Jet formation in GRBs: a semi-analytic model of MHD flow in Kerr geometry with realistic plasma injection

We construct a semi-analytic model for magnetohydrodynamic (MHD) flows in Kerr geometry that incorporates energy loading via neutrino annihilation on magnetic field lines threading the horizon. We compute the structure of the double-flow established in the magnetisphere for a wide range of energy injection rates and identify the different operation regimes. At low injection rates, the outflow is powered by the spinning black hole via the Blandford-Znajek mechanism, whereas at high injection rates, it is driven by the pressure of the plasma deposited on magnetic field lines. In the intermediate regime, both processes contribute to the outflow formation. The parameter that quantifies the load is the ratio of the net power injected below the stagnation radius and the maximum power that can be extracted magnetically from the black hole.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a 100V Half-Bridge MOSFET Driver, Type MIC4103, Over a Wide Temperature Range

The operation of a high frequency, high voltage MOSFET (metal-oxide semiconductor field-effect transistors) driver was investigated over a wide temperature regime that extended beyond its specified range. The Micrel MIC4103 is a 100V, non-inverting, dual driver that is designed to independently drive both high-side and low-side N-channel MOSFETs. It features fast propagation delay times and can drive 1000 pF load with 10ns rise times and 6 ns fall times [1]. The device consumes very little power, has supply under-voltage protection, and is rated for a -40 C to +125 C junction temperature range. The floating high-side driver of the chip can sustain boost voltages up to 100 V. Table I shows some of the device manufacturer s specification.

Patterson, Richard L.↗

Anomolous Fatigue Crack Growth Phenomena in High-Strength Steel

The growth of a fatigue crack through a material is the result of a complex interaction between the applied loading, component geometry, three-dimensional constraint, load history, environment, material microstructure and several other factors. Previous studies have developed experimental and computational methods to relate the fatigue crack growth rate to many of the above conditions, with the intent of discovering some fundamental material response, i.e. crack growth rate as a function of something. Currently, the technical community uses the stress intensity factor solution as a simplistic means to relate fatigue crack growth rate to loading, geometry and all other variables. The stress intensity factor solution is a very simple linear-elastic representation of the continuum mechanics portion of crack growth. In this paper, the authors present fatigue crack growth rate data for two different high strength steel alloys generated using standard methods. The steels exhibit behaviour that appears unexplainable, compared to an aluminium alloy presented as a baseline for comparison, using the stress intensity factor solution.

Forth, Scott C.↗

Mechanical properties of high-entropy alloys with emphasis on face-centered cubic alloys

HHigh-entropy alloys (HEAs), also known as multi-principal element alloys or multi-component alloys, have been the subject of numerous investigations since they were first described in 2004. The earliest HEA was the equiatomic CrMnFeCoNi “Cantor” alloy, but HEAs now encompass a broad class of metallic and ceramic systems. The concept of utilizing the high entropy of mixing to develop stable multi-element alloys may not be scientifically correct but has produced extraordinary mechanical properties in specific HEAs, mainly CrCoNi-based alloys, associated with their continuous work-hardening rate that is sustained to large plastic strains (~0.5) and at low temperatures. This, in combination with the high frictional forces on dislocations and a propensity for twinning, leads to outstandingly high fracture toughness values (exceeding 200 MPa·m 1/2 ) and resistance to shear-band formation under dynamic loading. The critical shear strain for the onset of adiabatic shear band formation is ~7 for the Cantor alloy, much higher than that for conventional alloys, suggesting superior ballistic properties. The slower diffusion rates resulting from the multi-element environment contribute to the excellent intermediate-temperature performance. We review the principal mechanical properties of these alloys with emphasis on the face-centered cubic systems, such as the CrCoNi-based alloys. Their favorable mechanical properties and ease of processing by conventional means suggest extensive utilization in many future structural applications.

36 MATERIALS SCIENCE↗

Effect of Hot Deformation on Texture and Microstructure in Fe-Mn Austenitic Steel During Compression Loading

Hot compression tests of a new high-Mn austenitic steel were carried out at deformation temperatures of 700, 800, 900, and 1000 °C under strain rate of 0.01 s{sup −1}. The hot deformation behavior was investigated by the analyses of flow curves, texture, and deformed microstructures. Microstructures of the deformed specimens and macrotexture were examined using electron backscatter diffraction and x-ray diffraction methods, respectively. The results showed that the flow stress depended strongly on the deformation temperature and decreased by increasing deformation temperature. The microstructural evidence indicated that the dynamic recrystallization (DRX) process of experimental steel was initiated at 800 °C with necklace structure. The volume fraction of DRX grains was considerably increased by increasing deformation temperature to 1000 °C. Texture of the DRX grains tended to become a weak texture and was associated with the formation of Goss and R-Cube components. Meanwhile, martensitic transformation was detected in the hot-deformed austenite. The martensitic transformation was the most difficult in the DRX grains because of the effect of small grain size. The tendency of transformation was decreased after compression at 1000 °C.

