Search NASA⌕ Search

SEARCH · Search NASA

Results for “MITIGATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Characterizing and Mitigating Intraday Variability: Reconstructing Source Structure in Accreting Black Holes with mm-VLBI

The extraordinary physical resolution afforded by the Event Horizon Telescope has opened a window onto the astrophysical phenomena unfolding on horizon scales in two known black holes, M87* and Sgr A*. However, with this leap in resolution has come a new set of practical complications. Sgr A* exhibits intraday variability that violates the assumptions underlying Earth aperture synthesis, limiting traditional image reconstruction methods to short timescales and data sets with very sparse (u, v) coverage. We present a new set of tools to detect and mitigate this variability. We develop a data-driven, model-agnostic procedure to detect and characterize the spatial structure of intraday variability. This method is calibrated against a large set of mock data sets, producing an empirical estimator of the spatial power spectrum of the brightness fluctuations. We present a novel Bayesian noise modeling algorithm that simultaneously reconstructs an average image and statistical measure of the fluctuations about it using a parameterized form for the excess variance in the complex visibilities not otherwise explained by the statistical errors. These methods are validated using a variety of simulated data, including general relativistic magnetohydrodynamic simulations appropriate for Sgr A* and M87*. We find that the reconstructed source structure and variability are robust to changes in the underlying image model. We apply these methods to the 2017 EHT observations of M87*, finding evidence for variability across the EHT observing campaign. The variability mitigation strategies presented are widely applicable to very long baseline interferometry observations of variable sources generally, for which they provide a data-informed averaging procedure and natural characterization of inter-epoch image consistency.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation of tokamak SOL and divertor region including heat flux mitigation by gas puffing

Two-dimensional (2D), scrape-off layer (SOL)-divertor transport simulations are performed using the integrated plasma-neutral-impurity code KTRAN developed at Seoul National University. Firstly, the code is applied to reproduce a National Spherical Torus eXperiment (NSTX) discharge by using the prescribed transport coefficients and the boundary conditions obtained from the experiment. The plasma density, the heat flux on the divertor plate, and the D (alpha) emission rate profiles from the numerical simulation are found to follow experimental trends qualitatively. Secondly, predictive simulations are carried out for the baseline operation mode in Korea Superconducting Tokamak Advanced Research (KSTAR) to predict the heat flux on the divertor target plates. The stationary peak heat flux in the KSTAR baseline operation mode is expected to be 6.5 MW/m(2) in the case of an orthogonal divertor. To study the mitigation of the heat flux, we investigated the puffing effects of deuterium and argon gases. The puffing position is assumed to be in front of the strike point at the outer lower divertor plate. In the simulations, mitigation of the peak heat flux at the divertor target plates is found to occur when the gas puffing rate exceeds certain values, similar to 1.0 x 10(20) /s and similar to 5.0 x 10(18) /s for deuterium and argon, respectively. Multi-charged impurity transport is also investigated for both NSTX and KSTAR SOL and divertor regions.

Park, Jin Woo↗

Characterization of DESI fiber assignment incompleteness effect on 2-point clustering and mitigation methods for DR1 analysis

We present an in-depth analysis of the fiber assignment incompleteness in the Dark EnergySpectroscopic Instrument (DESI) Data Release 1 (DR1). This incompleteness is caused by therestricted mobility of the robotic fiber positioner in the DESI focal plane, which limits thenumber of galaxies that can be observed at the same time, especially at small angular separations.As a result, the observed clustering amplitude is suppressed in a scale-dependent manner, which,if not addressed, can severely impact the inference of cosmological parameters. We discuss themethods adopted for simulating fiber assignment on mocks and data. In particular, we introducethe fast fiber assignment (FFA) emulator, which was employed to obtain the power spectrumcovariance adopted for the DR1 full-shape analysis. We present the mitigation techniques,organised in two classes: measurement stage and model stage. We then use high fidelity mocks as areference to quantify both the accuracy of the FFA emulator and the effectiveness of the differentmeasurement-stage mitigation techniques. This complements the studies conducted in a parallelpaper for the model-stage techniques, namely the θ-cut approach. We find that pairwiseinverse probability (PIP) weights with angular upweighting recover the “true” clustering in allthe cases considered, in both Fourier and configuration space. Notably, we present the first everpower spectrum measurement with PIP weights from real data.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification and mitigation of memory block timing issue in ITk ABCStar during ASIC production

