Search NASA⌕ Search

SEARCH · Search NASA

Results for “Importance Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

A new long-term sampling approach to viruses on surfaces

The importance of virus disease outbreaks and its prevention is of growing public concern but our understanding of virus transmission routes is limited by adequate sampling strategies. While conventional swabbing methods provide merely a microbial snapshot, an ideal sampling strategy would allow reliable collection of viral genomic data over longer time periods. This study has evaluated a new, paper-based sticker approach for collection of reliable viral genomic data over longer time periods up to 14 days and after implementation of different hygiene measures. In contrast to swabbing methods, which sample viral load present on a surface at a given time, the paper-based stickers are attached to the surface area of interest and collect viruses that would have otherwise been transferred onto that surface. The major advantage of one-side adhesive stickers is that they are permanently attachable to a variety of surfaces. Initial results demonstrate that stickers permit stable recovery characteristics, even at low virus titers. Stickers also allow reliable virus detection after implementation of routine hygiene measures and over longer periods up to 14 days. Overall, results for this new sticker approach for virus genomic data collection are encouraging, but further studies are required to confirm anticipated benefits over a range of virus types.

59 BASIC BIOLOGICAL SCIENCES↗

A sub-sampled approach to extremely low-dose STEM

The inpainting of deliberately and randomly sub-sampled images offers a potential means to image specimens at a high resolution and under extremely low-dose conditions (≤1 e - /Å 2 ) using a scanning transmission electron microscope. We show that deliberate sub-sampling acquires images at least an order of magnitude faster than conventional low-dose methods for an equivalent electron dose. More importantly, when adaptive sub-sampling is implemented to acquire the images, there is a significant increase in the resolution and sensitivity which accompanies the increase in imaging speed. Lastly, we demonstrate the potential of this method for beam sensitive materials and in-situ observations by experimentally imaging the node distribution in a metal-organic framework.

47 OTHER INSTRUMENTATION↗

Multivariate Methods for Prediction of Geologic Sample Composition with Laser-Induced Breakdown Spectroscopy

Laser-induced breakdown spectroscopy (LIBS) uses pulses of laser light to ablate a material from the surface of a sample and produce an expanding plasma. The optical emission from the plasma produces a spectrum which can be used to classify target materials and estimate their composition. The ChemCam instrument on the Mars Science Laboratory (MSL) mission will use LIBS to rapidly analyze targets remotely, allowing more resource- and time-intensive in-situ analyses to be reserved for targets of particular interest. ChemCam will also be used to analyze samples that are not reachable by the rover's in-situ instruments. Due to these tactical and scientific roles, it is important that ChemCam-derived sample compositions are as accurate as possible. We have compared the results of partial least squares (PLS), multilayer perceptron (MLP) artificial neural networks (ANNs), and cascade correlation (CC) ANNs to determine which technique yields better estimates of quantitative element abundances in rock and mineral samples. The number of hidden nodes in the MLP ANNs was optimized using a genetic algorithm. The influence of two data preprocessing techniques were also investigated: genetic algorithm feature selection and averaging the spectra for each training sample prior to training the PLS and ANN algorithms. We used a ChemCam-like laboratory stand-off LIBS system to collect spectra of 30 pressed powder geostandards and a diverse suite of 196 geologic slab samples of known bulk composition. We tested the performance of PLS and ANNs on a subset of these samples, choosing to focus on silicate rocks and minerals with a loss on ignition of less than 2 percent. This resulted in a set of 22 pressed powder geostandards and 80 geologic samples. Four of the geostandards were used as a validation set and 18 were used as the training set for the algorithms. We found that PLS typically resulted in the lowest average absolute error in its predictions, but that the optimized MLP ANN and the CC ANN often gave results comparable to PLS. Averaging the spectra for each training sample and/or using feature selection to choose a small subset of wavelengths to use for predictions gave mixed results, with degraded performance in some cases and similar or slightly improved performance in other cases. However, training time was significantly reduced for both PLS and ANN methods by implementing feature selection, making this a potentially appealing method for initial, rapid-turn-around analyses necessary for Chemcam's tactical role on MSL. Choice of training samples has a strong influence on the accuracy of predictions. We are currently investigating the use of clustering algorithms (e.g. k-means, neural gas, etc.) to identify training sets that are spectrally similar to the unknown samples that are being predicted, and therefore result in improved predictions

