The Jimsonde - A high resolution temperature sensor.

The Jimsonde, a high-resolution lightweight temperature sensor developed for use with the FPS-16 Radar/Jimsphere wind system, and its related systems are discussed; and an error analysis that shows the sonde to have an rms error of 0.41 C at sea level and 0.56 C at 18 km is presented. Five flight tests, a sequence of four tests and one individual test, of the Jimsonde were made. For comparative purposes, radiosonde temperature data are presented along with the Jimsonde data.

Camp, D. W.↗

High resolution solar X-ray studies

Two high resolution solar X-ray payloads and their launches on Aerobee rockets with pointing system are described. The payloads included 5 to 25A X-ray spectrometers, multiaperture X-ray cameras, and command box attitude control inflight by means of a television image radioed to ground. Spatial resolution ranged from five arc minutes to ten arc seconds and spectral resolution ranged from 500 to 3000. Several laboratory tasks were completed in order to achieve the desired resolution. These included (1) development of techniques to align grid collimators, (2) studies of the spectrometric properties of crystals, (3) measurements of the absorption coefficients of various materials used in X-ray spectrometers, (4) evaluation of the performance of multiaperture cameras, and (5) development of facilities.

Blake, R. L.↗

High resolution Fourier interferometer-spectrophotopolarimeter

A high-resolution Fourier interferometer-spectrophotopolarimeter is provided using a single linear polarizer-analyzer the transmission axis azimuth of which is positioned successively in the three orientations of 0 deg, 45 deg, and 90 deg, in front of a detector; four flat mirrors, three of which are switchable to either of two positions to direct an incoming beam from an interferometer to the polarizer-analyzer around a sample cell transmitted through a medium in a cell and reflected by medium in the cell; and four fixed focussing lenses, all located in a sample chamber attached at the exit side of the interferometer. This arrangement can provide the distribution of energy and complete polarization state across the spectrum of the reference light entering from the interferometer; the same light after a fixed-angle reflection from the sample cell containing a medium to be analyzed; and the same light after direct transmission through the same sample cell, with the spectral resolution provided by the interferometer.

Fymat, A. L.↗

High resolution infrared absorptivities for gaseous chlorine nitrate

High resolution infrared absorptivities of chlorine nitrate (ClONO2) are required in order to quantitatively evaluate, by examination of infrared spectra obtained recently from balloon-borne spectrometers, the possible occurrence of this compound in the stratosphere. In the present study, infrared absorptivities for four absorption bands of gaseous ClONO2 have been measured at 0.0625 per cm spectral resolution with a Fourier transform infrared (FT-IR) system. Spectra were obtained at two pressures (0.05 and 1.05 torr) of pure ClONO2 and with 125 torr of N2 added to a 0.50 torr sample. Absorptivities for a range of spectral resolutions (0.0625, 0.125, 0.25 and 0.50 per cm) have been calculated from the data.

Graham, R. A.↗

High resolution spectrograph for the Space Telescope

The high resolution spectrograph (HRS) for ultraviolet astronomy with the Space Telescope will provide a spectral resolution of approximately 120,000 over a nominal wavelength range of 110-320 nm, together with a spatial resolution of about 0.25 arc seconds. The two detectors will consist of 512-element Digicons with cesium telluride and cesium iodide photocathodes, respectively. Photoelectrons in transit between the photocathodes and the diodes within the Digicons can be deflected in two axes with 12-bit resolution. This feature facilitates a design that emphasizes reliability since (once a hermetic seal is opened in orbit), only two moving parts, a grating carrousel and a shutter, are required for regular operation of the HRS. The instrument will be controlled by a computer in the spacecraft. The scientific objectives of the HRS investigation relate to interstellar matter in our own and nearby galaxies, physical processes of stellar mass loss and mass transfer, chemical abundances, bright quasars and Seyfert galaxy nuclei, and solar system phenomena.

Brandt, J. C.↗

Ultraviolet high-resolution spectroscopy from the Space Telescope

The High Resolution Spectrograph is one of five scientific instruments which will be part of the Space Telescope observatory. The spectrograph was designed to take advantage of the imaging and pointing capabilities of the telescope to obtain ultraviolet spectra with spectral resolution comparable to large, ground-based coudeinstruments. Some of the results of the ground-based testing program will be described, along with applications of these properties to future science programs.

Ebbets, D. C.↗

High-resolution infrared observations in IC 5146

High-resolution near-infrared and far-infrared observations are presented of the southeastern molecular cloud fragment in the IC 5146 dark cloud. These observations rule out earlier suggestions for the formation of massive stars in this fragment.

