Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Summary Statistics for TA_MH02_130827: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MH03_130827, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MC03_130806: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MC03_130806, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MC02_130701: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MC02_130701, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_ST01_130731: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_ST01_130731, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_SH02_130820: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_SH02_130820, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MT03_130730: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MT03_130730, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_SH01_130819: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_SH01_130819, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MT01_130725: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MT01_130725, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MT02_130729: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MT02_130729, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for LC_HT02_130812: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_HT02_130812, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for LC_HT01_130808: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_HT01_130808, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Core segment 15008 - Regolith stratigraphy at Apennine Front Station 2 using multispectral imaging

High precision multispectral images for Apennine Front core segment 15008 are presented. These data have a spatial resolution less than approximately 0.5 mm and are analyzed for their compositional information using image analysis techniques. The stratigraphy of the regolith sampled by 15008 is documented here as three distinct zones, the most prominent of which is a feldspathic fragment-rich zone with a chaotic fabric that occurs between 10 and 18 cm depth. It is suggested that this material is the primary rim crest deposit of the local 10 m crater. Above this zone the stratigraphy is more horizontal in nature. Below this zone the soil is observed to be relatively homogeneous with no distinctive structure to 23 cm depth.

Pieters, C. M.↗

Image-based reconstruction of three-dimensional myocardial infarct geometry for patient-specific modeling of cardiac electrophysiology

Purpose: Accurate three-dimensional (3D) reconstruction of myocardial infarct geometry is crucial to patient-specific modeling of the heart aimed at providing therapeutic guidance in ischemic cardiomyopathy. However, myocardial infarct imaging is clinically performed using two-dimensional (2D) late-gadolinium enhanced cardiac magnetic resonance (LGE-CMR) techniques, and a method to build accurate 3D infarct reconstructions from the 2D LGE-CMR images has been lacking. The purpose of this study was to address this need. Methods: The authors developed a novel methodology to reconstruct 3D infarct geometry from segmented low-resolution (Lo-res) clinical LGE-CMR images. Their methodology employed the so-called logarithm of odds (LogOdds) function to implicitly represent the shape of the infarct in segmented image slices as LogOdds maps. These 2D maps were then interpolated into a 3D image, and the result transformed via the inverse of LogOdds to a binary image representing the 3D infarct geometry. To assess the efficacy of this method, the authors utilized 39 high-resolution (Hi-res) LGE-CMR images, including 36 in vivo acquisitions of human subjects with prior myocardial infarction and 3 ex vivo scans of canine hearts following coronary ligation to induce infarction. The infarct was manually segmented by trained experts in each slice of the Hi-res images, and the segmented data were downsampled to typical clinical resolution. The proposed method was then used to reconstruct 3D infarct geometry from the downsampled images, and the resulting reconstructions were compared with the manually segmented data. The method was extensively evaluated using metrics based on geometry as well as results of electrophysiological simulations of cardiac sinus rhythm and ventricular tachycardia in individual hearts. Several alternative reconstruction techniques were also implemented and compared with the proposed method. Results: The accuracy of the LogOdds method in reconstructing 3D infarct geometry, as measured by the Dice similarity coefficient, was 82.10% ± 6.58%, a significantly higher value than those of the alternative reconstruction methods. Among outcomes of electrophysiological simulations with infarct reconstructions generated by various methods, the simulation results corresponding to the LogOdds method showed the smallest deviation from those corresponding to the manual reconstructions, as measured by metrics based on both activation maps and pseudo-ECGs. Conclusions: The authors have developed a novel method for reconstructing 3D infarct geometry from segmented slices of Lo-res clinical 2D LGE-CMR images. This method outperformed alternative approaches in reproducing expert manual 3D reconstructions and in electrophysiological simulations.

60 APPLIED LIFE SCIENCES↗

Identification of sea ice types in spaceborne synthetic aperture radar data

This study presents an approach for identification of sea ice types in spaceborne SAR image data. The unsupervised classification approach involves cluster analysis for segmentation of the image data followed by cluster labeling based on previously defined look-up tables containing the expected backscatter signatures of different ice types measured by a land-based scatterometer. Extensive scatterometer observations and experience accumulated in field campaigns during the last 10 yr were used to construct these look-up tables. The classification approach, its expected performance, the dependence of this performance on radar system performance, and expected ice scattering characteristics are discussed. Results using both aircraft and simulated ERS-1 SAR data are presented and compared to limited field ice property measurements and coincident passive microwave imagery. The importance of an integrated postlaunch program for the validation and improvement of this approach is discussed.

Kwok, Ronald↗

Segmentation, modeling and classification of the compact objects in a pile

The problem of interpreting dense range images obtained from the scene of a heap of man-made objects is discussed. A range image interpretation system consisting of segmentation, modeling, verification, and classification procedures is described. First, the range image is segmented into regions and reasoning is done about the physical support of these regions. Second, for each region several possible three-dimensional interpretations are made based on various scenarios of the objects physical support. Finally each interpretation is tested against the data for its consistency. The superquadric model is selected as the three-dimensional shape descriptor, plus tapering deformations along the major axis. Experimental results obtained from some complex range images of mail pieces are reported to demonstrate the soundness and the robustness of our approach.

