Search NASA⌕ Search

SEARCH · Search NASA

Results for “Modal Test and Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

SU-E-T-441: Gamma Passing Rates for IMRT QA and VMAT QA

Purpose: This study compares gamma passing rates for a cohort of similar intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) quality assurance (QA) plans to determine the equivalence of the patient specific QA plan delivery. The passing criterion is 90% gamma index with 3% dose difference (DD), 3mm distance-to-agreement (DTA) and a dose threshold of 10%. Methods: Gamma passing results of previously treated IMRT QA plans, delivered to Sun Nuclear MapCheck phantom, and VMAT QA plans, delivered to ScandiDos Delta4 phantom, are organized by anatomical site and treatment machine. Both Varian and Elekta machines are included. Pairs of IMRT and VMAT plans are matched based on site, machine, and PTV volume to ensure similar plan cohorts. A two-tailed t-test analysis of the data with an alpha of 0.05 determines if there exists a statistically significant difference. Power was calculated to detect a difference of 4%; all data sets were strong with above a 0.8 power. Results: The first data set consisting of 20 matched pairs of prostate plans was statistically insignificant (p-value=0.90, Power=0.99). The 14 matched pairs set of head and neck plans has a statistically significant Result (p-value=0.028, Power=0.88). The head and neck IMRT gamma indexes have a mean of 93.1% and range of 82%-100% while the VMAT gamma indexes have a mean of 96.7% and range of 92%-100%. The two combined data sets of matched plans had a statistically insignificant Result (p-value=0.073, Power=0.99). Conclusion: Overall, IMRT and VMAT have equivalent passing rates when comparing the gamma analysis using a passing criterion of 3% DD and 3mm DTA. When separated by site, prostate IMRT and VMAT plans have equivalent passing rates while head and neck plans have a statistically significant variation of passing rates. The passing rates for the two modalities are independent of delivery machine for matched PTV target volumes.

60 APPLIED LIFE SCIENCES↗

Error Localization Examples: Looking for a Needle in a Hay-stack

Finite element models (FEM) are routinely developed and used during fabrication of high dollar-value hardware. NASA as part of the pre-flight certification of launch vehicles routinely conducts vibration and static tests to calibrate models used for flight-risk assessments. As part of the calibration process, certain areas in the model are modified, using engineering judgment and sensitivity analysis, to match the test results. Unfortunately, tools to identify problem areas in the FEM using test data directly are scarce. Over the years, Error Localization Algorithms (ELA) have been proposed with very limited success. Recently, the Analytical Dynamics Model Improvement (ADMI) algorithm, which computes closed-form mass and stiffness corrections to match the test data exactly, have been shown to be effective for error localization. The paper will present several FEM example problems where ELA is used with simulated test data to determine FEM problem areas. For each example, the correct answer is shown along with ELA results. It is shown that the ELA process is able to identify general problem areas in the FEM, which are consistent with known model perturbations. However, in most cases the ELA identified area of improvement is larger than the true answer. Nonetheless, with proper optimization tools, calibration results using the ELA identified areas provide excellent results.

error localization↗

A method of surface marker location optimization for tumor motion estimation in lung stereotactic body radiation therapy