36 MATERIALS SCIENCE↗

Quasi-Uniform High Speed Foam Crush Testing Using a Guided Drop Mass Impact

A relatively simple method for measuring the dynamic crush response of foam materials at various loading rates is described. The method utilizes a drop mass impact configuration with mass and impact velocity selected such that the crush speed remains approximately uniform during the entire sample crushing event. Instrumentation, data acquisition, and data processing techniques are presented, and limitations of the test method are discussed. The objective of the test method is to produce input data for dynamic finite element modeling involving crash and energy absorption characteristics of foam materials.

Jones, Lisa E.↗

Micron Size NaCrO 2 Particles Enable High‐loading Dry‐processed Electrode for Sodium Ion Batteries

Dry-process fabrication using fibrillatable binder is emerging as a promising method to produce high-loading electrodes for energy storage applications, favored by its cost-efficiency and eco-friendliness. While previous studies have demonstrated the advantages of dry process over the traditional slurry method, there remains a gap in understanding how the particle size of active materials influences the mechanical and electrochemical performance of dry electrodes. In this study, four different particle size NaCrO 2 materials (Average size, S-NCO: 0.6 µm, M1-NCO 1.5 µm, M2-NCO: 4.4 µm, and L-NCO: 9.9 µm) are synthesized to investigate the effect of particle size on dry-processed high-loading electrodes. The findings reveal that the larger micron-sized (>4.4 µm) NCO dry films exhibit significantly improved tensile strength and electrochemical performance, primarily ascribed to the low film porosity, abundant inter-particle connection by the binder, comprehensive carbon coverage, and efficient percolation of the conductive pathway. Notably, a full cell incorporated with a high loading (5.2 mAh cm −2 ) and high active material ratio (96.5 wt.%) L-NCO film electrode demonstrates promising cycling stability and rate capability. Furthermore, these results provide valuable insights regarding the design and fabrication of dry-processed electrodes for future energy storage applications.

25 ENERGY STORAGE↗

A trifunctional multi-walled carbon nanotubes/polyethylene glycol (MWCNT/PEG)-coated separator through a layer-by-layer coating strategy for high-energy Li–S batteries

In this study, a trifunctional separator fabricated by using a light-weight layer-by-layer multi-walled carbon nanotubes/polyethylene glycol (MWCNT/PEG) coating has been explored in lithium–sulfur (Li–S) batteries. The conductive MWCNT/PEG coating serves as (i) an upper current collector for accelerating the electron transport and benefiting the electrochemical reaction kinetics of the cell, (ii) a net-like filter for blocking and intercepting the migrating polysulfides through a synergistic effect including physical and chemical interactions, and (iii) a layered barrier for inhibiting the continuous diffusion and alleviating the volume change of the trapped active material by introducing a “buffer zone” in between the coated layers. The multi-layered MWCNT/PEG coating allows the use of the conventional pure sulfur cathode with a high sulfur content (78 wt%) and high sulfur loading (up to 6.5 mg cm -2 ) to achieve a high initial discharge capacity of 1206 mA h g -1 at C/5 rate, retaining a superior capacity of 630 mA h g -1 after 300 cycles. Lastly, the MWCNT/PEG-coated separator optimized by the facile layer-by-layer coating method provides a promising and feasible option for advanced Li–S batteries with high energy density.

