Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC DIPOLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Probing the sterile neutrino dipole portal with SN1987A and low-energy supernovae

Beyond the Standard Model electromagnetic properties of neutrinos may lead to copious production of sterile neutrinos in the hot and dense core of a core-collapse supernova. In this work, we focus on the active-sterile transition magnetic moment portal for heavy sterile neutrinos. Firstly, we revisit the SN1987A cooling bounds for dipole portal using the integrated luminosity method, which yields more reliable results (especially in the trapping regime) compared to the previously explored via emissivity loss, also known as the Raffelt criterion. Secondly, we obtain strong bounds on the dipole coupling strength reaching as low as 10 − 11 GeV − 1 from energy deposition, i.e., constrained from the observation of explosion energies of underluminous Type IIP supernovae. In addition, we find that sterile neutrino production from Primakoff upscattering off of a proton dominates over scattering off of an electron for low sterile neutrino masses. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Deep Controlled Source Electro-Magnetic Sensing: A Cost Effective, Long-Term Tool for Sequestration Monitoring

The proposed system was designed to operate as a permanent, autonomous monitoring and data collection system that can provide much higher temporal data density than can be achieved economically with 3-Dimensional (3D) seismic surveys. It can operate over broad areas for long periods of time providing full 3D data sets on a monthly basis at a very low cost. By borrowing techniques commonly used in marine CSEM, structural information from background seismic surveys can be incorporated into the CSEM modeling to provide high resolution models of CO 2 progression within reservoirs. The system uses borehole-based vertical-electric-dipole sources placed at reservoir depths in the formation. The electric and magnetic fields induced by this source are received on the surface using an array of stations. The project was conducted in three phases. Phase I demonstrated the feasibility of the system to collect static/reference data at the Ketzin CO 2 storage pilot site in Germany. In Phase I, numerical modeling was used to determine the optimal configurations and requirements for sensor sensitivity and data accuracy. Based on the model results, existing hardware and software were modified. The CSEM system was then field tested at the Ketzin site. The data were imaged and the results were compared with independent studies of the reservoir and overburden geo-electrical characteristics. Phase II demonstrated the ability to provide sensitive, cost-effective measurement of changes in reservoir properties and changes in the overlying formations using a second round of measurements at the Ketzin site. A prototype autonomous recording system was developed and tested as a subset of the measurement points. Phase III of the project quantified the advantages (and disadvantages) of the fully autonomous data collection subsystems by comparing them with repeated measurements made with mobile stations. The Phase III also provided an additional time point in measuring post-closure changes in and above the Ketzin CO 2 injection site. Validation of the CSEM field survey results were completed using a method such as other alternative and available field site data.

58 GEOSCIENCES↗

Magnetodielectric Relaxation in Ho{sub 2}Ti{sub 2}O{sub 7} and Dy{sub 2}Ti{sub 2}O{sub 7} Spin Ice

Materials having magnetoelectricity is one of the highest priority research topics for the development of novel multifunctional materials. Recently, Ho{sub 2}Ti{sub 2}O{sub 7} and Dy{sub 2}Ti{sub 2}O{sub 7} pyrochlores show the coexistence of ferroelectricity with complex magnetism. The present study shows that these spin ices show an anomalous nature of relaxation taking place at ~ 4 K. Arrhenius nature of frequency dispersion behavior and order of characteristic relaxation time τ{sub 0} suggest that observed relaxation is associated with non-interacting electric dipoles induced by lattice distortions. These lattice distortions are associated with prevailing 3in-1out spin structure via magnetostriction mechanism, thus enabling the control of ferroelectricity though magnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development and test of a large-aperture Nb3Sn cos-theta dipole coil with stress management

The stress-managed cos-theta (SMCT) coil is a new concept which was proposed and is being developed at Fermilab in the framework of US Magnet Development Program (US-MDP) for high-field and/or large-aperture accelerator magnets based on low-temperature and high-temperature superconductors. A 120-mm aperture two-layer Nb3Sn SMCT dipole coil has been developed at Fermilab to demonstrate and test the SMCT concept including coil design, fabrication technology and performance. The first SMCT demo coil was fabricated and assembled with 60-mm aperture Nb3Sn coil inside a dipole mirror configuration and tested separately and in series with the insert coil. This paper summarizes the design, parameters, and quench performance of the 120-mm aperture SMCT coil in a dipole mirror configuration.