Morris, Richard↗

230Th-234U Model-Ages of Some Uranium Standard Reference Materials

The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Preliminary Examination of the Interstellar Collector of Stardust

The findings of the Stardust spacecraft mission returned to earth in January 2006 are discussed. The spacecraft returned two unprecedented and independent extraterrestrial samples: the first sample of a comet and the first samples of contemporary interstellar dust. An important lesson from the cometary Preliminary Examination (PE) was that the Stardust cometary samples in aerogel presented a technical challenge. Captured particles often separate into multiple fragments, intimately mix with aerogel and are typically buried hundreds of microns to millimeters deep in the aerogel collectors. The interstellar dust samples are likely much more challenging since they are expected to be orders of magnitudes smaller in mass, and their fluence is two orders of magnitude smaller than that of the cometary particles. The goal of the Stardust Interstellar Preliminary Examination (ISPE) is to answer several broad questions, including: which features in the interstellar collector aerogel were generated by hypervelocity impact and how much morphological and trajectory information may be gained?; how well resolved are the trajectories of probable interstellar particles from those of interplanetary origin?; and, by comparison to impacts by known particle dimensions in laboratory experiments, what was the mass distribution of the impacting particles? To answer these questions, and others, non-destructive, sequential, non-invasive analyses of interstellar dust candidates extracted from the Stardust interstellar tray will be performed. The total duration of the ISPE will be three years and will differ from the Stardust cometary PE in that data acquisition for the initial characterization stage will be prolonged and will continue simultaneously and parallel with data publications and release of the first samples for further investigation.

Westphal, A. J.↗

The 100th Anniversary of the Fall of Nakhla: The Subdivision of BM1913,25

This year marks the 100th anniversary of the fall of Nakhla, a cumulate clinopyroxenite of martian origin that fell near Alexandria, Egypt in 1911. Multiple fragments of the meteorite were seen to fall over an area of 4.5 km in diameter. Approximately 40 stones were recovered with a combined weight of about 10 kg. Most of the larger specimens found their way to museums and meteorite collections in Cairo, Paris, Berlin, and the Smithsonian, to name a few. In 1998, the British Museum sent a 641g (BM1913,25), fully fusion crusted stone of Nakhla to the Johnson Space Center (JSC) for processing in the Antarctic Meteorite Lab in order to allocate samples to the scientific community. The stone was split in half in a dry nitrogen glove box. One half of the stone was sent back to the museum and the other half (346g) was used for sample allocations. From 1998-2001, 37 scientists requested 65 separate samples of Nakhla, including 2 thin sections This set of allocations was especially important in that all of the sample splits are from the same piece of Nakhla and it had a known history since it was acquired by the museum in 1913. With the multiple fragments of Nakhla, it is not known from what pieces the main bulk of research has been done, what variation may exist between all the pieces and to what contaminants the fragments may have been exposed, (i.e. water, solvents or cutting fluids, etc.). All of the allocations prepared at JSC were processed in a nitrogen cabinet using only stainless steel, aluminum, and Teflon tools and containers to reduce the chance of introducing any new contaminants. The focused effort to subdivide and distribute samples of Nakhla to the meteorite community resulted in enhanced under-standing of Nakhla and nakhlites in general: organic geochemistry, weathering, sulfur isotopes, radiometric age, and magmatic history. There are 13 Nakhlites that have been recovered to date: Nakhla, Layfayette, Governador Valdares, three from NW Africa, three from Yamato and four from Miller Range regions in Antarctica. The Yamato Nakhlites are paired as are the Miller Range samples.

McBridge, Kathleen M.↗

A comparison of methods for representing sparsely sampled random quantities.