Purpose: Accurately localizing lung tumor localization is essential for high-precision radiation therapy techniques such as stereotactic body radiation therapy (SBRT). Since direct monitoring of tumor motion is not always achievable due to the limitation of imaging modalities for treatment guidance, placement of fiducial markers on the patient’s body surface to act as a surrogate for tumor position prediction is a practical alternative for tracking lung tumor motion during SBRT treatments. In this work, the authors propose an innovative and robust model to solve the multimarker position optimization problem. The model is able to overcome the major drawbacks of the sparse optimization approach (SOA) model. Methods: The principle-component-analysis (PCA) method was employed as the framework to build the authors’ statistical prediction model. The method can be divided into two stages. The first stage is to build the surrogate tumor matrix and calculate its eigenvalues and associated eigenvectors. The second stage is to determine the “best represented” columns of the eigenvector matrix obtained from stage one and subsequently acquire the optimal marker positions as well as numbers. Using 4-dimensional CT (4DCT) and breath hold CT imaging data, the PCA method was compared to the SOA method with respect to calculation time, average prediction accuracy, prediction stability, noise resistance, marker position consistency, and marker distribution. Results: The PCA and SOA methods which were both tested were on all 11 patients for a total of 130 cases including 4DCT and breath-hold CT scenarios. The maximum calculation time for the PCA method was less than 1 s with 64 752 surface points, whereas the average calculation time for the SOA method was over 12 min with 400 surface points. Overall, the tumor center position prediction errors were comparable between the two methods, and all were less than 1.5 mm. However, for the extreme scenarios (breath hold), the prediction errors for the PCA method were not only smaller, but were also more stable than for the SOA method. Results obtained by imposing a series of random noises to the surrogates indicated that the PCA method was much more noise resistant than the SOA method. The marker position consistency tests using various combinations of 4DCT phases to construct the surrogates suggested that the marker position predictions of the PCA method were more consistent than those of the SOA method, in spite of surrogate construction. Marker distribution tests indicated that greater than 80% of the calculated marker positions fell into the high cross correlation and high motion magnitude regions for both of the algorithms. Conclusions: The PCA model is an accurate, efficient, robust, and practical model for solving the multimarker position optimization problem to predict lung tumor motion during SBRT treatments. Due to its generality, PCA model can also be applied to other imaging guidance system whichever using surface motion as the surrogates.

60 APPLIED LIFE SCIENCES↗

Serum Transforming Growth Factor-β1 Change After Neoadjuvant Chemoradiation Therapy Is Associated With Postoperative Pulmonary Complications in Esophageal Cancer Patients Undergoing Combined Modality Therapy

Purpose: Our aim was to investigate the association of clinical factors, dosimetric parameters, and biomarkers with postoperative pulmonary complications (PPCs) in patients with locally advanced esophageal squamous cell carcinoma (ESCC) treated by neoadjuvant concurrent chemoradiation therapy (CCRT) under strict pulmonary dose constraints and esophagectomy. Methods and Materials: We prospectively enrolled 112 patients undergoing trimodality treatment (including radiation therapy [40 Gy], concurrent taxane-/5-fluorouracil-based regimens, and radical esophagectomy) for ESCC. A PPC was defined as pneumonia or acute respiratory distress syndrome within 30 days after surgery. Serum samples were collected before and within 1 month after CCRT. The association of serum biomarkers with PPCs was detected by proximity ligation assay (PLA) and verified by enzyme-linked immunosorbent assay. Associations of clinical factors, lung dosimetric parameters, and biomarkers with PPC were tested statistically. Results: Thirty-three patients (29.5%) had PPCs. None of the dosimetric parameters was associated with PPCs. Preoperative functional vital capacity (FVC) was significantly associated with PPCs (P=.004). Of the 15 PLA-screened biomarkers, posttreatment transforming growth factor-β1 (TGF-β1) was borderline significantly associated with PPCs (P=.087). Patients with PPCs had significantly larger pre-CCRT to post-CCRT decrease in serum TGF-β1 concentration (−11,310 vs −5332 pg/mL, P=.005) and higher pre-CCRT to post-CCRT percent decline in serum TGF-β1 concentration (−37.4% vs −25.0%, P=.009) than patients without PPCs. On multivariate analysis, preoperative FVC (P=.003) and decrease in TGF-β1 >7040 pg/mL (P=.014) were independent factors associated with PPCs. Conclusions: Preoperative FVC and decrease in serum TGF-β1 level after dose-limited CCRT to the lung are associated with the development of PPCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiotherapy Technical Considerations in the Management of Locally Advanced Pancreatic Cancer: American-French Consensus Recommendations

