Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Authigenic Mineral Texture in Submarine 1979 Basalt Drill Core, Surtsey Volcano, Iceland

Micrometer-scale maps of authigenic microstructures in submarine basaltic tuff from a 1979 Surtsey volcano, Iceland, drill core acquired 15 years after eruptions terminated describe the initial alteration of oceanic basalt in a low-temperature hydrothermal system. An integrative investigative approach uses synchrotron source X-ray microdiffraction, microfluoresence, micro-computed tomography, and scanning transmission electron microscopy coupled with Raman spectroscopy to create finely resolved spatial frameworks that record a continuum of alteration in glass and olivine. Microanalytical maps of vesicular and fractured lapilli in specimens from 157.1-, 137.9-, and 102.6-m depths and borehole temperatures of 83, 93.9, and 141.3 °C measured in 1980, respectively, describe the production of nanocrystalline clay mineral, zeolites, and Al-tobermorite in diverse microenvironments. Irregular alteration fronts at 157.1-m depth resemble microchannels associated with biological activity in older basalts. By contrast, linear microstructures with little resemblance to previously described alteration features have nanocrystalline clay mineral (nontronite) and zeolite (amicite) texture. The crystallographic preferred orientation rotates around an axis parallel to the linear feature. Raman spectra indicating degraded and poorly ordered carbonaceous matter of possible biological origin are associated with nanocrystalline clay mineral in a crystallographically oriented linear microstructure in altered olivine at 102.6 m and with subcircular nanoscale cavities in altered glass at 137.9-m depth. Although evidence for biotic processes is inconclusive, the integrated analyses describe the complex organization of previously unrecognized mineral texture in very young basalt. In conclusion, they provide a foundational mineralogical reference for longitudinal, time-lapse characterizations of palagonitized basalt in oceanic environments.

58 GEOSCIENCES↗

Low cost and massively parallel force spectroscopy with fluid loading on a chip

Current approaches for single molecule force spectroscopy are typically constrained by low throughput and high instrumentation cost. Herein, a low-cost, high throughput technique is demonstrated using microfluidics for multiplexed mechanical manipulation of up to ~4000 individual molecules via molecular fluid loading on-a-chip (FLO-Chip). The FLO-Chip consists of serially connected microchannels with varying width, allowing for simultaneous testing at multiple loading rates. Molecular force measurements are demonstrated by dissociating Biotin-Streptavidin and Digoxigenin-AntiDigoxigenin interactions along with unzipping of double stranded DNA of varying sequence under different dynamic loading rates and solution conditions. Rupture force results under varying loading rates and solution conditions are in good agreement with prior studies, verifying a versatile approach for single molecule biophysics and molecular mechanobiology. FLO-Chip enables straightforward, rapid, low-cost, and portable mechanical testing of single molecules that can be implemented on a wide range of microscopes to broaden access and may enable new applications of molecular force spectroscopy.

42 ENGINEERING↗

Time-resolved RIXS experiment with pulse-by-pulse parallel readout data collection using X-ray free electron laser

Abstract Time-resolved resonant inelastic X-ray scattering (RIXS) is one of the developing techniques enabled by the advent of X-ray free electron laser (FEL). It is important to evaluate how the FEL jitter, which is inherent in the self-amplified spontaneous emission process, influences the RIXS measurement. Here, we use a microchannel plate (MCP) based Timepix soft X-ray detector to conduct a time-resolved RIXS measurement at the Ti L 3 -edge on a charge-density-wave material TiSe 2 . The fast parallel Timepix readout and single photon sensitivity enable pulse-by-pulse data acquisition and analysis. Due to the FEL jitter, low detection efficiency of spectrometer, and low quantum yield of RIXS process, we find that less than 2% of the X-ray FEL pulses produce signals, preventing acquiring sufficient data statistics while maintaining temporal and energy resolution in this measurement. These limitations can be mitigated by using future X-ray FELs with high repetition rates, approaching MHz such as the European XFEL in Germany and LCLS-II in the USA, as well as by utilizing advanced detectors, such as the prototype used in this study.

