Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Intrinsic Properties of Individual Constituents of Silicon-Electrolyte Interphase

The stabilization of a solid electrolyte interphase (SEI) is one of the great challenges to utilize superior theoretical capacity (about 3,600 mAh g-1, almost 10 times higher than that of graphite) of a silicon (Si) as an anode in a next-generation advanced lithium-ion battery (LIB). A SEI remains a poorly understood and hardly studied topic relative to the research devoted to battery components due to its intrinsic properties of complexity, reactivity and continuous evolution. However, the SEI plays a key role in prevention of further electrolyte reduction and desolvation of Li+ ions, which is directly related to electrochemical performance, lifetime and safety of batteries. For example, the unstable SEI on a Si anode leads to initial irreversible capacity losses, poor cycling stability and a limited cycle life. 2-4 In this study each 'individual' component of SEI on a Si anode was prepared as a thin film, and the physical, electrochemical, mechanical and structural properties of prepared films were characterized using a variety of analytical equipment including electrochemical impedance spectroscopy, operando X-ray photoelectron spectroscopy, atomic force microscope, Fourier-transform infrared spectroscopy, scanning spreading resistance microscopy and time-of-flight secondary ion mass spectrometry. This study can provide a strong guidance to aid in the development of new electrolytes, additives and binders to stabilize SEI layer on a silicon anode by identifying beneficial components and providing mechanical explanation of a variety of reactions and phenomena in a SEI.

14 SOLAR ENERGY↗

Watching Domains Grow: In-situ studies of polarization switching by combined Scanning Probe and Scanning Transmission Electron Microscopy

Ferroelectric domain nucleation and growth in multiferroic BiFeO{sub 3} films is observed directly by applying a local electric field with a conductive tip inside a scanning transmission electron microscope. The nucleation and growth of a ferroelastic domain and its interaction with pre-existing 71{sup o} domain walls are observed and compared with the results of phase-field modeling. In particular, a preferential nucleation site and direction-dependent pinning of domain walls are observed due to slow kinetics of metastable switching in the sample without a bottom electrode. These in situ spatially resolved observations of a first-order bias-induced phase transition reveal the mesoscopic mechanisms underpinning functionality of a wide range of multiferroic materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning tunneling microscopic analysis of Cu(In,Ga)Se{sub 2} epitaxial layers

Scanning tunneling microscopy (STM) measurements have been made on single-crystal epitaxial layers of CuInSe{sub 2} grown on GaAs substrates. Results were obtained for as-grown, air-exposed, and cleaned surfaces; in situ cleaved surfaces; surfaces sputtered and annealed in the STM system; and samples prepared by a light chemical etch. Conventional constant-current topographs, current-voltage curves, and current imaging tunneling spectroscopy (CITS) scans were obtained. Topographic images show that the surfaces appear rough on the atomic scale and often exhibit regular features consistent with a previously proposed surface ad-dimer reconstruction. CITS scans show a spatially varying energy gap consistent with band-edge fluctuations on a scale of a few atomic spacings. Energy variations were observed in both band edges. Although quantitative description of the magnitude of these fluctuations is difficult, the fluctuations on the atomic scale appear much larger than observed by methods such as photoluminescence, which average over larger volumes.

36 MATERIALS SCIENCE↗

Validity of Machine Learning in the Quantitative Analysis of Complex Scanning Near-Field Optical Microscopy Signals Using Simulated Data

Scattering-type scanning near-field optical microscope (s-SNOM) is a modern technique for subdiffractional optical imaging and spectroscopy. Over the past two decades, tremendous efforts have been devoted to modeling complex tip-sample interactions in s-SNOM, aimed at understanding the electrodynamics of materials at the nanoscale. However, due to complexities in analytical methods and the limited computation power for fully numerical simulations, compromises must be made to facilitate the modeling of tip-sample interaction, such as using quasistatic approximation or unrealistic tip geometries. Here, we apply a variety of widely utilized machine-learning methods, including k nearest neighbor and feedforward neural network etc. to study the phase-resolved spectroscopic near-field response. With only a small set of training data, which is simulated using the finite-dipole model, we demonstrate that the relation between the experimental near-field signal and sample optical constant can be one to one mapped without the need for tip modeling: for a given material with a moderate dielectric function, its complex near-field spectrum can be accurately determined within the mid-IR spectral range, and vice versa. Our preliminary study sets the stage for future exploration using real experimental data. Our method is beneficial for processing the increasing amount of data accumulated across many research groups and especially useful for user facilities such as synchrotron-based national laboratories where a large amount of data is generated on a daily basis.

