Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Bystander Effects During Synchrotron Imaging Procedures?

Using monochromatic beam and synchrotron phase-contrast technique at the biomedical beamline of the Italian synchrotron facility Elettra (SYRMEP), we have shown in a small animal model of malignant brain tumor that it is possible to obtain high-resolution images of very small tumors when they have developed from implanted tumor cells loaded with colloidal gold nanoparticles (GNP). All previous experiments were conducted in post-mortem samples. We have now designed a cell culture experiment to investigate the effects of synchrotron radiation with an energy and dose profile similar to that expected in our first in vivo imaging studies according to the protocol developed at SYRMEP.Materials and Methods: Culture flasks containing either gold-loaded or naieve C6 glioma cells were exposed to a dose of 0.5 Gy at 24 keV. The irradiated medium was aspirated and replaced with fresh growth medium. Twenty-four hours later this non-irradiated medium exposed to irradiated cells was aspirated, then added to non-irradiated C6 cells in order to investigate whether bystander effects are seen under the conditions of our image acquisition protocol. The irradiated medium was added to a number of other non-irradiated cell cultures. Cell counts were followed until 72 hrs after irradiation. Western blots were conducted with H2AX antibodies. This experiment was one of the first biomedical experiments conducted at BMIT, the new biomedical imaging and therapy beamline of the Canadian Light Source.Results: No significant differences in proliferation were seen between cells that were directly irradiated, exposed to irradiated medium or exposed to the non-irradiated 24-hr-medium from the irradiated cells. However, there was a tendency towards a higher number of double strand breaks in previously irradiated cells when they were exposed to non-irradiated medium that had been in contact with irradiated cells for 24 hrs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laboratory reflectometer for the investigation of optical elements in a wavelength range of 5–50 nm: description and testing results

We describe a laboratory reflectometer developed at the IPM RAS for precision measurements of spectral and angular dependences of the reflection and transmission coefficients of optical elements in a wavelength range of 5–50 nm. The radiation is monochromatised using a high-resolution Czerny–Turner spectrometer with a plane diffraction grating and two spherical collimating mirrors. A toroidal mirror focuses the probe monochromatic beam on a sample. The X-ray source is a highly ionised plasma produced in the interaction of a high-power laser beam with a solid target at an intensity of 10{sup 11}–10{sup 12} W cm{sup –2}. To stabilise the emission characteristics, the target executes translatory and rotary motions in such a way that every pulse irradiates a new spot. The short-focus lens is protected from contamination by erosion products with the use of a specially designed electromagnetic system. The samples under study are mounted on a goniometer is accommodated in a dedicated chamber, which provides five degrees of freedom for samples up to 500 mm in diameter and two degrees of freedom for a detector. The sample mass may range up to 10 kg. The X-ray radiation is recorded with a detector composed of a CsI photocathode and two microchannel plates. A similar detector monitors the probe beam intensity. The spectral reflectometer resolution is equal to 0.030 nm with the use of ruled gratings with a density of 900 lines mm{sup –1} (spectral range: 5–20 nm) and to 0.067 nm for holographic gratings with a density of 400 lines mm{sup –1} (spectral range: 10–50 nm). We analyse the contribution of higher diffraction orders to the probe signal intensity and the ways of taking it into account in the measurements. Examples are given which serve to illustrate the reflectometer application to the study of multilayer mirrors and filters. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compton Scattering in Ignited Thermonuclear Plasmas

Inertially confined, ignited thermonuclear D-T plasmas will produce intense blackbody radiation at temperatures T > or approx. 20 keV; it is shown that the injection of GeV electrons into the burning core can efficiently generate high-energy Compton scattering photons. Moreover, the spectrum scattered in a small solid angle can be remarkably monochromatic, due to kinematic pileup; a peak brightness in excess of 10{sup 30} photons/(mm{sup 2} mrad{sup 2} s 0.1% bandwidth) is predicted. These results are discussed within the context of the Schwinger field and the Sunyaev-Zel'dovich effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SPITZER ANALYSIS OF H II REGION COMPLEXES IN THE MAGELLANIC CLOUDS: DETERMINING A SUITABLE MONOCHROMATIC OBSCURED STAR FORMATION INDICATOR

