Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging System Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Positive/negative ion velocity mapping apparatus for electron-molecule reactions

In molecular dissociative ionization by electron collisions and dissociative electron attachment to molecule, the respective positively and negatively charged fragments are the important products. A compact ion velocity mapping apparatus is developed for the angular distribution measurements of the positive or negative fragments produced in the electron-molecule reactions. This apparatus consists of a pulsed electron gun, a set of ion velocity mapping optic lenses, a two-dimensional position detector including two pieces of micro-channel plates, and a phosphor screen, and a charge-coupled-device camera for data acquisition. The positive and negative ion detections can be simply realized by changing the voltage polarity of ion optics and detector. Velocity sliced images can be directly recorded using a narrow voltage pulse applied on the rear micro-channel plate. The efficient performance of this system is evaluated by measuring the angular distribution of O{sup -} from the electron attachments to NO at 7.3 and 8.3 eV and O{sup +} from the electron collision with CO at 40.0 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging spectroscopy diagnosis of internal electron temperature and density distributions of plasma cloud surrounding hydrogen pellet in the Large Helical Device

To investigate the behavior of hydrogen pellet ablation, a novel method of high-speed imaging spectroscopy has been used in the Large Helical Device (LHD) for identifying the internal distribution of the electron density and temperature of the plasma cloud surrounding the pellet. This spectroscopic system consists of a five-branch fiberscope and a fast camera, with each objective lens having a different narrow-band optical filter for the hydrogen Balmer lines and the background continuum radiation. The electron density and temperature in the plasma cloud are obtained, with a spatial resolution of about 6 mm and a temporal resolution of 5 Multiplication-Sign 10{sup -5} s, from the intensity ratio measured through these filters. To verify the imaging, the average electron density and temperature also have been measured from the total emission by using a photodiode, showing that both density and temperature increase with time during the pellet ablation. The electron density distribution ranging from 10{sup 22} to 10{sup 24} m{sup -3} and the temperature distribution around 1 eV have been observed via imaging. The electron density and temperature of a 0.1 m plasma cloud are distributed along the magnetic field lines and a significant electron pressure forms in the plasma cloud for typical experimental conditions of the LHD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Spot Weld Inspection using Infrared Thermography

An automated non-contact and non-destructive resistance spot weld inspection system based on infrared (IR) thermography was developed for post-weld applications. During inspection, a weld coupon was heated up by an auxiliary induction heating device from one side of the weld, while the resulting thermal waves on the other side were observed by an IR camera. The IR images were analyzed to extract a thermal signature based on normalized heating time, which was then quantitatively correlated to the spot weld nugget size. The use of normalized instead of absolute IR intensity was found to be useful in minimizing the sensitivity to the unknown surface conditions and environment interference. Application of the IR-based inspection system to different advanced high strength steels, thickness gauges and coatings were discussed.

Chen, Jian↗

Ultra-high-precision alignment of the elastomerically mounted elements of the science camera lenses for the Mars Science Laboratory (MSL) rover

Cameras built for space exploration are required to meet stringent environmental conditions, such as thermal and dynamic loads for both the optics (camera lens) and imaging electronics. On a multitude of spaceborne imaging instruments, optical elements are supported in their mounts via an elastomeric bonding approach using a room temperature vulcanizing silicone as the bonding agent. Employing this integration method, we achieved element-to-element alignment, measured as the total indicated runout, using a high-precision contact probe to be on the order of half a wavelength of He-Ne laser light, or 0.3 {mu}m, on the Malin Space Science Systems lenses for the Mars Science Laboratory (MSL) cameras. This is a higher precision than the current industry state-of-the-art, and it was achieved for the very challenging small diameter lens elements. This paper describes the design philosophy, implementation, and integration method that resulted in achieving this level of precision for interelement alignment. The results are based on actual measurements that were made during the process of building the MSL rover's science camera lenses, namely Mastcams, the Mars Hand Lens Imager, and the Mars Descent Imager. The optical designs of these cameras lenses are described in detail in [Opt. Eng.48, 103002 (2009)10.1117/1.3251343], while further information on the four science cameras can be found at http://www.msss.com.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of heating laser injection time to imploded core plasma by using x-ray framing camera