43 PARTICLE ACCELERATORS↗

Feasibility of FDEM cross-dipole and TDEM loop sources for monitoring CO 2 at the Kemper CarbonSAFE site

Electromagnetics has been shown to be a viable tool to monitor CO 2 plumes embedded in saline reservoirs. However, the majority of studies focus on measuring the electric field, which requires cumbersome equipment in the field and it is difficult to install permanent measurement stations. Magnetic field receivers offer an opportunity to reduce the form factor of the survey and increase the mobility by utilizing upcoming technologies, such as drones. We explore the use of frequency-domain electric dipole sources, and timedomain loops with a focus on measuring the secondary magnetic field at the surface for a conceptual injection scenario based on the Kemper CarbonSAFE site. We find that electric dipole sources give a response above the sensitivity of current sensor technology and, therefore, be a viable tool for CO 2 monitoring. The time domain loop source does provide fields that are useful for determining the location of the CO 2 plume, however the field magnitude is below the sensitivity of the current generation of instruments. To explore the use of a potential borehole receiver we generate a map of the magnetic field at depth to explore potential borehole placement for monitoring efforts. Finally, we limit the spatial extent of the electric dipole survey to a single parcel of land to help understand how the fields change with survey geometry. We find that the shape of the secondary fields change slightly with the small transmitter, but are still measurable provided that the cultural noise at the site is low. Thus, we conclude that at the Kemper site a frequency-domain cross-dipole source with magnetometer receivers is suitable to monitor the expansion of the CO 2 plume in the saline reservoir, even with a limited transmitter footprint on the surface.

58 GEOSCIENCES↗

Magneto‐Photoluminescence Based on Two‐Photon Excitation in Lanthanide‐Doped Up‐Conversion Crystal Particles

Experimental studies on magneto‐photoluminescence based on two‐photon excitation in up‐conversion Y 2 O 2 S:Er, Yb crystal particles are reported. It is found that the up‐conversion photoluminescence generated by two‐photon excitation exhibits magnetic field effects at room temperature, leading to a two‐photon excitation‐induced magneto‐photoluminescence, when the two‐photon excitation exceeds the critical intensity. By considering the spin selection rule in electronic transitions, it is proposed that spin‐antiparallel and spin‐parallel transition dipoles with spin mixing are accountable for the observed magneto‐photoluminescence. Specifically, the two‐photon excitation generates spin‐antiparallel electric dipoles between 4 S 3/2 – 4 I 15/2 in Er 3+ ions. The antiparallel spins are conserved by exchange interaction within dipoles. When the photoexcitation exceeds the critical intensity, the Coulomb screening can decrease the exchange interaction. Consequently, the spin–orbital coupling can partially convert the antiparallel dipoles into parallel dipoles, generating a spin mixing. Eventually, the populations between antiparallel and parallel dipoles reach an equilibrium established by the competition between exchange interaction and spin–orbital coupling. Applying a magnetic field can break the equilibrium by disturbing spin mixing through introducing spin precessions, changing the spin populations on antiparallel and parallel dipoles and leading to the magneto‐photoluminescence. Therefore, spin‐dependent transition dipoles present a convenient mechanism to realize magneto‐photoluminescence in multiphoton up‐conversion crystal particles.

Xu, Hengxing↗

Remote Distributed Vibration Sensing Through Opaque Media Using Permanent Magnets

Vibration sensing is critical for a variety of applications from structural fatigue monitoring to understanding the modes of airplane wings. In particular, remote sensing techniques are needed for measuring the vibrations of multiple points simultaneously, assessing vibrations inside opaque metal vessels, and sensing through smoke clouds and other optically challenging environments. Here, in this paper, we propose a method which measures high-frequency displacements remotely using changes in the magnetic field generated by permanent magnets. We leverage the unique nature of vibration tracking and use a calibrated local model technique developed specifically to improve the frequency-domain estimation accuracy. The results show that two-dimensional local models surpass the dipole model in tracking high-frequency motions. A theoretical basis for understanding the effects of electronic noise and error due to correlated variables is generated in order to predict the performance of experiments prior to implementation. Simultaneous measurements of up to three independent vibrating components are shown. The relative accuracy of the magnet-based displacement tracking with respect to the video tracking ranges from 40 to 190 μm when the maximum displacements approach ±5 mm and when sensor-to-magnet distances vary from 25 to 36 mm. Finally, vibration sensing inside an opaque metal vessel and mode shape changes due to damage on an aluminum beam are also studied using the wireless permanent-magnet vibration sensing scheme.

42 ENGINEERING↗

The Muon g-2 Straw Tracking Detectors

• Built to measure the muon anomalous magnetic moment to an uncertainty of 140 ppb and search for a muon electric dipole moment. • Determine whether discrepancy from the Standard Model in the previous experiment $\Delta 𝒂_{\mu}$ 𝑬𝟖𝟐𝟏 − 𝑺𝑴 = 𝟐𝟓𝟓 ± 𝟖𝟎 ×$𝟏𝟎^{-𝟏𝟏}$ is a statistical fluctuation or indicates non-SM physics. • A muon storage ring located at Fermilab, Illinois. • 15m diameter storage ring. • 1.45T uniform magnetic field. • 24 calorimeters around the ring. • 2 tracking stations. • Storing 100s of billions of muons.