H II regions are the birth places of stars, and as such they provide the best measure of current star formation rates (SFRs) in galaxies. The close proximity of the Magellanic Clouds allows us to probe the nature of these star forming regions at small spatial scales. To study the H II regions, we compute the bolometric infrared flux, or total infrared (TIR), by integrating the flux from 8 to 500 {mu}m. The TIR provides a measure of the obscured star formation because the UV photons from hot young stars are absorbed by dust and re-emitted across the mid-to-far-infrared (IR) spectrum. We aim to determine the monochromatic IR band that most accurately traces the TIR and produces an accurate obscured SFR over large spatial scales. We present the spatial analysis, via aperture/annulus photometry, of 16 Large Magellanic Cloud (LMC) and 16 Small Magellanic Cloud (SMC) H II region complexes using the Spitzer Space Telescope's IRAC (3.6, 4.5, 8 {mu}m) and MIPS (24, 70, 160 {mu}m) bands. Ultraviolet rocket data (1500 and 1900 A) and SHASSA H{alpha} data are also included. All data are convolved to the MIPS 160 {mu}m resolution (40 arcsec full width at half-maximum), and apertures have a minimum radius of 35''. The IRAC, MIPS, UV, and H{alpha} spatial analysis are compared with the spatial analysis of the TIR. We find that nearly all of the LMC and SMC H II region spectral energy distributions (SEDs) peak around 70 {mu}m at all radii, from {approx}10 to {approx}400 pc from the central ionizing sources. As a result, we find the following: the sizes of H II regions as probed by 70 {mu}m are approximately equal to the sizes as probed by TIR ({approx}70 pc in radius); the radial profile of the 70 {mu}m flux, normalized by TIR, is constant at all radii (70 {mu}m {approx} 0.45TIR); the 1{sigma} standard deviation of the 70 {mu}m fluxes, normalized by TIR, is a lower fraction of the mean (0.05-0.12 out to {approx}220 pc) than the normalized 8, 24, and 160 {mu}m normalized fluxes (0.12-0.52); and these results are the same for the LMC and the SMC. From these results, we argue that 70 {mu}m is the most suitable IR band to use as a monochromatic obscured star formation indicator because it most accurately reproduces the TIR of H II regions in the LMC and SMC and over large spatial scales. We also explore the general trends of the 8, 24, 70, and 160 {mu}m bands in the LMC and SMC H II region SEDs, radial surface brightness profiles, sizes, and normalized (by TIR) radial flux profiles. We derive an obscured SFR equation that is modified from the literature to use 70 {mu}m luminosity, SFR(M {sub sun} yr{sup -1}) = 9.7(0.7) x 10{sup -44} L {sub 70}(ergs s{sup -1}), which is applicable from 10 to 300 pc distance from the center of an H II region. We include an analysis of the spatial variations around H II regions between the obscured star formation indicators given by the IR and the unobscured star formation indicators given by UV and H{alpha}. We compute obscured and unobscured SFRs using equations from the literature and examine the spatial variations of the SFRs around H II regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Near monochromatic 20 Me V proton acceleration using fs laser irradiating Au foils in target normal sheath acceleration regime

A 200 mJ laser pulse energy, 39 fs-pulse duration, 10 μm focal spot, p-polarized radiation has been employed to irradiate thin Au foils to produce proton acceleration in the forward direction. Gold foils were employed to produce high density relativistic electrons emission in the forward direction to generate a high electric field driving the ion acceleration. Measurements were performed by changing the focal position in respect of the target surface. Proton acceleration was monitored using fast SiC detectors in time-of-flight configuration. A high proton energy, up to about 20 Me V, with a narrow energy distribution, was obtained in particular conditions depending on the laser parameters, the irradiation conditions, and a target optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Note: Synchrotron-based high-energy x-ray phase sensitive microtomography for biomedical research

