Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mix Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Ultracoatings: Enabling Energy and Power Solutions in High Contact Stress Environments through next-generation Nanocoatings Final Technical Report

A review of current commercially available, industrial-grade, low friction coatings will show that interfacial contact pressures nearing 1GPa (~150ksi) inherently limit surface engineering solutions like WC, TiN, TiAlN, and so forth. Extremely hard coatings, then, are often pursued as the principle path, although they too are not without significant limitations. A majority of these compounds are inherently brittle in nature or may not pair well with their mating substrate. In either case, their durability in high contact stress environments is compromised. In parallel to thin film coatings, many conventional surface treatments do not yield an interface hard enough to withstand extreme stresses under load. New research into advanced, nanocomposite materials like (Ti, Zr)B 2 shows great promise. Bulk compacts of this compound have demonstrated an order of magnitude better wear resistance than current offerings, notably materials like tungsten carbide. At a laboratory level, the (Ti,Zr)B 2 nanocomposite material exhibited abrasive and erosive wear resistance nearly ten times better than existing mixed-phase boride systems. In ASTM abrasion and erosion testing, these new compositions exhibit wear resistance superior to other known advanced materials such as RocTec 500 and 'Borazon' cubic boron nitride. Many significant challenges exist for mass production of (Ti, Zr)B 2 , one of which is the necessary processing technology that is capable of minimizing deleterious impurity phases. Secondly, this material's performance is derived from a synergistic effect of the two materials existing as a single phase structure. While the individual constituents of TiB 2 and ZrB 2 do yield improvements to wear resistance, their singular effects are not as significant. Lastly, deposition of this material on a commercial level requires thorough knowledge of nanocomposite boride solids; the benefits associated with these innovative new materials are just being realized. Advancing this technology, called Ultracoatings, through initial development, scale up, and commercialization to a variety of markets would represent a transformative leap to surface engineering. Several application spaces were considered for immediate implementation of the Ultracoatings technology, including, but not limited to, a drive shaft for an aerospace fuel pump, engine timing components, and dry solids pump hardware for an innovative coal gasifier. The primary focus of the program was to evaluate and screen the performance of the selected (Ti, Zr)B 2 Ultracoatings composition for future development. This process included synthesis of the material for physical vapor deposition, sputtering trials and coating characterization, friction and wear testing on sample coupons, and functional hardware testing. The main project deliverables used to gage the project's adherence to its original objective were: Development of a coating/substrate pairing that exhibits wear rate of 0.1 mg/hour or lower at a 1GPa contact pressure, while achieving a maximum coating cost of $0.10/cm 2 . Demonstrate the aforementioned wear rate in both lubricated and starved lubrication conditions. Although the (Ti, Zr) B 2 coating was not tailored for low friction performance, friction and wear evaluations of the material demonstrated a coefficient of sliding friction as low as 0.09. This suggests that varying the percentage of TiB 2 present in the composite could enhance the materials performance in water-based lubricants. In the aerospace drive shaft application, functional hardware coated with (Ti, Zr)B 2 survived a variety of abuse and long-range durability tests, with contact pressures exceeding 2 GPa. For engine timing components, further work is planned to evaluate the Ultracoatings technology in direct injection and diesel engine conditions. In the final identified application space the dry solids pump hardware, discussions continue on the application of the Ultracoatings technology for those specific components. Full implementation of the technology into the targeted markets equates to a U.S.-based energy savings potential of over 100 trillion BTU per year by 2030. This exceeds the original projection of 60 TBTU/year by 2030.

(Ti,Zr) B2↗

Verification of Unstructured Mesh Capabilities in MCNP6 for Reactor Physics Problems

New unstructured mesh capabilities in MCNP6 (developmental version during summer 2012) show potential for conducting multi-physics analyses by coupling MCNP to a finite element solver such as Abaqus/CAE. Before these new capabilities can be utilized, the ability of MCNP to accurately estimate eigenvalues and pin powers using an unstructured mesh must first be verified. Previous work to verify the unstructured mesh capabilities in MCNP was accomplished using the Godiva sphere, and this work attempts to build on that. To accomplish this, a criticality benchmark and a fuel assembly benchmark were used for calculations in MCNP using both the Constructive Solid Geometry (CSG) native to MCNP and the unstructured mesh geometry generated using Abaqus/CAE. The Big Ten criticality benchmark was modeled due to its geometry being similar to that of a reactor fuel pin. The C5G7 3-D Mixed Oxide (MOX) Fuel Assembly Benchmark was modeled to test the unstructured mesh capabilities on a reactor-type problem.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet)

Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems - a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms - were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplified Space Conditioning in Low-Load Homes: Results from the Fresno, California, Retrofit Unoccupied Test House

Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems -- a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms -- were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating the Effect of Pyridine Vapor Treatment on Perovskite Solar Cells

Perovskite photovoltaics have recently come to prominence as a viable alternative to crystalline silicon based solar cells. In an effort to create consistent and high-quality films, we studied the effect of various annealing conditions as well as the effect of pyridine vapor treatment on mixed halide methylammonium lead perovskite films. Of six conditions tested, we found that annealing at 100°C for 90 minutes followed by 120°C for 15 minutes resulted in the purest perovskite. Perovskite films made using that condition were treated with pyridine for various amounts of time, and the effects on perovskite microstructure were studied using x-ray diffraction, UV-Vis spectroscopy, and time-resolved photoluminescence lifetime analysis (TRPL). A previous study found that pyridine vapor caused perovskite films to have higher photoluminescence intensity and become more homogenous. In this study we found that the effects of pyridine are more complex: while films appeared to become more homogenous, a decrease in bulk photoluminescence lifetime was observed. In addition, the perovskite bandgap appeared to decrease with increased pyridine treatment time. Finally, X-ray diffraction showed that pyridine vapor treatment increased the perovskite (110) peak intensity but also often gave rise to new unidentified peaks, suggesting the formation of a foreign species. It was observed that the intensity of this unknown species had an inverse correlation with the increase in perovskite peak intensity, and also seemed to be correlated with the decrease in TRPL lifetime.

14 SOLAR ENERGY↗

Investigating the Effect of Pyridine Vapor Treatment on Perovskite Solar Cells - Oral Presentation [Slides]

Perovskite photovoltaics have recently come to prominence as a viable alternative to crystalline silicon based solar cells. In an effort to create consistent and high-quality films, we studied the effect of various annealing conditions as well as the effect of pyridine vapor treatment on mixed halide methylammonium lead perovskite films. Of six conditions tested, we found that annealing at 100 degree Celsius for 90 minutes followed by 120 degree Celsius for 15 minutes resulted in the purest perovskite. Perovskite films made using that condition were treated with pyridine for various amounts of time, and the effects on perovskite microstructure were studied using x-ray diffraction, UV-Vis spectroscopy, and time-resolved photoluminescence lifetime analysis (TRPL). A previous study found that pyridine vapor caused perovskite films to have higher photoluminescence intensity and become more homogenous. In this study we found that the effects of pyridine are more complex: while films appeared to become more homogenous, a decrease in bulkphotoluminescence lifetime was observed. In addition, the perovskite bandgap appeared to decrease with increased pyridine treatment time. Finally, X-ray diffraction showed that pyridine vapor treatment increased the perovskite (110) peak intensity but also often gave rise to new unidentified peaks, suggesting the formation of a foreign species. It was observed that the intensity of this unknown species had an inverse correlation with the increase in perovskite peak intensity, and also seemed to be correlated with the decrease in TRPL lifetime.

14 SOLAR ENERGY↗

Demonstration of LED Retrofit Lamps at the Smithsonian Art Museum, Washington, DC

In the fall of 2010, Pacific Northwest National Laboratory contacted Scott Rosenfeld, Lighting Designer for the Smithsonian American Art Museum, to see if the Museum would be willing to participate in a GATEWAY demonstration project in which light-emitting diode (LED) replacement lamps would be used in exhibit space. At that time, the museum industry was concerned about increased damage potential from LEDs and other energy efficient lighting sources that produce a discontinuous spectrum. The Museum agreed to participate, based on a review of the existing literature conducted by Steven Weintraub of Art Preservation Services for the American Institute of Conservation, and subsequent testing of solid-state lighting sources on light sensitive materials performed by Jim Druzik of the Getty Conservation Institute. Thus began the process, which lasted more than a year, of procuring lamp samples and performance data, testing them in the museum workshop, temporarily installing the lamps in one gallery for feedback, and ultimately replacing all traditional incandescent lamps in one gallery of modernist art at the American Art Museum and partially replacing lamps in two galleries of the Museum’s Renwick Gallery. This report describes the selection and testing process, technology challenges, perceptions, economics, energy use, and mixed results of using LED replacement lamps in art galleries housing national treasures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplified Space Conditioning in Low-Load Homes: Results from the Fresno, California, Retrofit Unoccupied Test House