36 MATERIALS SCIENCE↗

Ferroelectric Switching by the Grounded Scanning Probe Microscopy Tip

The process of polarization reversal by the tip of scanning probe microscope was intensively studied for last two decades. Number of the abnormal switching phenomena was reported by the scientific groups worldwide. In particularly it was experimentally and theoretically shown that slow dynamics of the surface screening controls kinetics of the ferroelectric switching, backswitching and relaxation and presence of the charges carriers on the sample surface and in the sample bulk significantly change polarization reversal dynamics. Here we experimentally demonstrated practical possibility of the history dependent polarization reversal by the grounded SPM tip. This phenomenon was attributed to induction of the slowly dissipating charges into the surface of the grounded tip that enables polarization reversal under the action of the produced electric field. Analytical and numerical electrostatic calculations allow additional insight into nontrivial abnormal switching phenomena reported earlier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polymer microscopy

Detection of polyethylene single crystals deposited on reflecting substrate using incident light microscope

POLYETHYLENE↗

Fundamental Studies of Solidification in Microgravity Using Real-Time X-Ray Microscopy

This research applies a state of the art X-ray Transmission Microscope, XTM, to image (with resolutions up to 3 micrometers) the solidification of metallic or semiconductor alloys in real-time. We have successfully imaged in real-time: interfacial morphologies, phase growth, coalescence, incorporation of phases into the growing interface, and the solute boundary layer in the liquid at the solid-liquid interface. We have also measured true local growth rates and can evaluate segregation structures in the solid; a form of in-situ metallography. During this study, the growth of secondary phase fibers and lamellae from eutectic and monotectic alloys have been imaged during solidification, in real-time, for the first time in bulk metal alloys. Current high resolution X-ray sources and high contrast X-ray detectors have advanced to allow systematic study of solidification dynamics and the resulting microstructure. We have employed a state-of-the-art sub-micron source with acceleration voltages of 10-100 kV to image solidification of metals. One useful strength of the XTM stems from the manner an image is formed. The radiographic image is a shadow formed by x-ray photons that are not absorbed as they pass through the specimen. Composition gradients within the specimen cause variations in absorption of the flux such that the final image represents a spatial integral of composition (or thickness). The ability to image these features in real-time enables more fundamental and detailed understanding of solidification dynamics than has previously been possible. Hence, application of this technique towards microgravity experiments will allow rigorous testing of critical solidification models.

Curreri, Peter A.↗

High-Activity Microscopic Nuclear-Sourced Particles to Investigate Nuclear Release Scenarios - 18026

Advances in microscopy and materials analysis have allowed for the study of materials at resolutions not previously attainable a decade ago. Such information extends to not only their existence, but also their composition, the likely source term and if applicable, their short or long-term environmental stability. This work describes the analysis undertaken on the larger 'ejecta' type of particulate collected following the INES Level 7 incident at the Fukushima Daiichi Nuclear Power Plant in March 2011. However, the methods and procedures employed during this work, on material with enormously contrasting characteristics, have far wider applications within nuclear forensics, safeguards, security and material compliance. Resulting from the analysis of micron-scale 'atmospheric' material in previous works have been able to derive information relating to the emission and subsequent transportation characteristics of the release event, as well as determining the local-scale impacts of this radioactive fallout. This analysis of the larger-scale (100's of micron) 'ejecta' material, collected from closer to the plant, has been able to reveal details pertaining to the specific in-reactor conditions at the time of the release as well as the nature of the explosion events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Revealing the temperature history in concrete after fire exposure by microscopic analysis

Concrete structures behave in most cases very well during a fire, after which it is often possible to repair or strengthen the structure to a certain level. This could result in important economic benefits, as costs for demolition and rebuilding can be avoided and the building can be reused faster. In this paper three methods for determining the maximum temperature to which a concrete structure was submitted during a fire are studied. Knowledge of the temperature distribution is necessary to assess the overall damage of a concrete structure. First, the physico-chemical transformations of heated concrete are investigated with scanning electron microscopy (SEM). Secondly, the features visible under the polarising and fluorescent microscope (PFM) are discussed. And third, the influence of heat on the colour of the aggregates is analysed.

