Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Impact of boron-interstitial clusters on Hall scattering factor in high-dose boron-implanted ultrashallow junctions

The Hall scattering factor r{sub H} has been determined for holes in high-dose boron-implanted ultrashallow junctions containing high concentrations of boron-interstitial clusters (BICs), combining scanning capacitance microscopy, nanospreading resistance, Hall effect, and secondary ion mass spectroscopy measurements. A value of r{sub H}=0.74{+-}0.1 has been found in reference defect-free fully activated junctions, in good agreement with the existing literature. In the case of junctions containing high concentrations of immobile and electrically inactive BICs, and independently of the implant or the annealing process, the r{sub H} value has been found to be equal to 0.95{+-}0.1. The increase in the r{sub H} value is explained in terms of the additional scattering centers associated to the presence of high concentrations of BICs.

36 MATERIALS SCIENCE↗

Effects of long pulse width and high pulsing frequency on surface superhydrophobicity of polytetrafluoroethylene in quasi-direct-current plasma immersion ion implantation

Long pulse, high frequency quasi-direct-current (dc) oxygen plasma immersion ion implantation (PIII) is utilized to create a superhydrophobic polytetrafluoroethylene (PTFE) surface with a water contact angle of over 150 deg. This technique allows the use of a high duty cycle without deleterious effects such as extensive sample heating encountered in conventional PIII. Scanning electron microscopy images review submicrometer-nanometer structures on the PTFE surface after long pulse, high frequency PIII indicative of ion implantation. On the other hand, plasma modification is the dominant effect in short pulse, low frequency PIII. Quasi-dc PIII is demonstrated to offer adjustable synergistic plasma and ion beam effects.

36 MATERIALS SCIENCE↗

Secondary phase segregation in heavily transition metal implanted ZnO

With micro-Raman spectroscopy and x-ray diffraction (XRD), we studied ZnO crystals implanted with Mn, Fe, Co, and Ni, respectively, with implantation concentrations from 4 up to 16 at. %. Using thermal treatments in air up to 700 deg. C, we analyzed the annealing effect on the ZnO crystal lattice as well as the onset of secondary phases and their microstructure on the sample surface. While the 500 deg. C treatment induces a considerable annealing, secondary phases are observed for transition metal (TM) concentrations >=8 at. % after the treatment at 700 deg. C. Their microstructure strongly depends on the TM species. Various stoichiometric and nonstoichiometric TM oxide precipitates as well as elemental TM clusters are identified by their Raman and XRD signatures and their possible magnetic impact is discussed.

36 MATERIALS SCIENCE↗

Defect Characterization in He Implanted Si

Conventional and high resolution transmission electron microscopes are used to characterize helium ion-implanted Si. 140 keV He ions were implanted into (100) Si to a fluence of 1x10{sup 17}/cm{sup 2}. After annealing at 873 K for 1 h, various linear and planar defects are formed. No He bubbles are observed. After annealing at 1223 K for 1 h, large voids and perfect dislocation loops are formed. A stress field around the voids and the spherical shape of the voids suggest the retention of He gas atoms inside the bubble.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural and optical properties of Mn-doped CdS thin films prepared by ion implantation

We report on structural and optical properties of Mn-doped CdS thin films prepared by 190 keV Mn-ion implantation at different temperatures. Mn-ion implantation in the fluence range of 1x10{sup 13}-1x10{sup 16} ions cm{sup -2} does not lead to the formation of any secondary phase. However, it induces structural disorder, causing a decrease in the optical band gap. This is addressed on the basis of band tailing due to creation of localized energy states and Urbach energy calculations. Mn-doped samples exhibit a new band in their photoluminescence spectra at 2.22 eV, which originates from the d-d({sup 4}T{sub 1}->{sup 6}A{sub 1}) transition of tetrahedrally coordinated Mn{sup 2+} ions.

36 MATERIALS SCIENCE↗

Segregation and formation of MnP particles during rapid thermal annealing of Mn-implanted InP and GaP

We have studied the structural and magnetic properties of Mn implanted (1-5x10{sup 16} cm{sup -2}, 200 keV) into InP and GaP substrates, before and after rapid thermal annealing. As revealed by Rutherford backscattering spectrometry, secondary ion mass spectrometry, and transmission electron microscopy measurements, implantation results in an amorphous surface layer 300 nm deep, and subsequent annealing gives rise to epitaxial recrystallization of this layer accompanied by a segregation of most of the Mn into clusters about 60 nm in diameter at the surface. Magnetic measurements indicate ferromagnetic behavior only for the annealed samples with T{sub C} close to 290 K, characteristic of bulk MnP, whose presence is confirmed by diffraction data. In addition, there is no evident dependence of the magnetic and structural properties on the doping type or level of the substrates.

