Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Enhancement of a Process Flowsheet for Recovering and Concentrating Critical Materials from Bituminous Coal Sources

Recovery of rare earth elements (REE) from coal-related resources has recently received significant interest due to supply concerns and their key roles in critical industries and defense-related technologies. In this study, an integrated flowsheet consisting of sorting, crushing/grinding, physical separation, acid leaching, solvent extraction, and selective precipitation was designed to achieve continuous production of rare earth products from various coal-related resources such as coarse refuse and acid mine drainage. A pilot plant was constructed that enabled continuous testing of the circuitry on a range of different coal-based feedstocks. Despite achieving significant success in producing high-grade rare earth oxide products, low REE recovery values and high operational costs necessitated a re-evaluation of the process flowsheet. This article describes the circuitry improvements that were based on both laboratory and pilot plant test results. Roasting as a pre-leach treatment was found to significantly improve the leaching rate and overall REE recovery values. After roasting West Kentucky No. 13 and Fire Clay coal refuse materials at 600 °C, REE recovery increased by 60 and 40 absolute percentage points, respectively. Rare earth concentration in the pregnant leachate solution (PLS) was increased to around 700 ppm prior to solvent extraction using a staged precipitation method. REEs in the precipitate were re-dissolved, purified, and extracted from the PLS using solvent extraction and selective precipitation to values of around 80%. As a result of the improvements, chemical consumption in the acid leaching and solvent extraction processes was significantly reduced. A techno-economical assessment of the improved flowsheet indicated significant commercialization potential.

01 COAL, LIGNITE, AND PEAT↗

Grade Inflation in Medical Student Radiation Oncology Clerkships: Missed Opportunities for Feedback?

Purpose: To test the hypothesis that medical student radiation oncology elective rotation grades are inflated and cannot be used to distinguish residency applicants. Methods and Materials: The records of 196 applicants to a single radiation oncology residency program in 2011 and 2012 were retrospectively reviewed. The grades for each rotation in radiation oncology were collected and converted to a standardized 4-point grading scale (honors, high pass, pass, fail). Pass/fail grades were scored as not applicable. The primary study endpoint was to compare the distribution of applicants' grades in radiation oncology with their grades in medicine, surgery, pediatrics, and obstetrics/gynecology core clerkships. Results: The mean United States Medical Licensing Examination Step 1 score of the applicants was 237 (range, 188-269), 43% had additional Masters or PhD degrees, and 74% had at least 1 publication. Twenty-nine applicants were graded for radiation oncology rotations on a pass/fail basis and were excluded from the final analysis. Of the remaining applicants (n=167), 80% received the highest possible grade for their radiation oncology rotations. Grades in radiation oncology were significantly higher than each of the other 4 clerkships studied (P<.001). Of all applicants, 195 of 196 matched into a radiation oncology residency. Higher grades in radiation oncology were associated with significantly higher grades in the pediatrics core clerkship (P=.002). However, other medical school performance metrics were not significantly associated with higher grades in radiation oncology. Conclusions: Although our study group consists of a selected group of radiation oncology applicants, their grades in radiation oncology clerkships were highly skewed toward the highest grades when compared with grades in other core clerkships. Student grading in radiation oncology clerkships should be re-evaluated to incorporate more objective and detailed performance metrics to allow for meaningful feedback to trainees and to better evaluate residency applicants to radiation oncology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reporting Quality of Randomized, Controlled Trials Evaluating Combined Chemoradiotherapy in Nasopharyngeal Carcinoma

Purpose: To comprehensively assess the reporting quality of randomized, controlled trials (RCTs) in nasopharyngeal carcinoma (NPC), and to identify significant predictors of quality. Methods and Materials: Two investigators searched MEDLINE and EMBASE for RCTs published between January 1988 and December 2015 that assessed the effect of combined chemoradiotherapy for NPC. The overall quality of each report was assessed using a 28-point overall quality score (OQS) based on the 2010 Consolidated Standards of Reporting Trials (CONSORT) statement. To provide baseline data for further evaluation, we also investigated the reporting quality of certain important issues in detail, including key methodologic items (allocation concealment, blinding, intention-to-treat principle), endpoints, follow-up, subgroup analyses, and adverse events. Results: We retrieved 24 relevant RCTs including 6591 patients. Median 2010 OQS was 15.5 (range, 10-24). Half of the items in the 2010 OQS were poorly reported in at least 40% of trials. Multivariable regression models revealed that publication after 2010 and high impact factor were significant predictors of improved 2010 OQS. Additionally, many issues that we consider significant were not reported adequately. Conclusions: Despite publication of the CONSORT statement more than a decade ago, overall reporting quality for RCTs in NPC was unsatisfactory. Additionally, substantial selectivity and heterogeneity exists in reporting of certain crucial issues. This survey provides the first prompt for NPC trial investigators to improve reporting quality according to the CONSORT statement; increased scrutiny and diligence by editors and peer reviewers is also required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructure of titanium on complex deformation paths: Comparison of ECAP, KOBO and HE techniques

