Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

New Developments in LC-MS and Other Hyphenated Techniques

Extensive challenges faced by analytical chemists in studying real world complex samples such as biological body fluids, tissue samples, environmental and geological samples have lead to the development of advanced analytical approaches. The vast array of contemporary technologies can be categorized into two major areas: sample separation and mass spectrometry analysis. Current state-of-the-art sample separation methods include gas chromatography, high performance liquid chromatography, ultra high pressure liquid chromatography, solid phase extraction, capillary electrophoresis, and gas phase separation techniques such as ion mobility spectrometry. The recent trend in sample separation is to combine (or hyphenate) multiple techniques that employ different separation mechanisms to maximize separation efficiency. The most widely used combinations include two-dimensional gas chromatography, strong cation exchange or weak cation exchange chromatography followed by reversed-phase liquid chromatography, two-dimensional reversed-phase liquid chromatography, liquid chromatography followed by ion mobility spectrometry and two-dimensional electrophoresis techniques. The introduction of atmospheric pressure ionization techniques such as electrospray ionization and matrix assisted laser desorption ionization and variations of the two have drastically increased the impact of mass spectrometry on bioanalytical applications. Mass spectrometry itself has tremendously improved over the years in terms of sensitivity, detection limits, dynamic range and sequencing capabilities. Currently, mass spectrometers can attain zeptomolole detection limits with five orders of magnitude dynamic range. In this chapter, we summarize recent developments in hyphenated techniques and their applications to complex sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated experimental studies of pore structure and fluid uptake in the Bossier Shale in eastern Texas, USA

Within the Haynesville-Bossier Shale complex, the Bossier Shale has not been extensively studied by either industry and academia, despite it being an unconventional gas reservoir and a potential caprock for carbon storage in the underlaying Haynesville Shale. The lack of knowledge of the complex pore structures and fluid-rock interactions hinders the effective extraction of gas and the characterization of fluid reservoirs and sealing capacity. Integrated experimental studies of pore structure and fluid-rock interactions were conducted in seven Bossier Shale core samples collected in eastern Texas. Petrographic, geochemical, and petrophysical properties such as mineral composition, organic richness, thermal maturity, porosity, pore/pore throat diameter distribution, water-accessible pores, liquid water imbibition, and water vapor adsorption were characterized using complementary approaches of thin-section petrography, scanning electron microscopy, X-ray diffraction, total organic matter, pyrolysis, mercury intrusion porosimetry, nuclear magnetic resonance, (Ultra-) small angle X-rays scattering as well as small angle neutron scattering with deuterated liquids and contrast variation. Further, the results show that the thermally mature Bossier Shales are composed of mixed argillaceous mudstone, mixed mudstone, and mixed carbonate mudstone. The shale contains both organic and inorganic pores, with porosities of 3.24-9.37 %, pore-to-throat ratios of 1.65 to 19.4, and water-accessible pores accounting for 28.7-72.6 % of total pores. Approaches of liquid water imbibition and water vapor adsorption, with and without direct contact of water with shale samples, indicate that liquid water first enters the nano-sized pores under high capillary pressures, and water vapor adsorption is mainly controlled by both clay minerals and pores with diameters less than 10 nm. These findings contribute to a better understanding of pore structures and water-shale interactions and their controlling factors in the Bossier Shale.

58 GEOSCIENCES↗

Solution scattering at the Life Science X-ray Scattering (LiX) beamline

This work reports the instrumentation and software implementation at the Life Science X-ray Scattering (LiX) beamline at NSLS-II in support of biomolecular solution scattering. For automated static measurements, samples are stored in PCR tubes and grouped in 18-position sample holders. Unattended operations are enabled using a six-axis robot that exchanges sample holders between a storage box and a sample handler, transporting samples from the PCR tubes to the X-ray beam for scattering measurements. The storage box has a capacity of 20 sample holders. At full capacity, the measurements on all samples last for ∼9 h. For in-line size-exclusion chromatography, the beamline-control software coordinates with a commercial high-performance liquid chromatography (HPLC) system to measure multiple samples in batch mode. The beamline can switch between static and HPLC measurements instantaneously. In all measurements, the scattering data span a wide q -range of typically 0.006–3.2 Å −1 . Functionalities in the Python package py4xs have been developed to support automated data processing, including azimuthal averaging, merging data from multiple detectors, buffer scattering subtraction, data storage in HDF5 format and exporting the final data in a three-column text format that is acceptable by most data analysis tools. These functionalities have been integrated into graphical user interfaces that run in Jupyter notebooks, with hooks for external data analysis software.