The ABCStar is a mixed-signal front-end readout ASIC for the strips sensor portion of the ATLAS ITk detector being developed as part of the High-Luminosity LHC upgrade. In pre-production testing, a subtle design flaw was uncovered in the ABCStar that was reducing wafer yields in some manufactured lots from the expected 90% to as low as 2%. The root cause was determined to be a timing issue in the logic synthesized to control previously silicon proven memory blocks re-used for this ASIC. The solutions proposed included manufacturing process changes by the wafer foundry, changes to the operating parameters for the ABCStar in the detector, and the possibility that a redesign might be required. The two mitigation efforts were undertaken in parallel, with the process modification route a less desirable solution since already manufactured wafers would need to be scrapped in favour of the new ones. Based on a knowledge of the existing process, and testing done on the worst performing wafers, it was proposed that raising the core operating voltage of the ABCStar from 1.20V to 1.25V could address the timing issue by sufficiently speeding up its transistors. An extensive testing program that included the effects of temperature and radiation expected over the lifetime of the ITk detector was conducted to validate that approach. Those tests and studies proved that even the worst performing wafers would have yields over 80% with the 1.25V core voltage, and neither the modified process nor redesign would be required for ensuring reliable operation of the ITk. Based on testing, a further timing mitigation was implemented to provide an additional margin of reliability by increasing the duty cycle of the clock to the ABCStar. Testing of all ABCStar wafers has been completed and the production of the detector modules using these ASICs is now well underway as a result of the efforts detailed herein.

FOS: Physical sciences↗

Mitigating PQ Problems in Legacy Data Centers

The conclusions of this presentation are: (1) Problems with PQ in legacy data centers still exist and need to be mitigated; (2) Harmonics generated by non-linear IT load can be lowered by passive, active and hybrid cancellation methods; (3) Harmonic study is necessary to find the best way to treat PQ problems; (4) AHF's and harmonic cancellation transformers proved to be very efficient in mitigating PQ problems; and (5) It is important that IT leaders partner with electrical engineering to appropriate ROI statements, justifying many of these expenditures.

99 GENERAL AND MISCELLANEOUS↗

Disruption Mitigation Technology Concepts and Implications for ITER

Disruptions on ITER present challenges to handle the intense heat flux, the large forces from halo currents, and the potential first wall damage from energetic runaway electrons. Injecting large quantities of material into the plasma during the disruption can reduce the plasma energy and increase its resistivity to mitigate these effects. Assessments of the amount of various mixtures and quantities of material required have been made to provide collision mitigation of runaway electron conversion [1] which is the most difficult challenge. The quantities of material required (~0.5 MPa-m3 for deuterium or helium gas) are large enough to have implications on the design and operation of the vacuum system and tokamak exhaust processing system.

Baylor, Larry R↗

Gas powered fluid gun with recoil mitigation

A gas powered fluid gun for propelling a stream or slug of a fluid at high velocity toward a target. Recoil mitigation is provided that reduces or eliminates the associated recoil forces, with minimal or no backwash. By launching a quantity of water in the opposite direction, net momentum forces are reduced or eliminated. Examples of recoil mitigation devices include a cone for making a conical fluid sheet, a device forming multiple impinging streams of fluid, a cavitating venturi, one or more spinning vanes, or an annular tangential entry/exit.