Highlights: • Method for producing CP titanium rods for medical implants is searched. • Three processing methods producing ultra-fine grain titanium are compared. • Microstructure and textures are examined and analysed. • Mechanical characteristics are determined based on microhardness and tensile tests. • Hydrostatic extrusion (HE) leads to the best properties of titanium rods for medical implants. - Abstract: In this work samples of commercial purity grade 2 titanium were severely deformed by three different extrusion techniques: equal-channel angular pressing (ECAP), extrusion through oscillating die (KOBO), and hydrostatic extrusion (HE). Resulting microstructures and mechanical properties of processed titanium samples are studied and compared with regard to potential application as a material for dental implants. The obtained results demonstrate the effect of different strain paths, involved by three applied deformation methods, on microstructure refinement, mechanical properties and textures of the studied material. Heterogeneous microstructures with bimodal grain size distributions are observed for all deformation techniques in the examined material, however differences in their internal structures and grain boundary distributions point to different grain refinement mechanisms. The fraction of ultra-fine grains is the highest in titanium deformed by HE. Also the internal grain fragmentation is the most important after HE deformation. This leads to the best mechanical and microstructural properties obtained in this type of deformation. Consequently, the HE process seems to be very interesting for production of material for medical implants.

36 MATERIALS SCIENCE↗

Roadmap for a sustainable circular economy in lithium-ion and future battery technologies

Abstract The market dynamics, and their impact on a future circular economy for lithium-ion batteries (LIB), are presented in this roadmap, with safety as an integral consideration throughout the life cycle. At the point of end-of-life (EOL), there is a range of potential options—remanufacturing, reuse and recycling. Diagnostics play a significant role in evaluating the state-of-health and condition of batteries, and improvements to diagnostic techniques are evaluated. At present, manual disassembly dominates EOL disposal, however, given the volumes of future batteries that are to be anticipated, automated approaches to the dismantling of EOL battery packs will be key. The first stage in recycling after the removal of the cells is the initial cell-breaking or opening step. Approaches to this are reviewed, contrasting shredding and cell disassembly as two alternative approaches. Design for recycling is one approach that could assist in easier disassembly of cells, and new approaches to cell design that could enable the circular economy of LIBs are reviewed. After disassembly, subsequent separation of the black mass is performed before further concentration of components. There are a plethora of alternative approaches for recovering materials; this roadmap sets out the future directions for a range of approaches including pyrometallurgy, hydrometallurgy, short-loop, direct, and the biological recovery of LIB materials. Furthermore, anode, lithium, electrolyte, binder and plastics recovery are considered in order to maximise the proportion of materials recovered, minimise waste and point the way towards zero-waste recycling. The life-cycle implications of a circular economy are discussed considering the overall system of LIB recycling, and also directly investigating the different recycling methods. The legal and regulatory perspectives are also considered. Finally, with a view to the future, approaches for next-generation battery chemistries and recycling are evaluated, identifying gaps for research. This review takes the form of a series of short reviews, with each section written independently by a diverse international authorship of experts on the topic. Collectively, these reviews form a comprehensive picture of the current state of the art in LIB recycling, and how these technologies are expected to develop in the future.