In this study, the Building America team, IBACOS, sought to determine cost-effective, energy-efficient solutions for heating and cooling houses. To this end, the team performed field testing in a retrofit unoccupied test house in Fresno, California, to evaluate three air-based heating, ventilation, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. These included a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utilizing geothermal heat for hydrothermal liquefaction of algae

The distribution of utilizable geothermal reservoirs in the US is concentrated in areas of low population density. In order to increase the scale of geothermal operations, we proposed to develop a modular biofuel production facility that directly uses geothermal heat. By transforming geothermal heat to chemical potential energy (rather than electricity), the scale of existing or new geothermal operations can be increased and distributed to areas of higher population density. Simultaneously, the economics of producing biocrude oil is improved significantly where geothermal heat is used, instead of natural gas-fired systems for providing heat and power. In the Phase I project, we demonstrated that it was economically feasible to sustainably produce a biofuel by integrating geothermal heat. It was found that, for the best case scenario at a scale of 10T(biomass)/hr, it was possible to produce a biofuel for $0.26/L, as compared to crude oil at $0.3/L (current selling price). Ultimately this demonstrates that this technology can be economically sustainable when integrated with geothermal heat. We also demonstrated that the addition of modular biofuel-production technologies can be more profitable for a geothermal plant operator. For 1000kg/day scale, it was found that it could be 2.5 times more profitable for a geothermal plant operator to sell bio-oil rather than electricity (with a waste source within 20 miles of the processing facility). Furthermore, as the design of the proposed technology recycles significant heat, requiring between 5% and 20% of the total heat load of the biofuel process to be supplied by the geothermal plant, it is feasible for an operator to initially implement the technology at small scale (i.e. less than 100gal/day) with the plans of scaling up operations in the future. Implementing the technology incrementally may minimize initial the investment and financial risk for the operator. Finally, in the Phase I project, we built and tested a hydrothermal system developed at ARI. We tested three different feedstock types, pure algae feed, algae mixed with manure, and algae with in-situ catalysts (molybdenum trioxide), over a range of temperatures and residence times. In terms of oil products, our results (yield, process times and elemental balance) were similar to what was obtained at PNNL. As such our experiments matched well with the techno-economic design (mass throughput specifications), and will thus well inform the Phase II process design. The experimental data obtained on the hydrothermal treatment of algae indicated that the highest recovery of oil occurred at 250°C. This shows that HTL can be carried out 100°C lower than what is currently considered ‘state of the art’, and thus save significant energy savings. Further, it was found that oil-recovered fractions had lower amounts of nitrogen at lower temperatures, indicating that oil produced at 250°C is of higher quality than if we were to produce fuel at 350°C.

09 BIOMASS FUELS↗

Development of Ultraviolet Curable Binder Technology to Reduce Manufacturing Cost and Improve Performance of Lithium ion Battery Electrodes (Final Report)

Miltec UV International and its partners, Oak Ridge National Laboratory (ORNL) and Argonne National Laboratory (ANL) undertook this project to demonstrate the use of UV curable binder to replace conventional solvent based binders such as PVDF as a means of reducing the manufacturing cost of Lithium ion battery (LIB) electrodes. The project involved an iterative Research and Development (R&D) effort: making coin cells and pouch cells from electrodes made with varying UV chemistries and active materials, followed by testing and analyses, then by adjustments in UV chemistry, mixing, coating, and UV curing to produce layered pouch cells at high processing speeds with performance equal or greater than that of a conventional PVDF cell. The effort focused on cathodes made with UV curable binders and multiple active cathode materials such as NMC, NCA, Sulfur, and LMO and anodes made with LTO. A primary objective of the project is to provide performance data sufficient for Lithium ion battery manufacturers to commit to the first steps of making their own HEV, PHEV and/or EV Lithium ion batteries with a UV process. In addition, the project successfully demonstrated coating and UV curing a cathode layer on top of an existing UV cathode layer to produce a thicker high energy cathode with good porosity and no discontinuity between layers. It also demonstrated the potential advantages of one layer of a power loading with a second layer of an energy loading.