36 MATERIALS SCIENCE↗

In situ molecular imaging of hydrated biofilm in a microfluidic reactor by ToF-SIMS

The first results of using a novel single channel microfluidic reactor to enable Shewanella biofilm growth and in situ characterization using time-of-flight secondary ion mass spectrometry (ToF-SIMS) in the hydrated environment are presented. The new microfluidic interface allows direct probing of the liquid surface using ToF-SIMS, a vacuum surface technique. The detection window is an aperture of 2 m in diameter on a thin silicon nitride (SiN) membrane and it allows direct detection of the liquid surface. Surface tension of the liquid flowing inside the microchannel holds the liquid within the aperture. ToF-SIMS depth profiling was used to drill through the SiN membrane and the biofilm grown on the substrate. In situ 2D imaging of the biofilm in hydrated state was acquired, providing spatial distribution of the chemical compounds in the biofilm system. This data was compared with a medium filled microfluidic reactor devoid of biofilm and dried biofilm samples deposited on clean silicon wafers. Principle Component Analysis (PCA) was used to investigate these observations. Our results show that imaging biofilms in the hydrated environment using ToF-SIMS is possible using the unique microfluidic reactor. Moreover, characteristic biofilm fatty acids fragments were observed in the hydrated biofilm grown in the microfluidic channel, illustrating the advantage of imaging biofilm in its native environment.

Environmental Molecular Sciences Laboratory↗

Optofluidic-Tunable Color Filters And Spectroscopy Based On Liquid-Crystal Microflows

The integration of color filters with microfluidics has attracted substantial attention in recent years, for on-chip absorption, fluorescence, or Raman analysis. We describe such tunable filters based on the micro-flow of liquid crystals. The filter operation is based on the wavelength dependent liquid crystal birefringence that can be tuned by modifying the flow velocity field in the microchannel. The latter is possible both temporally and spatially by varying the inlet pressure and the channel geometry respectively. We explored the use of these optofluidic filters for on-chip absorption spectroscopy; by integrating the distance dependent color filter with a dye-filled micro-channel, the absorption spectrum of a dye could be measured. Liquid crystal microflows simplify substantially the optofluidic integration, actuation and tuning of color filters for lab-on-a-chip spectroscopic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-ablation sampling for inductively coupled plasma distance-of-flight mass spectrometry

An inductively coupled plasma distance-of-flight mass spectrometer (ICP-DOFMS) has been coupled with laser-ablation (LA) sample introduction for the elemental analysis of solids. ICP-DOFMS is well suited for the analysis of laser-generated aerosols because it offers both high-speed mass analysis and simultaneous multi-elemental detection. Here, we evaluate the analytical performance of the LA-ICP-DOFMS instrument, equipped with a microchannel plate-based imaging detector, for the measurement of steady-state LA signals, as well as transient signals produced from single LA events. Steady-state detection limits are 1 mg g1, and absolute single-pulse LA detection limits are 200 fg for uranium; the system is shown capable of performing time-resolved single-pulse LA analysis. By leveraging the benefits of simultaneous multi-elemental detection, we also attain a good shot-to-shot reproducibility of 6% relative standard deviation (RSD) and isotope-ratio precision of 0.3% RSD with a 10 s integration time.

Gundlach-Graham, Alexander W.↗

Concurrent coupling of atomistic simulation and mesoscopic hydrodynamics for flows over soft multi-functional surfaces

We develop an e?cient parallel multiscale method that bridges the atomistic and mesoscale regimes, from nanometers to microns and beyond, via concurrent coupling of atomistic simulation and mesoscopic dynamics. In particular, we combine an all-atom molecular dynamics (MD) description for specific atomistic details in the vicinity of the functional surface with a dissipative particle dynamics (DPD) approach that captures mesoscopic hydrodynamics in the domain away from the functional surface. In order to achieve a seamless transition in dynamic properties we endow the MD simulation with a DPD thermostat, which is validated against experimental results by modeling water at di?erent temperatures. We then validate the MD-DPD coupling method for transient Couette and Poiseuille flows, demonstrating that the concurrent MD-DPD coupling can resolve accurately the continuumbased analytical solutions. Subsequently, we simulate shear flows over grafted polydimethylsiloxane (PDMS) surfaces (polymer brushes) for various grafting densities, and investigate the slip flow as a function of the shear stress. We verify that a ‘‘universal’’ power law exists for the slip length, in agreement with published results. Having validated the MD-DPD coupling method, we simulate timedependent flows past an endothelial glycocalyx layer (EGL) in a microchannel. Coupled simulation results elucidate the dynamics of the EGL changing from an equilibrium state to a compressed state under shear by aligning the molecular structures along the shear direction. MD-DPD simulation results agree well with results of a single MD simulation, but with the former more than two orders of magnitude faster than the latter for system sizes above one micron.