25 ENERGY STORAGE↗

MCNP6 Study of Spatial Fidelity Required for ROC Curve Convergence

The detection of special nuclear material at ports and borders is one of the primary missions of the Department of Homeland Security's (DHS) Domestic Nuclear Detection Office (DNDO). In support of this mission a large-scale modeling and simulation effort has been undertaken with the goal of providing a comprehensive tool-kit that addresses the complexity of problems involved with developing and maintaining technologies deployed to global nuclear detection architecture (GNDA) nodes. An important objective of DNDO's mission is to characterize detector system performance before deployment. In the effort to support this mission, the latest version of MCNP has been used to perform detectability studies of highly enriched uranium (HEU) to populate a database that will be used for the tool-kit. The characterization method used in the implementation of the database is the receiver operating characteristic (ROC). A ROC curve shows the limits of detectability of a given system as well as an overall metric of the efficacy of a detection system. This is accomplished by comparing total detector count distributions to the count distribution produced by background alone. For an in-depth explanation of the theory behind the MCNP production of ROC curves please refer to the paper, 'How To Use The Receiver Operating Characteristic Tally Option in MCNP6'. Building a useful database requires an expansive parameter space. The current tool-kit use nine parameters, which if varied with just 5 options each, results in nearly two million simulations to run. Depending on the set of parameters these simulations can take a few hours or a few weeks to complete. This computational cost necessitates the use of scaling algorithms to interpolate between the data contained in the database. The tool-kit employs a discrete event method to simulate the movement and detector response of special nuclear material (SNM) through a GNDA node. Given the nature of a discrete event simulation, constant motion of SNM must be split up in to discrete spatial detection points. The fidelity required of the spatial splitting to achieve a properly converged answer is investigated here for a neutron detection system. The detector used was a SNAP-3 neutron detector in front of a sphere of SNM in the presence of background radiation. A parameter study has been performed to determine the spatial fidelity required for ROC curve convergence for moving objects in a discrete event simulator. It appears that 5 points is the minimum number of detection points with 7 points needed for one of the parameter sets. The convergence worsens with increases to detection length but appears to improve with increasing detector distance. These results will help future work involving quantifying the accuracy based on given tolerances and parameters. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reliable and explainable machine-learning methods for accelerated material discovery

Abstract Despite ML’s impressive performance in commercial applications, several unique challenges exist when applying ML in materials science applications. In such a context, the contributions of this work are twofold. First, we identify common pitfalls of existing ML techniques when learning from underrepresented/imbalanced material data. Specifically, we show that with imbalanced data, standard methods for assessing quality of ML models break down and lead to misleading conclusions. Furthermore, we find that the model’s own confidence score cannot be trusted and model introspection methods (using simpler models) do not help as they result in loss of predictive performance (reliability-explainability trade-off). Second, to overcome these challenges, we propose a general-purpose explainable and reliable machine-learning framework. Specifically, we propose a generic pipeline that employs an ensemble of simpler models to reliably predict material properties. We also propose a transfer learning technique and show that the performance loss due to models’ simplicity can be overcome by exploiting correlations among different material properties. A new evaluation metric and a trust score to better quantify the confidence in the predictions are also proposed. To improve the interpretability, we add a rationale generator component to our framework which provides both model-level and decision-level explanations. Finally, we demonstrate the versatility of our technique on two applications: (1) predicting properties of crystalline compounds and (2) identifying potentially stable solar cell materials. We also point to some outstanding issues yet to be resolved for a successful application of ML in material science.

97 MATHEMATICS AND COMPUTING↗

Synthesis and Characterization of Superconductor Diodes

In the era of modern computing, quantum bits (or qubits) are extensively researched due to their ability to perform computations exponentially faster than classical computers. One promising method for synthesizing qubits on a macroscopic scale is through superconductor diodes (SDs). Unfortunately, SDs are currently limited by their dependence on extremely low temperatures (T ≈ 0K), which restricts their practical usability at larger scales. To address this limitation, researchers are exploring new materials and methods to identify superconductors with higher critical temperatures. My research at the Lawrence Livermore National Laboratory (LLNL) focuses on synthesizing and characterizing superconductor diodes to determine their efficiency for quantum computing applications. Bismuth thin films were synthesized with magnetron sputtering with separate thicknesses which provides information on methods to alter their resistivity. Bismuth was characterized as the topological insulator used in the diode, and its resistivity was measured using a standard four-point probe technique with 1 mA current. Bismuth (99.99% pure) was then purified in a tubular furnace at 400C to use within a Josephson junction as a topological insulator. Niobium and Tantalum Josephson junctions were then synthesized, and they were characterized using a lock-in amplifier four-point probe technique. Materials such as niobium and tantalum are used in high-entropy alloy research, which is a relatively new class of material that has little research within the superconductor diode community, yet the current research shows promise. We anticipate that testing high-entropy superconductors will reveal crucial factors, potentially leading to the development of high-temperature superconductors in the future.