25 ENERGY STORAGE↗

Design Optimization of A generic Fissile Solution for Mo99 production using Electron Beam-based Neutron Generator using MCNP+CFD

Molybdenum-99 ( 99 Mo) is a medical isotope used in 80% of all medical imaging procedures today. However, 99 Mo is not directly administered to patients for imaging; its decay product, technetium-99m ( 99 mTc), is a metastable isotope with a half-life of ~6 hours. Such a short half-life does not allow for production, separation, and application to a patient before decaying further. Therefore, the solution is to produce the precursor to 99 mTc, 99 Mo. 99 Mo has a half-life of 66 hours, long enough to produce the material and send it to the desired location before it fully decays. Under National Nuclear Security Administration’s (NNSA) highly enriched uranium (HEU) minimization mission, the Material Management and Minimization (M3) office leads the Molybdenum-99 (Mo-99) program. A major goal of the Mo-99 program is to develop methods of producing 99 Mo using low enriched uranium (LEU) opposed to the traditionally used HEU domestically in the U.S. Internationally, LEU is the new standard for use in research reactors and isotope production facility. In this study, we introduce a generic fissile solution system for 99 Mo production facility meeting the design requirement of 1) LEU usage as fissile material and 2) subcritical fissile system coupled with a horizontal electron beam (E-beam) accelerator. The focus of this research is to optimize a fissile solution configuration for maximum 99 Mo production yield using MCNP model, and ultimately implement the optimized design with computational fluid dynamics (CFD) model to understand thermal hydraulic behavior and solution convection characteristic. The report consists of two parts: 1) isotope yield calculation and criticality analysis with a wide range of parametric test matrix, and 2) thermal hydraulic analysis for solution mixing and cooling assessment.

60 APPLIED LIFE SCIENCES↗

Results of the Analyses of SMECT Mercury Sample Collected During Mercury Pump (MB1) Functional Check

A pump added to remove mercury from the sump of the Slurry Mix Evaporator Condensate Tank (SMECT) in DWPF was successfully tested in 2020, resulting in a sample of contaminated mercury obtained from the Mercury Purification Process (MPP) cell. The mercury in the sump of the SMECT was present as a result of steam stripping of sludge slurry in the Sludge Receipt and Adjustment Tank (SRAT) at DWPF. A schematic of the MPP system provided by DWPF personnel is shown in Appendix A. DWPF personnel supplied the following detailed description of the Hg sampling: “The sample provided is the result of DWPF extraction of mercury by means of the Mercury Pump-Water Cart. The Mercury Pump extracted the sample from the SMECT mercury sump. The pump uses pressurized water to transfer a small amount of mercury to a leachate bucket located at the Lab Mercury cell. The mercury and water were allowed to be self separated, and mercury was gravity decanted from the leachate bucket.” DWPF personnel indicate that the leachate bucket is equipped with both a top stopcock/drain and a lower/bottom stopcock/drain from which the mercury was decanted or drained out, while the separated water layer remained above the mercury during draining. The DWPF customer requested SRNL to analyze the sample for the following: gross alpha/nonvolatile beta analysis and perform a Toxicity Characteristic Leaching Procedure (TCLP) per the Environmental Protection Agency's Test Methods for Evaluating Solid Waste: Physical/Chemical Methods, SW-846. While the TCLP was preferred, a Total Metals analysis of the eight Resource Conservation and Recovery Act (RCRA) metals was deemed acceptable.2 The analytical data collected on this mercury sample will be used in planning for sample disposition as well to start a profile for future Hg disposition of Hg collected from steam stripping.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Root Pulling Force Across Drought in Maize Reveals Genotype by Environment Interactions and Candidate Genes

