Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC TAPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

662 records · Page 37

Investigations of medium wavelength magnetic anomalies in the Eastern Pacific using Magsat data

Processing continued on the data set covering the first three months of the mission. Orbits were selected over a specified range of longitude and latitude and those orbits falling within the geographical boundaries were stored on a disk and a listing made. To verify the quality of the data, plots were made showing altitude vs latitude, anomalous field vs latitude, and corrected anomalous field vs latitude. Results of the plotting showed that: (1) data from the first day of the mission are not usable because they are too noisy; (2) some orbits contain spikes, no doubt a processing error on the tape; (3) some orbits contain a 20 deg region in latitude, offset roughly 30 nT from the rest of the anomalous field profiles; and (4) the correlation between the adjacent orbits is poor. Even the new ring current coefficients provided with a later, corrected set of data tapes did not not yield the desired correlations.

Harrison, C. G. A.↗

ROSAT guest investigator program (AO-1). On a search for coronal x ray emissions from white dwarfs

We have suggested that cool magnetic white dwarfs may be sources of X-ray coronal emission and proposed several prominent candidates for this emission. One of these candidates (EG 250) was approved for the C-category observation by the National and International Committee and was observed by ROSAT on April 17, 1991. Unfortunately, the granted exposure time (1071 s) was much shorter than that which was required by theoretical predictions to observe coronal X-ray emission from this object. The tape containing the data was send to us in November 1991. Since then we have analyzed the data visiting the ROSAT Science Center at NASA Goddard Space Flight Center. The analysis of the data taken during this short observation show, as expected, no X-rays. It is our hope that EG 250 will be observed again during the AO-2 phase of pointed observations, as 10,000 s of observing time was granted to V. Trimble for the C-category observation of this star. We have a close contact with Dr. Trimble regarding this matter. Because our all targets (GD 90, KUV 2316-123 and GD 356) proposed for the observation during the AO-2 phase of pointed observations have been approved by the National and International Committee, we have installed the required software at NASA/MSFC to be able to carry out the data analysis in Huntsville. Two of our targets have already been observed (KUV 2316-123 was observed on Dec. 3, 1991 with 10,000 s of the exposure time, and GD 356 was observed on Jan 4, 1992 with 5,000 s of the exposure time). We just received the data and will begin the analysis soon. The results of our analysis will be reported to the scientific community by publishing papers in the Astrophysical Journal Letters. Our intention is to submit a paper when the analysis of the data taken during AO2 is completed. The data taken during the observation of EG 250 will be a part of this paper.

Musielak, Z. E.↗

NLSI Focus Group on Recovery of Missing ALSEP Data: Status Update for 2012 NLSI Science Forum

On the six Apollo lunar landed missions, the Astronauts deployed the Apollo Lunar Surface Experiments Package (ALSEP) science stations which measured active and passive seismic events, magnetic fields, charged particles, solar wind, heat flow, the diffuse atmosphere, meteorites and their ejecta, lunar dust, etc. Today s investigators are able to extract new information and make new discoveries from the old ALSEP data utilizing recent advances in computer capabilities and new analysis techniques. However, current-day investigators are encountering problems in trying to use the ALSEP data. The data were in formats often not well described in the published reports and contained rerecording anomalies which required tape experts to resolve. To solve these problems the DPS Lunar Data Node was established at NASA Goddard Space Flight Center (GSFC) NASA Space Science Data Center (NSSDC) in 2008 and is currently in the process of making the existing archived ALSEP data available to current-day investigators in easily useable forms. However, current estimates by NSSDC archivists are that only about 60 percent of the PI processed ALSEP data and less than 30 percent of the raw experiment ALSEP data-of-interest to current lunar science investigators are currently in the NSSDC archives.

Lewis, Lyach R.↗

An investigation of the crustal properties of Australia and surrounding regions derived from interpretation of MAGSAT anomaly field data

The 2 deg averaged data set was analyzed and filtered to produce a magnetic anomaly map of the Australian continental region. The map was overlain on a tectonic map of Australia and correlations were made. A data set was selected that is dominated by relatively low elevation profiles with small changes of elevation within the Australian area in an effort to maximize the crustal anomaly field signal and reduce the effect of variation in satellite elevation. Support systems, both hardware and software are described and best-worst case errors encountered during processing of MAGSAT investigator tapes are summarized. The Broken Ridge anomaly was studied for model development purposes.