36 MATERIALS SCIENCE↗

Study of preparation of TiB{sub 2} by TiC in Al melts

TiB{sub 2} particles are prepared by TiC in Al melts and the characteristics of them are studied. It is found that TiC particles are unstable when boron exists in Al melts with high temperature and will transform to TiB{sub 2} and Al{sub 4}C{sub 3}. Most of the synthesized TiB{sub 2} particles are regular hexagonal prisms with submicron size. The diameter of the undersurfaces of these prisms is ranging from 200 nm to 1 {mu}m and the height is ranging from 100 nm to 300 nm. It is considered that controlling the transformation from TiC to TiB{sub 2} is an effective method to prepare small and uniform TiB{sub 2} particles. - Highlights: Black-Right-Pointing-Pointer TiC can easily transform into TiB{sub 2} in Al melts. Black-Right-Pointing-Pointer TiB{sub 2} formed by TiC will grow into regular hexagonal prisms with submicron size. Black-Right-Pointing-Pointer Controlling the transformation from TiC to TiB{sub 2} is an effective method to prepare small and uniform TiB{sub 2} particles.

36 MATERIALS SCIENCE↗

Diagnosing heterogeneous dynamics in single-molecule/particle trajectories with multiscale wavelets

In this study, we describe a simple automated method to extract and quantify transient heterogeneous dynamical changes from large data sets generated in single-molecule/particle tracking experiments. Based on wavelet transform, the method transforms raw data to locally match dynamics of interest. This is accomplished using statistically adaptive universal thresholding, whose advantage is to avoid a single arbitrary threshold that might conceal individual variability across populations. How to implement this multiscale method is described, focusing on local confined diffusion separated by transient transport periods or hopping events, with three specific examples: in cell biology, biotechnology, and glassy colloid dynamics. The discussion is generalized within the framework of continuous time random walk. This computationally efficient method can run routinely on hundreds of millions of data points analyzed within an hour on a desktop personal computer.

36 MATERIALS SCIENCE↗

Carbons with Regular Pore Geometry Yield Fundamental Insights into Supercapacitor Charge Storage

We conduct molecular dynamics simulations of electrical double-layer capacitors (EDLCs) using a library of ordered, porous carbon electrode materials called zeolite templated carbons (ZTCs). The well-defined pore shapes of the ZTCs enable us to determine the influence of pore geometry on both charging dynamics and charge storage mechanisms in EDLCs, also referred to as supercapacitors. We show that charging dynamics are negatively correlated with the pore-limiting diameter of the electrode material and display signatures of both progressive charging and ion trapping. However, the equilibrium capacitance, unlike charging dynamics, is not strongly correlated to commonly used, purely geometric descriptors such as pore size. Instead, we find a strong correlation of capacitance to the charge compensation per carbon (CCpC), a descriptor we define in this work as the average charge of the electrode atoms within the coordination shell of a counterion. A high CCpC indicates efficient charge storage, as the strong partial charges of the electrode are able to screen counterion charge, enabling higher ion loading and thus more charge storage within the electrode at a fixed applied voltage. We determine that adsorption sites with a high CCpC tend to be found within pockets with a smaller radius of curvature, where the counterions are able to minimize their distance with multiple points on the electrode surface, and therefore induce stronger local partial charges.

25 ENERGY STORAGE↗

Criticality detection method based on FP gamma radiation measurement

A method is proposed to evaluate the extent of subcriticality of an accident-damaged nuclear reactor. In this method the radiation ratio of two FP rare gas nuclides, {sup 88}Kr and {sup 133}Xe, is measured. From the measured value, the value in the core is estimated by correcting for the time required by the gases to diffuse from the core to the measuring point. A simple expression for neutron multiplication factor has been derived, which uses the corrected {sup 88}Kr-to-{sup 133}Xe radiation ratio and the {sup 88}Kr-to-{sup 133}Xe fission yield ratios from {sup 244}Cm and {sup 235}U but no information on the amount or distribution of fissile materials, making the proposed method very simple. The method has the advantage that FP rare gases can easily leak from the reactor core through many openings and gaps, reaching germanium counters without reacting with other materials. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Understanding the Cu-Zn brass alloys using a short-range-order cluster model: Significance of specific compositions of industrial alloys

