Search NASA⌕ Search

SEARCH · Search NASA

Results for “Insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

High-Speed Ionic Synaptic Memory Based on 2D Titanium Carbide MXene

Synaptic devices with linear high-speed switching can accelerate learning in artificial neural networks (ANNs) embodied in hardware. Conventional resistive memories however suffer from high write noise and asymmetric conductance tuning, preventing parallel programming of ANN arrays. Electrochemical random-access memories (ECRAMs), where resistive switching occurs by ion insertion into a redox-active channel, aim to address these challenges due to their linear switching and low noise. ECRAMs using 2D materials and metal oxides however suffer from slow ion kinetics, whereas organic ECRAMs enable high-speed operation but face challenges toward on-chip integration due to poor temperature stability of polymers. Here, ECRAMs using 2D titanium carbide (Ti 3 C 2 T x ) MXene that combine the high speed of organics and the integration compatibility of inorganic materials in a single high-performance device are demonstrated. These ECRAMs combine the speed, linearity, write noise, switching energy, and endurance metrics essential for parallel acceleration of ANNs, and importantly, they are stable after heat treatment needed for back-end-of-line integration with Si electronics. The high speed and performance of these ECRAMs introduces MXenes, a large family of 2D carbides and nitrides with more than 30 stoichiometric compositions synthesized to date, as promising candidates for devices operating at the nexus of electrochemistry and electronics.

2D materials↗

Gain analysis of higher-order-mode amplification in a dielectric-implanted multi-beam traveling wave structure

A multi-beam traveling wave amplifier designed with an overmoded staggered double grating array was examined by small signal analysis combined with simulation. Eigenmode and S-parameter analyses show that the 2 cm long slow wave structure (SWS) has 1–5 dB insertion loss over the passband (TM{sub 31} mode) with ∼28% cold bandwidth. Analytic gain calculation indicates that in the SWS, TM{sub 31}-mode is amplified with 15–20 dB/beam at 64–84 GHz with three elliptical beams of 10 kV and 150 mA/beam, which was compared with particle-in-cell (PIC) simulations. PIC analysis on the analysis of instability with zero-input driving excitations demonstrated that background noises and non-operating lower order modes are noticeably suppressed by implanting equidistant dielectric absorbers; the overmoded structure only allowed the desired 3rd order mode to propagate in the structure. The designed circuit structure can be widely applied to multi-beam devices for high power RF generation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin–orbit torques in structures with asymmetric dusting layers

Current-induced spin–orbit torques (SOTs) in heavy metal/ferromagnet heterostructures have emerged as an efficient method for magnetization switching with applications in nonvolatile magnetic memory and logic devices. However, experimental realization of SOT switching of perpendicular magnetization requires an additional inversion symmetry breaking, calling for modifications of the conventional SOT heterostructures. In this work, we study SOTs and deterministic switching of perpendicular magnetization by inserting different asymmetric dusting layers at the heavy metal/ferromagnet interface. Similar to the previous works with lateral structural asymmetry, we study the emergence of current-induced perpendicular effective magnetic fields (H z eff ). By examining three different material combinations of heavy metal/dusting layers (W/IrMn, Pt/IrMn, and W/Ta), we shed light on the origins of H z eff ; we show that H z eff is generically created in all the studied asymmetric structures, has a close correlation with the interfacial magnetic anisotropy, and is independent of the signs of spin Hall angles of the materials. Furthermore, we show that the induction of H z eff enables field-free deterministic SOT switching of perpendicular magnetization. Our results can be used in designing SOT heterostructures for practical applications in nonvolatile technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Airborne particle monitoring by electrostatic precipitation

For qualitative analysis of atmospheric particulates by microscopy, the sampling device should preserve the particles in the state existing at the moment of capture. A collector is described that uses electrostatic precipitation to capture and disperse specimens on various substrates for direct insertion into microscopes. Sampling runs in various atmospheres are described. Micrographs are presented to show particle morphology and distribution on the substrates. Chemical identification by X-ray energy probe and electron diffraction is illustrated.

