Search NASA⌕ Search

SEARCH · Search NASA

Results for “Life Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Reliability Evaluation of Base-Metal-Electrode Multilayer Ceramic Capacitors for Potential Space Applications

Base-metal-electrode (BME) ceramic capacitors are being investigated for possible use in high-reliability spacelevel applications. This paper focuses on how BME capacitors construction and microstructure affects their lifetime and reliability. Examination of the construction and microstructure of commercial off-the-shelf (COTS) BME capacitors reveals great variance in dielectric layer thickness, even among BME capacitors with the same rated voltage. Compared to PME (precious-metal-electrode) capacitors, BME capacitors exhibit a denser and more uniform microstructure, with an average grain size between 0.3 and 0.5 m, which is much less than that of most PME capacitors. BME capacitors can be fabricated with more internal electrode layers and thinner dielectric layers than PME capacitors because they have a fine-grained microstructure and do not shrink much during ceramic sintering. This makes it possible for BME capacitors to achieve a very high capacitance volumetric efficiency. The reliability of BME and PME capacitors was investigated using highly accelerated life testing (HALT). Most BME capacitors were found to fail with an early avalanche breakdown, followed by a regular dielectric wearout failure during the HALT test. When most of the early failures, characterized with avalanche breakdown, were removed, BME capacitors exhibited a minimum mean time-to-failure (MTTF) of more than 105 years at room temperature and rated voltage. Dielectric thickness was found to be a critical parameter for the reliability of BME capacitors. The number of stacked grains in a dielectric layer appears to play a significant role in determining BME capacitor reliability. Although dielectric layer thickness varies for a given rated voltage in BME capacitors, the number of stacked grains is relatively consistent, typically around 12 for a number of BME capacitors with a rated voltage of 25V. This may suggest that the number of grains per dielectric layer is more critical than the thickness itself for determining the rated voltage and the life expectancy of the BME capacitor. The leakage current characterization and the failure analysis results suggest that most of these early avalanche failures are due to the extrinsic minor construction defects introduced during fabrication of BME capacitors. The concentration of the extrinsic defects must be reduced if the BME capacitors are considered for high reliability applications. There are two approaches that can reduce or prevent the occurrence of early failure in BME capacitors: (1) to reduce the defect concentration with improved processing control; (2) to prevent the use of BME capacitors under harsh external stress levels so that the extrinsic defects will never be triggered for a failure. In order to do so appropriate dielectric layer thickness must be determined for a given rated voltage.

Liu, David (Donhang)↗

A Tale of Two Chambers: Iterative Approaches and Lessons Learned from Life Support Systems Testing in Altitude Chambers

With a brand new fire set ablaze by a serendipitous convergence of events ranging from a science fiction novel and movie ("The Martian"), to ground-breaking recent discoveries of flowing water on its surface, the drive for the journey to Mars seems to be in a higher gear than ever before. We are developing new spacecraft and support systems to take humans to the Red Planet, while scientists on Earth continue using the International Space Station as a laboratory to evaluate the effects of long duration space flight on the human body. Written from the perspective of a facility test director rather than a researcher, and using past and current life support systems tests as examples, this paper seeks to provide an overview on how facility teams approach testing, the kind of information they need to ensure efficient collaborations and successful tests, and how, together with researchers and principal investigators, we can collectively apply what we learn to execute future tests.

Callini, Gianluca↗

Development of nickel-metal hydride cell: An update

This paper presents in viewgraph format an overview of NASDA's evaluation of commercial nickel metal-hydride (Ni-MH) cells and the development and testing of Ni-MH cells for use in space. The commercial cells are concluded to be feasible and suitable for use in LEO; for GEO, the durability for overcharge is needed because long-term charge retention is required. For the aerospace Ni-MH cell design, two activation procedures are applied to evaluate the effect of the difference in the amount of overcharge protection and precharge. Specific energy of the Ni-MH cell is nearly accomplished at 50 Wh/kg. Initial characteristics indicate the effect derived from precharge. Thirty-five amp-hour class Ni-MH cells have good performance for LEO cycle of 25 and 40 percent DOD up to 3000 cycles as similar to commercial cells. The effect of the difference in the amount of overcharge protection will appear in life test.

