Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Impact of calibration technique on measurement accuracy for the JET core charge-exchange system

The core charge-exchange diagnostic at the Joint European Torus (JET) provides measurements of the impurity ion temperature Ti, toroidal velocity V , and impurity ion densities nimp, across the whole minor radius. A contribution to the uncertainty of the measured quantities is the error resulting from the multi-Gaussian fit and photon statistics, usually quoted for each measured data. Absolute intensity calibration and especially alignment of the viewing directions can introduce an important systematic error. The technique adopted at JET to reduce this systematic contribution to the error is presented in this paper. The error in Ti, V , and nimp is then discussed depending on their use.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analog Techniques for Measuring the Frequency Response of Linear Physical Systems Excited by Frequency-Sweep Inputs

Data-reduction methods using general-purpose analog computer equipment and compatible testing techniques for determining the frequency response of linear physical systems are examined. The techniques considered may be classed as steady state or transient depending on the method of excitation. The relative merits of periodic, slow sweep, and transient (rapid sweep) forcing functions are discussed and applications are given that relate to dynamic-response tests of aeroelastic systems. Two frequency-sweep-input methods are considered in detail. one case the sweep rate is sufficiently slow that the response is approximately the same as that for steady-state conditions. With this input the frequency response can be evaluated and displayed in real time while the test is in progress. Errors due to treating sweep data as steady state can be eliminated, when desired, by reanalyzing tape-recorded time histories of the input and output as transient rather than as periodic data. In the second method the frequency-response function is deter- mined from the system's transient response to a very rapid sweep input. The purpose of frequency sweep in this case is to provide sufficient harmonic content in the input to overcome noise while keeping the test time as short as possible. tests and limited flight-test data presented herein, it appears that a transient-type rapid-sweep forcing function offers a considerable saving in test time while preserving the accuracy possible with steady-state sinusoidal inputs.

Wilmer H. Reed III↗

Steam Generators: Thermal Hydraulic Measurements and Instrumentation

Steam generators are integral components of both conventional and advanced reactors utilizing steam power cycles, as they influence the power conversion performance. Steam generator designs are highly influenced by the type of reactor coolant used, which mainly governs the different control, monitoring, and safety system actuation requirements. Therefore, the present work reviews the thermal hydraulics instrumentation within steam generators designed for pressurized water reactors (PWRs), high-temperature gas-cooled reactors (HTGRs), sodium fast reactors (SFRs), and molten salt cooled reactors (MSRs). Emphasis is given to measurement techniques that are either unique or particularly important to specific reactor types. Lastly, a discussion is provided on the instrumentation and measured parameters. The work identifies standard parameters of interest and is expected to aid the development of test beds and novel measurements techniques.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Spatially Resolved Temperature and Water Vapor Concentration Distributions in Supersonic Combustion Facilities by TDLAT

Detailed knowledge of the internal structure of high-enthalpy flows can provide valuable insight to the performance of scramjet combustors. Tunable Diode Laser Absorption Spectroscopy (TDLAS) is often employed to measure temperature and species concentration. However, TDLAS is a path-integrated line-of-sight (LOS) measurement, and thus does not produce spatially resolved distributions. Tunable Diode Laser Absorption Tomography (TDLAT) is a non-intrusive measurement technique for determining two-dimensional spatially resolved distributions of temperature and species concentration in high enthalpy flows. TDLAT combines TDLAS with tomographic image reconstruction. More than 2500 separate line-of-sight TDLAS measurements are analyzed in order to produce highly resolved temperature and species concentration distributions. Measurements have been collected at the University of Virginia's Supersonic Combustion Facility (UVaSCF) as well as at the NASA Langley Direct-Connect Supersonic Combustion Test Facility (DCSCTF). Due to the UVaSCF s unique electrical heating and ability for vitiate addition, measurements collected at the UVaSCF are presented as a calibration of the technique. Measurements collected at the DCSCTF required significant modifications to system hardware and software designs due to its larger measurement area and shorter test duration. Tomographic temperature and water vapor concentration distributions are presented from experimentation on the UVaSCF operating at a high temperature non-reacting case for water vitiation level of 12%. Initial LOS measurements from the NASA Langley DCSCTF operating at an equivalence ratio of 0.5 are also presented. Results show the capability of TDLAT to adapt to several experimental setups and test parameters.