Johnson, B. D.↗

Tape casting and partial melting of Bi-2212 thick films

To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 microns. The orientation of the (a,b)-plane of the grains was parallel to the substrate with a misalignment of less than 6 deg. At 77 K/0T a critical current density of 15, 000 A/sq cm was reached in films of the dimension 1 cm x 2 cm x 20 microns (1 micron V/cm criterion, resistively measured). At 4 K/0T the highest value was 350,000 A/sq cm (1 nV/cm criterion, magnetically measured).

Buhl, D.↗

MAGSAT data processing: A report for investigators

The in-flight attitude and vector magnetometer data bias recovery techniques and results are described. The attitude bias recoveries are based on comparisons with a magnetic field model and are thought to be accurate to 20 arcsec. The vector magnetometer bias recoveries are based on comparisons with the scalar magnetometer data and are thought to be accurate to 3 nT or better. The MAGSAT position accuracy goals of 60 m radially and 300 m horizontally were achieved for all but the last 3 weeks of Magsat lifetime. This claim is supported by ephemeris overlap statistics and by comparisons with ephemerides computed with an independent orbit program using data from an independent tracking network. MAGSAT time determination accuracy is estimated at 1 ms. Several errors in prelaunch assumptions regarding data time tags, which escaped detection in prelaunch data tests, and were discovered and corrected postlaunch are described. Data formats and products, especially the Investigator-B tapes, which contain auxiliary parameters in addition to the basic magnetometer and ephemeris data, are described.

Langel, R. A.↗

NASA Tech Briefs, February 2011

Topics covered include: Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly; Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection; Photocatalytic Active Radiation Measurements and Use; Computer Generated Hologram System for Wavefront Measurement System Calibration; Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System; SpaceCube 2.0: An Advanced Hybrid Onboard Data Processor; CMOS Imager Has Better Cross-Talk and Full-Well Performance; High-Performance Wireless Telemetry; Telemetry-Based Ranging; JWST Wavefront Control Toolbox; Java Image I/O for VICAR, PDS, and ISIS; X-Band Acquisition Aid Software; Antimicrobial-Coated Granules for Disinfecting Water; Range 7 Scanner Integration with PaR Robot Scanning System; Methods of Antimicrobial Coating of Diverse Materials; High-Operating-Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength; A Model of Reduced Kinetics for Alkane Oxidation Using Constituents and Species for N-Heptane; Thermally Conductive Tape Based on Carbon Nanotube Arrays; Two Catalysts for Selective Oxidation of Contaminant Gases; Nanoscale Metal Oxide Semiconductors for Gas Sensing; Lightweight, Ultra-High-Temperature, CMC-Lined Carbon/Carbon Structures; Sample Acquisition and Handling System from a Remote Platform; Improved Rare-Earth Emitter Hollow Cathode; High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement; Cryogenic Scan Mechanism for Fourier Transform Spectrometer; Piezoelectric Rotary Tube Motor; Thermoelectric Energy Conversion Technology for High-Altitude Airships; Combustor Computations for CO2-Neutral Aviation; Use of Dynamic Distortion to Predict and Alleviate Loss of Control; Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards; and A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks.

Source record↗

Evolution of Archival Storage (from Tape to Memory)

Over the last three decades, there has been a significant evolution in storage technologies supporting archival of remote sensing data. This section provides a brief survey of how these technologies have evolved. Three main technologies are considered - tape, hard disk and solid state disk. Their historical evolution is traced, summarizing how reductions in cost have helped being able to store larger volumes of data on faster media. The cost per GB of media is only one of the considerations in determining the best approach to archival storage. Active archives generally require faster response to user requests for data than permanent archives. The archive costs have to consider facilities and other capital costs, operations costs, software licenses, utilities costs, etc. For meeting requirements in any organization, typically a mix of technologies is needed.