43 PARTICLE ACCELERATORS↗

Superconducting multi-cell trapped mode deflecting cavity

A method and system for beam deflection. The method and system for beam deflection comprises a compact superconducting RF cavity further comprising a waveguide comprising an open ended resonator volume configured to operate as a trapped dipole mode; a plurality of cells configured to provide a high operating gradient; at least two pairs of protrusions configured for lowering surface electric and magnetic fields; and a main power coupler positioned to optimize necessary coupling for an operating mode and damping lower dipole modes simultaneously.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Chiral properties of the nucleon interpolating current and θ-dependent observables

We revisit the chiral properties of nucleon interpolating currents, and show that of the two leading order currents j 1 and j 2 , only two linear combinations j 1 ± j 2 transform covariantly under the anomalous U⁢(1) A symmetry. As a result, calculations of quantities which vanish by symmetry in the chiral limit may produce unphysical results if carried out with different linear combinations of the currents. This includes observables such as electric dipole moments, induced by the quantum chromodynamics (QCD) parameter θ, and the θ-dependence of the nucleon mass. For completeness, we also exhibit the leading order results for nucleon electric dipole moments (d n,p ) induced by θ, and the nucleon magnetic moments (μ n,p ), when calculated using QCD sum rules for both the covariant choices of the nucleon interpolating current. The results in each channel, conveniently expressed as the ratios, d n,p /μ n,p , are numerically consistent, and reflect the required physical dependence on θ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast Transverse Beam Instability Caused by Electron Cloud Trapped in Combined Function Magnets

Electron cloud instabilities affect the performance of many circular high-intensity particle accelerators. They usually have a fast growth rate and might lead to an increase of the transverse emittance and beam loss. A peculiar example of such an instability is observed in the Fermilab Recycler proton storage ring. Although this instability might pose a challenge for future intensity upgrades, its nature had not been completely understood. The phenomena has been studied experimentally by comparing the dynamics of stable and unstable beam, numerically by simulating the build-up of the electron cloud and its interaction with the beam, and analytically by constructing a model of an electron cloud driven instability with the electrons trapped in combined function dipoles. Stabilization of the beam by a clearing bunch reveals that the instability is caused by the electron cloud, trapped in beam optics magnets. Measurements of microwave propagation confirm the presence of the cloud in the combined function dipoles. Numerical simulations show that up to 10$^{-2}$ of the particles can be trapped by their magnetic field. Since the process of electron cloud build-up is exponential, once trapped this amount of electrons significantly increases the density of the cloud on the next revolution. In a combined function dipole this multi-turn accumulation allows the electron cloud reaching final intensities orders of magnitude greater than in a pure dipole. The estimated fast instability growth rate of about 30 revolutions and low mode frequency of 0.4 MHz are consistent with experimental observations and agree with the simulations. The created instability model allows investigating the beam stability for the future intensity upgrades.

43 PARTICLE ACCELERATORS↗

Raman Scattering as a Probe of the Magnetic State of BEDT-TTF Based Mott Insulators

Quasi-two-dimensional Mott insulators based on BEDT-TTF molecules have recently demonstrated a variety of exotic states, which originate from electron-electron correlations and geometrical frustration of the lattice. Among those states are a triangular S = 1/2 spin liquid and quantum dipole liquid. Here in this article, we show the power of Raman scattering technique to characterize magnetic and electronic excitations of these states. Our results demonstrate a distinction between a spectrum of magnetic excitations in a simple Mott insulator with antiferromagnetic interactions, and a spectrum of an insulator with an additional on-site charge degree of freedom.

36 MATERIALS SCIENCE↗

Proximity-Induced Exchange Interaction: A New Pathway for Quantum Sensing Using Spin Centers in Hexagonal Boron Nitride

Defects in hexagonal boron nitride (hBN), a two-dimensional van der Waals material, have attracted a great deal of interest because of its potential in various quantum applications. Due to hBN’s two-dimensional nature, the spin center in hBN can be engineered in the proximity of the target material, providing advantages over its three-dimensional counterparts, such as the nitrogen-vacancy center in diamond. Here, in this work, we propose a novel quantum sensing protocol driven by exchange interaction between the spin center in hBN and the underlying magnetic substrate induced by the magnetic proximity effect. By first-principles calculation, we demonstrate that the induced exchange interaction dominates over the dipole–dipole interaction by orders of magnitude when in the proximity. The interaction remains antiferromagnetic across all stacking configurations between the spin center in hBN and the target van der Waals magnets. Additionally, we explored the scaling behavior of the exchange field as a function of the spatial separation between the spin center and the targets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Printed Circuit Board Based Rotating Coils for Measuring Sextupole Magnets

Here, the use of Printed Circuit Boards (PCBs) for the inductive pick-up windings of rotating coil probes has made the construction of these precision magnetic measurement devices much more accessible. This paper discusses the design details for PCBs which on each layer of the board provide for simultaneous analog bucking (suppression) of dipole, quadrupole, and sextupole field components so as to more accurately measure the higher order harmonic fields in sextupole magnets. Techniques to generate designs are discussed, as well as trade-offs to optimize sensitivity. Examples of recent sextupole PCBs and their performance are given.

