Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

First-principles simulation of light-ion microscopy of graphene

The extreme sensitivity of 2D materials to defects and nanostructure requires precise imaging techniques to verify presence of desirable and absence of undesirable features in the atomic geometry. Helium-ion beams have emerged as a promising materials imaging tool, achieving up to 20 times higher resolution and 10 times larger depth-of-field than conventional or environmental scanning electron microscopes. Here, we offer first-principles theoretical insights to advance ion-beam imaging of atomically thin materials by performing real-time time-dependent density functional theory simulations of single impacts of 10–200 keV light ions in free-standing graphene. Here we predict that detecting electrons emitted from the back of the material (the side from which the ion exits) would result in up to three times higher signal and up to five times higher contrast images, making 2D materials especially compelling targets for ion-beam microscopy. This predicted superiority of exit-side emission likely arises from anisotropic kinetic emission. The charge induced in the graphene equilibrates on a sub-fs time scale, leading to only slight disturbances in the carbon lattice that are unlikely to damage the atomic structure for any of the beam parameters investigated here.

36 MATERIALS SCIENCE↗

Anatomical noise in contrast-enhanced digital mammography. Part II. Dual-energy imaging

Purpose: Dual-energy (DE) contrast-enhanced digital mammography (CEDM) uses an iodinated contrast agent in combination with digital mammography (DM) to evaluate lesions on the basis of tumor angiogenesis. In DE imaging, low-energy (LE) and high-energy (HE) images are acquired after contrast administration and their logarithms are subtracted to cancel the appearance of normal breast tissue. Often there is incomplete signal cancellation in the subtracted images, creating a background “clutter” that can impair lesion detection. This is the second component of a two-part report on anatomical noise in CEDM. In Part I the authors characterized the anatomical noise for single-energy (SE) temporal subtraction CEDM by a power law, with model parameters α and β. In this work the authors quantify the anatomical noise in DE CEDM clinical images and compare this with the noise in SE CEDM. The influence on the anatomical noise of the presence of iodine in the breast, the timing of imaging postcontrast administration, and the x-ray energy used for acquisition are each evaluated.Methods: The power law parameters, α and β, were measured from unprocessed LE and HE images and from DE subtracted images to quantify the anatomical noise. A total of 98 DE CEDM cases acquired in a previous clinical pilot study were assessed. Conventional DM images from 75 of the women were evaluated for comparison with DE CEDM. The influence of the imaging technique on anatomical noise was determined from an analysis of differences between the power law parameters as measured in DM, LE, HE, and DE subtracted images for each subject.Results: In DE CEDM, weighted image subtraction lowers β to about 1.1 from 3.2 and 3.1 in LE and HE unprocessed images, respectively. The presence of iodine has a small but significant effect in LE images, reducing β by about 0.07 compared to DM, with α unchanged. Increasing the x-ray energy, from that typical in DM to a HE beam, significantly decreases α by about 2 × 10{sup −5} mm{sup 2}, and lowers β by about 0.14 compared to LE images. A comparison of SE and DE CEDM at 4 min postcontrast shows equivalent power law parameters in unprocessed images, and lower α and β by about 3 × 10{sup −5} mm{sup 2} and 0.50, respectively, in DE versus SE subtracted images.Conclusions: Image subtraction in both SE and DE CEDM reduces β by over a factor of 2, while maintaining α below that in DM. Given the equivalent α between SE and DE unprocessed CEDM images, and the smaller anatomical noise in the DE subtracted images, the DE approach may have an advantage over SE CEDM. It will be necessary to test this potential advantage in future lesion detectability experiments, which account for realistic lesion signals. The authors' results suggest that LE images could be used in place of DM images in CEDM exam interpretation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic Imaging in the Medical Support of the Future Missions to the Moon

This viewgraph presentation is a course that reviews the diagnostic imaging techniques available for medical support on the future moon missions. The educational objectives of the course are to: 1) Update the audience on the curreultrasound imaging in space flight; 2) Discuss the unique aspects of conducting ultrasound imaging on ISS, interplanetary transit, ultrasound imaging on ISS, interplanetary transit, and lunar surface operations; and 3) Review preliminary data obtained in simulations of medical imaging in lunar surface operations.