Magnetic Storage; Technology Evolution↗

NLSI Focus Group on Missing ALSEP Data Recovery: Progress and Plans

On the six Apollo landed missions, the Astronauts deployed the Apollo Lunar Surface Experiments Package (ALSEP) science stations which measured active and passive seismic events, magnetic fields, charged particles, solar wind, heat flow, the diffuse atmosphere, meteorites and their ejecta, lunar dust, etc. Today's scientists are able to extract new information and make new discoveries from the old ALSEP data utilizing recent advances in computer capabilities and new analysis techniques. However, current-day investigators are encountering problems trying to use the ALSEP data. In 2007 archivists from NASA Goddard Space Flight Center (GSFC) National Space Science Data Center (NSSDC) estimated only about 50 percent of the processed ALSEP lunar surface data-of-interest to current lunar science investigators were in the NSSDC archives. The current-day lunar science investigators found most of the ALSEP data, then in the NSSDC archives. were extremely difficult to use. The data were in forms often not well described in the published reports and rerecording anomalies existed in the data which could only be resolved by tape experts. To resolve this problem, the DPS Lunar Data Node was established in 2008 at NSSDC and is in the process of successfully making the existing archived ALSEP data available to current-day investigators in easily useable forms. In July of 2010 the NASA Lunar Science Institute (NLSI) at Ames Research Center established the Recovery of Missing ALSEP Data Focus Group in recognition of the importance of the current activities to find the raw and processed ALSEP data missing from the NSSDC archives.

Lewis, L. R.↗

The global distribution of natural and man-made ionospheric electric fields at 200 kHz and 540 kHz as observed by Ogo 6

An experiment on the polar-orbiting Ogo 6 spacecraft yielded real-time analog data in several broadband channels and essentially continuous tape-recorded data from two narrow-band (200-Hz) receivers operating at 200 and 540 kHz. The results show that the worldwide distributions of signals at 200 and 540 kHz falls into a number of different categories: (1) naturally generated broadband (auroral) hiss at polar latitudes with typical 200-kHz intensities of around 0.1 microvolt per meter per Hz to the 1/2 power, maximum intensities of up to several microvolt per meter per Hz to the 1/2 power, and generally lower intensities at 540 kHz; (2) nighttime midlatitude enhancements of a few microvolts per meter, which probably result either from a superposition of signals from a number of 200- and 540-kHz stations or from interference from intense signals of much higher frequencies; (3) well-defined signal peaks associated with individual ground stations operating at 200 kHz; (4) striking signal enhancements in the conjugate region of a low-latitude 200-kHz station (Ashkhabad), suggesting propagation in the whistler mode to the opposite hemisphere; and (5) occasional signal enhancements at the magnetic equator.

Laaspere, T.↗

Improving the Automatic Inversion of Digital Alouette/ISIS Ionogram Reflection Traces into Topside Electron Density Profiles

The topside sounders of the International Satellites for Ionospheric Studies (ISIS) program were designed as analog systems. The resulting ionograms were displayed on 35 mm film for analysis by visual inspection. Each of these satellites, launched between 1962 and 1971, produced data for 10 to 20 years. A number of the original telemetry tapes from this large data set have been converted directly into digital records. Software, known as the Topside Ionogram Scalar With True-Height (TOPIST) algorithm, has been produced and used for the automatic inversion of the ionogram reflection traces on more than 100,000 ISIS-2 digital topside ionograms into topside vertical electron density profiles Ne(h). Here we present some topside ionospheric solar cycle variations deduced from the TOPIST database to illustrate the scientific benefit of improving and expanding the topside ionospheric Ne(h) database. The profile improvements will be based on improvements in the TOPIST software motivated by direct comparisons between TOPIST profiles and profiles produced by manual scaling in the early days of the ISIS program. The database expansion will be based on new software designed to overcome limitations in the original digital topside ionogram database caused by difficulties encountered during the analog-to-digital conversion process in the detection of the ionogram frame sync pulse and/or the frequency markers. This improved and expanded TOPIST topside Ne(h) database will greatly enhance investigations into both short- and long-term ionospheric changes, e.g., the observed topside ionospheric responses to magnetic storms, induced by interplanetary magnetic clouds, and solar cycle variations, respectively.