A simultaneous measurement of imploded core plasma and injection time of heating laser is conducted by using an x-ray framing camera (XFC). The experiments are performed using Gekko XII laser system for implosion of the deuterated polystyrene (CD) plastic shell target and Peta Watt (PW) laser system for heating. The time of PW laser injection is observed as the bright zone in the XFC image. The measured x-ray intensity profiles fit the Gaussian profiles well. The calculations of microchannel plate by using dynode model explain these broadened temporal profiles qualitatively. The peak position of fitted x-ray intensity profile is almost in agreement with the time when the high energy x ray is observed by x-ray streak camera. Moreover, the peak position is delayed corresponding to the delayed setting of PW laser injection time. From these results, it is concluded that we can estimate the heating laser injection time with resolution of the order of 10 ps by using XFC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Digital Image Correlation as an Experimental Modal Analysis Capability

Digital image correlation (DIC) is an established test technique in several fields including quasi-static displacement measurements. Recently there has been growing interest in using DIC to measure structural dynamic response and even extract modal parameters from that information. Although high-speed cameras have become more ubiquitous, there are no commercial end-to-end packages for modal analysis based on image data, particularly when combined with traditional data acquisition systems. As such, the practitioner is left to develop several key data processing capabilities, hardware interface equipment, and testing practices themselves. This work highlights several practical aspects that have been encountered while establishing DIC as a viable modal testing capability in a laboratory environment.

47 OTHER INSTRUMENTATION↗

CHARACTERIZING THE ATMOSPHERES OF THE HR8799 PLANETS WITH HST/WFC3

We present results from a Hubble Space Telescope (HST) program characterizing the atmospheres of the outer two planets in the HR8799 system. The images were taken over 15 orbits in three near-infrared (near-IR) medium-band filters—F098M, F127M, and F139M—using the Wide Field Camera 3. One of the three filters is sensitive to a water absorption band inaccessible from ground-based observations, providing a unique probe of the thermal emission from the atmospheres of these young giant planets. The observations were taken at 30 different spacecraft rolls to enable angular differential imaging (ADI), and the full data set was analyzed with the Karhunen–Loéve Image Projection routine, an advanced image processing algorithm adapted to work with HST data. To achieve the required high contrast at subarcsecond resolution, we utilized the pointing accuracy of HST in combination with an improved pipeline designed to combine the dithered ADI data with an algorithm designed to both improve the image resolution and accurately measure the photometry. The results include F127M (J) detections of the outer planets, HR8799b and c, and the first detection of HR8799b in the water-band (F139M) filter. The F127M photometry for HR8799c agrees well with fitted atmospheric models, resolving the longstanding difficulty in consistently modeling the near-IR flux of the planet.

79 ASTRONOMY AND ASTROPHYSICS↗

BCS (CSP Beam Characterization System) [SWR-23-13]

The Beam Characterization System (BCS) is an image-processing tool for estimating heliostat tracking errors. A large mirror, or heliostat, reflects the sun onto a distant target. A carefully calibrated camera then takes an image of this target to capture the shape of the reflected beam. The software kit hosts a series of scripts to identify key features and run analysis on the captured images.