36 MATERIALS SCIENCE↗

Compact Video Microscope Imaging System Implemented in Colloid Studies

Long description Photographs showing fiber-optic light source, microscope and charge-coupled discharge (CCD) camera head connected to camera body, CCD camera body feeding data to image acquisition board in PC, and Cartesian robot controlled via PC board. The Compact Microscope Imaging System (CMIS) is a diagnostic tool with intelligent controls for use in space, industrial, medical, and security applications. CMIS can be used in situ with a minimum amount of user intervention. This system can scan, find areas of interest in, focus on, and acquire images automatically. Many multiple-cell experiments require microscopy for in situ observations; this is feasible only with compact microscope systems. CMIS is a miniature machine vision system that combines intelligent image processing with remote control. The software also has a user-friendly interface, which can be used independently of the hardware for further post-experiment analysis. CMIS has been successfully developed in the SML Laboratory at the NASA Glenn Research Center and adapted for use for colloid studies and is available for telescience experiments. The main innovations this year are an improved interface, optimized algorithms, and the ability to control conventional full-sized microscopes in addition to compact microscopes. The CMIS software-hardware interface is being integrated into our SML Analysis package, which will be a robust general-purpose image-processing package that can handle over 100 space and industrial applications.

McDowell, Mark↗

Two-Photon Fluorescence Microscopy Developed for Microgravity Fluid Physics

Recent research efforts within the Microgravity Fluid Physics Branch of the NASA Glenn Research Center have necessitated the development of a microscope capable of high-resolution, three-dimensional imaging of intracellular structure and tissue morphology. Standard optical microscopy works well for thin samples, but it does not allow the imaging of thick samples because of severe degradation caused by out-of-focus object structure. Confocal microscopy, which is a laser-based scanning microscopy, provides improved three-dimensional imaging and true optical sectioning by excluding the out-of-focus light. However, in confocal microscopy, out-of-focus object structure is still illuminated by the incoming beam, which can lead to substantial photo-bleaching. In addition, confocal microscopy is plagued by limited penetration depth, signal loss due to the presence of a confocal pinhole, and the possibility of live-cell damage. Two-photon microscopy is a novel form of laser-based scanning microscopy that allows three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon microscopy, it utilizes the nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption because of the nonlinear (i.e., quadratic) electric field dependence, so an ultrafast pulsed laser source must typically be employed. On the other hand, this stringent energy density requirement effectively localizes fluorophore excitation to the focal volume. Consequently, two-photon microscopy provides optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction in photo-damage because of the longer excitation wavelength, a reduction in background fluorescence, and a 4 increase in penetration depth over confocal methods because of the reduction in Rayleigh scattering.

Fischer, David G.↗

Holographic Microscopy System

Holographic system originally developed for testing theories of two systems used for measurements of aerosols, particles in transparent medium or microscopic biological specimens. Holograms are recorded in 3 - to 5milli-second exposures on high-resolution holographic film. In-line holographic microscopy system includes construction or recording system and reconstruction or playback system.

Witherow, W. K.↗

Some surface characteristics and gas interactions of Apollo 14 fines and rock fragments.

Comprehensive survey of the physical surface characteristics of Apollo 14 fines, two fragments of a breccia (14321), and a crystalline rock (14310). The survey was carried out with optical and both scanning and transmission electron microscopy and by studying the adsorption of a variety of gases including nitrogen, hydrogen, and water vapor. Our objective in the optical microscope study was to relate the visible geological and petrological features to the surface properties. Electron microscopy particularly helped relate surface roughness and particle fusion to gas adsorption and pore structure. The fine sample (14163,111) had a surface area of 0.210 sq m/g and a helium density of 2.9 g/cc. Similar values have been observed with breccia fragments. Other observations include physical adsorption of molecular hydrogen at low temperatures and of water vapor at ambient temperatures. It is concluded that these particular lunar materials, while capable of adsorbing water vapor, do not retain it for any significant time at low pressures, nor, under lunar conditions, is there any indication of absorption or penetration.