Purpose: Propagation-based phase-contrast CT (PPCT) utilizes highly sensitive phase-contrast technology applied to x-ray microtomography. Performing phase retrieval on the acquired angular projections can enhance image contrast and enable quantitative imaging. In this work, the authors demonstrate the validity and advantages of a novel technique for high-resolution PPCT by using the generalized phase-attenuation duality (PAD) method of phase retrieval. Methods: A high-resolution angular projection data set of a fish head specimen was acquired with a monochromatic 60-keV x-ray beam. In one approach, the projection data were directly used for tomographic reconstruction. In two other approaches, the projection data were preprocessed by phase retrieval based on either the linearized PAD method or the generalized PAD method. The reconstructed images from all three approaches were then compared in terms of tissue contrast-to-noise ratio and spatial resolution. Results: The authors’ experimental results demonstrated the validity of the PPCT technique based on the generalized PAD-based method. In addition, the results show that the authors’ technique is superior to the direct PPCT technique as well as the linearized PAD-based PPCT technique in terms of their relative capabilities for tissue discrimination and characterization. Conclusions: This novel PPCT technique demonstrates great potential for biomedical imaging, especially for applications that require high spatial resolution and limited radiation exposure.

60 APPLIED LIFE SCIENCES↗

THE X-RAY ENERGY DEPENDENCE OF THE RELATION BETWEEN OPTICAL AND X-RAY EMISSION IN QUASARS

We develop a new approach to the well-studied anti-correlation between the optical-to-X-ray spectral index, alpha{sub ox}, and the monochromatic optical luminosity, l{sub opt}. By cross-correlating the Sloan Digital Sky Survey DR5 quasar catalog with the XMM-Newton archive, we create a sample of 327 quasars with X-ray signal-to-noise ratio (S/N) > 6, where both optical and X-ray spectra are available. This allows alpha{sub ox} to be defined at arbitrary frequencies, rather than the standard 2500 A and 2 keV. We find that while the choice of optical wavelength does not strongly influence the alpha{sub ox}-l{sub opt} relation, the slope of the relation does depend on the choice of X-ray energy. The slope of the relation becomes steeper when alpha{sub ox} is defined at low (approx1 keV) X-ray energies. This change is significant when compared to the slope predicted by a decrease in the baseline over which alpha{sub ox} is defined. The slopes are also marginally flatter than predicted at high (approx10 keV) X-ray energies. Partial correlation tests show that while the primary driver of alpha{sub ox} is l{sub opt}, the Eddington ratio correlates strongly with alpha{sub ox} when l{sub opt} is taken into account, so accretion rate may help explain these results. We combine the alpha{sub ox}-l{sub opt} and GAMMA-L{sub bol}/L{sub Edd} relations to naturally explain two results: (1) the existence of the GAMMA-l{sub x} relation as reported in Young et al., and (2) the lack of a GAMMA-l{sub opt} relation. The consistency of the optical/X-ray correlations establishes a more complete framework for understanding the relation between quasar emission mechanisms. We also discuss two correlations with the hard X-ray bolometric correction, which we show correlates with both alpha{sub ox} and Eddington ratio. This confirms that an increase in accretion rate correlates with a decrease in the fraction of up-scattered disk photons.

79 ASTRONOMY AND ASTROPHYSICS↗

Parameterization of IR cooling in a middle atmosphere dynamics model. I - Effects on the zonally averaged circulation

A computationally efficient two-stream parameterization of IR cooling is developed for a middle atmosphere dynamics model. The parameterization combines the monochromatic feature of an emissivity formulation with the computational simplicity of a single spatial integral to evaluate the monochromatic transfer equation. Calculations show strong radiative control of the mesopause region and the need for substantial deceleration of the mean zonal winds. Calculated temperatures show good agreement in the summer hemisphere where planetary wave activity is negligible, but in the polar night of the winter hemisphere they are about 30 K too cold, which suggests planetary wave heating must make up the deficit. With observed ozone densities, globally averaged radiative equilibrium temperatures in the 65-75 km region are too cold and an additional heat source about 1 K/day is required.