36 MATERIALS SCIENCE↗

Influence of sputter rate and crystal orientation on the distribution of carbon in polycrystalline copper surfaces treated by plasma immersion ion implantation

The sputter rate influences the resulting thickness of the carbon containing layer within a surface that was treated by plasma immersion ion implantation. Choosing a polycrystalline substrate with rather large crystals and a material with an inherent high sputter rate, inhomogeneous distributions of carbon over the substrate area due to different thicknesses of the incorporated carbon can be detected. A correlation of three factors namely the carbon x-ray intensity in electron probe microanalysis, the thickness of the carbon layer, and the sputter rate in depth profiling measurements via secondary ion mass spectrometry can be shown. Essential for these factors is the crystal orientation that is visualized by mapping via electron backscatter diffraction. The differences in carbon content due to the orientation are most likely one of the reasons that the adhesion of diamond-like carbon films on copper does not improve with an interlayer of implanted carbon.

36 MATERIALS SCIENCE↗

Strain evolution in Si substrate due to implantation of MeV ion observed by extremely asymmetric x-ray diffraction

We studied the strain introduced in a Si(111) substrate due to MeV ion implantation using extremely asymmetric x-ray diffraction and measured the rocking curves of asymmetrical 113 diffraction for the Si substrates implanted with a 1.5 MeV Au{sup 2+} ion at fluence values of 1x10{sup 13}, 5x10{sup 13}, and 1x10{sup 14}/cm{sup 2}. The measured curves consisted of a bulk peak and accompanying subpeak with an interference fringe. The positional relationship of the bulk peak to the subpeak and the intensity variation of those peaks with respect to the wavelengths of the x rays indicated that crystal lattices near the surface were strained; the lattice spacing of surface normal (111) planes near the surface was larger than that of the bulk. Detailed strain profiles along the depth direction were successfully estimated using a curve-fitting method based on Darwin's dynamical diffraction theory. Comparing the shapes of resultant strain profiles, we found that a strain evolution rapidly occurred within a depth of approx300 nm at fluence values between 1x10{sup 13} and 5x10{sup 13}/cm{sup 2}. This indicates that formation of the complex defects progressed near the surface when the fluence value went beyond a critical value between 1x10{sup 13} and 5x10{sup 13}/cm{sup 2} and the defects brought a large strain to the substrate.

36 MATERIALS SCIENCE↗

Impact energy and retained dose uniformity in enhanced glow discharge plasma immersion ion implantation

The implantation energy and retained dose uniformity in enhanced glow discharge plasma immersion ion implantation (EGD-PIII) is investigated numerically and experimentally. Depth profiles obtained from different samples processed by EGD-PIII and traditional PIII are compared. The retained doses under different pulse widths are calculated by integrating the area under the depth profiles. Our results indicate that the improvement in the impact energy and retained dose uniformity by this technique is remarkable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomalous wear-out phenomena of europium-implanted light emitters based on a metal-oxide-semiconductor structure

The anomalous wear-out phenomena of Eu-implanted metal-oxide-semiconductor devices were investigated. It will be shown that in contrast to other rare earth elements the electroluminescence (EL) intensity of Eu-implanted SiO{sub 2} layers can rise under constant current injection before the known EL quenching will start. Under certain circumstances, this rise may amount up to two orders of magnitude. The EL behavior will be correlated with the microstructural and electrical properties of the devices. Transmission electron microscopy and Rutherford backscattering spectroscopy were applied to trace the development of Eu/Eu oxide clusters and the diffusion of Eu to the interfaces of the gate oxide layer. The hydrogen profile within the SiO{sub 2}-SiON interface region was determined by nuclear reaction analysis. Current-voltage characteristics, EL decay times, and the progression of the voltage and the EL spectrum with increasing charge injection were measured to study charge and trapping phenomena in the oxide layer to reveal details of the EL excitation mechanism. A first qualitative model for the anomalous life time behavior is proposed.

36 MATERIALS SCIENCE↗

Low-voltage nanodomain writing in He-implanted lithium niobate crystals

A scanning force microscope tip is used to write ferroelectric domains in He-implanted single-crystal lithium niobate and subsequently probe them by piezoresponse force microscopy. Investigation of cross-sections of the samples showed that the buried implanted layer, approx1 mum below the surface, is nonferroelectric and can thus act as a barrier to domain growth. This barrier enabled stable surface domains of <1 mum size to be written in 500 mum thick crystal substrates with voltage pulses of only 10 V applied to the tip.

36 MATERIALS SCIENCE↗

Simulated plasma immersion ion implantation processing of thin wires

In plasma immersion ion implantation, the dependencies of sheath expansion and ion flux density on substrate geometry are well established. However, effects of extreme diameter variations have not been investigated explicitly. Using an analytical simulation code assuming an infinite mean free path, the sheath expansion, ion flux density, and resulting substrate temperature are explored down to wire diameters of 150 {mu}m. Comparing the results for planar substrates and cylindrical, thin wires, a reduction in the sheath width up to a factor of 10, a faster establishing of a new equilibrium sheath position, and an increase in the ion fluence by a factor of 100 is encountered. The smaller plasma sheath allows for a denser packing of wires during the treatment than for planar substrates. Additionally, the implantation time is reduced, allowing a fast wire transport through the chamber, further increasing the throughput.