43 PARTICLE ACCELERATORS↗

A Search for Neutron to Mirror Neutron Oscillation Using Neutron Electric Dipole Moment Measurements

Baryon number violation is a key ingredient of baryogenesis. It has been hypothesized that there could also be a parity-conjugated copy of the standard model particles, called mirror particles. The existence of such a mirror universe has specific testable implications, especially in the domain of neutral particle oscillation, viz. the baryon number violating neutron to mirror-neutron (n−n′) oscillation. Consequently, there were many experiments that have searched for n−n′ oscillation, and imposed constraints upon the parameters that describe it. Recently, further analysis on some of these results have identified anomalies which could point to the detection of n−n′ oscillation. All the previous efforts searched for n−n′ oscillation by comparing the relative number of ultracold neutrons that survive after a period of storage for one or both of the two cases: (i) comparison of zero applied magnetic field to a non-zero applied magnetic field, and (ii) comparison where the orientation of the applied magnetic field was reversed. However, n−n′ oscillations also lead to variations in the precession frequency of polarized neutrons upon flipping the direction of the applied magnetic field. Precession frequencies are measured, very precisely, by experiments searching for the electric dipole moment. For the first time, we used the data from the latest search for the neutron electric dipole moment to constrain n−n′ oscillation. After compensating for the systematic effects that affect the ratio of precession frequencies of ultracold neutrons and cohabiting 199Hg-atoms, chief among which was due to their motion in non-uniform magnetic field, we constrained any further perturbations due to n−n′ oscillation. We thereby provide a lower limit on the n−n′ oscillation time constant of τnn′/|cos(β)|>5.7s,0.36T′

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of Magnetic Confinement on the Yellow Excitons in Cuprous Oxide Subject to an Electric Field

We study the spectrum of the yellow exciton series in crossed electric and magnetic fields. The electric field, applied along the optical axis, tilts the Coulomb potential between electron and hole, so that at sufficiently high fields exciton dissociation becomes possible, roughly when the electric dipole interaction energy exceeds the binding energy of an exciton state with principal quantum number n. For an applied voltage of U = 20 V all excitons above n = 6 are dissociated. Additional application of a magnetic field normal to the optical axis introduces magnetic confinement, due to which above a threshold field strength around B = 2.5 T the exciton lines re-emerge. The complex dispersion with increasing fields suggests quantum chaotic behavior in this crossed field configuration, so that the search for exceptional points may be promising.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quench performance and field quality of FNAL twin-aperture 11 T Nb 3 Sn dipole model for LHC upgrades

A 2 m long single-aperture dipole demonstrator and two 1 m long single-aperture models based on Nb 3 Sn superconductor have been built and tested at FNAL. The two 1 m long collared coils were then assembled in a twin-aperture Nb 3 Sn dipole demonstrator compatible with the LHC main dipole and tested in two thermal cycles. This paper summarizes the quench performance of the FNAL twin-aperture Nb 3 Sn 11 T dipole in the temperature range of 1.9-4.5 K. The results of magnetic measurements for one of the two apertures are also presented. Test results are compared to the performance of coils in a single-aperture configuration. Lastly, a summary of quench propagation studies in both apertures is given.

43 PARTICLE ACCELERATORS↗

Magneto-Mechanical Optimization of Cross-Sections for $ \text{cos}(\theta)$Accelerator Magnets

The cross-section design of cos (θ) superconducting magnets is historically developed in a two-step process: initially, the coil geometry is defined on the basis of magnetic optimizations; then, the structure is designed around the coil. The first step searches for the best coil cross-section maximizing the magnetic field, margin, field quality and conductor efficiency. The latter step aims at limiting the coil stresses and deformations. However, the coil design, defined with the initial magnetic optimization, can influence the mechanical behaviour of the magnet, altering, for example, the peak stress during operation. As the critical current is a function of the applied strain, the mechanical implications of the coil cross-section design can limit the achievable performance. In this paper we propose an integrated optimization process that targets the peak stress on the conductor in addition to the magnetic objectives. Here the results are presented for a sample high-field Nb 3 Sn dipole: a 4-layer design aiming at ultimate conductor performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