Busa, K. M.↗

A proposed configuration for a stepped specimen to be used in the systematic evaluation of factors influencing warpage in metallic alloys being used for cryogenic wind tunnel models

A proposed configuration for a stepped specimen to be used in the system evaluation of mechanisms that can introduce warpage or dimensional changes in metallic alloys used for cryogenic wind tunnel models is described. Considerations for selecting a standard specimen are presented along with results obtained from an investigation carried out for VASCOMAX 200 maraging steel. Details of the machining and measurement techniques utilized in the investigation are presented. Initial results from the sample of VASCOMAX 200 show that the configuration and measuring techniques are capable of giving quantitative results.

Wigley, D. A.↗

A survey of particle image velocimetry applications in Langley aerospace facilities

This paper describes several applications of the global velocity measurement technique known as particle image velocimetry to three different facilities at Langley Research Center. These three applications represent global velocity measurements in distinctly different flows, namely a reacting hydrogen - air flame, a low Reynolds number boundary layer, and hypersonic flow over a wedge. In addition, these applications illustrate the power of the instrument to obtain data such as vorticity and Reynolds stress. Finally, the ability to obtain particle dynamics data in supersonic/hypersonic flows similar to that which can be obtained with point measurement techniques is demonstrated.

Humphreys, W. M.↗

Doppler global velocimetry - The next generation?

A new measurement technique is being developed by NASA to measure off-surface flow fields. This method, Doppler global velocimetry, will allow quantification of complex three-dimensional flow fields at video camera rates. The entire flow field structure within a selected plane is measured simultaneously rather than by scanned, point-by-point measurements using conventional laser velocimetry. To assess the capability of this new technique, velocity measurements of the vortical flow field above a thin 75-degree delta wing were made in the NASA Langley Basic Aerodynamics Research Tunnel. The operation of the system is described along with the techniques developed to process the output images. The results are then compared with similar measurements obtained using a three component laser velocimeter.

Meyers, James F.↗

Doppler Global Velocimetry: The Next Generation?

A new measurement technique is being developed by NASA to measure off-surface flow fields. This method, Doppler global velocimetry, will allow quantification of complex three-dimensional flow fields at video camera rates. The entire flow field structure within a selected plane is measured simultaneously rather than by scanned, point-by-point measurements using conventional laser velocimetry. To assess the capability of this new technique, velocity measurements of the vortical flow field above a thin 75-degree delta wing were made in the NASA Langley Basic Aerodynamics Research Tunnel. The operation of the system is described along with the techniques developed to process the output images. The results are then compared with similar measurements obtained using a three component laser velocimeter.

Meyers, James F.↗

A novel technique for measurement of thermal rate constants and temperature dependences of dissociative recombination: CO{sub 2}{sup +}, CF{sub 3}{sup +}, N{sub 2}O{sup +}, C{sub 7}H{sub 8}{sup +}, C{sub 7}H{sub 7}{sup +}, C{sub 6}H{sub 6}{sup +}, C{sub 6}H{sub 5}{sup +}, C{sub 5}H{sub 6}{sup +}, C{sub 4}H{sub 4}{sup +}, and C{sub 3}H{sub 3}{sup +}

A novel technique using a flowing afterglow-Langmuir probe apparatus for measurement of temperature dependences of rate constants for dissociative recombination (DR) is presented. Low ({approx}10{sup 11} cm{sup -3}) concentrations of a neutral precursor are added to a noble gas/electron afterglow plasma thermalized at 300-500 K. Charge exchange yields one or many cation species, each of which may undergo DR. Relative ion concentrations are monitored at a fixed reaction time while the initial plasma density is varied between 10{sup 9} and 10{sup 10} cm{sup -3}. Modeling of the decrease in concentration of each cation relative to the non-recombining noble gas cation yields the rate constant for DR. The technique is applied to several species (O{sub 2}{sup +}, CO{sub 2}{sup +}, CF{sub 3}{sup +}, N{sub 2}O{sup +}) with previously determined 300 K values, showing excellent agreement. The measurements of those species are extended to 500 K, with good agreement to literature values where they exist. Measurements are also made for a range of C{sub n}H{sub m}{sup +} (C{sub 7}H{sub 7}{sup +}, C{sub 7}H{sub 8}{sup +}, C{sub 5}H{sub 6}{sup +}, C{sub 4}H{sub 4}{sup +}, C{sub 6}H{sub 5}{sup +}, C{sub 3}H{sub 3}{sup +}, and C{sub 6}H{sub 6}{sup +}) derived from benzene and toluene neutral precursors. C{sub n}H{sub m}{sup +} DR rate constants vary from 8-12 Multiplication-Sign 10{sup -7} cm{sup 3} s{sup -1} at 300 K with temperature dependences of approximately T{sup -0.7}. Where prior measurements exist these results are in agreement, with the exception of C{sub 3}H{sub 3}{sup +} where the present results disagree with a previously reported flat temperature dependence.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two techniques for measuring locomotion impact forces during zero G