Sargsyan, Ashot E.↗

Detection of Objects Hidden in Highly Scattering Media Using Time-Gated Imaging Methods

Non-intrusive and non-invasive optical imaging techniques has generated great interest among researchers for their potential applications to biological study, device characterization, surface defect detection, and jet fuel dynamics. Non-linear optical parametric amplification gate (NLOPG) has been used to detect back-scattered images of objects hidden in diluted Intralipid solutions. To directly detect objects hidden in highly scattering media, the diffusive component of light needs to be sorted out from early arrived ballistic and snake photons. In an optical imaging system, images are collected in transmission or back-scattered geometry. The early arrival photons in the transmission approach, always carry the direct information of the hidden object embedded in the turbid medium. In the back-scattered approach, the result is not so forth coming. In the presence of a scattering host, the first arrival photons in back-scattered approach will be directly photons from the host material. In the presentation, NLOPG was applied to acquire time resolved back-scattered images under the phase matching condition. A time-gated amplified signal was obtained through this NLOPG process. The system's gain was approximately 100 times. The time-gate was achieved through phase matching condition where only coherent photons retain their phase. As a result, the diffusive photons, which were the primary contributor to the background, were removed. With a large dynamic range and high resolution, time-gated early light imaging has the potential for improving rocket/aircraft design by determining jets shape and particle sizes. Refinements to these techniques may enable drop size measurements in the highly scattering, optically dense region of multi-element rocket injectors. These types of measurements should greatly enhance the design of stable, and higher performing rocket engines.

Galland, Pierre A.↗

Single-Filament Imaging Mass Spectrometry Lipidomics in Arthrospira platensis

Elucidating intra-organismal biochemical and lipid organization in photosynthetic biological cell factories of filamentous cyanobacteria, i.e., Arthrospira platensis (Spirulina), is important to track physiological response mechanisms during growth. Little is known about the filaments' biochemical organization and cellular structure and no label-free imaging techniques exist that provide molecular mapping. We applied ultra-high resolution mass spectrometry (7T FT-ICR-MS) matrix-assisted laser desorption ionization (MALDI) imaging to immobilized Spirulina filaments to investigate the localization of lipids across distinct physiological regions. We optimized matrix selection and deposition methods with the goal of facilitating high spatial, and intra-filament, resolution using untargeted multivariate statistical spectral deconvolution across MS pixels. Our results demonstrate an improved two step application with an optimized procedure for intra-organismal lipid profiling to improve analyte sensitivity and achieve higher spatial resolution, whereby we evaluate three conventional matrices 2,5-dihydroxybenzoic acid (DHB), a 9:1 ratio of DHB:superDHB (sDHB), 1,5- diaminonaphthalene (DAN) and a 50:50 mix of DHB:sDHB and compare delineation and pixel-based elucidation of intra-filament lipidomics. We identified a total of 1,626 features that could be putatively assigned a lipid-like formula based on database query and 46 unique features, with associated lipid assignments that were significantly distinct in their intra-filament location. MALDI- imaging MS with untargeted statistical spectral deconvolution was used to visualize intra-filament lipidomics organization in Spirulina filaments. Improvements in matrix deposition, including sequential sublimation and pneumatic spraying, increased signal abundance at high spatial resolution and allowed for identification of distinct lipid composition regions. Here in this work outlines a methodology that may be used for micro-ecological untargeted molecular phenotyping.