Robinson, J. C.↗

Testing Fixture For Microwave Integrated Circuits

Testing fixture facilitates radio-frequency characterization of microwave and millimeter-wave integrated circuits. Includes base onto which two cosine-tapered ridge waveguide-to-microstrip transitions fastened. Length and profile of taper determined analytically to provide maximum bandwidth and minimum insertion loss. Each cosine taper provides transformation from high impedance of waveguide to characteristic impedance of microstrip. Used in conjunction with automatic network analyzer to provide user with deembedded scattering parameters of device under test. Operates from 26.5 to 40.0 GHz, but operation extends to much higher frequencies.

Romanofsky, Robert↗

Enhancement of Mixing and Heat Transfer by Corrugated Permeable Walls

A re-circulation method that is based on the static pressure recovery in the divergent part of a converging-diverging flow channel is discussed. This method can be used to design a static device that can be used to increase the residence time of the fluid and the mixing in the transverse and/or flow directions in compressible and incompressible fluids flowing at subsonic velocities. The device with external reverse flow channels will produce mixing in both transverse and flow directions. If mixing in the flow direction is not desired, the concept can be used to design an insert to provide only transverse mixing. Theoretical relationships for a re-circulating one-dimensional incompressible flow around a converging-diverging channel were obtained. Attempts at numerical simulation of re-circulation in compressible fluids were not successful. Qualitative experimental verification of re-circulating flows for incompressible and compressible fluids were obtained.

Gilinsky, M.↗

Piezoelectric-triboelectric heel charger to generate electricity from locomotion using level mechanism and mechanical SSHI boosting circuit

The disclosure provides an electricity generating insert for a piece of footwear, the insert can be removably placed in the heel portion, e.g. under the insole. The insert comprises a multilayer piezoelectric stack that alternatively flexes under the compression-decompression that occurs during locomotion, which flexing causes friction in the stack to generate electricity capable of charging electronic devices and the like, e.g. via a port on the footwear.

Wang, Ya↗

A new cubic phantom for PET/CT dosimetry: Experimental and Monte Carlo characterization

In recent years, positron emission tomography (PET) associated with multidetector computed tomography (MDCT) has become a diagnostic technique widely disseminated to evaluate various malignant tumors and other diseases. However, during PET/CT examinations, the doses of ionizing radiation experienced by the internal organs of patients may be substantial. To study the doses involved in PET/CT procedures, a new cubic phantom of overlapping acrylic plates was developed and characterized. This phantom has a deposit for the placement of the fluorine-18 fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) solution. There are also small holes near the faces for the insertion of optically stimulated luminescence dosimeters (OSLD). The holes for OSLD are positioned at different distances from the {sup 18}F-FDG deposit. The experimental results were obtained in two PET/CT devices operating with different parameters. Differences in the absorbed doses were observed in OSLD measurements due to the non-orthogonal positioning of the detectors inside the phantom. This phantom was also evaluated using Monte Carlo simulations, with the MCNPX code. The phantom and the geometrical characteristics of the equipment were carefully modeled in the MCNPX code, in order to develop a new methodology form comparison of experimental and simulated results, as well as to allow the characterization of PET/CT equipments in Monte Carlo simulations. All results showed good agreement, proving that this new phantom may be applied for these experiments. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination of absorbed dose in water at the reference point D(r{sub 0},{theta}{sub 0}) for an {sup 192}Ir HDR brachytherapy source using a Fricke system

A ring-shaped Fricke device was developed to measure the absolute dose on the transverse bisector of a {sup 192}Ir high dose rate (HDR) source at 1 cm from its center in water, D(r{sub 0},{theta}{sub 0}). It consists of a polymethylmethacrylate (PMMA) rod (axial axis) with a cylindrical cavity at its center to insert the {sup 192}Ir radioactive source. A ring cavity around the source with 1.5 mm thickness and 5 mm height is centered at 1 cm from the central axis of the source. This ring cavity is etched in a disk shaped base with 2.65 cm diameter and 0.90 cm thickness. The cavity has a wall around it 0.25 cm thick. This ring is filled with Fricke solution, sealed, and the whole assembly is immersed in water during irradiations. The device takes advantage of the cylindrical geometry to measure D(r{sub 0},{theta}{sub 0}). Irradiations were performed with a Nucletron microselectron HDR unit loaded with an {sup 192}Ir Alpha Omega radioactive source. A Spectronic 1001 spectrophotometer was used to measure the optical absorbance using a 1 mL quartz cuvette with 1.00 cm light pathlength. The PENELOPE Monte Carlo code (MC) was utilized to simulate the Fricke device and the {sup 192}Ir Alpha Omega source in detail to calculate the perturbation introduced by the PMMA material. A NIST traceable calibrated well type ionization chamber was used to determine the air-kerma strength, and a published dose-rate constant was used to determine the dose rate at the reference point. The time to deliver 30.00 Gy to the reference point was calculated. This absorbed dose was then compared to the absorbed dose measured by the Fricke solution. Based on MC simulation, the PMMA of the Fricke device increases the D(r{sub 0},{theta}{sub 0}) by 2.0%. Applying the corresponding correction factor, the D(r{sub 0},{theta}{sub 0}) value assessed with the Fricke device agrees within 2.0% with the expected value with a total combined uncertainty of 3.43%(k=1). The Fricke device provides a promising method towards calibration of brachytherapy radiation sources in terms of D(r{sub 0},{theta}{sub 0}) and audit HDR source calibrations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neuromorphic Photonics Based on Phase Change Materials