Kesseli, Devon↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

R and DE Robotic Sensor Intern Team: Remote 3D Mapping Overview

The Department of Energy (DOE) nuclear complex includes many hazardous and challenging environments that must be inspected remotely and routinely for structural integrity evaluation and long-term planning purposes. The H-Canyon Air Exhaust (HCAEX) Tunnel biannual inspection is an example of such an environment. Presently inspections are performed by teleoperated robotic crawlers provide low resolution video feedback to the structural engineers. Advanced sensors such as Lidar and panospheric hi-res cameras have the potential to provide additional valuable data in future inspections. UT-Austin Lidar work in support of an H-Canyon deployment began with the DOE EM sponsored H-Canyon Integrated Research Project. The R and DE Robotic Sensor intern team includes two of the UT-Austin Masters students working on Lidar development to facilitate the pulling of university developed solutions to the field. The goal of this project is to develop a suite of sensors that could be used to gather advanced data in future HCAEX tunnel inspections. Of particular interest is the ability to map the tunnel walls at an accuracy that will allow for the comparison of two scans performed at different time periods to estimate the concrete erosion rate. Additionally, the development of the 3D point cloud in the GPS denied environment is the first step in being able to collect and overlay other 3D data such as radiation mapping. Project specific goals include: - Design and develop 3D mapping sensor suite. Merge Lidar point cloud with high res camera images Incorporate Inertial Measurement Unit (IMU) to assist with positioning. - Develop sensor software and user GUI Sensor data collection and integration software User GUI for reach back system. - Test solution on crawler in tunnel test bed Use crawler base similar to H-Canyon planned crawler Design and build test bed simulating tunnel conditions. To facilitate rapid sensor integration, software coding and user GUI development, the Robot Operating System (ROS) was employed as the development platform. ROS is a set of open source software libraries and tools that assist with the building of robot applications. ROS includes drivers for many sensors, state-of-the-art algorithms, and powerful developer tools. Sensors selected for the summer intern solution included assessment as to whether they possessed ROS drivers and associated sample code. Additionally, the ROS 3D Robot Visualizer (rviz) tool has been employed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cellular Neural Network for Real Time Image Processing

Since their introduction in 1988, Cellular Nonlinear Networks (CNNs) have found a key role as image processing instruments. Thanks to their structure they are able of processing individual pixels in a parallel way providing fast image processing capabilities that has been applied to a wide range of field among which nuclear fusion. In the last years, indeed, visible and infrared video cameras have become more and more important in tokamak fusion experiments for the twofold aim of understanding the physics and monitoring the safety of the operation. Examining the output of these cameras in real-time can provide significant information for plasma control and safety of the machines. The potentiality of CNNs can be exploited to this aim. To demonstrate the feasibility of the approach, CNN image processing has been applied to several tasks both at the Frascati Tokamak Upgrade (FTU) and the Joint European Torus (JET)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MO-F-CAMPUS-I-05: Radiation Dosimetry of 99mTc-IDA-D-[c(RGDfK)]2, a SPECT Agent for Angiogenesis Imaging

Purpose: Tc-99m labeled IDA-D-[c(RGDfK){sub 2} ( {sup 99m}Tc-RGD) is a recently developed radiotracer for gamma camera or single photon emission computed tomography (SPECT) imaging and promising agent for the visualization of angiogenesis. In this study, we investigated the internal radiation dosimetry of {sup 99m}Tc-RGD in humans. Methods: Six normal controls (F:M=4:2; 68.3±3.2 years; 56.5±10.7 kg) were participated in this study. Simultaneous anterior and posterior scans of whole-body were performed using dual head gamma camera system. Before the emission scan, transmission scan was performed just before injection of {sup 99m}Tc-RGD using Co-57 flood source. After an intravenous injection of 388.7±29.3 MBq of {sup 99m}Tc-RGD, six serial emission scans were performed at 0, 1, 2, 4, 8 and 24 hours post-injection. The anterior and posterior images were geometrically averaged and attenuation correction was applied using transmission scan image. Regions of interest (ROIs) were drawn on liver, gallbladder, kidneys, urinary bladder, spleen, brain, and large intestine. Time activity curves were obtained from serial emission scan and ROIs. The number of disintegrations per unit activity administered (residence time) were calculated from the area under the curve of time activity curves and injected dose of each patient. Finally, the radiation dose for each organ and effective doses were obtained using OLINDA/EXM 1.1 software and residence time. Results: High radiation doses were reported on renal and biliary excretion tracks such as urinary bladder wall, upper large intestine, kidneys, liver and gallbladder wall and their doses were 19.15±6.84, 19.28±4.78, 15.67±0.90, 9.13±1.71 and 9.09±2.03 µGy/MBq, respectively. The effective dose and effective dose equivalent were 5.08±0.53 and 7.11±0.58 µSv/MBq, respectively. Conclusion: We evaluated the radiation dose of 99mTc-RGD, which has an acceptable effective radiation dose compare to the other Tc-99m labeled radio-tracers.