09 BIOMASS FUELS↗

Reflection type of terahertz imaging system using a high-T{sub c} superconducting oscillator

A reflection type of imaging system is shown at sub-terahertz frequencies generated from high-T{sub c} superconducting intrinsic Josephson junction mesa structures fabricated by single crystalline Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+δ} to demonstrate how the sub-terahertz imaging technique using monochromatic radiation is powerful and unique for the variety of practical applications. Several examples are discussed in detail and are compared to other terahertz imaging systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-J-06: A Feasibility Study On Clinical Implementation of 4D-CBCT in Lung Cancer Treatment

Purpose: Four-dimensional cone-beam CT (4D-CBCT) is a novel imaging technique to setup patients with pulmonary lesions in radiation therapy. This paper is to perform a feasibility study on the implementation of 4D-CBCT as image guidance for (1) SBRT and (2) Low Modulation (Low-Mod) IMRT in lung cancer treatment. Methods: Image artifacts and observers variability are evaluated by analyzing the 4D-CT QA phantom and patient 4D image data. There are two 4D-CBCT image artifacts: (1) Spatial artifact caused by the patient irregular breathing pattern will generate blurring and anatomy gap/overlap; (2) Cone beam scattering and hardening artifact will affect the image spatial and contrast resolution. The couch shift varies between 1mm to 3mm from different observers during the 4D-CBCT registration. Breath training is highly recommended to improve the respiratory regularity during CT simulation and treatment, especially for SBRT. Elekta XVI 4.5 Symmetry protocol is adopted in the patient 4DCBCT scanning and intensity-based registration. Physician adjustments on the auto-registration are involved prior to the treatment. Physician peer review on 4D-CBCT image acquisition and registration is also recommended to reduce the inter-observer variability. The average 4D-CT in reference volume coordinates is exported to MIM Vista 5.6.2 to manually fuse to the planning CT for further evaluation. Results: (1) SBRT: 4DCBCT is performed in dry-run and in each treatment fraction. Image registration and couch shift are reviewed by another physician on the 1st fraction before the treatment starts. (2) Low-Mod IMRT: 4D-CBCT is performed and peer reviewed on weekly basis. Conclusion: 4D-CBCT in SBRT dry-run can discover the ITV discrepancies caused by the low quality 4D-CT simulation. 4D-CBCT during SBRT and Low-Mod IMRT treatment provides physicians more confidence to target lung tumor and capability to evaluate inter-fractional ITV changes. More advanced 4D-CBCT scan protocol and reconstruction algorithm may be needed in the future.

60 APPLIED LIFE SCIENCES↗

Identification of Presolar Spinel Grains from a Murray Residue by Multi-Detection Raster Imaging

Grain size separate CG from the Murray CM2 carbonaceous chondrite contains mostly spinel grains of average diameter 0.5 m. Zinner et al. found that approximately 1% of these spinel grains are of presolar origin as determined by their large O isotopic anomalies. These O isotopic measurements were made with the NanoSIMS on individual grains that were well separated from one another on a gold foil. The grains were selected for analysis from secondary electron and secondary O-16(-) images. The primary beam was then successively deflected onto these single grains for O isotopic analysis. While single grain analysis on dispersed samples is effective for finding relatively abundant anomalous grains, ion imaging in a raster mode on tightly packed grains might be more efficient for locating few anomalous grains among predominantly isotopically normal grains. In fact, this was the analysis mode used by Messenger et al. to discover presolar silicates in interplanetary dust particles. In an exploratory effort that is also geared toward establishing the optimum isotopic imaging technique in the search for presolar silicate grains in primitive meteorites, we measured O isotopic ratios in spinel grains from the Murray CG separate by raster imaging of areas with more or less tightly packed grains.

Nguyen, A.↗

Quantitative Phase Fraction Detection in Organic Photovoltaic Materials through EELS Imaging

Organic photovoltaic materials have recently seen intense interest from the research community. Improvements in device performance are occurring at an impressive rate; however, visualization of the active layer phase separation still remains a challenge. Our paper outlines the application of two electron energy-loss spectroscopic (EELS) imaging techniques that can complement and enhance current phase detection techniques. Specifically, the bulk plasmon peak position, often used to produce contrast between phases in energy filtered transmission electron microscopy (EFTEM), is quantitatively mapped across a sample cross section. One complementary spectrum image capturing the carbon and sulfur core loss edges is compared with the plasmon peak map and found to agree quite well, indicating that carbon and sulfur density differences between the two phases also allows phase discrimination. Additionally, an analytical technique for determining absolute atomic areal density is used to produce an absolute carbon and sulfur areal density map. We also show how these maps may be re-interpreted as a phase ratio map, giving quantitative information about the purity of the phases within the junction.

