a commercial Westinghouse two-loop downflow type PWR and then sectioned for analysis via mechanical testing and microstructural characterization. The irradiation damage fluctuated along the bolt length with damage levels from 15 to 41 displacements per atom with the bolt head receiving approximately twice the neutron damage levels as that of the bolt thread section. Mechanical testing evaluations showed extensive irradiation hardening and a sharp decrease in fracture toughness in all parts of the bolt, though with limited variation along the bolt length. Microstructural characterization using analytical scanning transmission electron microscopy and atom probe tomography showed significant radiation induced precipitation, segregation, and dislocation loop and cavity formation. However, unlike the mechanical behavior, there was considerable variation along the bolt length but opposite of what may be expected, with more precipitation and cavity formation in the bolt thread where the neutron radiation dose is less than in the bolt head where the neutron radiation dose is higher. The cause of this variation is likely due to gradients in temperature, neutron energy spectra, and gamma irradiation.

Lach, Tim↗

SU-E-T-120: Analytic Dose Verification for Patient-Specific Proton Pencil Beam Scanning Plans

Purpose: To independently verify the QA dose of proton pencil beam scanning (PBS) plans using an analytic dose calculation model. Methods: An independent proton dose calculation engine is created using the same commissioning measurements as those employed to build our commercially available treatment planning system (TPS). Each proton PBS plan is exported from the TPS in DICOM format and calculated by this independent dose engine in a standard 40 x 40 x 40 cm water tank. This three-dimensional dose grid is then compared with the QA dose calculated by the commercial TPS, using standard Gamma criterion. A total of 18 measured pristine Bragg peaks, ranging from 100 to 226 MeV, are used in the model. Intermediate proton energies are interpolated. Similarly, optical properties of the spots are measured in air over 15 cm upstream and downstream, and fitted to a second-order polynomial. Multiple Coulomb scattering in water is approximated analytically using Preston and Kohler formula for faster calculation. The effect of range shifters on spot size is modeled with generalized Highland formula. Note that the above formulation approximates multiple Coulomb scattering in water and we therefore chose not use the full Moliere/Hanson form. Results: Initial examination of 3 patient-specific prostate PBS plans shows that agreement exists between 3D dose distributions calculated by the TPS and the independent proton PBS dose calculation engine. Both calculated dose distributions are compared with actual measurements at three different depths per beam and good agreements are again observed. Conclusion: Results here showed that 3D dose distributions calculated by this independent proton PBS dose engine are in good agreement with both TPS calculations and actual measurements. This tool can potentially be used to reduce the amount of different measurement depths required for patient-specific proton PBS QA.

60 APPLIED LIFE SCIENCES↗

WDR-PK-AK-018

Method - CES SOP-HW-P556 'Field and Bulk Gamma Analysis'. Detector - High-purity germanium, 40% relative efficiency. Calibration - The detector was calibrated on February 8, 2006 using a NIST-traceable sealed source, and the calibration was verified using an independent sealed source. Count Time and Geometry - The sample was counted for 20 minutes at 72 inches from the detector. A lead collimator was used to limit the field-of-view to the region of the sample. The drum was rotated 180 degrees halfway through the count time. Date and Location of Scans - June 1,2006 in Building 235 Room 1136. Spectral Analysis Spectra were analyzed with ORTEC GammaVision software. Matrix and geometry corrections were calculated using OR TEC Isotopic software. A background spectrum was measured at the counting location. No man-made radioactivity was observed in the background. Results were determined from the sample spectra without background subtraction. Minimum detectable activities were calculated by the Nureg 4.16 method. Results - Detected Pu-238, Pu-239, Am-241 and Am-243.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Purification and Crystal Growth of Lead Iodide by Physical Vapor Transport Method

Lead iodide (PbI2) is a layered compound semiconductor being developed as room temperature x- and gamma-ray detector. Compared to the more studied material, mercuric iodide, PbI2 has a higher melting temperature and no phase transition until liquid phase which are indications of better mechanical properties. In this study, the source material was purified by the zone-refining process, and the purest section was extracted from center of the the zone-refined ingot to be grown by physical vapor transport (PVT) method. The zone-refined material and as-grown crystals were characterized by optical microscopy and differential scanning calorimetry (DSC) to reveal the surface morphology, purity and stoichiometry. The results shows that both materials are near-stoichiometric composition, with the purity of the as-grown crystals higher than zone-refined materials. The resistivity of the as-grown crystal (10" Omega-cm) was derived from current-voltage (I-V) measurement, and is 10 times higher than the zone-refined materials. Detail results will be presented and discussed.

Wright, G. W.↗

16 November 1979 gamma-ray bursts observed with HEAO-3 High-Resolution Gamma-Ray Spectrometer

On 1979 November 16, two gamma-ray bursts were observed by the High-Resolution Gamma-Ray Spectrometer on HEAO-3. The first event occurred at 14:16:41 U.T. and lasted about eight seconds. This event was detected only by the instrument's five CsI anticoincidence shield pieces. The second event occurred 61 sec later, at 14:17:42, and lasted about 18 sec. This event was clearly detected by the high-resolution germanium detectors. Because of the close temporal coincidence of the two events, the possibility is considered that both events originated from one celestial source, and that the scanning motion of HEAO-3 (nominal spin period 20 min) excluded the first from the approximately 30 deg FWHM field of view of the germanium detectors but included the second. Directional information from the relative response of the five shield pieces and the earth occultation constraint are all consistent with this interpretation and suggest a source location near RA equals 10 hr, Dec equals 45 deg. No significant spectral features appear in the high-resolution data from the second burst.

Wheaton, W. A.↗