Neuromorphic photonics devices based on phase change materials (PCMs) and silicon photonics technology have emerged as promising solutions for addressing the limitations of traditional spiking neural networks in terms of scalability, response delay, and energy consumption. In this review, we provide a comprehensive analysis of various PCMs used in neuromorphic devices, comparing their optical properties and discussing their applications. We explore materials such as GST (Ge 2 Sb 2 Te 5 ), GeTe-Sb 2 Te 3 , GSST (Ge 2 Sb 2 Se 4 Te 1 ), Sb 2 S 3 /Sb 2 Se 3 , Sc 0.2 Sb 2 Te 3 (SST), and In 2 Se 3 , highlighting their advantages and challenges in terms of erasure power consumption, response rate, material lifetime, and on-chip insertion loss. By investigating the integration of different PCMs with silicon-based optoelectronics, this review aims to identify potential breakthroughs in computational performance and scalability of photonic spiking neural networks. Further research and development are essential to optimize these materials and overcome their limitations, paving the way for more efficient and high-performance photonic neuromorphic devices in artificial intelligence and high-performance computing applications.

36 MATERIALS SCIENCE↗

SU-D-BRF-05: A Novel System to Provide Real-Time Image-Guidance for Intrauterine Tandem Insertion and Placement

Purpose: To develop a system that provides real-time image-guidance for intrauterine tandem insertion and placement for brachytherapy. Methods: The conceptualized system consists of an intrauterine tandem with a transparent, lensed tip, a flexible miniature fiber optic scope, light source and interface for CCD coupling. The tandem tip was designed to act as a lens providing a wide field-of-view (FOV) with minimal image distortion and focus length appropriate for the application. The system is designed so that once inserted, the image-guidance component of the system can be removed and brachytherapy can be administered without interfering with source transport or disturbing tandem placement. Proof-of-principle studies were conducted to assess the conceptualized system's (1) lens functionality (clarity, focus and FOV) (2) and ability to visualize the cervical os of a female placed in the lithotomy position. Results: A prototype of this device was constructed using a commercial tandem modified to incorporate a transparent tip that internally coupled with a 1.9mm diameter fiber optic cable. The 900mm-long cable terminated at an interface that provided illumination as well as facilitated visualization of patient anatomy on a computer. The system provided a 23mm FOV with a focal length of 1cm and provided clear visualization of the cervix, cervical fornix and cervical os. The optical components of the system are easily removed without perturbing the position of a tandem placed in a common fixation clamp. Conclusion: Clinicians frequently encounter difficulty inserting an intrauterine tandem through the cervical os, circumventing fibrotic tissue or masses within the uterus, and positioning the tandem without perforating the uterus. To mitigate these challenges, we have designed and conducted proof-of- principle studies to discern the utility of a prototype device that provides real-time image-guidance for intrauterine tandem placement using fiber optic components.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

QuantumNAT: quantum noise-aware training with noise injection, quantization and normalization