47 OTHER INSTRUMENTATION↗

Massive Pellet and Rupture Disk Testing for Disruption Mitigation Applications

Injection of massive quantities of noble gases or D2 has proven to be effective at mitigating some of the deleterious effects of disruptions in tokamaks. Two alternative methods that might offer some advantages over the present technique for massive gas injection are shattering massive pellets and employing close-coupled rupture disks. Laboratory testing has been carried out to evaluate their feasibility. For the study of massive pellets, a pipe gun pellet injector cooled with a cryogenic refrigerator was fitted with a relatively large barrel (16.5 mm bore), and D2 and Ne pellets were made and were accelerated to speeds of ~600 and 300 m/s, respectively. Based on the successful proof-of-principle testing with the injector and a special double-impact target to shatter pellets, a similar system has been prepared and installed on DIII-D and should be ready for experiments later this year. To study the applicability of rupture disks for disruption mitigation, a simple test apparatus was assembled in the lab. Commercially available rupture disks of 1 in. nominal diameter were tested at conditions relevant for the application on tokamaks, including tests with Ar and He gases and rupture pressures of ~54 bar. Some technical and practical issues of implementing this technique on a tokamak are discussed.

Combs, Stephen Kirk↗

Gas powered fluid gun with recoil mitigation

A gas powered fluid gun for propelling a stream or slug of a fluid at high velocity toward a target. Recoil mitigation is provided that reduces or eliminates the associated recoil forces, with minimal or no backwash. By launching a quantity of water in the opposite direction, net momentum forces are reduced or eliminated. Examples of recoil mitigation devices include a cone for making a conical fluid sheet, a device forming multiple impinging streams of fluid, a cavitating venturi, one or more spinning vanes, or an annular tangential entry/exit.

42 ENGINEERING↗

Pellet Injection Technology and Application to Mitigate Transient Events on ITER

The technology to form and accelerate cryogenically solidified pellets of hydrogen isotopes has long been under development for fueling fusion plasmas. Injectors are being designed to provide this capability for fueling ITER with DT pellets injected from the inner wall. In addition to this fueling application, the pellet technology is being further developed for ITER to mitigate transient heat fluxes and energetic particle impacts from disruptions and edge localized modes (ELMs). Large shattered impurity pellets have been found to effectively mitigate disruptions and small pellets of deuterium have been used to trigger on demand rapid small ELMs to limit the transient heat flux damage from otherwise large naturally occurring ELMs. Both of these technologies are being implemented for ITER.

Baylor, Larry↗

Flicker Mitigation for a Grid-Connected Tidal and River Power Generator Using the BESS

In the grid-connected tidal and river power generation, the water turbulence and the grid condition can induce the fluctuating output power. This power fluctuation may cause a power quality issue such as flicker, or voltage fluctuations, during the continuous operation. Hence, it is important to assess flicker emission and to mitigate flicker in order to solve this power quality issue. This paper proposes a Battery Energy Storage System (BESS)installed between the power converters of the tidal and river power system in order to mitigate flickers in different grid conditions. The BESS smooths the active power fluctuations and reduces flicker even from the weak grid with the low impedance angle in the distribution network. The feasibility of the proposed BESS system has been tested using a simplified simulation model with interconnected inverters developed in the validated simulation tool of PSCAD/EMTDC, and the obtained results from the case studies are presented.

16 TIDAL AND WAVE POWER↗

Soft error-mitigating semiconductor design system and associated methods

A soft error-mitigating semiconductor design system and associated methods that tailor circuit design steps to mitigate corruption of data in storage elements (e.g., flip flops) due to Single Events Effects (SEEs). Required storage elements are automatically mapped to triplicated redundant nodes controlled by a voting element that enforces majority-voting logic for fault-free output (i.e., Triple Modular Redundancy (TMR)). Storage elements are also optimally positioned for placement in keeping with SEE-tolerant spacing constraints. Additionally, clock delay insertion (employing either a single global clock or clock triplication) in the TMR specification may introduce useful skew that protects against glitch propagation through the designed device. The resultant layout generated from the TMR configuration may relax constraints imposed on register transfer level (RTL) engineers to make rad-hard designs, as automation introduces TMR storage registers, memory element spacing, and clock delay/triplication with minimal designer input.