Wang, Yuying↗

Experiments and computations of microfluidic liquid–liquid flow patterns

We study two-phase liquid–liquid flow patterns in a 500 μm capillary microchannel for four biphasic systems: ethyl acetate/water, 2-pentanol/water, methyl isobutyl ketone/water, and heptane/water. Flow visualization experiments using laser induced fluorescence (LIF) reveal a total of 7 different flow patterns for all solvent pairs, namely slug flow, droplet flow, slug-droplet flow, parallel, annular, dispersed, and irregular flow. A map of different flow patterns was built to delineate the origin of their formation. We find conventional dimensionless groups are insufficient to uniquely identify the flow patterns. Computational fluid dynamics (CFD) modeling in OpenFOAM shows agreement with the experimental flow patterns for most of the two-phase flows. Principal component analysis reduces the dimensionality of potential descriptors of flow patterns and, unlike prior work using two dimensionless numbers, determines six important features that describe >95% of the variance of the experimental flow patterns. These include the total flow rate, the flow rate ratio between the two phases, the capillary and Ohnesorge numbers of the aqueous phase, and the Weber number and velocity of the organic phase. Lastly, we build a decision-tree model to further regress the data and identify the critical features and demonstrate an accuracy in predicting the flow patterns of up to 93%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Microplasma generation in a sealed microfluidic glass chip using a water electrode

A microplasma was generated in a sealed microfluidic glass chip for the application of the miniaturized chemical detection system, especially for water contaminants. The behavior of a microbubble as well as a microplasma was observed using a 1% NaCl solution with no metal contact in a sealed glass microchannel. A microplasma formed by water contents excluding air or inert gas showed clear emission spectrum in UV, visible, and near IR range. The detection of lead was demonstrated by measuring the intensity of the Pb emission line (at 406 nm) with respect to the concentration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion flow convergence in spherical inertial electrostatic confinement devices

Data collected with automated double and single probes is used to evaluate the convergence of ion flow in a spherical inertial electrostatic confinement device operated in glow discharge mode. A novel method based on the invasive nature of electrostatic probes is used to evaluate the width of the ion density peak. Over much of the star mode discharge regime, it is found that R{sub c}/R{sub g}{approx}0.125 to 0.167 where R{sub c} is the ion core radius, and R{sub g} is the radius of the cathode grid, which remains fixed for all discharge conditions considered here. Near the star-to-jet mode transition, the technique shows that R{sub c}/R{sub g}{approx}0.250, in agreement with direct measurements of the ion density profile with the double probe. The influences of space charge accumulation and cathode grid deflection are evaluated with floating potential measurements and tangential electric field measurements, respectively. It is concluded that the observed core growth is a result of ion microchannel degradation caused by an increased frequency in inelastic and elastic molecular encounters, while the effects of space charge are negligible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of ion flow dynamics in an inertial electrostatic confinement device through sequential grid construction

Experiments were performed to understand the dynamics of the ion flow in an inertial electrostatic confinement (IEC) device. This was done by monitoring the fusion rate as the symmetry of the grid was increased starting with a single loop all the way until the entire grid is constructed. The fusion rate was observed to increase with grid symmetry and eventually saturate. A single loop grid was observed to generate a cylindrical ({approx}line) fusion source. The ion flow distribution was measured by introducing fine wires across a single loop of the grid in the form of a chord of a circle (chord wires). This study revealed that with increased symmetry of the cathode grid wires the convergence of the ions improves. The chord wires provided electrons for ionization even at low pressures ({approx}6.67 mPa) and helped sustain the plasma. The impinging ions heat these wires locally and the temperature of the wires was measured using an infrared thermometer that was used to understand the ion flow distribution across the cathode grid. The presence of the grid wires seems to affect the fusion rate more drastically than previously thought (was assumed to be uniform around the central grid). Most of the fusion reactions were observed to occur in the ion microchannels that form in gaps between the cathode wires. This work helps understand the fusion source regimes and calibrate the IEC device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of relativistic electron beam production and transport in high-intensity laser interaction with a wire target by integrated LSP modeling