Benson, Robert F.↗

Passivation of Flexible YBCO Superconducting Current Lead With Amorphous SiO2 Layer

Adiabatic demagnetization refrigerators (ADR) are operated in space to cool detectors of cosmic radiation to a few 10s of mK. A key element of the ADR is a superconducting magnet operating at about 0.3 K that is continually energized and de-energized in synchronism with a thermal switch, such that a piece of paramagnetic salt is alternately warm in a high magnetic field and cold in zero magnetic field. This causes the salt pill or refrigerant to cool, and it is able to suck heat from an object, e.g., the sensor, to be cooled. Current has to be fed into and out of the magnets from a dissipative power supply at the ambient temperature of the spacecraft. The current leads that link the magnets to the power supply inevitably conduct a significant amount of heat into the colder regions of the supporting cryostat, resulting in the need for larger, heavier, and more powerful supporting refrigerators. The aim of this project was to design and construct high-temperature superconductor (HTS) leads from YBCO (yttrium barium copper oxide) composite conductors to reduce the heat load significantly in the temperature regime below the critical temperature of YBCO. The magnet lead does not have to support current in the event that the YBCO ceases to be superconducting. Cus - tomarily, a normal metal conductor in parallel with the YBCO is a necessary part of the lead structure to allow for this upset condition; however, for this application, the normal metal can be dispensed with. Amorphous silicon dioxide is deposited directly onto the surface of YBCO, which resides on a flexible substrate. The silicon dioxide protects the YBCO from chemically reacting with atmospheric water and carbon dioxide, thus preserving the superconducting properties of the YBCO. The customary protective coating for flexible YBCO conductors is silver or a silver/gold alloy, which conducts heat many orders of magnitude better than SiO2 and so limits the use of such a composite conductor for passing current across a thermal gradient with as little flow of heat as possible to make an efficient current lead. By protecting YBCO on a flexible substrate of low thermal conductivity with SiO2, a thermally efficient and flexible current lead can be fabricated. The technology is also applicable to current leads for 4 K superconducting electronics current biasing. A commercially available thin-film YBCO composite tape conductor is first stripped of its protective silver coating. It is then mounted on a jig that holds the sample flat and acts as a heat sink. Silicon dioxide is then deposited onto the YBCO to a thickness of about 1 micron using PECVD (plasma-enhanced chemical vapor deposition), without heating the YBCO to the point where degradation occurs. Since SiO2 can have good high-frequency electrical properties, it can be used to coat YBCO cable structures used to feed RF signals across temperature gradients. The prime embodiment concerns the conduction of DC current across the cryogenic temperature gradient. The coating is hard and electrically insulating, but flexible.

Johannes, Daniel↗

NASA Tech Briefs, December 2005

Topics covered include: Video Mosaicking for Inspection of Gas Pipelines; Shuttle-Data-Tape XML Translator; Highly Reliable, High-Speed, Unidirectional Serial Data Links; Data-Analysis System for Entry, Descent, and Landing; Hybrid UV Imager Containing Face-Up AlGaN/GaN Photodiodes; Multiple Embedded Processors for Fault-Tolerant Computing; Hybrid Power Management; Magnetometer Based on Optoelectronic Microwave Oscillator; Program Predicts Time Courses of Human/ Computer Interactions; Chimera Grid Tools; Astronomer's Proposal Tool; Conservative Patch Algorithm and Mesh Sequencing for PAB3D; Fitting Nonlinear Curves by Use of Optimization Techniques; Tool for Viewing Faults Under Terrain; Automated Synthesis of Long Communication Delays for Testing; Solving Nonlinear Euler Equations With Arbitrary Accuracy; Self-Organizing-Map Program for Analyzing Multivariate Data; Tool for Sizing Analysis of the Advanced Life Support System; Control Software for a High-Performance Telerobot; Java Radar Analysis Tool; Architecture for Verifiable Software; Tool for Ranking Research Options; Enhanced, Partially Redundant Emergency Notification System; Close-Call Action Log Form; Task Description Language; Improved Small-Particle Powders for Plasma Spraying; Bonding-Compatible Corrosion Inhibitor for Rinsing Metals; Wipes, Coatings, and Patches for Detecting Hydrazines; Rotating Vessels for Growing Protein Crystals; Oscillating-Linear-Drive Vacuum Compressor for CO2; Mechanically Biased, Hinged Pairs of Piezoelectric Benders; Apparatus for Precise Indium-Bump Bonding of Microchips; Radiation Dosimetry via Automated Fluorescence Microscopy; Multistage Magnetic Separator of Cells and Proteins; Elastic-Tether Suits for Artificial Gravity and Exercise; Multichannel Brain-Signal-Amplifying and Digitizing System; Ester-Based Electrolytes for Low-Temperature Li-Ion Cells; Hygrometer for Detecting Water in Partially Enclosed Volumes; Radio-Frequency Plasma Cleaning of a Penning Malmberg Trap; Reduction of Flap Side Edge Noise - the Blowing Flap; and Preventing Accidental Ignition of Upper-Stage Rocket Motors.