60 APPLIED LIFE SCIENCES↗

Highly efficient visible-light-induced photocatalytic activity of Bi{sub 2}WO{sub 6}/BiVO{sub 4} heterojunction photocatalysts

Highlights: • Bi{sub 2}WO{sub 6}/BiVO{sub 4} heterojunction photocatalysts were obtained using hydrothermal method. • Physicochemical properties played a significant role on photocatalytic efficiency. • Bi{sub 2}WO{sub 6}/BiVO{sub 4} heterogeneous structures were greatly enhanced for degradation of MB. • A tentative mechanism of charge transfer process in MB degradation was proposed. - Abstract: The Bi{sub 2}WO{sub 6}/BiVO{sub 4} heterojunction photocatalysts were synthesized by hydrothermal method. Physical properties of the heterojunction photocatalyst samples were studied by X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM) techniques. The XRD results indicated that BiVO{sub 4} retain monoclinic and tetragonal structures, while Bi{sub 2}WO{sub 6} presented as orthorhombic structure. The Brunauer, Emmett and Teller (BET) adsorption–desorption of nitrogen gas for specific surface area determination at the temperature of liquid nitrogen was performed on all samples. UV–vis diffuse reflectance spectra (UV–vis DRS) were used to identify the absorption range and band gap energy of the heterojunction photocatalysts. The photocatalytic performance of Bi{sub 2}WO{sub 6}/BiVO{sub 4} heterojunction photocatalysts was studied via the photodegradation of methylene blue (MB) under visible light irradiation. The results indicated that the heterojunction photocatalyst at 0.5:0.5 mole ratio of Bi{sub 2}WO{sub 6}:BiVO{sub 4} shows the highest photocatalytic activity.

36 MATERIALS SCIENCE↗

MEASUREMENT OF THE CHARGED-CURRENT INCLUSIVE ELECTRON NEUTRINO AND ELECTRON ANTINEUTRINO CROSS SECTION USING THE MICROBOONE DETECTOR IN THE NUMI BEAM

Detection of electron neutrino appearance is the process by which modern neutrino experiments seek to answer the open questions in neutrino physics: CP-violation in the neutrino sector, the neutrino mass ordering, and sterile neutrino oscillations. To date, only three measurements of electron neutrino cross sections have been performed. The analysis presented in this thesis describes the extraction of the first charged-current inclusive $\nu_e$ + $\bar{\nu}_e$ cross section on argon. This calculation was performed with data collected by the MicroBooNE liquid argon time projection chamber using neutrinos from the Neutrino Main Injector (NuMI) beam located at the Fermi National Accelerator Laboratory. Extraction of this cross section is enabled by the first fully-automated inclusive selection of $\nu_e$ + $\bar{\nu}_e$ charged-current interactions in a liquid argon time projection chamber, which provided the largest sample of $\nu_e$ + $\bar{\nu}_e$ charged-current interactions ever observed in liquid argon. The selection utilises the signature capabilities of liquid argon, such as distinguishing electron-like and photon-like electromagnetic showers using their charge-deposition profiles (dE/dx). The evaluation of systematic effects influencing the final cross section, including detector simulation and flux simulation uncertainties, which have been applied for the first time to a MicroBooNE analysis using neutrinos from the NuMI beam, is also presented. The total impact of all systematic and statistical effects results in a 38.44\% uncertainty on the flux integrated cross section, giving $\sigma_{\nu_{e}~+~\bar{\nu}_e} = 4.67 \pm 1.01 \textrm{(stat)} \pm 1.48 \textrm{(sys)} \times 10^{-39}$ cm$^{2}$ per nucleon as the final result, which is in agreement with theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Liquid-induced damping of mechanical feedback effects in single electron tunneling through a suspended carbon nanotube