Wilking, B. A.↗

High-resolution spectrum of Cygnus X-1

A high resolution spectrum of Cygnus X-1 in the 45 to 600 keV range is presented. The measurement was made by the HEAO 3 gamma ray spectrometer during 82 days in the fall of 1979 and spring of 1980, when the source was in its normal low state. Results of a search for narrow emission lines from the source are reported. The spectrum shows no significant narrow features. The 3 delta upper limit to a narrow 511 keV annihilation line is 3 x 0.0001 photons/sq cm/s. There is also no evidence in HEAO 3 broadband data above 500 keV for the broad annihilation feature observed by HEAO 1.

Ling, J. C.↗

High-resolution surface photometry of elliptical galaxies

High-resolution CCD surface photometry profiles have been obtained for a sample of 42 nearby elliptical and SO galaxies as a first step in a program to investigate their central structure and core properties. A comparison of the present profiles to those of other observers shows that the accuracy of the central surface brightnesses is to better than 0.02 mag rms. Central resolution is limited by the atmospheric seeing PSF which is measured for each profile. A hybrid Fourier deconvolution procedure has been developed to correct the surface photometry for seeing in a model-independent way. Tests of the procedure on simulated galaxy images show that intrinsic core radii equal to the seeing FWHM or larger can be recovered from the observations. Application of the deconvolution procedure to the observed galaxies yields surface photometry profiles of slightly sub-arc second resolution.

Lauer, T. R.↗

Rarefied aerodynamics and upper atmospheric flight results from the Orbiter High Resolution Accelerometer Package experiment

Data from the High Resolution Accelerometer Package (HiRAP) experiment on the Space Shuttle Orbiter have been analyzed for 10 flights to produce lift-drag (L/D) ratios in the free molecule, transition, and continuum flow flight regimes. Freestream density is also obtained in the altitude range from 60 km to 160 km using an aerodynamic model based upon earlier flight analysis of accelerometer data. The results of the L/D analysis of the latest four flights have been compared with the aerodynamic model developed from the first six HiRAP missions. The new data agree with the established flight-derived model, thereby validating earlier analysis. However, the arithmetic mean of the 10 flight-derived L/D values in the free molecular flow regime is 0.053 (+ or - 0.1) as compared to the initial value of 0.10 (+ or - 0.3), determined from STS-6. Updates to the Orbiter aerodynamic model values and calibration factors have been incorporated into the density calculations for all 10 flights to provide realistic absolute density. The derived density altitude profiles, which have been normalized to the U.S. Standard Atmosphere 1976, are characterized by a large amplitude wave pattern relative to the standard as seen in the initial flight analysis.

Blanchard, R. C.↗

Interstellar absorption lines in high-resolution IUE spectra of cataclysmic variables

High-resolution ultraviolet spectra of five cataclysmic variables obtained with the IUE are used to investigate the character of the interstellar medium in the vicinity of the sun. These spectra reveal narrow absorption features of neutral and singly ionized interstellar species, and, in SS Cyg, narrow velocity-shifted absorption features of C IV, Si IV, and Si III. Using the column densities implied by the absorption features of the neutral and singly ionized species, values for the depletion of Si, Mg, Mn, and Fe from the gas phase of the interstellar medium in the vicinity of the sun are obtained. These hydrogen column densities are of particular importance in constraining the soft X-ray luminosity of cataclysmic variables because of the severe attenuation of the soft X-ray flux of cataclysmic variables by photoelectric absorption in the interstellar medium. In addition, using the column densities implied by the absorption features of C IV, Si IV, and Si III in the spectrum of SS Cyg, the existence of an expanding H II region of interstellar gas photoionized by he EUV and soft X-ray flux of this cataclysmic variable are inferred.

Mauche, Christopher W.↗

Water in the deep atmosphere of Venus from high-resolution spectra of the night side

High-resolution, near-infrared (1.09 to 2.5 micrometers) spectra of the night side of Venus have been obtained in 1990 and 1991 using the Fourier Transform Spectrometer at the 3.6-m Canada-France-Hawaii telescope. Absorptions due to H2O were detected in spectral windows near 2.3, 1.74, and 1.18 micrometers. Our analysis of these absorptions constrains the abundance of water vapor in three different altitude ranges located between the clouds and the surface: 30-40 km, 15-25 km and 0-15 km. A constant water vapor mixing ratio of 30 +/- 15 ppm below the clouds can fit the observations. These values are consistent with recent near-infrared studies of the night side of Venus at lower spectral resolution. The atmosphere of Venus appears to be dryer than originally suggested by the in-situ measurements made by the Pioneer Venus and Venera mass-spectrometers and gas-chromatographs.