Kuwajima, S.↗

Evaluation of 10V Chip Polymer Tantalum Capacitors for Space Applications

Due to low ESR and safe failure mode, new technology chip polymer tantalum capacitors (CPTC) have gained popularity in the electronics design community, first in commercial applications, and now in hi-rel and space systems. The major drawbacks of these parts are high leakage currents, degradation under environmental stresses, and a relatively narrow temperature range of operating and storage conditions. Several studies have shown that a certain amount of moisture in polymer cathodes is necessary for a normal operation of the parts. This might limit applications of CPTCs in space systems and requires analysis of long-term exposure to deep vacuum conditions on their performance and reliability. High leakage currents and limited maximum operational temperature complicate accelerated testing that is necessary to assess long-term reliability and require new screening and qualification procedures for quality assurance. A better understanding of behavior of CPTCs as compared to traditional, MnO2, capacitors is necessary to develop adequate approaches for QA system for space applications. A specific of CPTCs is that different materials and processes might be used for low-voltage (10 V and less) and high-voltage (above 10 V) capacitors, so performance and degradation processes in these groups require separate analysis. In this work, that is a part of the NASA Electronic Parts and Packaging (NEPP) program, degradation of AC and DC characteristics under environmental stresses at different temperatures and voltages have been studied in nine lots of commercial and automotive grade capacitors rated to 10 V. Results of analysis of leakage currents, high temperature storage (HTS) up to 5000 hrs in vacuum and air at different temperatures, and Highly Accelerated Life Testing (HALT) in the range from 85 C to 145 C are presented. Temperature and voltage acceleration factors were calculated based on approximation of distributions of degradation rates with a general log-linear Weibull model. Mechanisms of degradation and failures, and requirements for screening and qualification testing are discussed.

Tantalum Capacitors↗

Space station environmental control and life support systems test bed program - An overview

The successful demonstration of the maturity of the regenerative Environmental Control and Life Support System (ECLSS) is an essential factor in the development of the Space Station. The present paper provides an overview of the Space Station ECLSS Test Bed Program, the mechanism by which the maturity of regenerative ECLSS technologies is demonstrated. Attention is given to the background regarding the ECLSS development, the purpose of the Space Station ECLSS Test Bed Program, the objectives of this program, the three facility elements of the ECLS Test Bed, the technical approach, the design support test phase, the testing of the Regenerative Life Support Equipment (RLSE) systems, advanced prototype testing, fallback testing, and the integrated test phase. The integrated test phase will provide the final demonstration of the regenerative ECLSS technology maturity.

Behrend, A. F., Jr.↗

Effect of Reverse Bias Stress on Leakage Currents and Breakdown Voltages of Solid Tantalum Capacitors

The majority of solid tantalum capacitors are produced by high-temperature sintering of a fine tantalum powder around a tantalum wire followed by electrolytic anodization that forms a thin amorphous Ta2O5 dielectric layer and pyrolysis of manganese nitrite on the oxide to create a conductive manganese dioxide electrode. A contact to tantalum wire is used as anode terminal and to the manganese layer as a cathode terminal of the device. This process results in formation of an asymmetric Ta -- Ta2O5 -- MnO2 capacitor that has different characteristics at forward (positive bias applied to tantalum) and reverse (positive bias applied to manganese cathode) voltages. Reverse bias currents might be several orders of magnitude larger than forward leakage currents so I-V characteristics of tantalum capacitors resemble characteristics of semiconductor rectifiers. Asymmetric I-V characteristics of Ta -- anodic Ta2O5 systems have been observed at different top electrode materials including metals, electrolytes, conductive polymers, and manganese oxide thus indicating that this phenomenon is likely related to the specifics of the Ta -- Ta2O5 interface. There have been multiple attempts to explain rectifying characteristics of capacitors employing anodic tantalum pentoxide dielectrics. A brief review of works related to reverse bias (RB) behavior of tantalum capacitors shows that the mechanism of conduction in Ta -- Ta2O5 systems is still not clear and more testing and analysis is necessary to understand the processes involved. If tantalum capacitors behave just as rectifiers, then the assessment of the safe reverse bias operating conditions would be a relatively simple task. Unfortunately, these parts can degrade with time under reverse bias significantly, and this further complicates analysis of the I-V characteristics and establishing safe operating areas of the parts. On other hand, time dependence of reverse currents might provide additional information for investigation of the processes under reverse bias conditions. In practice, there were instances when, due to unforeseen events, the system operated at conditions when capacitors experience periodically a relatively small reverse bias for some time followed by normal, forward bias conditions. In such a case an assessment should be made on the degree to which these capacitors are degraded by application of low-voltage reverse bias, and whether this degradation can be reversed by normal operating conditions. In this study, reverse currents in different types of tantalum capacitors were monitored at different reverse voltages below 15%VR and temperatures in the range from room to 145 C for up to 150 hours to get better understanding of the degradation process and determine conditions favorable to the unstable mode of operation. The reversibility of RB degradation has been evaluated after operation of the capacitors at forward bias conditions. The effect of reverse bias stress (RBS) on reliability at normal operating conditions was evaluated using highly accelerated life testing at voltages of 1.5VR and 2 VR and by analysis of changes in distributions of breakdown voltages. Possible mechanisms of RB degradation are discussed.