14 SOLAR ENERGY↗

6 nm super-resolution optical transmission and scattering spectroscopic imaging of carbon nanotubes using a nanometer-scale white light source

Abstract Optical transmission and scattering spectroscopic microscopy at the visible and adjacent wavelengths denote one of the most informative and inclusive characterization methods in material research. Unfortunately, restricted by the diffraction limit of light, it cannot resolve the nanoscale variation in light absorption and scattering, diagnostics of the local inhomogeneity in material structure and properties. Moreover, a large quantity of nanomaterials has anisotropic optical properties that are appealing yet hard to characterize through conventional optical methods. There is an increasing demand to extend the optical hyperspectral imaging into the nanometer length scale. In this work, we report a super-resolution hyperspectral imaging technique that uses a nanoscale white light source generated by superfocusing the light from a tungsten-halogen lamp to simultaneously obtain optical transmission and scattering spectroscopic images. A 6-nm spatial resolution in the visible to near-infrared wavelength regime (415–980 nm) is demonstrated on an individual single-walled carbon nanotube (SW-CNT). Both the longitudinal and transverse optical electronic transitions are measured, and the SW-CNT chiral indices can be identified. The band structure modulation in a SW-CNT through strain engineering is mapped.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sparse-Data Deep Learning Strategies for Radiographic Non-Destructive Testing

Radiography is an imaging technique used in a variety of applications, such as medical diagnosis, airport security, and nondestructive testing. We present a deep learning system for extracting information from radiographic images. We perform various prediction tasks using our system, including material classification and regression on the dimensions of a given object that is being radiographed. Our system is designed to address the sparse-data issue for radiographic nondestructive testing applications. It uses a radiographic simulation tool for synthetic data augmentation, and it uses transfer learning with a pre-trained convolutional neural network model. Using this system, our preliminary results indicate that the object geometry regression task saw an improvement of 70% in the R-squared value when using a multi-regime model. In addition, we increase the performance of the object material classification tasks by utilizing data from different imaging systems. In particular, using neutron imaging improved the material classification accuracy by 20% when compared to x-ray imaging.

convolutional neural networks↗

Confined hyperbolic metasurface modes for structured illumination microscopy

Plasmonic hyperbolic metasurfaces have emerged as an effective platform for manipulating the propagation of light. Here, confined modes on arrays of silver nanoridges that exhibit hyperbolic dispersion are used to demonstrate and model a super-resolution imaging technique based on structured illumination microscopy. A spatial resolution of ∼75 nm at 458 nm is demonstrated, which is 3.1 times better than an equivalent diffraction limited image. This work emphasizes the ability to engineer the properties of confined optical modes and to leverage those characteristics for applications in imaging. The results of this work could lead to improved approaches for super-resolution imaging using designed sub-wavelength structures.

42 ENGINEERING↗

Analytical study of acousto/optical holography-interfacing methods for acoustical and optical holography NDT research

The international status of the art of acousto optical imaging techniques adaptable to nondestructive testing and, interfacing methods for acoustical and optical holography in nondestructive testing research are studied. Evaluation of 20 different techniques encompassed investigation of varieties of detectors and detection schemes, all of which are described and summarized. Related investigation is reported in an Appendix. Important remarks on image quality, factors to be considered in designing a particular system, and conclusions and recommendations are presented. Three bibliographies are included.