Gupta, Alok↗

Advanced Real Time Optical Imaging: Part II

The first segment of this special topic, Advanced Real-time Optical Imaging: Part I (July 2018), featured a variety of studies based on techniques including hot thermocouple, particle image velocimetry, high-speed camera, infrared imaging, and environmental confocal scanning laser microscopy. Here, the papers contributed by experts in each field re-emphasized the significance of real-time optical imaging in materials science and processing. Emerging, traditional, and mixed imaging techniques were presented describing creative and innovative methods of real-time materials investigations. Part II follows the same goal as the first segment: that advanced real-time optical imaging techniques are assembled in a single venue to emphasize the diversity and strength of these approaches.

47 OTHER INSTRUMENTATION↗

Data for Clumping Index Estimation With 30°-tilted Cameras in Row Crops: Evaluation of Methods and Segment Size Effects

The clumping index (CI) quantifies the spatial distribution of foliage elements and is essential for accurately estimating the plant area index (PAI), canopy radiative transfer, and photosynthesis. Traditionally, the finite-length averaging method (LX), the gap size distribution method (CC), and a combined approach of CC and LX (CLX) have been applied to instruments like TRAC and digital hemispherical photography to estimate CI. However, a comprehensive evaluation of these methods in row crops remains limited, especially regarding the influence of segment size on CI. Meanwhile, digital cameras offer a cost-effective and user-friendly solution for canopy measurements in row crops, yet their application in this context remains underexplored. In this study, we employed a new approach using a 30°-tilted digital camera to estimate CI in corn and soybean fields, applying the LX, CC, and CLX methods. We systematically assessed the performance of these three methods by combining field measurements in real-world fields with simulations using the LESS 3D radiative transfer model. Our results showed that CLX applied to the whole image and 45° segment offered accurate estimation of CI (bias within ±0.1, RMSE < 0.2) and PAI (bias within ±0.4, RMSE < 1) in real-world fields and LESS simulations. The accuracy of the LX method was highly sensitive to segment size, with the best performance observed at the 15° segment (PAI bias within ±0.4). In contrast, the CC method remained stable across different segment sizes, and its performance was generally comparable to that of LX, except at the 15° segment. Across view zenith angles, CI derived from CC generally showed a continuous increase, while those from LX and CLX followed a rising trend at small zenith angles but began to decline at 68°, likely due to an increasing proportion of no-gap segments. Seasonally, LX tended to show decreasing CI during early growth stages but increased as the canopy matured, whereas CC and CLX showed gradually increasing CI before plateauing at peak PAI. The 30°-tilted camera effectively captured CI variations across different angles and growth stages, making it a practical and robust instrument for row crop canopy structure analysis. Applying these CI methods to digital cameras offers a low-cost and accessible CI estimation alternative, improving canopy structure monitoring accuracy in row crops.

Modeling↗

Theoretical investigation of the design and performance of a dual energy (kV and MV) radiotherapy imager

Purpose: In modern radiotherapy treatment rooms, megavoltage (MV) portal imaging and kilovoltage (kV) cone-beam CT (CBCT) imaging are performed using various active matrix flat-panel imager (AMFPI) designs. To expand the clinical utility of MV and kV imaging, MV AMFPIs incorporating thick, segmented scintillators and, separately, kV imaging using a beam’s eye view geometry have been investigated by a number of groups. Motivated by these previous studies, it is of interest to explore to what extent it is possible to preserve the benefits of kV and MV imaging using a single AMFPI design, given the considerably different x ray energy spectra used for kV and MV imaging. In this paper, considerations for the design of such a dual energy imager are explored through examination of the performance of a variety of hypothetical AMFPIs based on x ray converters employing segmented scintillators. Methods: Contrast, noise, and contrast-to-noise ratio performances were characterized through simulation modeling of CBCT imaging, while modulation transfer function, Swank factor, and signal performance were characterized through simulation modeling of planar imaging. The simulations were based on a previously reported hybrid modeling technique (accounting for both radiation and optical effects), augmented through modeling of electronic additive noise. All designs employed BGO scintillator material with thicknesses ranging from 0.25 to 4 cm and element-to-element pitches ranging from 0.508 to 1.016 mm. A series of studies were performed under both kV and MV imaging conditions to determine the most advantageous imager configuration (involving front or rear x ray illumination and use of a mirror or black reflector), converter design (pitch and thickness), and operating mode (pitch-binning combination). Results: Under the assumptions of the present study, the most advantageous imager design was found to employ rear illumination of the converter in combination with a black reflector, incorporate a BGO converter with a 0.508 mm pitch and a 2 cm thickness, and operate at full resolution for kV imaging and 2 × 2 binning mode for MV imaging. Such a dual energy imager design should provide soft tissue visualization at low, clinically practical doses under MV conditions, while helping to preserve the high spatial resolution and high contrast offered by kV imaging. Conclusions: The authors’ theoretical investigation suggests that a dual energy imager capable of largely preserving the desirable characteristics of both kV and MV imaging is feasible. Such an imager, when coupled to a dual energy radiation source, could facilitate simplification of current treatment room imaging systems (as well as their associated quality assurance), and facilitate more precise integration of kV and MV imaging information by virtue of reduced geometric uncertainties.

07 ISOTOPE AND RADIATION SOURCES↗