Teverovsky, Alexander A.↗

Effect of Gd-doped ceria infiltration into Ni-YSZ on reversible solid oxide cell operation

Gadolinium doped ceria (GDC) infiltration into Ni-(Y 2 O 3 ) 0•08 (ZrO 2 ) 0.92 (Ni-YSZ) fuel electrodes has been shown to significantly improve solid oxide electrolysis cell performance and stability. However, the effects of GDC infiltration on cells operated reversibly between fuel cell and electrolysis modes have not been reported previously. Here we present reversible solid oxide cell life test results for different GDC infiltration loadings into Ni-YSZ electrodes in two types of fuel-electrode-supported solid oxide cells. Electrochemical impedance spectroscopy reveals that GDC infiltrant lowers the initial cell area specific resistance (ASR) and limits the degradation – for example, the GDC-infiltrated electrode ASR increased by 0.1 Ω cm 2 over 1000 h of reversible operation at ±0.5 A cm –2 and 800 °C, compared to 0.19 Ω cm 2 for non-infiltrated cells. Cell voltage degradation rates were reduced by infiltration during operation at a current density of ±0.5 A cm –2 at 800 °C, and during at 700 °C at ±0.75 A cm –2 . Furthermore, scanning electron microscopy observations show that the infiltrated GDC nanoparticles mitigate Ni particle coarsening in the Ni-YSZ electrode, possibly explaining the enhanced cell stability.

25 ENERGY STORAGE↗

Long operating lifetime mid-infrared LEDs based on black phosphorus

Abstract Black phosphorus (BP) is a narrow bandgap layered semiconductor promising for mid-infrared optoelectronic applications. BP-based devices have been shown to surpass state-of-the-art mid-infrared detectors and light-emitting diodes (LEDs) in terms of performance. Despite their device advantages, the material’s inherent instability in the air could hinder its use in practical optoelectronic applications. Here, we investigated the impact of passivation on the device lifetime of BP LEDs, which deteriorate in a matter of seconds without using passivation. The lifetime is significantly extended with an Al 2 O 3 passivation layer and nitrogen packaging via atomic layer deposition and ultra-violet curable resin sealing. The operational lifetime (half-life) at room temperature is extrapolated to be ~15,000 h with an initial power density of 340 mW/cm 2 based on accelerated life testing. The present results indicate that efficient BP optoelectronics can be highly robust through simple and scalable packaging technologies, with important practical implications for mid-infrared applications.