Summary: Pancreatic carcinoma is a leading cause of cancer-related mortality. Approximately 30% of pancreatic cancer patients present with locally advanced, unresectable nonmetastatic disease. For these patients, two therapeutic options exist: systemic chemotherapy or chemoradiotherapy. Within this context, the optimal technique for pancreatic irradiation is not clearly defined. A search to identify relevant studies was undertaken using the Medline database. All Phase III randomized trials evaluating the modalities of radiotherapy in locally advanced pancreatic cancer were included, as were some noncontrolled Phase II and retrospective studies. An expert panel convened with members of the Radiation Therapy Oncology Group and GERCOR cooperative groups to review identified studies and prepare the guidelines. Each member of the working group independently evaluated five endpoints: total dose, target volume definition, radiotherapy planning technique, dose constraints to organs at risk, and quality assurance. Based on this analysis of the literature, we recommend either three-dimensional conformal radiation therapy or intensity-modulated radiation therapy to a total dose of 50 to 54 Gy at 1.8 to 2 Gy per fraction. We propose gross tumor volume identification to be followed by an expansion of 1.5 to 2 cm anteriorly, posteriorly, and laterally, and 2 to 3 cm craniocaudally to generate the planning target volume. The craniocaudal margins can be reduced with the use of respiratory gating. Organs at risk are liver, kidneys, spinal cord, stomach, and small bowel. Stereotactic body radiation therapy should not be used for pancreatic cancer outside of clinical trials. Radiotherapy quality assurance is mandatory in clinical trials. These consensus recommendations are proposed for use in the development of future trials testing new chemotherapy combinations with radiotherapy. Not all of these recommendations will be appropriate for trials testing radiotherapy dose or dose intensity concepts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Techniques for Power System Identification from Measured Data

Time-synchronized measurements provide rich information for estimating a power-system's electromechanical modal properties via advanced signal processing. This information is becoming critical for the improved operational reliability of interconnected grids. A given mode's properties are described by its frequency, damping, and shape. Modal frequencies and damping are useful indicators of power-system stress, usually declining with increased load or reduced grid capacity. Mode shape provides critical information for operational control actions. This project investigated many advanced techniques for power system identification from measured data focusing on mode frequency and damping ratio estimation. Investigators from the three universities coordinated their effort with Pacific Northwest National Laboratory (PNNL). Significant progress was made on developing appropriate techniques for system identification with confidence intervals and testing those techniques on field measured data and through simulation. Experimental data from the western area power system was provided by PNNL and Bonneville Power Administration (BPA) for both ambient conditions and for signal injection tests. Three large-scale tests were conducted for the western area in 2005 and 2006. Measured field PMU (Phasor Measurement Unit) data was provided to the three universities. A 19-machine simulation model was enhanced for testing the system identification algorithms. Extensive simulations were run with this model to test the performance of the algorithms. University of Wyoming researchers participated in four primary activities: (1) Block and adaptive processing techniques for mode estimation from ambient signals and probing signals, (2) confidence interval estimation, (3) probing signal design and injection method analysis, and (4) performance assessment and validation from simulated and field measured data. Subspace based methods have been use to improve previous results from block processing techniques. Bootstrap techniques have been developed to estimate confidence intervals for the electromechanical modes from field measured data. Results were obtained using injected signal data provided by BPA. A new probing signal was designed that puts more strength into the signal for a given maximum peak to peak swing. Further simulations were conducted on a model based on measured data and with the modifications of the 19-machine simulation model. Montana Tech researchers participated in two primary activities: (1) continued development of the 19-machine simulation test system to include a DC line; and (2) extensive simulation analysis of the various system identification algorithms and bootstrap techniques using the 19 machine model. Researchers at the University of Alaska-Fairbanks focused on the development and testing of adaptive filter algorithms for mode estimation using data generated from simulation models and on data provided in collaboration with BPA and PNNL. There efforts consist of pre-processing field data, testing and refining adaptive filter techniques (specifically the Least Mean Squares (LMS), the Adaptive Step-size LMS (ASLMS), and Error Tracking (ET) algorithms). They also improved convergence of the adaptive algorithms by using an initial estimate from block processing AR method to initialize the weight vector for LMS. Extensive testing was performed on simulated data from the 19 machine model. This project was also extensively involved in the WECC (Western Electricity Coordinating Council) system wide tests carried out in 2005 and 2006. These tests involved injecting known probing signals into the western power grid. One of the primary goals of these tests was the reliable estimation of electromechanical mode properties from measured PMU data. Applied to the system were three types of probing inputs: (1) activation of the Chief Joseph Dynamic Brake, (2) mid-level probing at the Pacific DC Intertie (PDCI), and (3) low-level probing on the PDCI. The Chief Joseph Dynamic Brake is a 1400 MW disturbance to the system and is injected for a half of a second. For the mid and low-level probing, the Celilo terminal of the PDCI is modulated with a known probing signal. Similar but less extensive tests were conducted in June of 2000. The low-level probing signals were designed at the University of Wyoming. A number of important design factors are considered. The designed low-level probing signal used in the tests is a multi-sine signal. Its frequency content is focused in the range of the inter-area electromechanical modes. The most frequently used of these low-level multi-sine signals had a period of over two minutes, a root-mean-square (rms) value of 14 MW, and a peak magnitude of 20 MW. Up to 15 cycles of this probing signal were injected into the system resulting in a processing gain of 15. The resulting measured response at points throughout the system was not much larger than the ambient noise present in the measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structural Loading on the QCM/SAW Instrument Aboard the ER-2 Used for Atmospheric Testing