In single electron tunneling through clean, suspended carbon nanotube devices at low temperature, distinct switching phenomena have regularly been observed. These can be explained via strong interaction of single electron tunneling and vibrational motion of the nanotube. We present measurements on a highly stable nanotube device, subsequently recorded in the vacuum chamber of a dilution refrigerator and immersed in the {sup 3}He/ {sup 4}He mixture of a second dilution refrigerator. The switching phenomena are absent when the sample is kept in the viscous liquid, additionally supporting the interpretation of dc-driven vibration. Transport measurements in liquid helium can thus be used for finite bias spectroscopy where otherwise the mechanical effects would dominate the current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An in situ approach to study trace element partitioning in the laser heated diamond anvil cell

Data on partitioning behavior of elements between different phases at in situ conditions are crucial for the understanding of element mobility especially for geochemical studies. Here, we present results of in situ partitioning of trace elements (Zr, Pd, and Ru) between silicate and iron melts, up to 50 GPa and 4200 K, using a modified laser heated diamond anvil cell (DAC). This new experimental set up allows simultaneous collection of x-ray fluorescence (XRF) and x-ray diffraction (XRD) data as a function of time using the high pressure beamline ID27 (ESRF, France). The technique enables the simultaneous detection of sample melting based to the appearance of diffuse scattering in the XRD pattern, characteristic of the structure factor of liquids, and measurements of elemental partitioning of the sample using XRF, before, during and after laser heating in the DAC. We were able to detect elements concentrations as low as a few ppm level (2-5 ppm) on standard solutions. In situ measurements are complimented by mapping of the chemical partitions of the trace elements after laser heating on the quenched samples to constrain the partitioning data. Our first results indicate a strong partitioning of Pd and Ru into the metallic phase, while Zr remains clearly incompatible with iron. This novel approach extends the pressure and temperature range of partitioning experiments derived from quenched samples from the large volume presses and could bring new insight to the early history of Earth.

36 MATERIALS SCIENCE↗

A prospective feasibility study evaluating the role of multimodality imaging and liquid biopsy for response assessment in locally advanced rectal carcinoma

Purpose: Colorectal cancer is a commonly encountered disease that poses several diagnostic and therapeutic challenges. The inherent heterogeneity of tumor biology and propensity to relapse despite “curative” resection pose significant challenges with regard to response assessment. Although MR imaging already plays a key role in primary staging of patients with rectal carcinoma, its reliability in restaging after neoadjuvant therapy is debatable (Van der broek et al. in Dis Colon Rectum 60(3):274–283, 2017). Therefore, there is significant interest in developing additional methods which may improve diagnostic accuracy. This study aims to evaluate the role of multimodality imaging and liquid biopsy in therapeutic response assessment. Methods: Seventeen patients were enrolled into the study over a span of 24 months. All underwent hybrid PET-MRI and CT-perfusion (CT-P), prior to and following neoadjuvant therapy for locally advanced rectal carcinoma. Twelve of the 17 patients also underwent liquid biopsy, which consisted of blood sampling and analysis of circulating tumor cells (CTCs) and extracellular vesicles (EVs), including cell fragments and microparticles (MPs), using the Cell Search System (Menarini Silicon Biosystems). SUV, DWI, and ADC were calculated during PET-MRI, and several parameters were evaluated during CT-perfusion, including average perfusion, blood flow (BF), blood volume (BV), mean transit time (MTT), permeability-surface area product (PS), contrast extraction efficiency (E), and K-trans (K). Changes observed pre- and post-neoadjuvant therapy in each modality were compared to tumor response at histopathology using a modified Ryan tumor regression grading system. Results: Of the 17 patients included in the study, 14 were classified as non-responders, and 3 were classified as responders as determined by the modified Ryan Tumor Regression Grade (TRG) scoring system (Van der broek et al. in Dis Colon Rectum 60(3):274–283, 2017). When combined, blood markers and CT-P parameters (mean transit time (MTT), K-trans, and permeability-surface area product (PS)) produced the strongest models (p < 0.01). PET (SUV measurement) combined with CT-P-derived K-trans produced a marginally significant (p = 0.057) model for predicting response. MRI-derived ADC value did not provide a significant model for response prediction. Conclusion: A model of CT-P parameters plus liquid biopsy more accurately predicts tumor response than PET-MRI, CT-P alone, or liquid biopsy alone. These results suggest that in the evaluation of treatment response, liquid biopsy could provide additional information to functional imaging modalities such as CT-P and should therefore be explored further in a trial with larger sample size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of titania inverse opals prepared by two distinct infiltration approaches