Miryala, Sandeep↗

Fuel hardware considerations for BWR PCI mitigation

Pellet-clad interaction (PCI) remains a potential cause of fuel failures and is a major consideration in the design of new BWR fuel assemblies. The design and material properties of both the pellet and the cladding have been investigated and optimized to mitigate the impact of PCI. The creep behavior of standard and ADOPT (Advanced Doped Pellet Technology) fuel pellets has been measured across a wide range of temperatures. Dopants have been found to increase the high temperature creep properties of the fuel and can explain the improved PCI resistance of ∼5 kW/m in ramp tests. Other effects, such as chemical trapping of fission products and modified crack patterns cannot be ruled out, but these are at an earlier stage of investigation. It is shown that the enhanced creep effect occurs at the high centerline fuel temperatures during a ramp test, but is not present during the much lower temperatures of commercial fuel operation. Thus low temperature PCI benefits in routine commercial operation are not expected. The development of cladding materials with liner provided a great improvement for PCI mitigation in BWRs. With the softer Westinghouse liner, stepwise ramp tests have shown a benefit of ca 15-20 kW/m. Differences between stepwise and single step ramp tests are discussed. Notably the benefit of the liner remains under all types of fuel operation and temperatures. It is also thought to provide significant benefit in the case of fuel relocation or pellet defects such as missing pellet chips. The results of post irradiation examination (PIE) of a commercial fuel rod that experienced fuel fragment relocation are presented in the paper. To provide the maximum PCI benefit in the next generation BWR fuel design, TRITON11, the proven benefits of both the liner and ADOPT pellets will be included. To reduce the hydrogen pickup, below that of Zircaloy-2, the outer cladding component will be made from HiFi. TRITON11, ADOPT and HiFi are registered trademarks of Westinghouse Electric Company LLC in the United States. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Vapor Intrusion Mitigation Beneath an Occupied Industrial Building at the Young - Rainey Science, Technology, and Research Center Largo, Florida - 17463

Groundwater contamination, consisting of chlorinated solvents, was identified in the southeastern portion of the Pinellas Site in Largo, Florida. The contamination is beneath Building 100, an 11-acre building that housed manufacturing facilities during US Department of Energy (DOE) operations at the site. Because the building was constructed in phases over a period of decades, it is comprised of approximately 20 different buildings, each with a separate foundation, all of which are now connected under a single roof. Based on the results of a pilot test that indicated the presence of volatile organic compounds beneath the floor slab and, in the absence of state regulations or guidance, DOE elected to proactively address the potential for release of these compounds into the facility by designing and installing a vapor intrusion (VI) mitigation system. To ventilate vapors from beneath the building, piping was installed from beneath the concrete floor slab through the roof, and negative pressure was created using electric blowers. The system design was complicated by foundation walls supporting each of the various sections of Building 100 and by special requirements due to the sensitive nature of the tenant's manufacturing activities and the heightened need for security. This paper addresses significant aspects of the design and construction of a VI mitigation system beneath a large, occupied industrial production facility, including technical, logistical, and environmental challenges; community relations; and regulatory relations. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

'Top 10' Facility Decommissioning Risks and Mitigation Strategies to Prevent Them - 16487

Decommissioning represents a set of risks that differ from facility design and construction, operations, or maintenance. An informal poll was taken querying experienced facility decommissioning project and program managers in government and private business sectors about top decommissioning risks. The poll considered experience in nuclear, fossil fuel, and oil and gas projects in Canada, the United States, the United Kingdom, and Australia. A classic risk assessment process was performed, where the likelihood and consequence(s) of impacts, typical or most commonly used controls, and the most effective mitigation strategies for various risks were identified. The risks that polled with the highest rankings were identified as the 'Top 10' decommissioning risks. Roger VanScoy stated 'Knowing our risks provides opportunities to manage and improve our chances of success.' The purpose of this effort was to identify and share the 'Top 10' decommissioning risks with those in the nuclear, fossil fuel, and oil and gas industry to help anticipate and manage those risks more effectively, avoid or reduce the potential consequences of the risks, and improve the chances of project success. Douglas Adams said: 'Human beings, who are almost unique in having the ability to learn from the experience of others, are also remarkable for their apparent disinclination to do so'. The information provided shares experiences, knowledge, and effective mitigation strategies from those with successful decommissioning experience so that others can learn and avoid the adverse consequences of risks inherent with decommissioning projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of ELAP and mitigation strategies in Maanshan PWR with PCTRAN