The results of a numerical study of high-intensity short-pulse laser interaction with wire targets are presented. Fast electron production and transport in solid density plasma is modeled using the implicit hybrid particle-in-cell code LSP [D. R. Welch et al., Phys. Plasmas 13, 063105 (2006)]. These simulations were performed with realistic target size and laser parameters and over times much longer than the laser pulse. Nonlinear interaction processes, i.e., microchanneling and density steepening, have been observed. The spectrum of the relativistic electrons produced has a reduced slope temperature compared to that predicted by ponderomotive scaling. Preformed underdense plasma has been found to bottleneck fast electrons due to the intense magnetic fields generated near the critical surface. In a thin long wire target, the overall propagation length of the fast electrons is about 160 {mu}m; however, surface fields guide a small fraction of electrons to longer distances. These results are in good agreement with the experiments and have demonstrated that the modeling of electron transport relevant to fast ignition can be pursued in an integrated manner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reaction-diffusion analysis for one-step plasma etching and bonding of microfluidic devices

A self-similar reaction front develops in reactive ion etching when the ions penetrate channels of shallow height h. This relates to the patterning of microchannels using a single-step etching and bonding, as described by Rhee et al. [Lab Chip 5, 102 (2005)]. Experimentally, we report that the front location scales as x{sub f{approx}}ht{sup 1/2} and the width is time-invariant and scales as {delta}{approx}h. Mean-field reaction-diffusion theory and Knudsen diffusion give a semiquantitative understanding of these observations and allow optimization of etching times in relation to bonding requirements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A design for a compact time-of-flight mass spectrometer

The design of a prototype, compact time-of-flight (TOF) mass spectrometer (MS) is described. The system primarily consists of an ion acceleration/focusing/steering assembly (AFSA), an 8 cm field-free region, a 4 cm, dual-stage reflectron and a miniature microchannel plate detector. Consequently, the resulting flight length of the system is 12 cm. The system has been designed with the capability to sample directly from atmosphere at ambient pressures. This is accomplished through the use of an electrodynamic ion funnel, housed in an intermediate-vacuum chamber that is coupled to the inlet of the TOF chamber. TOF spectra were obtained using noble gases (Ar, Kr and Xe) as test chemicals. These measured flight times were used to probe the performance of the instrument. A temporal resolution (tflight/Δt) of approximately 125, acquired using 129Xe+, has been measured for the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a general method for obtaining the geometry of microfluidic networks

In the present study, a general method for geometry of fluidic networks is developed with emphasis on pressure-driven flows in the microfluidic applications. The design method is based on general features of network's geometry such as cross-sectional area and length of channels. Also, the method is applicable to various cross-sectional shapes such as circular, rectangular, triangular, and trapezoidal cross sections. Using constructal theory, the flow resistance, energy loss and performance of the network are optimized. Also, by this method, practical design strategies for the fabrication of microfluidic networks can be improved. The design method enables rapid prediction of fluid flow in the complex network of channels and is very useful for improving proper miniaturization and integration of microfluidic networks. Minimization of flow resistance of the network of channels leads to universal constants for consecutive cross-sectional areas and lengths. For a Y-shaped network, the optimal ratios of consecutive cross-section areas (A{sub i+1}/A{sub i}) and lengths (L{sub i+1}/L{sub i}) are obtained as A{sub i+1}/A{sub i} = 2{sup −2/3} and L{sub i+1}/L{sub i} = 2{sup −1/3}, respectively. It is shown that energy loss in the network is proportional to the volume of network. It is also seen when the number of channels is increased both the hydraulic resistance and the volume occupied by the network are increased in a similar manner. Furthermore, the method offers that fabrication of multi-depth and multi-width microchannels should be considered as an integral part of designing procedures. Finally, numerical simulations for the fluid flow in the network have been performed and results show very good agreement with analytic results.

36 MATERIALS SCIENCE↗

Microstructure of sheared monosized colloidal suspensions resulting from hydrodynamic and electrostatic interactions

Hydrodynamic and near-particle interactions in sheared suspensions are communicated through suspension microstructure to produce a wide variety of rheological behaviors. To characterize this microstructure, the individual positions of monosized silica particles flowing through a microchannel are obtained with near simulation-level detail. The pair distribution functions of the microstructure at moderate to high Péclet number shear rates are very similar to previous numerical studies. Viscometric functions calculated based on the detailed microstructure obtained through this technique show qualitative agreement with computational results. These results elucidate the origins of shear-thickening of suspensions at high shear rates. While efforts are taken to screen electrostatic interactions to study hydrodynamic and Brownian interactions, the role of electrostatic interaction between particles is also investigated by reducing suspension ionic strength. These non-hydrodynamic electrostatic interactions result in a loss of anisotropy that generally agrees with previous findings of “soft” particle systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