Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADS - DISKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

ECAR-1943 AGC-1 INDIVIDUAL SPECIMEN FLUENCE, TEMPERATURE, AND LOAD CALCULATION AND TABULATION

This ECAR calculates the fluence and temperature of the AGC-1 specimens as they change elevation through the course of the experiment. The specimen elevation varies as the specimen stack shrinks due to irradiation and load induced creep. The compressed specimen stacks (S-1 thru S-6) have a graphite pushrod that applies a gas cylinder load. The top of the pushrod position is measured and recorded in the NGNP Data Management and Analysis System (NDMAS). The bottom of each of these compressed stacks is supported by the lower specimen holder which also shrinks as a result of irradiation and load. The specimen holder post-irradiation length was recorded during post-irradiation examination (PIE). Assuming the specimen holder shrinkage is linear with respect to the fluence received, the position of the top of the specimen holder can be calculated with respect to reactor integrated power. Assuming that individual specimen shrinkage is proportional to the fluence received, and that the shrinkage behavior is similar in all the specimens, the individual specimen position can be calculated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Effect of Inverter Loading Ratio on Energy Estimate Bias: Preprint

Subhourly effects, particularly variability in solar irradiance, can lead to underestimation of inverter clipping losses and overestimation of energy in hourly photovoltaic system performance models, particularly for systems with high inverter loading ratios. Direct simulation of this error can be complicated by factors such as the representation of spatial and temporal variability in hourly weather data and transient system conditions. In this work we take an alternative approach using real system power measurements to show that energy predictions from typical industry models suffer from a bias that increases with inverter loading ratio. We also show that this loading ratio-dependent bias is strongly correlated with an empirical subhourly inverter clipping bias derived from real power plant data. Finally, we show that this bias is not necessarily specific to any one model or weather dataset by recreating similar biases with alternatives of each.

clipping↗

Electrocatalyst comprising a crumpled transition metal dichalcogenide support loaded with monodispersed metal nanoparticles

An electrocatalyst comprises a crumpled transition metal dichalcogenide support loaded with catalytic metal nanoparticles through spontaneous reduction reactions. The support can be prepared by hydrothermal conversion of 2D nanosheets to 3D hierarchically crumpled sheets. As an example, using crumpled MoS 2 as a support, highly tunable Ru loadings were obtained using the electrostatic interaction between MoS 2 and RuCl 3 in solution. Control over Ru loading was leveraged to produce Ru—MoS 2 electrocatalysts that demonstrate different nitrogen reduction reaction activities, and which show varying resistance to electrochemical sintering and deactivation. Further, these high surface area materials can be utilized for many applications, including electrocatalysts, supercapacitors, and batteries.

Percival, Stephen↗

A Robust Processing Approach for Producing Highly Loaded Dispersion Fuels

A robust fabrication method, resulting in higher yields, to produce highly loaded U3Si2-Al dispersion fuels for converting research reactors from a high enriched to a low enriched uranium fuel needs to be developed. To reliably produce a highly loaded dispersion fuel, process changes need to be implemented where the traditional approach has experienced challenges and poor yields. The present work describes the key changes needed. Parts of the work were done with uranium silicide and parts were completed with a representative silicide surrogate. The major deviations from traditional fabrication methods are associated with a refinement in particle size distribution, method for compacting to achieve complex shapes, and welding of the aluminum picture frame used to encapsulate the fuel compact. Methods for rolling and arc melting are also discussed. By using the methods described within, fabricating a highly loaded dispersion fuel that can meet stringent fuel homogeneity and geometry requirements at higher yields and lower costs may be possible.