Source record↗

Foldable Instrumented Bits for Ultrasonic/Sonic Penetrators

Long tool bits are undergoing development that can be stowed compactly until used as rock- or ground-penetrating probes actuated by ultrasonic/sonic mechanisms. These bits are designed to be folded or rolled into compact form for transport to exploration sites, where they are to be connected to their ultrasonic/ sonic actuation mechanisms and unfolded or unrolled to their full lengths for penetrating ground or rock to relatively large depths. These bits can be designed to acquire rock or soil samples and/or to be equipped with sensors for measuring properties of rock or soil in situ. These bits can also be designed to be withdrawn from the ground, restowed, and transported for reuse at different exploration sites. Apparatuses based on the concept of a probe actuated by an ultrasonic/sonic mechanism have been described in numerous prior NASA Tech Briefs articles, the most recent and relevant being "Ultrasonic/ Sonic Impacting Penetrators" (NPO-41666) NASA Tech Briefs, Vol. 32, No. 4 (April 2008), page 58. All of those apparatuses are variations on the basic theme of the earliest ones, denoted ultrasonic/sonic drill corers (USDCs). To recapitulate: An apparatus of this type includes a lightweight, low-power, piezoelectrically driven actuator in which ultrasonic and sonic vibrations are generated and coupled to a tool bit. The combination of ultrasonic and sonic vibrations gives rise to a hammering action (and a resulting chiseling action at the tip of the tool bit) that is more effective for drilling than is the microhammering action of ultrasonic vibrations alone. The hammering and chiseling actions are so effective that the size of the axial force needed to make the tool bit advance into soil, rock, or another material of interest is much smaller than in ordinary twist drilling, ordinary hammering, or ordinary steady pushing. Examples of properties that could be measured by use of an instrumented tool bit include electrical conductivity, permittivity, magnetic field, magnetic permeability, temperature, and any other properties that can be measured by fiber-optic sensors. The problem of instrumenting a probe of this type is simplified, relative to the problem of attaching electrodes in a rotating drill bit, in two ways: (1) Unlike a rotating drill bit, a bit of this type does not have flutes, which would compound the problem of ensuring contact between sensors and the side wall of a hole; and (2) there is no need for slip rings for electrical contact between sensor electronic circuitry and external circuitry because, unlike a rotating drill, a tool bit of this type is not rotated continuously during operation. One design for a tool bit of the present type is a segmented bit with a segmented, hinged support structure (see figure). The bit and its ultrasonic/sonic actuator are supported by a slider/guiding fixture, and its displacement and preload are controlled by a motor. For deployment from the folded configuration, a spring-loaded mechanism rotates the lower segment about the hinges, causing the lower segment to become axially aligned with the upper segment. A latching mechanism then locks the segments of the bit and the corresponding segments of the slider/guiding fixture. Then the entire resulting assembly is maneuvered into position for drilling into the ground. Another design provides for a bit comprising multiple tubular segments with an inner alignment string, similar to a foldable tent pole comprising multiple tubular segments with an inner elastic cable connecting the two ends. At the beginning of deployment, all segments except the first (lowermost) one remain folded, and the ultrasonic/sonic actuator is clamped to the top of the lowermost segment and used to drive this segment into the ground. When the first segment has penetrated to a specified depth, the second segment is connected to the upper end of the first segment to form a longer rigid tubular bit and the actuator is moved to the upper end of the second segnt. The process as described thus far is repeated, adding segments until the desired depth of penetration has been attained. Yet other designs provide for bits in the form of bistable circular- or rectangular- cross-section tubes that can be stowed compactly like rolls of flat tape and become rigidified upon extension to full length, in a manner partly similar to that of a common steel tape measure. Albeit not marketed for use in tool bits, a bistable reeled composite product that transforms itself from a flat coil to a rigid tube of circular cross section when unrolled, is commercially available under the trade name RolaTube(TradeMark) and serves as a model for the further development of tool bits of this subtype.

Bar-Cohen, Yoseph↗