60 APPLIED LIFE SCIENCES↗

Infrared observations of the quintuplet proper members using SOFIA/FORCAST and GEMINI/TReCS

Since their discovery, the Quintuplet proper members (QPMs) have been somewhat mysterious in nature. Originally dubbed the “cocoon stars” due to their cool featureless spectra, high-resolution near-infrared imaging observations have shown that at least two of the objects exhibit “pinwheel” nebulae consistent with binary systems with a carbon-rich Wolf–Rayet star and O/B companion. In this paper, we present 19.7, 25.2, 31.5, and 37.1 μm observations of the QPMs (with an angular resolution of 3.2″–3.8″) taken with the Faint Object Infrared Camera for the SOFIA Telescope (FORCAST) in conjunction with high-resolution (∼0.1″–0.2″) images at 8.8 and 11.7 μm from the Thermal-Region Camera Spectrograph (TReCS). DUSTY models of the thermal dust emission of two of the four detected QPMs, Q2 and Q3, are fitted by radial density profiles that are consistent with constant mass-loss rates (ρ{sub d}∝r{sup −2}). For the two remaining sources, Q1 and Q9, extended structures (∼1″) are detected around these objects in high-resolution imaging data. Based on the fitted dust masses, Q9 has an unusually large dust reservoir (M{sub d}=1.3{sub −0.4}{sup +0.8}×10{sup −3}M{sub ⊙}) compared to typical dusty Wolf–Rayet stars, which suggests that it may have recently undergone an episode of enhanced mass loss.

79 ASTRONOMY AND ASTROPHYSICS↗

Controllable 3D Manufacturing System

Next generation Small Modular Reactor (SMR) requires new and improved techniques, instrumentations and strategies to deal with the anticipated high radiation and high temperature environment (esp. in reactors). Component manufacturing technologies will be required that take full advantage of the new 3-D printing methods employed by additive manufacturing technologies. These manufacturing methods must be capable of producing components or sub components on a limited production basis and with nuclear quality. Based on our success in developing a variety of award-winning high energy and high power ultrafast fiber lasers and our pioneered work in fs laser 3D manufacturing (US patents, 9643361 and 9770760), PolarOnyx proposes to use tunable fiber lasers to develop smart AM & SM system to make nuclear quality components for SMR. In Phase I, we have achieved critical milestones and experimentally demonstrated the most critical functions of the proposed controllable laser AM: • Developed and investigated a series of NDI sensing technologies. Combination of IR thermal image and high resolution visible camera provides a powerful tool to characterize thermal distribution and defects. • Built an in-line laser induced breakdown spectroscopy (LIBS) to real time detect compositions of powder and parts, and melting temperature of the melting pool. It proves the LIBS is a very powerful tool to precisely guide the process. • Filed a patent (Application number 16378485) for integrating IR and visible images and LIBS for intelligent AM system. • Developed control algorithm and proved it works well for overhang experiment. • Achieved high density (>99%) and excellent mechanical properties. • Succeeded in developing a working and reliable calibration method to extract true temperature distribution during AM process. • Demonstrated spatial and temporal pulse shaping methods, and impact on microstructures. • Filed one utility patent • Laid out a solid path for phase II to work on controllable 3D manufacturing system development and optimization and to make components with nuclear quality. Our proprietary fs fiber laser based AM processing offers an ultimate solution for manufacturing high temperature components with high strength for nuclear systems. The 3D AM system in conjunction with the intelligent sensing and control is energy efficient and cost effective for the growing nuclear industries. Successful development of the proposed AM technology will provide a vital tool to solve existing and potential issues. This technology will be directly applied in the 3D printing area with combined market share of $10(s) of billions. The achievement in this research will have significant and wide social, scientific, and economic impacts by providing affordable low cost intelligent AM/SM systems, laser micromachining systems, improving energy efficiency, and reducing fabrication and operational cost. Having demonstrated the proof of concept in Phase I, we will prototype the controllable AM/SM system and investigate the efficiency and qualification of fabricating various nuclear quality components in Phase II.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spectral-domain phase microscopy with improved sensitivity using two-dimensional detector arrays