High-throughput, field-based characterization of root systems for hundreds of genotypes in thousands of plots is necessary for breeding and identifying loci underlying variation in root traits and their plasticity. We designed a large-scale sampling of root pulling force, the vertical force required to extract the root system from the soil, in a maize diversity panel under differing irrigation levels for two growing seasons. We then characterized the root system architecture of the extracted root crowns. We found consistent patterns of phenotypic plasticity for root pulling force for a subset of genotypes under differential irrigation, suggesting that root plasticity is predictable. Using genome-wide association analysis, we identified 54 SNPs as statistically significant for six independent root pulling force measurements across two irrigation levels and four developmental timepoints. For every significant GWAS SNP for any trait in any treatment and timepoint we conducted post hoc tests for genotype-by-environment interaction, using a mixed model ANOVA. We found that 8 of the 54 SNPs showed significant GxE. Candidate genes underlying variation in root pulling force included those involved in nutrient transport. Although they are often treated separately, variation in the ability of plant roots to sense and respond to variation in environmental resources including water and nutrients may be linked by the genes and pathways underlying this variation. While functional validation of the identified genes is needed, our results expand the current knowledge of root phenotypic plasticity at the whole plant and gene levels, and further elucidate the complex genetic architecture of maize root systems.

Woods, Patrick↗

Existing Whole-House Solutions Case Study: Passive Room-to-Room Air Transfer, Fresno, California

In this project, IBACOS, a U.S. Department of Energy Building America team, assessed a strategy for providing conditioned air to bedrooms when the bedroom doors are closed and measured potential thermal discomfort that occupants may experience when this strategy is used. Builders can use this information to discuss space conditioning options for low-load houses with their clients to determine acceptable comfort levels for occupants in these cost-optimized, energy-efficient houses.

50% BA Benchmark↗

Improved Management of the Technical Interfaces Between the Hanford Tank Farm Operator and the Hanford Waste Treatment Plant - 13383

The Department of Energy (DOE) is constructing the Waste Treatment and Immobilization Plant (WTP) at the Hanford site in Washington to treat and immobilize approximately 114 million gallons of high level radioactive waste (after all retrievals are accomplished). In order for the WTP to be designed and operated successfully, close coordination between the WTP engineering, procurement, and construction contractor, Bechtel National, Inc. and the tank farms operating contractor (TOC), Washington River Protection Solutions, LLC, is necessary. To develop optimal solutions for DOE and for the treatment of the waste, it is important to deal with the fact that two different prime contractors, with somewhat differing contracts, are tasked with retrieving and delivering the waste and for treating and immobilizing that waste. The WTP and the TOC have over the years cooperated to manage the technical interface. To manage what is becoming a much more complicated interface as the WTP design progresses and new technical issues have been identified, an organizational change was made by WTP and TOC in November of 2011. This organizational change created a co-located integrated project team (IPT) to deal with mutual and interface issues. The Technical Organization within the One System IPT includes employees from both TOC and WTP. This team has worked on a variety of technical issues of mutual interest and concern. Technical issues currently being addressed include: - The waste acceptance criteria; - Waste feed delivery and the associated data quality objectives (DQO); - Evaluation of the effects of performing a riser cut on a single shell tank on WTP operations; - The disposition of secondary waste from both TOC and WTP; - The close coordination of the TOC double shell tank mixing and sampling program and the Large Scale Integrated Test (LSIT) program for pulse jet mixers at WTP along with the associated responses to the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 2010-2; - Development of a set of alternatives to the current baseline that involve aspects of direct feed, feed conditioning, and design changes. The One System Technical Organization has served WTP, TOC, and DOE well in managing and resolving issues at the interface. This paper describes the organizational structure used to improve the interface and several examples of technical interface issues that have been successfully addressed by the new organization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flame Flashback Investigations in Hydrogen-Enriched Low Swirl Flames using High-Speed Hydroxyl (OH) Planar Laser-Induced Fluorescence