U3Si2, HFIR, dispersion fuel, Uranium, Research Re↗

Overview of a Versatile Loading System for Anisotropic Material Property Characterization

Additive manufacturing, cold rolling, and other thermomechanical treatments on metals, especially HCP, can cause texture and oriented grain structures resulting in anisotropic mechanical properties. This can lead to macroscopic response that significantly deviates from isotropic assumptions which motivates studying mechanical properties in multiple directions. In addition, multiaxial loading and complex stress states overlapping the above mentioned material anisotropy can lead to unexpected outcomes. Idaho National Laboratory developed an advanced mechanical testing system to study a range of uniaxial to multiaxial stress states while measuring the anisotropic response bringing insight into the overlap between material properties and stress states. High-temperature capability and stress- or strain-controlled loading is available to enable a variety of experiment types and conditions to measure elastic, plastic, and viscoplastic properties. This poster presents the design and capabilities of this system with preliminary results highlighting the benefits of multiaxial loading and anisotropic analysis in an integrated system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Comparing Interaction Graphs on Cascading Outages under Different Loading Conditions

Interaction graphs on cascading outages of power systems provide valuable insights into how cascading outages evolve and propagate, and which components and links are critical to the propagation of cascading outages, enabling further development of mitigation strategies to support decision-making. However, the sensitivity of the interaction graph’s topology to the system’s loading condition has not been studied sufficiently. This paper compared interaction graphs under various loading conditions on the Northeastern Power Coordinating Council 140-bus system, and discovers the strong relationships between the graph topology, the cascade size distribution, and the load condition. Accordingly, three representative interaction graphs are constructed and illustrated.

Guo, Zhenping↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Power Quality and Load Capacity Evaluations of an Electric Vehicle for Multi-Robot System Applications

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

Electric vehicle↗

Demand response of loads having thermal reserves

Systems and methods are described herein that improve grid performance by smoothing demand using thermal reserves. The smoothed demand can reduce peak loads as well as the ramp rate of demand that will otherwise require the use of inefficient, expensive generation sources. These improvements are tied to the selective switching on or off electrical loads that are coupled to thermal reserves, effectively using the thermal reserves as an energy storage mechanism. Historical data of past usage can be used to create load model and ensure that effects on customer comfort are minimized while still accomplishing the beneficial effects for the overall grid, which enables grid owners to both reduce their operational cost by avoiding expensive generation and improve system reliability by achieving more predictable power demand.

Ren, Wei↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign, an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real-time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB650 CM.

Yoon, S. [Fermilab]↗

Early Research in Load-Following Management for HPC-Nuclear Integration

With the rising demand for high performance computing (HPC) and artificial intelligence (AI) systems, maintaining a stable and efficient power supply is increasingly critical. The HPC team at Idaho National Laboratory is spearheading efforts to seamlessly integrate HPC systems with nuclear reactors. This lightning talk explores one early strategy for managing power fluctuations using software-defined controls. To effectively harness nuclear reactors for power generation, control mechanisms are essential to address the slow load-following capabilities of reactors, which are typically around 5% per minute. While this rate is sufficient for many uses, large HPC systems can experience rapid power consumption changes by tens of megawatts when jobs start or stop running. A reactor could overproduce power and match the peak power rating for the HPC system, however when the system is not running a job or a job unexpectedly stops, the load-following of the system would be affected leading to power being wasted and the likelihood of power transient occurrences increases. Controlling the increase or decrease of power consumption on these systems at the same rate as the load-following of reactors is one piece of the puzzle to properly utilizing nuclear reactors as a power source for HPC systems.

97 - MATHEMATICS AND COMPUTING↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of data-driven models for quantifying load shed by non-residential buildings in the United States

Shifting and shedding power demand in buildings can be cost-effective techniques for grids to function reliably and for end users to earn compensation. Grid operators reimburse customers in proportion to the quantity of load shed. Simple data-driven methods are used to quantify this shed, which is the difference between a measured load during the event and modeled "baseline" that would have occurred in absence of the event. These methods have evolved over the years and in many cases have been integrated with building physics, to make them a hybrid between physics based and empirical models. However, there is no comprehensive analysis that provides guidance to building operators, grid operators and researchers in selecting appropriate models based on their specific needs and available data. Here, this work aims to fill this gap by critically assessing the performance of baseline models put forward from the year 2000 through 2023. The literature reviewed includes reports generated by grid operators, reports from national laboratories and academic journal articles. The work outlines modeling features like the inputs, training period, estimation method, adjustments to fine tune the predictions and metrics to evaluate the performance. A comprehensive list of 50 models has been provided. For each model, the study explores the applicability of the model to weather sensitive buildings, variability in the building profile, timing of the event, and whether the building reduces energy consumption before an event. The work identifies the situations in which a particular model works and draws lessons based on evidence of performance. Finally, recommendations to aid in model selection are given.