On March 11, 2011, the Fukushima Daiichi Nuclear Power Plant, owned by Tokyo Electric Power Company, encountered a beyond design basis earthquake/tsunami and the flood crippled the on-site emergency power and electric transmission systems. The ELAP (Extended Loss of Alternating Current Power) and LUHS (Loss of Ultimate Heat Sink) events severely damaged the core cooling systems and the safety functions of the containment. As a result, three reactor cores were damaged. Also, the cooling capability of nuclear spent fuel pools was lost due to loss of AC and DC power. Existing Station Blackout (SBO) analyses have demonstrated that even with leakage from Reactor Coolant Pump (RCP) seals, the core could maintain coolable only when heat transfer exists between primary loop and secondary loop. Depend on the availability of DC power in different plant designs, the SBO coping times were shown to be 4 to 16 hours. According to INPO event report, it is necessary to analyze the consequences if current coping times are extended with increased core water inventory loss from pump seals. In an ELAP scenario, all active system including Emergency Core Cooling System (ECCS) and motor driven AFW were out of power supply, results in degradation of core cooling capability. Moreover, the fuel exposed risk would increase due to continuously Reactor Coolant System (RCS) inventory loss through pump seals. Therefore, mitigation strategy must be applied prior to core uncovering to prevent its damage and assure plant safety. This research utilized a fast running NPP safety simulation code, PCTRAN, to assess reactor performances in the situations of ELAP of Maanshan PWR. Also, the sensitivity study of injection flow rates and effectiveness of mitigation strategy were demonstrated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems: Preprint

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the Pennsylvania-New Jersey-Maryland Interconnection (PJM), in a competitive electricity market. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure and vulnerable communication networks to a multitude of cybersecurity threats. These evolving threats not only endanger grid operations but also have the potential to trigger cascading disruptions across the broader grid network and influence regulation markets. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events and provide a comprehensive situation awareness to grid operators. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a fully active BESS topology using the slow regulation signal (Reg A) coming from the PJM market. Our simulation results reveal that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's instability and economic loss during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Mitigation Methods for Piperazine Oxidation in Post-Combustion Carbon Capture

Piperazine is a promising second-generation solvent for amine scrubbing in post-combustion CO2 capture. However, the oxidative degradation of PZ can cause environmental problems and economic loss. This work presents the effects of two mitigation methods: carbon treating and N2 sparging, on the PZ oxidation in long-term operations. The species and their respective quantities adsorbed by the activated carbon were tested in a bench-scale device. The carbon was then tested in the High Temperature Oxidation Reactor (HTOR), where the solvent oxidizes at a reasonably fast rate. Pilot plant campaigns were also performed at the UT Austin SRP and the National Carbon Capture Center (NCCC) and the effects were verified. When dissolved Fe is removed by carbon treating or other methods, available soluble Fe in the system dissolves and replaces the dissolved Fe. Therefore, all available Fe and ligands need to be removed for the mitigation to be effective. The sources of soluble Fe include fly ash and the corrosion of stainless steel, and the ligands are degradation products. 8 All PZ degraded solvents have two absorbance peaks at 320 nm and 538 nm. The 320 nm peak is caused by dissolved metals, especially Fe, complexed by degradation products. The 320 nm peak is related to the amine degradation level and can be used as a simple and efficient method to estimate the amine degradation rate. The pilot plant data suggest that NO2 can oxidize PZ significantly, possibly through radical reactions. 0.01 mmol/kg-hr absorption of NO2 increased the PZ oxidation rate from 1.2 mmol/kg-hr to 2.5 mmol/kg-hr.

Yuying, Wu↗