Highlights: • Preparation, characterization, and comparison of two types of titania inverse opals (IOs). • Infiltration is the key-step for producing IOs with improved optical, photonic, mechanical, and photocatalytic properties. • An innovative methodology for the infiltration with already prepared dispersed titania nanoparticles. - Abstract: Titanium dioxide inverse opals were prepared by the typical method of infiltration with a liquid precursor (LP-IOs) and by an improved method in which the infiltration step is done with a suspension of TiO{sub 2} nanoparticles (NP-IOs). A thorough characterization study was performed on both types of preparations in order to highlight the differences between the resulting inverse opal samples. The formation of a compact overlayer in LP-IO samples inherent to the use of a liquid precursor proved to be detrimental for the optical and photonic properties of the inverse opals. NP-IO samples, on the other hand, showed improved optical, photonic, and mechanical properties. The photocatalytic degradation of a model compound (a well-known dye, methylene blue) revealed that NP-IO samples are able to degrade the model compound at a higher rate due to the absence of the compact overlayer which acts as a mass and light blocking barrier.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Immobilization of Candida antarctic Lipase B on Functionalized Ionic Liquid Modified MWNTs

Multiwalled carbon nanotubes (MWNTs) were modified by imidazole-based ionic liquids with different alkyl groups. The modified support samples were characterized by scanning transmission electron microscopy, Raman spectra, thermogravimetric analyses, and X-ray photoelectron spectroscopy. The samples were used to immobilize Candida antarctic lipase (CALB) and the influence of alkyl chain length of ionic liquids on enzymatic properties was investigated by the hydrolysis reaction of triacetin. The results revealed that functionalized ionic liquids modification did not destroy the structure of MWNTs. Compared with the immobilized CALB on MWNTs, the immobilized CALB on novel carriers all exhibited higher activity, thermal stability, and reusability. Especially, the activity of MWNTs-IL (8C)-CALB improved 15.23-folds than MWNTs-CALB, meanwhile, after incubation at 70 °C for 20 min, residual enzyme activity of MWNTs-IL (8C)-CALB was 46% of the initial activity, while MWNTs-CALB already lost all activity. Besides, MWNTs-IL (8C)-CALB retained 64.5% of its initial activity after 4 cycles, while MWNTs-CALB retained only 2.12%. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ultra-trace determination of Strontium-90 in environmental soil samples from Qatar by collision/reaction cell-inductively coupled plasma mass spectrometry (CRC-ICP-MS/MS)