Apruzese, J. P.↗

High-pressure structural behavior and equation of state of NaZnF{sub 3}

We report the results of density functional theory ab-initio calculations and monochromatic synchrotron X-ray diffraction study carried out for orthorhombic NaZnF{sub 3} in the pressure range 0-40 GPa. Perovskite-to-postperovskite phase transition was anticipated by first-principles computations and then observed in high-pressure diamond anvil cell synchrotron diffraction experiment between 14 and 22 GPa. Above 25 GPa postperovskite structure (CaIrO{sub 3} type, space group Cmcm) coexists with another phase, yet unidentified. On decompression, pure postperovskite-type structure was found to be stable down to 4 GPa; below this pressure sample contained both perovskite and postperovskite modifications. Fit of experimental P-V data to the third-order Birch-Murnaghan equation of state gave bulk moduli, K{sub P,0} 64.98+-2.67 and 69.88+-3.69 GPa for perovskite and postperovskite modifications, respectively. Both phases demonstrated strong anisotropy of compressibility. For postperovskite NaZnF{sub 3}, the highest compression was observed along the direction perpendicular to the planes of ZnF{sub 6} octahedra arrangement. - Graphical Abstract: Fit of P-V data obtained from high-pressure X-ray diffraction study of perovskite and postperovskite NaZnF{sub 3} to the third-order Birch-Murnaghan equation of state (solid line). Open and closed symbols represent experimental data corresponding to compression and decompression, respectively. Bulk moduli, K{sub 0,P}, of perovskite and postperovskite phases are 64.98+-2.67 and 69.88+-3.69 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Radio Spectral Energy Distribution and Star-formation Rate Calibration in Galaxies

We study the spectral energy distribution (SED) of the radio continuum (RC) emission from the Key Insight in Nearby Galaxies Emitting in Radio (KINGFISHER) sample of nearby galaxies to understand the energetics and origin of this emission. Effelsberg multi-wavelength observations at 1.4, 4.8, 8.4, and 10.5 GHz combined with archive data allow us, for the first time, to determine the mid-RC (1–10 GHz, MRC) bolometric luminosities and further present calibration relations versus the monochromatic radio luminosities. The 1–10 GHz radio SED is fitted using a Bayesian Markov Chain Monte Carlo technique leading to measurements for the nonthermal spectral index (S{sub ν}∼ν{sup −α{sub n}{sub t}}) and the thermal fraction (f{sub th}) with mean values of α{sub nt}=0.97 ± 0.16(0.79 ± 0.15 for the total spectral index) and f{sub th} = (10 ± 9)% at 1.4 GHz. The MRC luminosity changes over ∼3 orders of magnitude in the sample, 4.3× 10{sup 2} L{sub ⊙} < MRC < 3.9× 10{sup 5} L{sub ⊙}. The thermal emission is responsible for ∼23% of the MRC on average. We also compare the extinction-corrected diagnostics of the star-formation rate (SFR) with the thermal and nonthermal radio tracers and derive the first star-formation calibration relations using the MRC radio luminosity. The nonthermal spectral index flattens with increasing SFR surface density, indicating the effect of the star-formation feedback on the cosmic-ray electron population in galaxies. Comparing the radio and IR SEDs, we find that the FIR-to-MRC ratio could decrease with SFR, due to the amplification of the magnetic fields in star-forming regions. This particularly implies a decrease in the ratio at high redshifts, where mostly luminous/star-forming galaxies are detected.

79 ASTRONOMY AND ASTROPHYSICS↗

Polarization of photons scattered by electrons in any spectral distribution

On the basis of the quantum electrodynamics, we present a generic formalism of the polarization for beamed monochromatic photons scattered by electrons in any spectral distribution. The formulae reduce to the components of the Fano matrix when electrons are at rest. We mainly investigate the polarization in three scenarios, i.e., electrons at rest, isotropic electrons with a power-law spectrum, and thermal electrons. If the incident beam is polarized, the polarization is reduced significantly by isotropic electrons at large viewing angles; the degree of polarization caused by thermal electrons is about half of that caused by power-law electrons. If the incident bean is unpolarized, soft γ-rays can lead to about 15% polarization at viewing angles around π/4. For isotropic electrons, one remarkable feature is that the polarization as a function of the incident photon energy always peaks roughly at 1 MeV; this is valid for both the thermal and power-law cases. This feature can be used to distinguish the model of the inverse Compton scattering from that of the synchrotron radiation.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of non-monochromaticity in laboratory XPS: Representative example of pyrimidine

The Mg and Al K α radiation used in standard laboratory sources for X-Ray Photoelectron Spectroscopy, XPS, is not naturally monochromatic because the spin orbit splitting of the Mg and Al 2p shells is not normally resolved. However, since the 2p spin-orbit splitting of the K α1 and K α2 X-Rays in these light atoms is small, it is normally ignored. In the present work, the consequences of the departure from monochromaticity is explicitly shown to be extremely small for the representative case of the C(1 s) ionizations in the XPS of the pyrimidine molecule. Furthermore, this conclusion is general and does not depend on the particular molecule studied since the K α1 and K α2 BE splittings reflect the spin-orbit splittings in the X-Ray source.