Parameterized Quantum Circuits (PQC) are promising towards quantum advantage on near-term quantum hardware. However, due to the large quantum noises (errors), the performance of PQC models has a severe degradation on real quantum devices. Take Quantum Neural Network (QNN) as an example, the accuracy gap between noise-free simulation and noisy results on IBMQ-Yorktown for MNIST-4 classification is over 60%. Existing noise mitigation methods are general ones without leveraging unique characteristics of PQC; on the other hand, existing PQC work does not consider noise effect. To this end, we present QuantumNAT, a PQC-specific framework to perform noise-aware optimizations in both training and inference stages to improve robustness. We experimentally observe that the effect of quantum noise to PQC measurement outcome is a linear map from noise-free outcome with a scaling and a shift factor. Motivated by that, we propose post-measurement normalization to mitigate the feature distribution differences between noise-free and noisy scenarios. Furthermore, to improve the robustness against noise, we propose noise injection to the training process by inserting quantum error gates to PQC according to realistic noise models of quantum hardware. Lastly, post-measurement quantization is introduced to quantize the measurement outcomes to discrete values, achieving the denoising effect. Extensive experiments on 8 classification tasks using 6 quantum devices demonstrate that QuantumNAT improves accuracy by up to 43%, and achieves over 94% 2-class, 80% 4-class, and 34% 10-class classification accuracy measured on real quantum computers. The code for construction and noise-aware training of PQC is available in the TorchQuantum library.

Wang, Hanrui↗

The Dynamometer Hub for the Testing Propellers and Engines During Flight

The need for a device to measure flight resistance, engine and propeller power, and efficiency during flight grew in proportion to the demand for increased flying capacity in military types of aircraft. Here, a dynamometer hub was inserted between the engine and the propeller. Taken as a whole, the tests that were conducted show that though the dynamometer is a sensitive instrument liable to numerous derangements, it is undeniably useful even in its present form, when handled with care and skill. Facilitating, as it does, the possibility of maintaining the fixed position of the engine, the blocking out of the weight effect when the plane is in the sloping position, and the possibility of taking direct measurements of force at the point of transmission, the dynamometer appears to be by far the best solution of the problem of a flying test bench, utilized as a hydraulic balance with the smallest possible measuring stroke and the least tendency to oscillation.

Enoch, O↗

Containment seal

A containment seal seals a cable or tube to an opening accessing a containment vessel. The containment seal includes a lower body that attaches over the opening into the containment vessel. The cable or tube is inserted through a hole that extends axially through an upper body of the containment seal. Compression fittings are attached to the top and bottom ends of the upper body sealing the cable inside of the upper body. The cable sealed inside of the upper body in inserted through the lower body and into the opening accessing the containment vessel and a lower portion of the upper body is seated into the opening formed in the lower body. A retaining device compresses the upper body down against the lower body forming a seal between the upper body and lower body.

42 ENGINEERING↗

Inserting a Low-Refractive-Index Dielectric Rear Reflector into PERC Cells: Challenges and Opportunities

One of the simplest and most effective ways to reduce the operating temperature of photovoltaic systems in the field is to reflect unusable, 'sub-bandgap' light with energies below the cell absorber's bandgap energy. In this work, low-refractive index SiO2 nanoparticle films inserted between c-Si wafers and metal electrodes significantly increase the reflectance of sub-bandgap light in fabricated test structures. These films are then integrated into the standard PERC fabrication sequence, revealing that the reflection benefits remains after some processing steps but are lost in certain conditions. The SiO2 nanoparticle films are easily ablated during laser contact opening, but are undesirably etched during post-laser cleaning. After Al metallization, the fully fabricated devices show enhanced sub-bandgap reflection when annealed at moderate temperatures, but energy-dispersive X-ray spectroscopy shows that high-temperature firing causes unwanted Al penetration into the SiO2 nanoparticle film, compromising reflection.

14 SOLAR ENERGY↗

Nanoscale Protection Layers To Mitigate Degradation in High-Energy Electrochemical Energy Storage Systems