Cadenhead, D. A.↗

Microscopy with ultraviolet surface excitation (MUSE) enables translation of optical biopsy principles to enhance life science education

The translation of microscopy with ultraviolet surface excitation (MUSE) into a high school science classroom is investigated with the goal of providing a suitable new modality to enhance life science education. A key part of this effort is the development of laboratory exercises that can integrate the advanced capabilities of MUSE into a classroom setting. MUSE utilizes the unique property of ultraviolet light at wavelengths between 250 and 285 nm to propagate about 10 um into tissues, thus illuminating only the top cell layer. Furthermore this illumination is provided by a low-power UV LED source, which enables one to cost-efficiently implement this method into the educational environment. MUSE in education can eliminate the need for premade microscope slides and provide a far more engaging and rewarding experience for students.

47 OTHER INSTRUMENTATION↗

Morphological classification of bioaerosols from composting using scanning electron microscopy

Highlights: • Bioaerosols were captured using the filter method. • Bioaerosols were analysed using scanning electron microscope. • Bioaerosols were classified on the basis of morphology. • Single small cells were found more frequently than aggregates and larger cells. • Smaller cells may disperse further than heavier aggregate structures. - Abstract: This research classifies the physical morphology (form and structure) of bioaerosols emitted from open windrow composting. Aggregation state, shape and size of the particles captured are reported alongside the implications for bioaerosol dispersal after release. Bioaerosol sampling took place at a composting facility using personal air filter samplers. Samples were analysed using scanning electron microscopy. Particles were released mainly as small (<1 μm) single, spherical cells, followed by larger (>1 μm) single cells, with aggregates occurring in smaller proportions. Most aggregates consisted of clusters of 2–3 particles as opposed to chains, and were <10 μm in size. No cells were attached to soil debris or wood particles. These small single cells or small aggregates are more likely to disperse further downwind from source, and cell viability may be reduced due to increased exposure to environmental factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bifurcation, chaos, and scan instability in dynamic atomic force microscopy

The dynamical motion at any point on the cantilever of an atomic force microscope can be expressed quite generally as a superposition of simple harmonic oscillators corresponding to the vibrational modes allowed by the cantilever shape. Central to the dynamical equations is the representation of the cantilever-sample interaction force as a polynomial expansion with coefficients that account for the interaction force “stiffness,” the cantilever-to-sample energy transfer, and the displacement amplitude of cantilever oscillation. Renormalization of the cantilever beam model shows that for a given cantilever drive frequency cantilever dynamics can be accurately represented by a single nonlinear mass-spring model with frequency-dependent stiffness and damping coefficients [S. A. Cantrell and J. H. Cantrell, J. Appl. Phys. 110, 094314 (2011)]. Application of the Melnikov method to the renormalized dynamical equation is shown to predict a cascade of period doubling bifurcations with increasing cantilever drive force that terminates in chaos. The threshold value of the drive force necessary to initiate bifurcation is shown to depend strongly on the cantilever setpoint and drive frequency, effective damping coefficient, nonlinearity of the cantilever-sample interaction force, and the displacement amplitude of cantilever oscillation. The model predicts the experimentally observed interruptions of the bifurcation cascade for cantilevers of sufficiently large stiffness. Operational factors leading to the loss of image quality in dynamic atomic force microscopy are addressed, and guidelines for optimizing scan stability are proposed using a quantitative analysis based on system dynamical parameters and choice of feedback loop parameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase retrieval using polychromatic illumination for transmission X-ray microscopy

An alternative method for quantitative phase retrieval in a transmission X-ray microscope system at sub-50-nm resolution is presented. As an alternative to moving the sample in the beam direction in order to analyze the propagation-introduced phase effect, we have illuminated the TXM using X-rays of different energy without any motor movement in the TXM system. Both theoretical analysis and experimental studies have confirmed the feasibility and the advantage of our method, because energy tuning can be performed with very high energy resolution using a double crystal monochromator at a synchrotron beam line, and there is zero motor error in TXM system in our approach. High-spatial-resolution phase retrieval is accomplished using the proposed method.

47 OTHER INSTRUMENTATION↗