In this work we demonstrate the use of two-dimensional detectors to improve the signal-to-noise ratio (SNR) and sensitivity in spectral-domain phase microscopy for subnanometer accuracy measurements. We show that an increase in SNR can be obtained, from 82 dB to 105 dB, using 150 pixel lines of a low-cost CCD camera as compared to a single line, to compute an averaged axial scan. In optimal mechanical conditions, phase stability as small as 92 {mu}rad, corresponding to 6 pm displacement accuracy, could be obtained. We also experimentally demonstrate the benefit of spatial-averaging in terms of the reduction of signal fading due to an axially moving sample. The applications of the improved system are illustrated by imaging live cells in culture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HiCIAO: A High-contrast Instrument for the Next Generation Subaru Adaptive Optics

HiCIAO (the High-Contrast Instrument with Adaptive Optics) is a high-contrast instrument for the 8.2-meter Subaru Telescope. The instrument is a near-infrared camera which benefits from a new adaptive optics (AO) system on the Subaru Telescope (AO188). The instrument realizes the high contrast with a help of AO188, a classical Lyot coronagraph, and three differential imaging techniques (polarimetric, spectral, and angular). Besides the differential imaging modes, HiCIAO also offers a normal imaging mode which covers 20''x20'' FOV with 0.''01 pixel{sup -1} resolution, and a pupil viewing mode for a precise alignment of the Lyot stop on the pupil image. The expected contrasts are 10{sup 5.5} at 1.''0 separation and 10{sup 4} at 0.''1 separation from a central star in the spectral differential imaging mode. The instrument is currently in its commissioning phase after the first-light observation in December 2008. This paper is an introductory review of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of fast (sub-minute) micro-tomography

An x-ray fast micro-tomography system was developed at medical and imaging beamline BL20B2 in SPring-8. We attempted a 'continuous rotation method' whereby the sample keeps rotating in the beam during the measurement. The image acquisitions are synchronized with the trigger pulses branched from the stepper motor controller. An electron multiplier (EM)-CCD camera (C9100-02, 1000x1000 pixels, 30 fps, 8 {mu}m/pixel, Hamamatsu Photonics) and beam-monitor AA40P (Hamamatsu Photonics) were used as an image detector. The effective pixel size of the detector was 4.9 {mu}m/pixel and the spatial resolution was about 15 {mu}m. The total measurement time for 900 projections has been reduced to 36 s. The reconstruction time was also reduced using GPGPU and SSD system. Using these techniques, preliminary experiment for 4-D (time resolved 3-D) micro-imaging has also been performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Dark Energy Survey Data Processing and Calibration System

The Dark Energy Survey (DES) is a 5000 deg2 grizY survey reaching characteristic photometric depths of 24th magnitude (10 sigma) and enabling accurate photometry and morphology of objects ten times fainter than in SDSS. Preparations for DES have included building a dedicated 3 deg2 CCD camera (DECam), upgrading the existing CTIO Blanco 4m telescope and developing a new high performance computing (HPC) enabled data management system (DESDM). The DESDM system will be used for processing, calibrating and serving the DES data. The total data volumes are high (~2PB), and so considerable effort has gone into designing an automated processing and quality control system. Special purpose image detrending and photometric calibration codes have been developed to meet the data quality requirements, while survey astrometric calibration, coaddition and cataloging rely on new extensions of the AstrOmatic codes which now include tools for PSF modeling, PSF homogenization, PSF corrected model fitting cataloging and joint model fitting across multiple input images. The DESDM system has been deployed on dedicated development clusters and HPC systems in the US and Germany. An extensive program of testing with small rapid turn-around and larger campaign simulated datasets has been carried out. The system has also been tested on large real datasets, including Blanco Cosmology Survey data from the Mosaic2 camera. In Fall 2012 the DESDM system will be used for DECam commissioning, and, thereafter, the system will go into full science operations.

79 ASTRONOMY AND ASTROPHYSICS↗