A load-cell-instrumented treadmill mated to a Kistler force plate was used to investigate two methods of force measurement instrumentation during treadmill ambulation in zero g, created by parabolic flight on NASA's KC-135 aircraft. Current spaceflight treadmills do not have adequate instrumentation to determine the resultant foot impact force applied during restrained ambulation. Accurate measurement of foot-ground reaction forces is critical in attaining proper one-g loading, therefore ensuring proper musculoskeletal conditioning. Treadmill instrumentation and force plate measurements were compared for frequency response and linearity. Locomotion impact data were also collected under one-g laboratory settings and in Keplerian flight. The first resonant frequency for both techniques was found to be well above the primary frequency content of the locomotive forces. Peak impact forces measured by the two systems compared to within 10 percent.

Greenisen, Michael C.↗

The delta Doppler technique for LDV measurements at long distances

A technique for measuring velocity, referred to as a Delta Doppler technique, was presented. This technique determines scattering source velocities by measuring the difference in Doppler shifts of two different frequencies. By transmitting the two frequencies along the same path, a moving fringe pattern is established such that a nonmoving scatterer at the sensing volume would see an intensity variation exactly equal to the difference in the transmitted frequencies. If the particle has a velocity component along an axis which bisects the angle formed by the transmitter and receiver axes, a Doppler shift in the difference frequency can be measured and the velocity component computed. The frequency measured would correspond to the difference in Doppler frequencies that two laser Doppler velocimeters using separate frequencies (the same frequencies as used previously) would have measured, thus the term Delta Doppler.

Cliff, W. C.↗

Beyond the Streetlight Effect: A United Future for Relaxation and Diffraction Methods for Residual Stress Measurement

Residual stress measurement techniques can be categorized as either relaxation or diffraction methods. Practitioners often advocate a particular category and sometimes a specific technique (hole drilling, contour, XRD, neutron, etc) based on their experience or capability rather than using the best technique for the particular application. This paper considers some of the implications from applying this “drunkard’s search” or “streetlight” approach by examining examples where the critical stress could be hidden from both relaxation and diffraction measurements. A better approach to planning residual stress measurements would begin with a detailed consideration of why the stresses should be measured and how the results will be used. Only then can the most appropriate measurement plan be developed. Since a single measurement technique cannot reveal the full state of stress, especially in challenging parts, the use of multiple measurement types often provides the most useful information to customers.

36 MATERIALS SCIENCE↗

Single-shot complete spatiotemporal measurement of terawatt laser pulses

In this work, we demonstrate, for the first time, a single-shot, complete spatiotemporal measurement of pulses from a terawatt-scale, multi-stage-amplified, low repetition-rate laser source. The ultrashort pulse electric field, E(x,y,z,t), is spatiotemporally complex due to distortions that accrue from multiple chirped-pulse amplifiers, which requires a complete characterization. Meanwhile, the instability of the laser source introduces field profiles that vary significantly from pulse to pulse, which, together with the low repetition-rate (15 shots/hour), requires the use of a single-shot measurement technique. To accomplish the measurements, we used a wavelength-multiplexed, digital-holographic technique called Spatially and Temporally Resolved Intensity and Phase Evaluation Device: Full Information from a Single Hologram, specially tailored to measure picosecond pulses at a wavelength of about 1 μm. Specifically, individual pulses from the compact multipulse terawatt laser were measured, with up to 0.3 J per shot of energy and ~2 ps pulse durations, at 1052 nm. With these measurements, we characterized several major spatiotemporal distortions that affect the peak intensity at the laser focus, as well as the pulse-shape instability on a shot-to-shot basis. Our technique allows detailed diagnosis of laser pulses (especially high-order spatiotemporal distortions) and provides straightforward four-dimensional animations of pulse propagation to a focus.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic technique for measuring adsorption in a gas chromatograph

Gas-chromatographic procedure, together with mathematical analysis of adsorption isotherm, allows relative surface areas and adsorptive powers for trace concentrations to be determined in a few minutes. Technique may be used to evaluate relative surface areas of different adsorbates, expressed as volume of adsorbent/gram of adsorbate, and to evaluate their relative adsorptive power.