De Bergh, C.↗

Observations of the O2 atmospheric band nightglow by the High Resolution Doppler Imager

During nighttime operation the High Resolution Doppler Imager (HRDI) on the Upper Atmosphere Research Satellite (UARS) measures both the horizontal wind field at about 94 km altitude and the limb brightness of the O2(b(sup 1) Sigma(sup +)(sub g) - Chi(cubed)Sigma(sup +)(sub g)) (0,0) atmospheric band airglow. The dominant feature of the observed emission is a latitudinal and local time dependence which is consistent with the (1,1) diurnal tidal mode. A survey of the available data set from November 1991 to July 1993 reveals a semiannual variation in the peak brightness observed at the equator, with maxima observed at the equinoxes and minima at the solstices. These results are consistent with the long-term variations in the diurnal tidal amplitudes detected in HRDI wind measurements.

Burrage, M. D.↗

NOAA's Use of High-Resolution Imagery

NOAA's use of high-resolution imagery consists of: a) Shoreline mapping and nautical chart revision; b) Coastal land cover mapping; c) Benthic habitat mapping; d) Disaster response; and e) Imagery collection and support for coastal programs.

Hund, Erik↗

Line broadening interference for high-resolution nuclear magnetic resonance spectra under inhomogeneous magnetic fields

Nuclear magnetic resonance spectroscopy serves as an important tool for analyzing chemicals and biological metabolites. However, its performance is subject to the magnetic-field homogeneity. Under inhomogeneous fields, peaks are broadened to overlap each other, introducing difficulties for assignments. Here, we propose a method termed as line broadening interference (LBI) to provide high-resolution information under inhomogeneous magnetic fields by employing certain gradients in the indirect dimension to interfere the magnetic-field inhomogeneity. The conventional spectral-line broadening is thus interfered to be non-diagonal, avoiding the overlapping among adjacent resonances. Furthermore, an inhomogeneity correction algorithm is developed based on pattern recognition to recover the high-resolution information from LBI spectra. Theoretical deductions are performed to offer systematic and detailed analyses on the proposed method. Moreover, experiments are conducted to prove the feasibility of the proposed method for yielding high-resolution spectra in inhomogeneous magnetic fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Early emission from the type IIn supernova 1998S at high resolution

The well-studied Type IIn supernova (SN IIn) 1998S is often dubbed the prototypical SN IIn, and it provides a unique opportunity to study its progenitor star from within as the supernova (SN) lights up dense circumstellar material launched from the progenitor. Here we present a Keck HIRES spectrum of SN 1998S taken within a few days after core collapse—both the earliest high-resolution (Δλ<1.0 Å) spectrum published of a SN IIn and the earliest spectrum published of SN 1998S. Modern SN studies achieve impressively short turn-around times between SN detection and the first observed spectrum, but high-resolution spectra of very young supernovae (SNe) are rare; the unique spectrum presented here provides a useful case study for observations of other young SN systems including SN 2013cu, which displayed a remarkably similar spectrum when very young. We examine the fully resolved emission-line profiles of SN 1998S, finding evidence for extreme mass loss from the progenitor at velocities much less than those characteristic of Wolf–Rayet stars. We model our high-resolution SN 1998S spectrum using the radiative-transfer code CMFGEN and explore the composition, density, and velocity gradients within the SN system. We find a mass-loss rate of 6.0×10{sup −3} M{sub ⊙} yr{sup −1} during the ∼15 years before core collapse, while other studies indicate a much lower rate at earlier times (>15 years before core collapse). A comparison with a spectrum of SN 2013cu indicates many similarities, though SN 2013cu was of Type IIb—indicating that very different supernovae can arise from progenitors with extreme mass loss in the last few years before explosion.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct observation of the intergrown {alpha}-phase in {beta}-TmAlB{sub 4} via high-resolution electron microscopy

A TmAlB{sub 4} crystal with a ThMoB{sub 4}-type ({beta}-type) structure phase related to a hexagonal AlB{sub 2}-type structure was studied by electron diffraction and high-resolution electron microscopy. A high-resolution image clearly exhibits an intergrown lamellar structure of a YCrB{sub 4}-type ({alpha}-type) phase in the matrix of the {beta}-type phase in TmAlB{sub 4} crystal. The lamellar structure can be characterized by a tiling of deformed hexagons, which are a common structure unit in the {alpha}-type and {beta}-type structures. The intergrown nanostructure is considered to be attributed to the origin of low temperature anomalies in physical properties.

36 MATERIALS SCIENCE↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.

47 OTHER INSTRUMENTATION↗