In the pursuit of energy storage devices with higher energy and power, new ion storage materials and high-voltage battery chemistries are of paramount importance. Yet, they invite—and often enhance—degradation mechanisms, which are reflected in capacity loss with charge/discharge cycling and sometimes in safety problems. Degradation mechanisms are often driven by fundamentals such as chemical and electrochemical reactions at electrode–electrolyte interfaces, volume expansion and stress associated with ion insertion and extraction, and profound inhomogeneity of electrochemical behavior. Although it is important to identify and understand these mechanisms at some reasonable level, it is even more critical to design strategies to mitigate these degradation pathways and to develop means to implement and validate the strategies. A growing set of research highlights the mitigation benefits achievable by forming thin protection layers (PLs) intentionally created as artificial interphase regions at the electrode–electrolyte interface. These advances highlight a promising—perhaps even generic—pathway for enabling higher-energy and higher-voltage battery configurations. In this Account, we summarize examples of such PLs that serve as mitigation strategies to avoid degradation in lithium metal anodes, conversion-type electrode materials, and alloy-type electrodes. Examples are chosen from a larger body of electrochemical degradation research carried out in Nanostructures for Electrical Energy Storage (NEES), our DOE Energy Frontier Research Center. Overall, we argue on the basis of experimental and theoretical evidence that PLs effectively stabilize the electrochemical interfaces to prevent parasitic chemical and electrochemical reactions and mitigate the structural, mechanical, and compositional degradation of the electrode materials at the electrode–electrolyte interfaces. The evidenced improvement in performance metrics is accomplished by (1) establishing a homogeneous interface for ion insertion and extraction, (2) providing mechanical constraints to maintain structural integrity and robust electronic and ionic conduction pathways, and (3) introducing spatial confinements on the electrode material matrix to alter the phase transformation (delaying the occurrence of the conversion reaction) upon Li insertion, which results in superior electrode performance, excellent capacity retention, and improved reversibility. Taken together, these examples portray a valuable role for thin protection layers synthesized over electrode surfaces, both for their benefit to cycle stability and for revealing insights into degradation and mitigation mechanisms. Furthermore, they underscore the impact of complex electrochemical behavior at nanoscale materials and nanostructure interfaces in modulating the behavior of energy storage devices at the mesoscale and macroscale.

25 ENERGY STORAGE↗

Electroactive ZnO: Mechanisms, Conductivity, and Advances in Zn Alkaline Battery Cycling

Zinc oxide is of great interest for advanced energy devices because of its low cost, wide direct bandgap, non-toxicity, and facile electrochemistry. In zinc alkaline batteries, ZnO plays a critical role in electrode passivation, a process that hinders commercialization and remains poorly understood. Here, novel observations of an electroactive type of ZnO formed in Zn-metal alkaline electrodes are disclosed. The electrical conductivity of battery-formed ZnO is measured and found to vary by factors of up to 104, which provides a first-principles-based understanding of Zn passivation in industrial alkaline batteries. Simultaneous with this conductivity change, protons are inserted into the crystal structure and electrons are inserted into the conduction band in quantities up to ≈1020 cm−3 and ≈1 mAh gZnO−1. Electron insertion causes blue electrochromic coloration with efficiencies and rates competitive with leading electrochromic materials. The electroactivity of ZnO is evidently enabled by rapid crystal growth, which forms defects that complex with inserted cations, charge-balanced by the increase of conduction band electrons. This property distinguishes electroactive ZnO from inactive classical ZnO. Knowledge of this phenomenon is applied to improve cycling performance of industrial-design electrodes at 50% zinc utilization and the authors propose other uses for ZnO such as electrochromic devices.

Brendan E. Hawkins↗

ECRAM Materials, Devices, Circuits and Architectures: A Perspective

Abstract Non‐von‐Neumann computing using neuromorphic systems based on two‐terminal resistive nonvolatile memory elements has emerged as a promising approach, but its full potential has not been realized due to the lack of materials and devices with the appropriate attributes. Unlike memristors, which require large write currents to drive phase transformations or filament growth, electrochemical random access memory (ECRAM) decouples the “write” and “read” operations using a “gate” electrode to tune the conductance state through charge‐transfer reactions, and every electron transferred through the external circuit in ECRAM corresponds to the migration of ≈1 ion used to store analogue information. Like static dopants in traditional semiconductors, electrochemically inserted ions modulate the conductivity by locally perturbing a host's electronic structure; however, ECRAM does so in a dynamic and reversible manner. The resulting change in conductance can span orders of magnitude, from gradual increments needed for analog elements, to large, abrupt changes for dynamically reconfigurable adaptive architectures. In this in‐depth perspective, the history of ECRAM, the recent progress in devices spanning organic, inorganic, and 2D materials, circuits, architectures, the rich portfolio of challenging, fundamental questions, and how ECRAM can be harnessed to realize a new paradigm for low‐power neuromorphic computing are discussed.

Talin, A. Alec↗