97 MATHEMATICS AND COMPUTING↗

Estimating the value of jointly optimized electric power generation and end use: a study of ISO-scale load shaping applied to the residential building stock

A generation-to-load simulation estimated the impact, in terms of production costs and CO2 emissions, attributable to the joint optimization of electric power generation and flexible end uses to support increasing penetrations of renewable energy. Newly conceived, evaluated, and foundational in developing a U.S. National Standard was a transaction-less yet continuous demand response system based on a day-ahead optimum load shape (OLS) designed to encourage Internet-connected devices to autonomously and voluntarily explore options to favour lowest cost generators - without requiring two-way communications, personally identifiable information, or customer opt-in. Boundary conditions used for model calibration included historical weather, residential building stock construction attributes, home appliance and device empirical operating schedules, prototypical power distribution feeder models, thermal generator heat rates, startup and ramping constraints, and fuel costs. Results of an hourly-based annual case study of Texas indicate a 1/3 reduction in production costs and a 1/5 reduction in CO2 emissions are possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A 4 kV/120 A SiC Solid-State DC Circuit Breaker Powered By a Load-Independent IPT System

This article introduces a 4 kV/120 A solid-state dc circuit breaker (DCCB) based on discrete SiC mosfets. The DCCB is designed in a five-layer tower structure. Each layer consists of a circular main conduction branch and an attached gate driver. There are two primary benefits of the proposed DCCB. First, it reduces conduction loss with multiple devices in parallel. Second, it achieves an ultrafast response speed with SiC mosfets. Moreover, the gate drivers of the DCCB are powered by a domino inductive power transfer (IPT) system. It achieves the load-independent constant-voltage output characteristics, which means the outputs are immune to load variations. Additionally, an IPT system prototype is implemented to test the power transfer performance. At 500-kHz frequency, the total output power reaches 15.73 W, which is sufficient to power on five gate drivers, with a peak transfer efficiency of 75.4%. The IPT system is tested to power a 4 kV/120 A DCCB prototype. It validates that the DCCB is effective to turn off 120 A current within 3.5 μs.

42 ENGINEERING↗

Semi-Supervised, Non-Intrusive Disaggregation of Nodal Load Profiles With Significant Behind-the-Meter Solar Generation

It is of imperative interests for regional transmission organizations (RTOs) to effectively extract actual load profiles at transmission nodes with significant behind-the-meter solar generation, which remains a gap in the existing technology paradigm. This paper proposes an explicit yet efficient linear estimator to disaggregate actual load profiles at transmission buses with significant behind-the-meter (BTM) solar generations. The proposed estimator is based on disaggregating (i.e., extracting) at locations close to transmission buses under consideration. Further, to overcome the lack of “ground truth” and validate the performance of the proposed algorithms, we first propose semi-supervised mechanisms with parameter tuning as well as unsupervised clustering and leverage the unique characteristics of zero-crossing points in BTM solar peaking behaviors, which we refer to as “Zone-to-Node (Z2N)” methods. Next, we further propose a bi-level Node-to-Node (N2N) framework that improves the overall disaggregation performances compared to Z2N. Numerical results are presented using real-world data at PJM Interconnection.

14 SOLAR ENERGY↗

Hardware Implementation and Market Impacts of Grid-Supportive Functions in End-Use Loads

Grid-supportive loads (GSLs) are power electronics-based end-use loads that can provide frequency response and other grid services by autonomously adjusting their output power using local grid measurements. This report provides details on GSL hardware design options and their associated costs and benefits for multiple devices, including EV chargers, refrigerators, and heat pumps. We consider mechanisms to incentivize adoption of GSLs at scale and estimate the quantity of frequency response that can be procured with GSLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