42 ENGINEERING↗

Conditions for stable operation of solid oxide electrolysis cells: oxygen electrode effects

Solid oxide electrolysis cells (SOECs) convert renewable electricity to fuels with efficiency substantially higher than other electrolysis technologies. However, questions remain regarding degradation mechanisms that limit SOEC long-term stability. One of the key degradation mechanisms is oxygen electrode delamination; although prior studies have improved the understanding of this mechanism, it is still difficult to predict how degradation depends on SOEC materials and operating conditions, i.e., temperature, voltage, and current density. Here we present a study aimed at developing a quantitative understanding of oxygen electrode delamination. Experimentally, a life test study of symmetric and full cells with yttria-stabilized zirconia (YSZ) electrolytes and Gd-doped ceria (GDC) barrier layers was done with three different perovskite oxygen electrode materials. Fracture was observed at the perovskite–GDC interface above a critical current density and below a critical operating temperature. A theory is presented that combines a calculation of the effective oxygen pressure across the electrolyte with an estimation of the pressure required for fracture. Fracture is correctly predicted for a critical oxygen partial pressure of ~7200 atm and an associated electrode overpotential of ~0.2 V, occurring at the electrode/GDC interface because of the relatively low perovskite fracture toughness. As a result, damage at the GDC/YSZ interface was also observed in some cases and explained by a peak in the oxygen pressure at this interface.

30 DIRECT ENERGY CONVERSION↗

Tuning electrochemical and transport processes to achieve extreme performance and efficiency in solid oxide cells

Solid oxide cells (SOCs) have important applications as fuel cells and electrolyzers. The application for storage of renewable electricity is also becoming increasingly relevant; however, it is difficult to meet stringent area-specific resistance (ASR) and long-term stability targets needed to achieve required efficiency and cost. Here we show a new SOC that utilizes a very thin Gd-doped ceria (GDC)/yttria-stabilized zirconia (YSZ) bi-layer electrolyte, Ni–YSZ cell support with enhanced porosity, and electrode surface modification using PrO x and GDC nanocatalysts to achieve unprecedented low ASR values < 0.1 Ω cm 2 , fuel cell power density ~3 W cm –2 , and electrolysis current density ~4 A cm –2 at 800 °C. Besides this exceptionally high performance, fuel cell and electrolysis life tests suggest very promising stability in fuel cell and steam electrolysis modes. Furthermore, electrochemical impedance spectroscopy analysis done using a novel impedance subtraction method shows how rate-limiting electrode processes are impacted by the new SOC materials and design.

25 ENERGY STORAGE↗

Chemical stability investigation of haloolefin refrigerants and their blends with lubricants

This paper examines the findings of highly accelerated life tests (HALT), conducted according to ASHRAE Standard 97 sealed glass tube methodology for R-123 like, R-134a like and R-410A/R-404A like lower global warming potential (GWP) alternatives. Additionally, possible chemical breakdown pathways are reviewed for the new haloolefin refrigerants. Note, compositions for the following blends are shown as percent by weight. For R-123 like refrigerants, R-1336mzz(Z), R-1336mzz(E), R-514A (74.7% R-1336mzz(Z)/25.3% R-1130(E)), R-1233zd(E), and R-1224yd(Z) were examined with and without lubricants. R-1233zd(E) and R-1224yd(Z) were evaluated with mineral oil and the rest were evaluated with polyalkylene glycol (PAG), polyolester (POE) and polyvinyl ether (PVE) lubricants. For R-134a like refrigerants, R-1234ze(E), R-450A (42% R-134a/58% R-1234ze(E)), R-515B (91.1% R-1234ze(E)/8.9% R-227ea), R-1234yf, R-513A (56% R-1234yf/44% R-134a), and R-516A (77.5% R-1234yf/8.5% R-134a/14.0% R-152a) were examined with and without PAG, POE, and PVE lubricants. For R-410A/R-404A like, R-454B (68.9% R-32/31.1% R-1234yf), R-454C (21.5% R-32/78.5% R-1234yf), R-455A (3.0% R-744/21.5% R-32/75.5% R-1234yf), and R-468A (3.5% R-1132a/21.5% R-32/75.0% R-1234yf) were also examined with PAG, POE and PVE lubricants. R-466A (49% R-32/11.5% R-125/39.5% CF 3 I) was part of this study but will not be covered since it does not contain a haloolefin component.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Failure Mode and Effects Analysis (FMEA) for Photovoltaic Inverter

Photovoltaic (PV) inverters are critical yet vulnerable components in modern energy systems, often acting as reliability bottlenecks that increase the levelized cost of energy (LCOE). To address this, this paper presents a comprehensive Failure Mode and Effects Analysis (FMEA) tailored for PV inverters. Leveraging field data and literature, we identify failure-prone components, such as capacitors,, and relays, and prioritize their risks based on quantitative Risk Priority Numbers (RPNs). The analysis reveals that surge-induced MOV short circuits, capacitor degradation, and environmental cooling fan failures dominate the risk profile. These findings provide a targeted framework for reliability improvement, guiding future efforts in predictive diagnostics, design optimization, and accelerated life testing strategies.