This report discusses the treatment of uncertainties stemming from relatively few samples of random quantities. The importance of this topic extends beyond experimental data uncertainty to situations involving uncertainty in model calibration, validation, and prediction. With very sparse data samples it is not practical to have a goal of accurately estimating the underlying probability density function (PDF). Rather, a pragmatic goal is that the uncertainty representation should be conservative so as to bound a specified percentile range of the actual PDF, say the range between 0.025 and .975 percentiles, with reasonable reliability. A second, opposing objective is that the representation not be overly conservative; that it minimally over-estimate the desired percentile range of the actual PDF. The presence of the two opposing objectives makes the sparse-data uncertainty representation problem interesting and difficult. In this report, five uncertainty representation techniques are characterized for their performance on twenty-one test problems (over thousands of trials for each problem) according to these two opposing objectives and other performance measures. Two of the methods, statistical Tolerance Intervals and a kernel density approach specifically developed for handling sparse data, exhibit significantly better overall performance than the others.

Romero, Vicente Jose↗

Atom chip microscopy: A novel probe for strongly correlated materials

Improved measurements of strongly correlated systems will enable the predicative design of the next generation of supermaterials. In this program, we are harnessing recent advances in the quantum manipulation of ultracold atomic gases to expand our ability to probe these technologically important materials in heretofore unexplored regions of temperature, resolution, and sensitivity parameter space. We are working to demonstrate the use of atom chips to enable single-shot, large area detection of magnetic flux at the 10 -7 flux quantum (Φ 0 ) level and below. By harnessing the extreme sensitivity of atomic clocks and Bose-Einstein condensates (BECs) to external perturbations, the cryogenic atom chip technology developed here will provide a magnetic flux detection capability that surpasses other techniques---such as scanning SQUIDs---by a factor of 10 1 --10 3 . We are testing the utility of this technique by using rubidium BECs to image the magnetic fields emanating from charge transport and magnetic domain percolation in strongly correlated materials as they undergo temperature-tuned metal--to--insulator phase transitions. Cryogenic atom chip microscopy introduces three very important features to the toolbox of high-resolution, strongly correlated material microscopy: simultaneous detection of magnetic and electric fields (down to the sub-single electron charge level); no invasive large magnetic fields or gradients; simultaneous micro- and macroscopic spatial resolution; freedom from 1/f flicker noise at low frequencies; and, perhaps most importantly, the complete decoupling of probe and sample temperatures. The first of these features will play an important role in studying the interplay between magnetic and electric domain structure. The last two are crucial for low frequency magnetic noise detection in, e.g., the cuprate pseudogap region and for precision measurements of transport in the high temperature, technologically relevant regime inaccessible to other techniques based on superconducting scanning probes. In periods 1--3 of this grant, which we now close at the University of Illinois at Urbana-Champaign and restart at Stanford University where our new lab is being built, we have demonstrated the ability to rapidly create Rb BECs and trap them within microns of a surface in a cryostat. Period 4 of this grant, to be performed at Stanford, will demonstrate the feasibility of using atom chips with a BEC to image transport features on a cryogenically cooled surface. Successful demonstration, in future funding cycles, will lead directly to the use of system for studies of transport in exotic and technologically relevant materials such as cuprate superconductors and topological insulators.

74 ATOMIC AND MOLECULAR PHYSICS↗

ChIPPS: Charged Information-storage Polymer Preparation System

Technological advances are required to support principal science objectives of missions to the solar system’s icy worlds to seek biosignatures of past/extant life. Sensitivity and reliability are key concerns due to small sample sizes (µL – mL) and the extraordinary import of the results. The preparation and processing of small samples can constrain limits of detection (LoDs); therefore, the Charged Information-storage Polymer Preparation System (ChIPPS) project is advancing the technologies of autonomous sample preparation and processing to add a new class of reliably detectable biosignatures: charged polymers and particles, which can be the information storage-and-transmission means for life. Specifically, we are developing an integrated microfluidic sample-processing unit to prepare icy-world samples to support complementary solid-state nanopore-based analyses: 1) charged-polymer analysis, to characterize variations in polymer chain size, shape, and charge vs. position along the chain; 2) polymer and nanoparticle sizing-and-counting, to characterize the relative abundance of polymer chains, as well as small (virus-sized) particles, by their dimensions and charge. Although no such autonomous system presently exists, such measurements can reveal the nature and abundance of charged polymers that could be used by biological systems to store and transfer information—as DNA and RNA are used terrestrially—without limitation to terrestrial nucleic acids, given that life elsewhere may utilize different information store-and-transfer moieties. Key system components include (a) a lysis unit for mechanical sample disruption; b) an ion-exchange column for charged macromolecule/nanoparticle purification; c) dialyzer to remove excess salt; d) concentrator to enhance signal; e) supporting pumps, valves, bubble traps, connectors, filters, etc.; f) interface to nanopore detection instruments.