Binding Energies (BEs)↗

FABRY-PEROT VERSUS SLIT SPECTROPOLARIMETRY OF PORES AND ACTIVE NETWORK: ANALYSIS OF IBIS AND HINODE DATA

We discuss spectropolarimetric measurements of photospheric (Fe I 630.25 nm) and chromospheric (Ca II 854.21 nm) spectral lines in and around small magnetic flux concentrations, including a pore. Our long-term goal is to diagnose properties of the magnetic field near the base of the corona. We compare ground-based two-dimensional spectropolarimetric measurem ents with (almost) simultaneous space-based slit spectropolarimetry. We address the question of noise and crosstalk in the measurements and attempt to determine the suitability of Ca II measurements with imaging spectropolarimeters for the determination of chromospheric magnetic fields. The ground-based observations were obtained 2008 May 20, with the Interferometric Bidimensional Spectrometer (IBIS) in spectropolarimetric mode operated at the Dunn Solar Telescope at Sunspot, NM. The space observations were obtained with the Spectro-Polarimeter of the Solar Optical Telescope aboard the Japanese Hinode satellite. The agreement between the near-simultaneous co-spatial IBIS and Hinode Stokes-V profiles at 630.25 nm is excellent, with V/I amplitudes compatible to within 1%. The IBIS QU measurements are affected by residual crosstalk from V, arising from calibration inaccuracies, not from any inherent limitation of imaging spectroscopy. We use a Principal Component Analysis to quantify the detected crosstalk. QU profiles with V crosstalk subtracted are in good agreement with the Hinode measurements, but are noisier owing to fewer collected photons. Chromospheric magnetic fields are notoriously difficult to constrain by polarization of Ca II lines alone. However, we demonstrate that high cadence, high angular resolution monochromatic images of fibrils in Ca II and Halpha, seen clearly in IBIS observations, can be used to improve the magnetic field constraints, under conditions of high electrical conductivity. Such work is possible only with time series data sets from two-dimensional spectroscopic instruments such as IBIS, under conditions of good seeing.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-FG-207B-10: Dual-Energy CT Monochromatic Image Consistency Across Vendors and Platforms

Purpose: Although dual-energy CT provides improved sensitivity of HU for certain tissue types at lower simulated energy levels, if these values vary by scanner type they may impact clinical patient management decisions. Each manufacturer has selected a specific dual-energy CT approach (or in one case, three different approaches); understanding HU variability among low monochromatic images may be required when more than one dual-energy CT scanner type is available for use. Methods: A large elliptical dualenergy quality control phantom (Gammex Inc.; Middleton, WI) containing several standard tissue type materials was scanned at least three times on each of the following systems: GE HD750, prototype GE Revolution CT with GSI, Siemens Flash, Siemens Edge, Siemens AS 128, and Philips IQon. Images were generated at 50, 70, and 140 keV. Soft tissue and Iodine HU were measured on a single central 5mm-thick image; NIST constants were used to calculate the ideal HU for each material. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were held as consistent as possible (thickness, kernel, no noise reduction). Results: Measured soft tissue (29 HU at 120 kVp) varied from 28 HU to 44 HU at 50 keV (excluding one outlier), from 21 HU to 31 HU at 70 keV, and from 19 HU to 32 HU at 140 keV. Measured iodine (5mg/ml, 106 HU at 120 kVp) varied from 246 HU to 280 HU at 50 keV, from 123 HU to 129 HU at 70 keV, and from 22 HU to 32 HU at 140 keV. Conclusion: Measured HU in standard rods across 3 dual-energy CT manufacturers and 6 scanner models varied directly with monochromatic level, with the most variability was observed at 50 keV and least variability at 70keV. Future work will include additional scanner platforms and how measurement variability impacts radiologists. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

TU-EF-204-12: Quantitative Evaluation of Spectral Detector CT Using Virtual Monochromatic Images: Initial Results