Because of the very low level of {sup 90}Sr in the environmental soil samples and its determination by beta counting may take several weeks, we developed a procedure for ultra-trace determination of {sup 90}Sr using collision reaction cell-inductively coupled plasma tandem mass spectrometry (CRC-ICP-MS/MS, Agilent 8800). Soil samples were dried at 105 deg. C and then heated in a furnace at 550 deg. C to remove any organics present. 500 g of each soil samples were aliquoted into 2000 ml glass beakers. Each Soils samples were soaked in 2 ppm Sr solution carrier to allow determination of chemical yield. The solid to liquid ratio was 1:1. Finally the soil samples were dried at 105 deg. C. Five hundred milliliters concentrated nitric acid and 250 ml hydrochloric acid volumes were added on 500 g soil samples. The samples were digested on hot plate at 80 deg. C to prevent spraying with continuous manual mixing. The leachate solution was separated. The solids were rinsed with 500 ml deionized water, warmed on a hot plate and the leachate plus previous leachate were filtered and the total volume was reduced to 500 ml by evaporation. Final leachate volume was transferred to a centrifuge tubes. The centrifuge tubes were centrifuged at 3,500 rpm for 10 min. The leachate was transferred to a 1 L beaker and heated on a hot plate to evaporate the leachate to dryness. The reside was re-dissolved in 100 ml of 2% HNO{sub 3} and reduced by evaporation to 10 mL. The solution was measured directly by CRC-ICP-MS/MS by setting the first quadruple analyzer to m/z 90 and introducing oxygen gas into the reaction cell for elimination isobar interference from zirconium-90. The method was validated by measurements of standard reference materials and applied on environmental soil samples. The overall time requirement for the measurement of strontium-90 by CRC-ICP-MS/MS is 2 days, significantly shorter than any radioanalytical protocol currently available. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A unified parameterization of clouds and turbulence using CLUBB and subcolumns in the Community Atmosphere Model

Most global climate models parameterize separate cloud types using separate parameterizations. This approach has several disadvantages, including obscure interactions between parameterizations and inaccurate triggering of cumulus parameterizations. Alternatively, a unified cloud parameterization uses one equation set to represent all cloud types. Such cloud types include stratiform liquid and ice cloud, shallow convective cloud, and deep convective cloud. Vital to the success of a unified parameterization is a general interface between clouds and microphysics. One such interface involves drawing Monte Carlo samples of subgrid variability of temperature, water vapor, cloud liquid, and cloud ice, and feeding the sample points into a microphysics scheme.This study evaluates a unified cloud parameterization and a Monte Carlo microphysics interface that has been implemented in the Community Atmosphere Model (CAM) version 5.3. Results describing the mean climate and tropical variability from global simulations are presented. The new model shows a degradation in precipitation skill but improvements in short-wave cloud forcing, liquid water path, long-wave cloud forcing, precipitable water, and tropical wave simulation. Also presented are estimations of computational expense and investigation of sensitivity to number of subcolumns.

58 GEOSCIENCES↗

Microbial Gas Generation Under Expected Waste Isolation Pilot Plant Repository Conditions: Final Report

Gas generation from the microbial degradation of the organic constituents of transuranic (TRU) waste under conditions expected in the Waste Isolation Pilot Plant (WIPP) was investigated. The biodegradation of mixed cellulosic materials and electron-beam irradiated plastic and rubber materials (polyethylene, polyvinylchloride, hypalon, leaded hypalon, and neoprene) was examined. We evaluated the effects of environmental variables such as initial atmosphere (air or nitrogen), water content (humid ({approx}70% relative humidity, RH) and brine inundated), and nutrient amendments (nitogen phosphate, yeast extract, and excess nitrate) on microbial gas generation. Total gas production was determined by pressure measurement and carbon dioxide (CO{sub 2}) and methane (CH{sub 4}) were analyzed by gas chromatography; cellulose degradation products in solution were analyzed by high-performance liquid chromatography. Microbial populations in the samples were determined by direct microscopy and molecular analysis. The results of this work are summarized.

03 NATURAL GAS↗

A unified parameterization of clouds and turbulence using CLUBB and subcolumns in the Community Atmosphere Model

Most global climate models parameterize separate cloud types using separate parameterizations. This approach has several disadvantages, including obscure interactions between parameterizations and inaccurate triggering of cumulus parameterizations. Alternatively, a unified cloud parameterization uses one equation set to represent all cloud types. Such cloud types include stratiform liquid and ice cloud, shallow convective cloud, and deep convective cloud. Vital to the success of a unified parameterization is a general interface between clouds and microphysics. One such interface involves drawing Monte Carlo samples of subgrid variability of temperature, water vapor, cloud liquid, and cloud ice, and feeding the sample points into a microphysics scheme. This study evaluates a unified cloud parameterization and a Monte Carlo microphysics interface that has been implemented in the Community Atmosphere Model (CAM) version 5.3. Model computational expense is estimated, and sensitivity to the number of subcolumns is investigated. Results describing the mean climate and tropical variability from global simulations are presented. The new model shows a degradation in precipitation skill but improvements in shortwave cloud forcing, liquid water path, long-wave cloud forcing, precipitable water, and tropical wave simulation.