Space Biology↗

Measurement of Black Carbon and Particle Number Emission Factors from Individual Heavy-Duty Trucks

Emission factors for black carbon (BC) and particle number (PN) were measured from 226 individual heavy-duty (HD) diesel-fueled trucks driving through a 1 km-long California highway tunnel in August 2006. Emission factors were based on concurrent increases in BC, PN, and CO{sub 2}B concentrations (measured at 1 Hz) that corresponded to the passage of individual HD trucks. The distributions of BC and PN emission factors from individual HD trucks are skewed, meaning that a large fraction of pollution comes from a small fraction of the in-use vehicle fleet. The highest-emitting 10% of trucks were responsible for {approx} 40% of total BC and PN emissions from all HD trucks. BC emissions were log-normally distributed with a mean emission factor of 1.7 g kg {sup -1} and maximum values of {approx} 10 g kg{sup -1}. Corresponding values for PN emission factors were 4.7 x 10{sup 15} and 4 x 10{sup 16} kg{sup -1}. There was minimal overlap among high-emitters of these two pollutants: only 1 of the 226 HD trucks measured was found to be among the highest 10% for both BC and PN. Monte Carlo resampling of the distribution of BC emission factors observed in this study revealed that uncertainties (1{sigma}) in extrapolating from a random sample of n HD trucks to a population mean emission factor ranged from {+-} 43% for n = 10 to {+-} 8% for n = 300, illustrating the importance of sufficiently large vehicle sample sizes in emissions studies. Studies with low sample sizes are also more easily biased due to misrepresentation of high-emitters. As vehicles become cleaner on average in future years, skewness of the emissions distributions will increase, and thus sample sizes needed to extrapolate reliably from a subset of vehicles to the entire in-use vehicle fleet are expected to become more of a challenge.

54 ENVIRONMENTAL SCIENCES↗

Comparisons of classical and Wigner sampling of transition state energy levels for quasiclassical trajectory chemical dynamics simulations

Quasiclassical trajectory calculations are compared, with classical and Wigner sampling of transition state (TS) energy levels, for C{sub 2}H{sub 5}F{sup {ne}{yields}H}F+C{sub 2}H{sub 4} product energy partitioning and [Cl{center_dot}{center_dot}{center_dot}CH{sub 3}{center_dot}{center_dot}{center_dot}Cl]{sup -} central barrier dynamics. The calculations with Wigner sampling are reported here for comparison with the previously reported calculations with classical sampling [Y. J. Cho et al., J. Chem. Phys. 96, 8275 (1992); L. Sun and W. L. Hase, J. Chem. Phys. 121, 8831 (2004)]. The C{sub 2}H{sub 5}F{sup {ne}} calculations were performed with direct dynamics at the MP2/6-31G* level of theory. Classical and Wigner sampling give post-transition state dynamics, for these two chemical systems, which are the same within statistical uncertainties. This is a result of important equivalences in these two sampling methods for selecting initial conditions at a TS. In contrast, classical and Wigner sampling often give different photodissociation dynamics [R. Schinke, J. Phys. Chem. 92, 3195 (1988)]. Here the sampling is performed for a vibrational state of the ground electronic state potential energy surface (PES), which is then projected onto the excited electronic state's PES. Differences between the ground and the excited PESs may give rise to substantially different excitations of the vibrational and dissociative coordinates on the excited state PES by classical and Wigner sampling, resulting in different photodissociation dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three Isotopes of Oxygen in Lunar Samples - The Same as Earth or Different?