Metallic alloys show complex chemistries that are not yet understood so far. It has been widely accepted that behind the composition selection lies a short-range-order mechanism for solid solutions. The present paper addresses this fundamental question by examining the face-centered-cubic Cu-Zn a-brasses. A new structural approach, the cluster-plus-glue-atom model, is introduced, which suits specifically for the description of short-range-order structures in disordered systems. Two types of formulas are pointed out, [Zn-Cu 12 ]Zn 1,6 and [Zn-Cu 12 ](Zn,Cu) 6 , which explain the a-brasses listed in the American Society for Testing and Materials (ASTM) specifications. In these formulas, the bracketed parts represent the 1 st -neighbor cluster, and each cluster is matched with one to six 2 nd -neighbor Zn atoms or with six mixed (Zn,Cu) atoms. Such a cluster-based formulism describes the 1 st - and 2 nd -neighbor local atomic units where the solute and solvent interactions are ideally satisfied. The Cu-Ni industrial alloys are also explained, thus proving the universality of the cluster-formula approach in understanding the alloy selections. The revelation of the composition formulas for the Cu-(Zn,Ni) industrial alloys points to the common existence of simple composition rules behind seemingly complex chemistries of industrial alloys, therefore offering a fundamental and practical method towards composition interpretations of all kinds of alloys.

36 MATERIALS SCIENCE↗

Kramers nodal lines and Weyl fermions in SmAlSi

Kramers nodal lines (KNLs) have recently been proposed theoretically as a special type of Weyl line degeneracy connecting time-reversal invariant momenta. KNLs are robust to spin orbit coupling and are inherent to all non-centrosymmetric achiral crystal structures, leading to unusual spin, magneto-electric, and optical properties. However, their existence in in real quantum materials has not been experimentally established. Here we gather the experimental evidence pointing at the presence of KNLs in SmAlSi, a non-centrosymmetric metal that develops incommensurate spin density wave order at low temperature. Using angle-resolved photoemission spectroscopy, density functional theory calculations, and magneto-transport methods, we provide evidence suggesting the presence of KNLs, together with observing Weyl fermions under the broken inversion symmetry in the paramagnetic phase of SmAlSi. We discuss the nesting possibilities regarding the emergent magnetic orders in SmAlSi. Our results provide a solid basis of experimental observations for exploring correlated topology in SmAlSi.

36 MATERIALS SCIENCE↗

Clinical Experience and Evaluation of Patient Treatment Verification With a Transit Dosimeter

Purpose: To prospectively evaluate a protocol for transit dosimetry on a patient population undergoing intensity modulated radiation therapy (IMRT) and to assess the issues in clinical implementation of electronic portal imaging devices (EPIDs) for treatment verification. Methods and Materials: Fifty-eight patients were enrolled in the study. Amorphous silicon EPIDs were calibrated for dose and used to acquire images of delivered fields. Measured EPID dose maps were back-projected using the planning computed tomographic (CT) images to calculate dose at prespecified points within the patient and compared with treatment planning system dose offline using point dose difference and point γ analysis. The deviation of the results was used to inform future action levels. Results: Two hundred twenty-five transit images were analyzed, composed of breast, prostate, and head and neck IMRT fields. Patient measurements demonstrated the potential of the dose verification protocol to model dose well under complex conditions: 83.8% of all delivered beams achieved the initial set tolerance level of Δ{sub D} of 0 ± 5 cGy or %Δ{sub D} of 0% ± 5%. Importantly, the protocol was also sensitive to anatomic changes and spotted that 3 patients from 20 measured prostate patients had undergone anatomic change in comparison with the planning CT. Patient data suggested an EPID-reconstructed versus treatment planning system dose difference action level of 0% ± 7% for breast fields. Asymmetric action levels were more appropriate for inversed IMRT fields, using absolute dose difference (−2 ± 5 cGy) or summed field percentage dose difference (−6% ± 7%). Conclusions: The in vivo dose verification method was easy to use and simple to implement, and it could detect patient anatomic changes that impacted dose delivery. The system required no extra dose to the patient or treatment time delay and so could be used throughout the course of treatment to identify and limit systematic and random errors in dose delivery for patient groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The damage Mechanics challenge Results: Participant predictions compared with experiment

In this article, We present results from a recent exercise where participating organizations were asked to provide model-based blind predictions of damage evolution in 3D-printed geomaterial analogue test articles. Participants were provided with a range of data characterizing both the undamaged state (e.g., ultrasonic measurements) and damage evolution (e.g., 3-point bending, unconfined compression, and Brazilian testing) of the material. In this paper, we focus on comparisons between the participants’ predictions and the previously secret challenge problem experimental observations. We present valuable lessons learned for the application of numerical methods to deformation and failure in brittle-ductile materials. The exercise also enables us to identify which specific types of calibration data were of most utility to the participants in developing their predictions. Further, we identify additional data that would have been useful for participants to improve the confidence of their predictions. Consequently, this work improves our understanding of how to better characterize a material to enable more accurate prediction of damage and failure propagation in natural and engineered brittle-ductile materials.