14 SOLAR ENERGY↗

Module-Level Thermal Interface Material Degradation in HALT

Abstract In this study, thermal interface material (TIM) degradation is driven through highly accelerated life test (HALT) using temperature cycling with a prescribed vibrational acceleration for two commercially available materials having thermal conductivities of 6.0 and 8.5 W/m K. HALT specimens were prepared by applying TIM through a 4-mil stencil over AlSiC baseplates in the shape of those used in Wolfspeed CAS325M12HM2 power electronics modules. Baseplates were mounted onto aluminum carrier blocks with embedded thermocouples to characterize the thermal resistance across the baseplate and TIM layer. Thermal dissipation into the top of the baseplates was provided by a custom heating block, which mimics the size and placement of the die junctions in CAS325 modules, applying power loads of 200, 300, and 400 W. After initial characterization, samples were transferred to the HALT chamber with one set of samples exposed to temperature cycling only (TCO) and the other temperature cycling and vibration (TCV). Both sample sets were cycled between temperature extremes of −40 °C and 180 °C with vibrations applied at a peak acceleration of 3.21 Grms. After hundreds of cycles, samples were reevaluated to assess changes in thermal resistance to provide an accelerated measure of TIM degradation. This allows for reliability prediction of useful lifetime (illustrated in a solar inverter case study herein), as well as to provide a basis for developing an accelerated testing method to related temperature cycling to faster methods of degradation. Such techniques provide a means to develop maintenance schedules for power modules for ensuring sufficient thermal performance over the operating lifetime.

Engineering↗

Compatibility of Medium Density Polyethylene (MDPE) for Distribution of Gaseous Hydrogen

Hydrogen has emerged as a convenient energy storage medium and is being considered as an alternative for reducing the use of carbon-based fuels. Numerous projects are looking into distributing blends of natural gas and different amounts of gaseous hydrogen through the existing natural gas distribution system, which is widely composed of medium density polyethylene (MDPE) line pipes. The mechanical behavior of MDPE with hydrogen is not well understood; therefore, the effect of gaseous hydrogen on the mechanical properties of MDPE needs to be examined. In the current study, we investigate the effects of gaseous hydrogen on fatigue crack growth rate, fracture resistance, and fatigue life of MDPE in the presence of 3.4 MPa gaseous hydrogen. Fatigue crack growth behavior and fracture resistance are measured using compact tension specimens, while the fatigue life tests are carried out using circumferential notched tensile specimens. In addition, fatigue and fracture tests were conducted in air to determine the baseline properties of MDPE, which was then compared with the ones observed in gaseous hydrogen environment. After the completion of mechanical testing, fracture surfaces are also analyzed using optical and scanning electron microscopes to understand salient fracture features of MDPE with and without the presence of gaseous hydrogen.

Shrestha, Rakish↗

Components for the telstar project

The Telstar project required a variety of components and structures of high reliability. The program for obtaining these components was essentially that originated for submarine cable devices, in which designs of proven integrity were manufactured under controlled conditions, screened and aged to remove defectives, and then life tested and certified using techniques for selecting the most stable components. This program summary illustrates in principle the techniques described in detail in the body of this components section of the issue.

SUBMARINE CABLE↗

The satellite traveling-wave tube

The traveling-wave tube amplifier described provides a minimum output power of 3.5 watts at 4.0 to 4.2 gc. Design aspects that lead to lifetimes in excess of 10 years and to tube efficiencies between 35 to 40 per cent are discussed. The tube is focused by an improved version of the single-reversal magnetic circuit. Performance data pertinent to this particular satellite operation are shown. Highlights from the final production run and the subsequent life test serve to illustrate the care with which this TWT has been built.

TELSTAR SATELLITE↗