One of the most important measurements that can be made for any extraterrestrial sample is determination of the relative abundance of O-16, O-17 and O-18. To make the comparison, investigators report their results as delta (δ) values compared to terrestrial delta O-17 vs delta O-18 for a suite of specimens because for any given reservoir, i.e. a planetary parent body such as the Earth or Mars, the numbers should define a line of gradient approximately one half. Different bodies should be identified from their delta O-17 which has traditionally been defined by the equation delta O-17 = delta O-17 - (a constant, ca. 0.52) × delta O-18.

Pillinger, C. T.↗

Sampling Density in Regional Exploration and Environmental Geochemical Studies: A Review

A variety of factors contribute to the proper and efficient evaluation of geochemical programs including sampling medium, sample size and sample fraction, sampling density, digestion procedure, and analytical techniques. Among the aforementioned factors, sampling density is of great importance, affecting project ability to detect anomalous sites, which are either economically viable or environmentally hazardous. It is quite critical to have a sufficient number of samples to delineate geochemical anomalies or baselines and to reveal the relative variations in elemental concentrations in a study area. The resolution of the subsequent maps obtained by sampling greatly depends on sampling density. While a large number of samples may generate redundant data, a small number of samples smooth out the patterns and may completely miss anomalies. This review provides a platform for applied geochemists who desire to design a sampling scheme for a regional geochemical program and do not have the financial resources to perform an orientation survey, which will give them the necessary information for designing, according to project objectives, a cost-effective regional geochemical survey for their study area. It is advisable to integrate during the desktop study all available information, such as geological, structural, geophysical, remote sensing data and topographical data by using different data fusion algorithms to arrive at a sampling density fit-for-purpose of the target area. This in turn facilitates an effective spatial positioning of sample locations. Quantitative analyses of the efficiency of different sampling densities for delineating geochemical patterns have not been well documented, warranting more attention and research.

58 GEOSCIENCES↗

Growth phase estimation for abundant bacterial populations sampled longitudinally from human stool metagenomes

Longitudinal sampling of the stool has yielded important insights into the ecological dynamics of the human gut microbiome. However, human stool samples are available approximately once per day, while commensal population doubling times are likely on the order of minutes-to-hours. Despite this mismatch in timescales, much of the prior work on human gut microbiome time series modeling has assumed that day-to-day fluctuations in taxon abundances are related to population growth or death rates, which is likely not the case. Here, we propose an alternative model of the human gut as a stationary system, where population dynamics occur internally and the bacterial population sizes measured in a bolus of stool represent a steady-state endpoint of these dynamics. We formalize this idea as stochastic logistic growth. We show how this model provides a path toward estimating the growth phases of gut bacterial populations in situ. We validate our model predictions using an in vitro Escherichia coli growth experiment. Finally, we show how this method can be applied to densely-sampled human stool metagenomic time series data. We discuss how these growth phase estimates may be used to better inform metabolic modeling in flow-through ecosystems, like animal guts or industrial bioreactors.