36 MATERIALS SCIENCE↗

Factors for Predicting Rectal Dose of High-Dose-Rate Intracavitary Brachytherapy After Pelvic Irradiation in Patients With Cervical Cancer: A Retrospective Study With Radiography-Based Dosimetry

Purpose: To evaluate the predictive factors for rectal dose of the first fraction of high-dose-rate intracavitary brachytherapy (HDR-ICBT) in patients with cervical cancer. Methods and Materials: From March 1993 through February 2008, 946 patients undergoing pelvic irradiation and HDR-ICBT were analyzed. Examination under anesthesia (EUA) at the first implantation of the applicator was usually performed in the early period. Rectal point was determined radiographically according to the 38th Report of the International Commission of Radiation Units and Measurements (ICRU). The ICRU rectal dose (PRD) as a percentage of point A dose was calculated; multiple linear regression models were used to predict PRD. Results: Factors influencing successful rectal dose calculation were EUA (p < 0.001) and absence of diabetes (p = 0.047). Age (p < 0.001), body weight (p = 0.002), diabetes (p = 0.020), and EUA (p < 0.001) were independent factors for the PRD. The predictive equation derived from the regression model was PRD (%) = 57.002 + 0.443 x age (years) - 0.257 x body weight (kg) + 6.028 x diabetes (no: 0; yes: 1) - 8.325 x EUA (no: 0; yes: 1) Conclusion: Rectal dose at the first fraction of HDR-ICBT is positively influenced by age and diabetes, and negatively correlated with EUA and body weight. A small fraction size at point A may be considered in patients with a potentially high rectal dose to reduce the biologically effective dose if the ICRU rectal dose has not been immediately obtained in the first fraction of HDR-ICBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-term Outcomes and Quality of Life of 186 Patients With Primary Parotid Carcinoma Treated With Surgery and Radiotherapy at the Daniel den Hoed Cancer Center

Purpose: To assess the outcomes, toxicity, and quality of life (QOL) of patients with primary parotid carcinoma treated with surgery and postoperative radiotherapy at the Daniel den Hoed Cancer Center. Methods and Materials: Between 1995 and 2010, 186 patients with parotid carcinoma were treated with parotidectomy with or without neck dissection, followed by radiotherapy. Elective nodal irradiation (ENI) was applied to high-risk, node-negative disease. End points were locoregional control (LRC), disease-free survival (DFS), cause-specific survival (CSS), and overall survival (OS), late toxicity, and QOL. Results: After a median follow-up of 58 months (range, 4-172 months), the 5-year Kaplan-Meier estimates for LRC, DFS, CSS, and OS were 89%, 83%, 80%, and 68%, respectively. Forty-five events were reported: 24 distant metastases (DM) and 21 locoregional failures (LRF). Event-free survival rates by histological types were 89%, 78%, 76%, 74%, and 70% for acinic cell, mucoepidermoid, adenoid cystic, adenocarcinoma, and squamous cell carcinoma, respectively. More LRF were reported in patients with squamous cell and high-grade mucoepidermoid carcinoma (21% and 19%, respectively) than in patients with other histological types (p = 0.04) and more DM in patients with adenoid cystic and adenocarcinoma (20% and 19%, respectively) than in patients with other types (p = 0.03). None of the high-risk node-negative patients who received ENI developed regional failure. On multivariate analysis, T stage, N stage, grade, and presence of perineural invasion and facial paralysis correlated significantly with DFS. The 5-year cumulative incidence of grade {>=}2 late toxicity was 8%. QOL scores deteriorate during and shortly after treatment but returned in almost all scales to baseline scores within 6 months. Conclusions: Of the entire group, surgery and postoperative radiotherapy resulted in excellent outcomes with minimal side effects and preservation of good QOL scores. However, in view of the pattern of failures observed in this study, the role of adjuvant systemic or targeted therapy in patients at high risk of DM should be investigated in prospective trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