Purpose To evaluate the image quality and spectral information of a spectral detector CT (SDCT) scanner using virtual monochromatic (VM) energy images. Methods The SDCT scanner (Philips Healthcare) was equipped with a dual-layer detector and spectral iterative reconstruction (IR), which generates conventional 80–140 kV polychromatic energy (PE) CT images using both detector layers, PE images from the low-energy (upper) and high-energy (lower) detector layers and VM images. A solid water phantom with iodine (2.0–20.0 mg I/ml) and calcium (50.0–600.0 mg Ca/ml) rod inserts was used to evaluate effective energy estimate (EEE) and iodine contrast to noise ratio (CNR). The EEE corresponding to an insert CT number in a PE image was calculated from a CT number fit to the VM image set. Since PE image is prone to beam-hardening artifact EEE may underestimate the actual energy separation from two layers of the detector. A 30-cm-diameter water phantom was used to evaluate noise power spectrum (NPS). The phantoms were scanned at 120 and 140 kV with the same CTDIvol. Results The CT number difference for contrast inserts in VM images (50–150 keV) was 1.3±6% between 120 and 140 kV scans. The difference of EEE calculated from low- and high-energy detector images was 11.5 and 16.7 keV for 120 and 140 kV scans, respectively. The differences calculated from 140 and 100 kV conventional PE images were 12.8, and 20.1 keV from 140 and 80 kV conventional PE images. The iodine CNR increased monotonically with decreased keV. Compared to conventional PE images, the peak of NPS curves from VM images were shifted to lower frequency. Conclusion The EEE results indicates that SDCT at 120 and 140 kV may have energy separation comparable to 100/140 kV and 80/140 kV dual-kV imaging. The effects of IR on CNR and NPS require further investigation for SDCT. Author YY and AD are Philips Healthcare employees.

60 APPLIED LIFE SCIENCES↗

Technical Note: Removing the stem effect when performing Ir-192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: A relevant and necessary step

Purpose: The purpose of this study was to investigate whether or not a stem effect removal technique is necessary when performing Ir-192 HDR brachytherapy in vivo dosimetry using a scintillation detector. Methods: A red-green-blue photodiode connected to a multichannel electrometer was used to detect the light emitted from a plastic scintillation detector (PSD) during irradiation with an Ir-192 HDR brachytherapy source. Accuracy in dose measurement was compared with and without the use of stem effect removal techniques. Monochromatic and polychromatic filtration techniques were studied. An in-house template was built for accurate positioning of catheters in which the source and the PSD were inserted. Dose distribution was measured up to 5 cm from source to detector in the radial and longitudinal directions. Results: The authors found the stem effect to be particularly important when the source was close to the optical fiber guide and far from the scintillation component of the detector. It can account for up to (72{+-}3)% of the signal under clinically relevant conditions. The polychromatic filtration outperformed the monochromatic filtration as well as the absence of filtration in regard to dose measurement accuracy. Conclusions: It is necessary to implement a stem effect removal technique when building a PSD for in vivo dosimetry during Ir-192 HDR brachytherapy. The PSD that the authors have developed for this study would be suitable for such an application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-contrast imaging with a novel X-ray source

A novel X-ray source based on Parametric X-ray radiation (PXR) has been employed for phase-contrast imaging at the Laboratory for Electron Beam Research and Application (LEBRA), Nihon University, Japan. The PXR X-rays were generated by the 100 MeV electron beam passing through a Si single crystal. The X-rays in the 16approx34 keV range were chosen for imaging of biological samples. The quasi-monochromatic, tunable, and coherent X-ray source is appropriate for this application. In addition, the large X-ray beam irradiation field of approximately 100 mm in diameter, which was achieved without special optics, suggests that the PXR is applicable to imaging for medical diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

Oscillation of neutrinos produced by the annihilation of dark matter inside the Sun

The annihilation of dark matter particles captured by the Sun can lead to a neutrino flux observable in neutrino detectors. Considering the fact that these dark matter particles are nonrelativistic, if a pair of dark matter annihilates to a neutrino pair, the spectrum of neutrinos will be monochromatic. We show that in this case, even after averaging over the production point inside the Sun, the oscillatory terms of the oscillation probability do not average to zero. This leads to interesting observable features in the annual variation of the number of muon track events. We show that smearing of the spectrum due to thermal distribution of dark matter inside the Sun is too small to wash out this variation. We point out the possibility of studying the initial flavor composition of neutrinos produced by the annihilation of dark matter particles via measuring the annual variation of the number of {mu}-track events in neutrino telescopes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