Deuel, C. L.↗

Time-of-flight experiments for nuclear structure and astrophysics

Neutron-rich isotopes are atomic nuclei with a large neutron excess compared to their stable counter parts. Their study provides essential information to understand the properties of the nuclear interaction, and to model nuclear processes in extreme astrophysical environments where neutron-rich isotopes drive the chains of nuclear reactions. Experimentally, these unstable isotopes are difficult to study because of their short half-lives and low production yields at particle accelerator laboratories. The TOF-Bρ technique is a mass measurement technique specialized for experiments with fast beams of short-lived radioactive isotopes. In this project we used the technique for two experiments performed at the National Superconducting Cyclotron Laboratory to measure new masses of isotopes in the region of 112 Mo and 46 S. The experiments at the NSCL were complemented by the development of new timing radiation detectors and experimental techniques to improve the performance and reach of mass measurements on neutron-rich isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FHR Process Instruments

Fluoride salt-cooled High temperature Reactors (FHRs) are entering into early phase engineering development. Initial candidate technologies have been identified to measure all of the required process variables. The purpose of this paper is to describe the proposed measurement techniques in sufficient detail to enable assessment of the proposed instrumentation suite and to support development of the component technologies. This paper builds upon the instrumentation chapter of the recently published FHR technology development roadmap. Locating instruments outside of the intense core radiation and high-temperature fluoride salt environment significantly decreases their environmental tolerance requirements. Under operating conditions, FHR primary coolant salt is a transparent, low-vapor-pressure liquid. Consequently, FHRs can employ standoff optical measurements from above the salt pool to assess in-vessel conditions. For example, the core outlet temperature can be measured by observing the fuel s blackbody emission. Similarly, the intensity of the core s Cerenkov glow indicates the fission power level. Short-lived activation of the primary coolant provides another means for standoff measurements of process variables. The primary coolant flow and neutron flux can be measured using gamma spectroscopy along the primary coolant piping. FHR operation entails a number of process measurements. Reactor thermal power and core reactivity are the most significant variables for process control. Thermal power can be determined by measuring the primary coolant mass flow rate and temperature rise across the core. The leading candidate technologies for primary coolant temperature measurement are Au-Pt thermocouples and Johnson noise thermometry. Clamp-on ultrasonic flow measurement, that includes high-temperature tolerant standoffs, is a potential coolant flow measurement technique. Also, the salt redox condition will be monitored as an indicator of its corrosiveness. Both electrochemical techniques and optical spectroscopy are candidate fluoride salt redox measurement methods. Coolant level measurement can be performed using radar-level gauges located in standpipes above the reactor vessel. While substantial technical development remains for most of the instruments, industrially compatible instruments based upon proven technology can be reasonably extrapolated from the current state of the art.

FHR↗

Quantitative Characterization of Nanostructured Materials

The two-and-a-half day symposium on the "Quantitative Characterization of Nanostructured Materials" will be the first comprehensive meeting on this topic held under the auspices of a major U.S. professional society. Spring MRS Meetings provide a natural venue for this symposium as they attract a broad audience of researchers that represents a cross-section of the state-of-the-art regarding synthesis, structure-property relations, and applications of nanostructured materials. Close interactions among the experts in local structure measurements and materials researchers will help both to identify measurement needs pertinent to real-world materials problems and to familiarize the materials research community with the state-of-the-art local structure measurement techniques. We have chosen invited speakers that reflect the multidisciplinary and international nature of this topic and the need to continually nurture productive interfaces among university, government and industrial laboratories. The intent of the symposium is to provide an interdisciplinary forum for discussion and exchange of ideas on the recent progress in quantitative characterization of structural order in nanomaterials using different experimental techniques and theory. The symposium is expected to facilitate discussions on optimal approaches for determining atomic structure at the nanoscale using combined inputs from multiple measurement techniques.

36 MATERIALS SCIENCE↗

Optical and Laser-based Measurements for NASA’s Artemis Program

NASA and their partners are on the cusp of embarking on a series of space missions to the moon and beyond, collectively known as the Artemis Program. The Artemis I mission is scheduled for launch in late November 2022. This talk briefly summarizes the upcoming Artemis missions and describes laser and optical measurement technique development and application to ground and flight tests related to, or inspired by, the Artemis program. In particular, development and application of three different measurement techniques (planar laser-induced fluorescence [PLIF], femtosecond laser electronic excitation and tagging [FLEET] and photogrammetry) are described. These techniques have been applied to study vehicle launch, lunar landing, and earth entry. Such optical and laser-based instrumentation can provide unique qualitative and quantitative information to inform the underlying physics of space flight while also providing benchmark data for validating ever advancing predictive codes.

Artemis Program↗