This study reports flashback mechanism observed in hydrogen-enriched flames stabilized in a low swirl burner (LSB) at atmospheric pressure and temperature conditions. The fundamentals of hydrogen-rich stable flames and spatiotemporal investigation of flashback phenomena were observed experimentally using a high-repetition-rate nanosecond (ns)-duration hydroxyl radical planar laser-induced fluorescence (OH-PLIF) diagnostic. Testing was conducted in an optically accessible pre-mixing section of LSB with inlet pre-mixing velocities from 5 to 10 m/s for methane and hydrogen (50 – 90% by mole) blends. Swirlers with two different turning angles, 26 and 33 degrees and three different perforated plate hole diameters, 1.08, 1.12 and 1.16 mm with measured swirl numbers varying from 0.43 to 0.49 were used. The flashback propensity showed dependence on the proximity of the lifted flame to the burner exit which was dependent on pre-mixer velocity, hydrogen content and equivalence ratio (ER). High-speed OH-PLIF images revealed lifted flames were first observed at low ER condition which is changed to M-shaped flame attached to burner rim with the increase in ER. Then, further increase in ER triggers flame flashback into the nozzle. Flashback occurred when burning occurs in the outer shear layer and the leading flame brush ingresses into the nozzle.

Parajuli, Pradeep↗

High-Speed OH-PLIF Diagnostics of Flame Flashback in Low Swirl Hydrogen-Enriched Flames

This paper reports flashback events observed in hydrogen-enriched flames stabilized in a low swirl burner (LSB) at atmospheric pressure and temperature conditions. The fundamentals of hydrogen-rich stable flames and spatiotemporal investigation of flashback phenomena were observed experimentally using a high-repetition-rate nanosecond (ns)-duration hydroxyl radical planar laser-induced fluorescence (OH-PLIF) diagnostic. Testing was conducted in an optically accessible pre-mixing section of a LSB with inlet pre-mixing velocities ranging from 5 to 10 m/s for methane and hydrogen (50 – 90% by mole) blends. Swirlers with two different turning angles, 26o and 33o, and three different perforated plate hole diameters, 1.08, 1.12 and 1.16 mm, with measured swirl numbers varying from 0.43 to 0.49 were used in this study at atmospheric temperature and pressure inlet conditions. The flashback propensity showed a dependence on the proximity of the lifted flame to the burner exit (termed as lift-off length, L) which was dependent on the pre-mixer velocity (V), hydrogen content (XH2) and equivalence ratio (ϕ) at constant temperature and pressure conditions. High-speed OH-PLIF images revealed lifted flames were first observed at low ϕ/ XH2 condition which then changed to a M-shaped flame attached to burner rim with the increase in ϕ/ XH2. Further increases in ϕ/XH2, depending upon other inlet parameters, triggered flame flashback into the pre-mixing section. Flashback occurred when burning began in the outer shear layer and the leading flame brush propagated into the nozzle. Such spatiotemporally resolved high-speed OH-PLIF imaging provides insights on different stages of flashback in a LSB – flashback initiation, transition of flame propagation from burner exit to the swirler and flashback to flame holding transition. Flame ϕ at flashback showed an expected linearly increasing trend with increasing V and decreasing XH2 and the conclusions drawn aligned well with detailed investigations. For identical inlet conditions, flashback propensity decreased with increasing perforated-plate hole diameter and increasing swirler vane angle.

Parajuli, Pradeep↗

Nonlinear Advection Algorithms Applied to Inter-related Tracers: Errors and Implications for Modeling Aerosol-Cloud Interactions

Monotonicity constraints and gradient preserving flux corrections employed by many advection algorithms used in atmospheric models make these algorithms non-linear. Consequently, any relations among model variables transported separately are not necessarily preserved in such models. These errors cannot be revealed by traditional algorithm testing based on advection of a single tracer. New type of tests are developed and conducted to evaluate the preservation of a sum of several number mixing ratios advected independently of each other, as is the case, for example, in models using bin or sectional representation of aerosol or cloud particle size distribution. The tests show that when three tracers are advected in 1D uniform constant velocity flow, local errors in the sum can be on the order of 10%. When cloud-like interactions are allowed among the tracers, errors in total sum of three mixing ratios can reach up to 30%. Several approaches to eliminate the error are suggested, all based on advecting the sum as a separate variable and then normalizing mixing ratios for individual tracers to match the total sum. A simple scalar normalization preserves the total number mixing ratio and positive definiteness of the variables but the monotonicity constraint for individual tracers is no longer maintained. More involved flux normalization procedures are developed for the flux based advection algorithms to maintain the monotonicity for individual scalars and their sum.

54 ENVIRONMENTAL SCIENCES↗