59 BASIC BIOLOGICAL SCIENCES↗

Suggestions on the Vapor Pressure Determination of Molten Salts

The knowledge of the thermophysical properties of coolant and fuel in molten salts nuclear reactors (MSRs), such as thermal stability and vapor pressure, are of remarkable interest, particularly for simulating safe reactor operations. Molten salt reactorsMSRs use molten salt mixtures as the primary coolant and/or fuel and are expected to operate up to 800 °C. With the revival of interest in deploying MSRs, complete thermophysical and thermochemical characterization of these materials is of interest to industry, regulators, and researchers. Vapor pressure data for molten salts are scarce in the literature, both for pure salts but especially for eutectic mixtures. This report describes the effusion method, which consist of measuring the rate of escape of vapor molecules through a small orifice for the determination of the vapor pressure of compounds and may be useful on compounds such as molten salts. Thermogravimetric analysis records the mass loss as a function of time and temperature. There are two equations that can be used to relate the mass loss rate with the vapor pressure: (1) the Knudsen equation and (2) the Langmuir equation. To apply these equations, the system needs to reach a pseudo (or near) equilibrium condition. Therefore, the experimental conditions must be such that allow the condensed and the vapor/gas phases to be in equilibrium. In order to accomplish equilibrium like conditions, the sample must be in an almost-sealed cell except for a small orifice, from where the vapor escapes. In the Knudsen method vacuum is applied to eliminate the effect that the presence of other gas molecules could have on the evaporation rate of the sample. However, Langmuir alleged that in certain conditions, such as at low temperatures and/or when the vapor pressure is low, the rate of evaporation of a substance is independent of the presence of vapor around it. For that reason, some researchers, when measuring the mass loss of a substance with a predictable low vapor pressure, do not apply vacuum when using the Langmuir equation. However, they use a standard substance to parameterize the experimental setup. The use of one equation or the other will depend on the characteristics of the sample and the availability of an appropriate standard. Some important aspects related to the nature of the samples and vapor pressure measurements are described for future consideration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Noncollinear ferromagnetic easy axes in Py/Ru/FeCo/IrMn spin valves induced by oblique deposition

We present an investigation on the magnetic properties of Py/Ru/FeCo/IrMn spin valves grown by dc magnetron sputtering. The sample fabrication setup has two important features, (i) the five magnetron sputtering sources are placed in a cluster flange 72° from each other, and (ii) each source is tilted with respect to the sample normal. In-plane angular dependence of the ferromagnetic resonance (FMR) was used to obtain the relevant magnetic anisotropies, such as uniaxial and exchange bias fields. The oblique deposition geometry employed has induced non-collinear easy axes of the two ferromagnetic (FM) layers, with high uniaxial field strengths. The symmetry shift of the angular dependence of the FMR resonances of the two FM layers gives us directly the angle between the easy axes of FM{sub 1} (Py) and FM{sub 2} (FeCo), which turned out to be the angle between two adjacent sputtering sources. The observations of the present study suggest that, by combining oblique deposition and appropriate angles of incidence of the deposition flux, the uniaxial (and unidirectional) axes of individual FM layers can be precisely engineered in spin valve fabrication.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bayesian Inference in Probabilistic Risk Assessment -- The Current State of the Art

Markov chain Monte Carlo approaches to sampling directly from the joint posterior distribution of aleatory model parameters have led to tremendous advances in Bayesian inference capability in a wide variety of fields, including probabilistic risk analysis. The advent of freely available software coupled with inexpensive computing power has catalyzed this advance. This paper examines where the risk assessment community is with respect to implementing modern computational-based Bayesian approaches to inference. Through a series of examples in different topical areas, it introduces salient concepts and illustrates the practical application of Bayesian inference via Markov chain Monte Carlo sampling to a variety of important problems.

99 GENERAL AND MISCELLANEOUS↗

Small-Chamber Measurements of Chemical-Specific Emission Factors for Drywall

Imported drywall installed in U.S. homes is suspected of being a source of odorous and potentially corrosive indoor pollutants. To support an investigation of those building materials by the Consumer Products Safety Commission (CPSC), Lawrence Berkeley National Laboratory (LBNL) measured chemical-specific emission factors for 30 samples of drywall materials. Emission factors are reported for 75 chemicals and 30 different drywall samples encompassing both domestic and imported stock and incorporating natural, synthetic, or mixed gypsum core material. CPSC supplied all drywall materials. First the drywall samples were isolated and conditioned in dedicated chambers, then they were transferred to small chambers where emission testing was performed. Four sampling and analysis methods were utilized to assess (1) volatile organic compounds, (2) low molecular weight carbonyls, (3) volatile sulfur compounds, and (4) reactive sulfur gases. LBNL developed a new method that combines the use of solid phase microextraction (SPME) with small emission chambers to measure the reactive sulfur gases, then extended that technique to measure the full suite of volatile sulfur compounds. The testing procedure and analysis methods are described in detail herein. Emission factors were measured under a single set of controlled environmental conditions. The results are compared graphically for each method and in detailed tables for use in estimating indoor exposure concentrations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