25 ENERGY STORAGE↗

Modeling Electrochemical and Rheological Characteristics of Suspension-Based Electrodes for Redox Flow Cells

Flowable suspension-based electrodes (FSEs) have gained attention in recent years, as the integration of solid materials into electrochemical flow cells can offer improved performance and flexible operation. However, under conditions that engender favorable electrochemical properties (e.g., high particle loading, high conductivity, high surface area), FSEs can exhibit non-Newtonian characteristics that impose large pumping losses and flow-dependent transport rates. These multifaceted trade-offs motivate the use of models to broadly explore scaling relationships and better understand design rules for electrochemical devices. To this end, we present a one-dimensional model, integrating porous electrode theory with FSE rheology as well as flow-dependent electron and mass transport under pressure-driven flow. We study FSE behavior as a function of material properties and operating conditions, identifying key dimensionless groups that describe the underlying physical processes. We assess flow cell performance by quantifying electrode polarization and relative pumping losses, establishing generalized property-performance relationships for FSEs. Importantly, we expound relevant operating regimes—based on a subset of dimensionless groups—that inform practical operating envelopes, ultimately helping to guide FSE and cell engineering for electrochemical systems.

25 ENERGY STORAGE↗

Hydrogen gas embrittlement and the disc pressure test

A disc pressure test has been used to study the influenced of a hydrogen gas environment on the mechanical properties of three high strength superalloys, Inconel 718, L-605 and A-286, in static and dynamic conditions. The influence of the hydrogen pressure, loading rate, temperature, mechanical and thermal fatigue has investigated. The permeation characteristics of Inconel 718 have been determined in collaboration with the French AEC. The results complemented by a fractographic study are consistent either with a stress-sorption or with an internal embrittlement type of mechanism.

Bachelet, E. J.↗

Digital transmitter for data bus communications system

An improved digital transmitter for transmitting serial pulse code modulation (pcm) data at high bit rates over a transmission line is disclosed. When not transmitting, the transmitter features a high output impedance which prevents the transmitter from loading the transmission line. The pcm input is supplied to a logic control circuit which produces two discrete logic level signals which are supplied to an amplifier. The amplifier, which is transformer coupled to the output isolation circuitry, converts the discrete logic level signals to two high current level, ground isolated signals in the secondary windings of the coupling transformer. The latter signals are employed as inputs to the isolation circuitry which includes two series transistor pairs operating into a hybrid transformer functioning to isolate the transmitter circuitry from the transmission line.

Proch, G. E.↗

Influence of load interactions on crack growth as related to state of stress and crack closure

Fatigue crack propagation (FCP) after an application of a low-high loading sequence was investigated as a function of specimen thickness and crack closure. No load interaction effects were detected for specimens in a predominant plane strain state. However, for the plane stress specimens, initially high FCP rates after transition to a higher stress intensity range were observed. The difference in observed behavior was explained by examining the effect of the resulting closure stress intensity values on the effective stress intensity range.

Telesman, J.↗

Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

Lattime, Scott B.↗

Exploration Extravehicular Mobility Unit (xEMU) 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert F Marsch↗

Exploration Extravehicular Mobility Unit 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert Marsch↗

Fabrication Technologies of the High Gradient Accelerator Structures at 100MV/M Range

A CERN-SLAC-KEK collaboration on high gradient X-band structure research has been established in order to demonstrate the feasibility of the CLIC baseline design for the main linac stably operating at more than 100 MV/m loaded accelerating gradient. Several prototype CLIC structures were successfully fabricated and high power tested. They operated at 105 MV/m with a breakdown rate that meets the CLIC linear collider specifications of < 5 x 10{sup -7}/pulse/m. This paper summarizes the fabrication technologies including the mechanical design, precision machining, chemical cleaning, diffusion bonding as well as vacuum baking and all related assembly technologies. Also, the tolerances control, tuning and RF characterization will be discussed.

43 PARTICLE ACCELERATORS↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

Correlation of Tensile Deformation-Induced Strain in HSLA Steel with Residual Stress Distribution

During service, due to the dynamic loading rates encountered, structural components experience varying levels of plastic deformation which leads to changes in the mechanical behavior of materials. The dynamic loading leads to non-homogenous plastic deformation which changes the residual stress distribution. In this study, the magnitude and distribution of residual stress in tensile tested specimens of high-strength low-alloy steel were investigated using x-ray diffraction technique, by varying the deformation rate. Tensile testing was performed at four different strain rates, and residual stress measurement was done along the length of the fractured specimens. Distribution of residual stress was observed all along the length of the specimens which is attributed to the varying levels of plastic deformation. Measured residual stresses are correlated with elastic strain and plastic strain obtained from the tensile tests. Consistent decrease in the magnitude of residual stress with an increase in plastic strain is observed with decreasing strain rate at the necking region. Specimen with lower yield strength experienced higher plastic strains, hence lower elastic residual stresses. The reasons for the observed distribution of residual stress are discussed with XRD peak broadening associated with plastic deformation.