El-Sum, H. M. A.↗

Intracellular in situ labeling of TiO 2 nanoparticles for fluorescence microscopy detection

Titanium dioxide (TiO 2 ) nanoparticles are produced for many different purposes, including development of therapeutic and diagnostic nanoparticles for cancer detection and treatment, drug delivery, induction of DNA double-strand breaks, and imaging of specific cells and subcellular structures. Currently, the use of optical microscopy, an imaging technique most accessible to biology and medical pathology, to detect TiO 2 nanoparticles in cells and tissues ex vivo is limited with low detection limits, while more sensitive imaging methods (transmission electron microscopy, X-ray fluorescence microscopy, etc.) have low throughput and technical and operational complications. In this paper, we describe two in situ posttreatment labeling approaches to stain TiO 2 nanoparticles taken up by the cells. The first approach utilizes fluorescent biotin and fluorescent streptavidin to label the nanoparticles before and after cellular uptake; the second approach is based on the copper-catalyzed azide-alkyne cycloaddition, the so-called Click chemistry, for labeling and detection of azide-conjugated TiO 2 nanoparticles with alkyneconjugated fluorescent dyes such as Alexa Fluor 488. To confirm that optical fluorescence signals of these nanoparticles match the distribution of the Ti element, we used synchrotron X-ray fluorescence microscopy (XFM) at the Advanced Photon Source at Argonne National Laboratory. Titanium-specific XFM showed excellent overlap with the location of optical fluorescence detected by confocal microscopy. Finally and therefore, future experiments with TiO 2 nanoparticles may safely rely on confocal microscopy after in situ nanoparticle labeling using approaches described here.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Direct Visualization of Aggregate Morphology and Dynamics in a Model Soil Organic–Mineral System

Interactions between mineral surfaces and organic matter are ubiquitous in soils and the environment. Through both physical and chemical mechanisms, organic-mineral assemblages prevent decomposition of soil organic matter by limiting accessibility or reducing efficacy of enzymes and microbes. To understand the mechanisms underlying organic-mineral interactions, researchers have begun to interrogate these systems at smaller length scales. Current techniques that maintain a hydrated state and allow researchers to characterize nanometer length scales are limited. Here we chose a model organic-mineral system and performed complementary imaging techniques that enable direct nanoscale observations in environmentally relevant conditions: cryogenic TEM and in-situ liquid cell TEM. We observed a three-fold increase in aggregate size of goethite nanoparticles upon addition of a model organic phosphate ligand and quantification of nanoparticle orientation reveals a preference for side-to-side interactions independent of the addition of an organic ligand. Additionally, in-situ liquid cell TEM experiments provides a dynamic view of the interactions allowing us to report velocities of mineral assemblages during aggregation and disaggregation, which could potentially provide binding energetics and kinetic parameters about organic-mineral and mineral-mineral systems.

cryo TEM↗

Photodissociation of van der Waals clusters of isoprene with oxygen, C{sub 5}H{sub 8}-O{sub 2}, in the wavelength range 213-277 nm