36 MATERIALS SCIENCE↗

Influence of annular magnet on discharge characteristics in enhanced glow discharge plasma immersion ion implantation

A permanent annular magnet positioned at the grounded anode alters the discharge characteristics in enhanced glow discharge plasma immersion ion implantation (EGD-PIII). The nonuniform magnetic field increases the electron path length and confines electron motion due to the magnetic mirror effect and electron-neutral collisions thus occur more frequently. The plasma potential and ion density measured by a Langmuir probe corroborate that ionization is improved near the grounded anode. This hybrid magnetic field EGD-PIII method is suitable for implantation of gases with low ionization rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved hydrogen ionization rate in enhanced glow discharge plasma immersion ion implantation by enlarging the interaction path using an insulating tube

A small pointed hollow anode and large tabular cathode are used in enhanced glow discharge plasma immersion ion implantation (EGD-PIII). Electrons are repelled from the substrate by the electric field formed by the negative voltage pulses and concentrate in the vicinity of the anode to enhance the self-glow discharge process. To extend the application of EGD-PIII to plasma gases with low ionization rates, an insulating tube is used to increase the interaction path for electrons and neutrals in order to enhance the discharge near the anode. Results obtained from numerical simulation based on the particle-in-cell code, finite element method, and experiments show that this configuration enhances the ionization rate and subsequent ion implant fluence. The process is especially suitable for gases that have low ionization rates such as hydrogen and helium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SEN Ultra-High Energy Implanter (UHE) Developed for Next Generation Image Sensors

The UHE is an ultra-high energy implanter developed by SEN Corporation. It was derived from the NV-GSD-HE3 by adding six RF resonators to the beam line. This extends performance so that singly charged boron ions can reach 2 MeV with beam current of 0.75 mA. The maximum energy for triple charged boron is 5 MeV with beam current of 1p{mu}A. For phosphorus ions, the UHE can accelerate doubly charged ions up to 4.4 MeV with beam current of 0.35 mA and quadruply charged ions up to 8 MeV with beam current of 1 p{mu}A. The primary application of the UHE is the image sensor market where it is used to increase the depth of CCD photodiodes into the surface of the wafer and thereby permit higher pixel density for image sensors. The second purpose is to improve productivity for relatively high boron doses at energies around 3 MeV. In order to address certain CCD defects, the system includes a state-of-the-art beam profile controller which allows optimization of implant damage and micro-uniformity. The ULE is currently used in production of high-end CCD's.

43 PARTICLE ACCELERATORS↗

Investigation into Methods to Improve Ion Source Life for Germanium Implantation

Germanium tetrafluoride has long been the standard dopant gas of choice for germanium implantation processes. While this material maintains several positive attributes (e.g., it is a nonflammable gas that is easily delivered to an ion source), its use can result in extremely short ion source lifetimes. This is especially the case for the situation when an ion implanter runs solely or predominantly GeF{sub 4}. Presented here is an examination of various potential solutions to the short source life problem, some of which enable significant improvement.

36 MATERIALS SCIENCE↗

Collimator Magnet with Functionally Defined Profile for Ion Implantation

Advanced implantation systems used for semiconductor processing should have high precision of ion beam collimation (+/-0.1 deg and better) and wide beam aperture (400 mm and more). Typical arrangements of ion implantation systems include beam scanning (BSM) and collimator magnets (CM). Standard collimator magnets have limited precision of beam collimation due to magnetic poles that have piecewise circular profile. This study proposes a novel ''constant sum angle collimator magnet''(CSACM) with non-circular magnetic pole profile. Angles of incidence {alpha}{sub i} and exit {alpha}{sub e} are defined as angles between ion trajectory and local normal to CM input/output magnetic pole edge. Profile of the CSACM is defined as having constant algebraic sum {alpha}{sub i}+{alpha}{sub e} = const for every ion trajectory of the scanned beam, in addition to ''usual'' beam collimation. An iterative procedure allows improve CSACM taking into account magnetic fringe field effects. Simulation results prove that CSACM assures precise beam collimation in two orthogonal planes. Circular approximations for CSACM magnetic poles are proposed. The model may be further developed for global design of the ion beam line (BSM+CM) and for taking into account space-charge effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evolution of Ion Implantation Technology and its Contribution to Semiconductor Industry

Industrial aspects of the evolution of ion implantation technology will be reviewed, and their impact on the semiconductor industry will be discussed. The main topics will be the technology's application to the most advanced, ultra scaled CMOS, and to power devices, as well as productivity improvements in implantation technology. Technological insights into future developments in ion-related technologies for emerging industries will also be presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