54 ENVIRONMENTAL SCIENCES↗

Facile hermetic TEM grid preparation for molecular imaging of hydrated biological samples at room temperature

Abstract Although structures of vitrified supramolecular complexes have been determined at near-atomic resolution, elucidating in situ molecular structure in living cells remains a challenge. Here, we report a straightforward liquid cell technique, originally developed for real-time visualization of dynamics at a liquid-gas interface using transmission electron microscopy, to image wet biological samples. Due to the scattering effects from the liquid phase, the micrographs display an amplitude contrast comparable to that observed in negatively stained samples. We succeed in resolving subunits within the protein complex GroEL imaged in a buffer solution at room temperature. Additionally, we capture various stages of virus cell entry, a process for which only sparse structural data exists due to their transient nature. To scrutinize the morphological details further, we used individual particle electron tomography for 3D reconstruction of each virus. These findings showcase this approach potential as an efficient, cost-effective complement to other microscopy technique in addressing biological questions at the molecular level.

59 BASIC BIOLOGICAL SCIENCES↗

Analyzing the errors of DFT approximations for compressed water systems

We report an extensive study of the errors of density functional theory (DFT) approximations for compressed water systems. The approximations studied are based on the widely used PBE and BLYP exchange-correlation functionals, and we characterize their errors before and after correction for 1- and 2-body errors, the corrections being performed using the methods of Gaussian approximation potentials. The errors of the uncorrected and corrected approximations are investigated for two related types of water system: first, the compressed liquid at temperature 420 K and density 1.245 g/cm{sup 3} where the experimental pressure is 15 kilobars; second, thermal samples of compressed water clusters from the trimer to the 27-mer. For the liquid, we report four first-principles molecular dynamics simulations, two generated with the uncorrected PBE and BLYP approximations and a further two with their 1- and 2-body corrected counterparts. The errors of the simulations are characterized by comparing with experimental data for the pressure, with neutron-diffraction data for the three radial distribution functions, and with quantum Monte Carlo (QMC) benchmarks for the energies of sets of configurations of the liquid in periodic boundary conditions. The DFT errors of the configuration samples of compressed water clusters are computed using QMC benchmarks. We find that the 2-body and beyond-2-body errors in the liquid are closely related to similar errors exhibited by the clusters. For both the liquid and the clusters, beyond-2-body errors of DFT make a substantial contribution to the overall errors, so that correction for 1- and 2-body errors does not suffice to give a satisfactory description. For BLYP, a recent representation of 3-body energies due to Medders, Babin, and Paesani [J. Chem. Theory Comput. 9, 1103 (2013)] gives a reasonably good way of correcting for beyond-2-body errors, after which the remaining errors are typically 0.5 mE{sub h} ≃ 15 meV/monomer for the liquid and the clusters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new high pressure form of Ba{sub 3}NiSb{sub 2}O{sub 9}

In the search of an experimental realization of quantum spin liquid phases we have synthesized polycrystalline samples of Ba{sub 3}NiSb{sub 2}O{sub 9} under high pressure–high temperature conditions. Combining X-ray powder diffraction, neutron powder diffraction and precession electron diffraction we show that the obtained phase isn't hexagonal as reported in the literature, but trigonal. This new structure shows triangular Ni planes, but only in domains of sizes of the order of 10 nm. It therefore is still interesting as a potential candidate for a quantum spin liquid. - Graphical abstract: Synthesis under high pressure of a new form of Ba{sub 3}NiSb{sub 2}O{sub 9} : a promising candidate for a quantum spin liquid. Triangular Ni-planes can effectively be present in this structure but only in domains of up to 10 nm in size.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