The speed and angular distribution of O atoms arising from the photofragmentation of C{sub 5}H{sub 8}-O{sub 2}, the isoprene-oxygen van der Waals complex, in the wavelength region of 213-277 nm has been studied with the use of a two-color dissociation-probe method and the velocity map imaging technique. Dramatic enhancement in the O atoms photo-generation cross section in comparison with the photodissociation of individual O{sub 2} molecules has been observed. Velocity map images of these 'enhanced' O atoms consisted of five channels, different in their kinetic energy, angular distribution, and wavelength dependence. Three channels are deduced to be due to the one-quantum excitation of the C{sub 5}H{sub 8}-O{sub 2} complex into the perturbed Herzberg III state ({sup 3}{Delta}{sub u}) of O{sub 2}. This excitation results in the prompt dissociation of the complex giving rise to products C{sub 5}H{sub 8}+O+O when the energy of exciting quantum is higher than the complex photodissociation threshold, which is found to be 41740 {+-} 200 cm{sup -1} (239.6{+-}1.2 nm). This last threshold corresponds to the photodissociation giving rise to an unexcited isoprene molecule. The second channel, with threshold shifted to the blue by 1480 {+-} 280 cm{sup -1}, corresponds to dissociation with formation of rovibrationally excited isoprene. A third channel was observed at wavelengths up to 243 nm with excitation below the upper photodissociation threshold. This channel is attributed to dissociation with the formation of a bound O atom C{sub 5}H{sub 8}-O{sub 2}+hv{yields} C{sub 5}H{sub 8}-O{sub 2}({sup 3}{Delta}{sub u}) {yields} C{sub 5}H{sub 8}O + O and/or to dissociation of O{sub 2} with borrowing of the lacking energy from incompletely cooled complex internal degrees of freedom C{sub 5}H{sub 8}{sup *}-O{sub 2}+hv{yields} C{sub 5}H{sub 8}{sup *}-O{sub 2}({sup 3}{Delta}{sub u}) {yields} C{sub 5}H{sub 8}+ O + O. The kinetic energy of the O atoms arising in two other observed channels corresponds to O atoms produced by photodissociation of molecular oxygen in the excited a {sup 1}{Delta}{sub g} and b {sup 1}{Sigma}{sub g}{sup +} singlet states as the precursors. This indicates the formation of singlet oxygen O{sub 2}(a {sup 1}{Delta}{sub g}) and O{sub 2}(b {sup 1}{Sigma}{sub g}{sup +}) after excitation of the C{sub 5}H{sub 8}-O{sub 2} complex. Cooperative excitation of the complex with a simultaneous change of the spin of both partners {sup 1}X-{sup 3}O{sub 2}+h{nu}{yields}{sup 3}X-{sup 1}O{sub 2}{yields}{sup 3}X +{sup 1}O{sub 2} is suggested as a source of singlet oxygen O{sub 2}(a {sup 1}{Delta}{sub g}) and O{sub 2}(b {sup 1}{Sigma}{sub g}{sup +}). This cooperative excitation is in agreement with little or no vibrational excitation of O{sub 2}(a {sup 1}{Delta}{sub g}), produced from the C{sub 5}H{sub 8}-O{sub 2} complex as studied in the current paper as well as from the C{sub 3}H{sub 6}-O{sub 2} and CH{sub 3}I-O{sub 2} complexes reported in our previous paper [Baklanov et al., J. Chem. Phys. 126, 124316 (2007)]. The formation of O{sub 2}(a {sup 1}{Delta}{sub g}) from C{sub 5}H{sub 8}-O{sub 2} was observed at {lambda}{sub pump}= 213-277 nm with the yield going down towards the long wavelength edge of this interval. This spectral profile is interpreted as the red-side wing of the band of a cooperative transition {sup 1}X-{sup 3}O{sub 2}+h{nu}{yields}{sup 3}X(T{sub 2})-{sup 1}O{sub 2}(a {sup 1}{Delta}{sub g}) in the C{sub 5}H{sub 8}-O{sub 2} complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron imaging experiments at E-12 beam-line of CIRUS

Neutron imaging beam-line at E-12 beam port of CIRUS reactor India has been developed to implement Neutron tomography, phase contrast imaging and dynamic imaging techniques for various applications. Several experiments on these techniques have been carried out successfully. Neutron radiography and tomography has been used to study blisters formation in pressure tube along with many other applications. Similarly phase contrast imaging has been used to study its feasibility for better contrast in radiographic images. Dynamic imaging has been applied to study the melting of pure and impure lead under heat. In this paper we report the details of various experiments performed at this beam-line.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Mast Cameras and Mars Descent Imager (MARDI) for the 2009 Mars Science Laboratory

Based on operational experience gained during the Mars Exploration Rover (MER) mission, we proposed and were selected to conduct two related imaging experiments: (1) an investigation of the geology and short-term atmospheric vertical wind profile local to the Mars Science Laboratory (MSL) landing site using descent imaging, and (2) a broadly-based scientific investigation of the MSL locale employing visible and very near infra-red imaging techniques from a pair of mast-mounted, high resolution cameras. Both instruments share a common electronics design, a design also employed for the MSL Mars Hand Lens Imager (MAHLI) [1]. The primary differences between the cameras are in the nature and number of mechanisms and specific optics tailored to each camera s requirements.

Malin, M. C.↗