Several experiments have been proposed to capture and evaluate samples of the atmosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) / surface acoustical wave (SAW) instrument installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000-70,000 feet. The primary use of the ER-2 is by NASA for Earth resources to test new sensor systems before being placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above the sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. The purpose of some of the experiments is to extinct data from the atmosphere around the ER-2. For the current CSTEA flight experiment, the housing of the QCM is in a frame that connects to an outer pod that attaches to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM output data is based on the determination of beat frequencies between a pair of oscillators (one coated, the second uncoated, according to the chemical reaction being monitored). A structural analysis of this system can indicate whether potential resonances may exist between the (higher) structural modal frequencies and the beat frequencies. In addition undesirable deformations may result due to maximum expected static or dynamic loads during typical flight conditions. If the deformations are excessive they may adversely affect the accuracy the instrumentation output.

Bainum, Peter M.↗

WE-AB-207B-07: Dose Cloud: Generating “Big Data” for Radiation Therapy Treatment Plan Optimization Research

Purpose: To provide a tool to generate large sets of realistic virtual patient geometries and beamlet doses for treatment optimization research. This tool enables countless studies exploring the fundamental interplay between patient geometry, objective functions, weight selections, and achievable dose distributions for various algorithms and modalities. Methods: Generating realistic virtual patient geometries requires a small set of real patient data. We developed a normalized patient shape model (PSM) which captures organ and target contours in a correspondence-preserving manner. Using PSM-processed data, we perform principal component analysis (PCA) to extract major modes of variation from the population. These PCA modes can be shared without exposing patient information. The modes are re-combined with different weights to produce sets of realistic virtual patient contours. Because virtual patients lack imaging information, we developed a shape-based dose calculation (SBD) relying on the assumption that the region inside the body contour is water. SBD utilizes a 2D fluence-convolved scatter kernel, derived from Monte Carlo simulations, and can compute both full dose for a given set of fluence maps, or produce a dose matrix (dose per fluence pixel) for many modalities. Combining the shape model with SBD provides the data needed for treatment plan optimization research. Results: We used PSM to capture organ and target contours for 96 prostate cases, extracted the first 20 PCA modes, and generated 2048 virtual patient shapes by randomly sampling mode scores. Nearly half of the shapes were thrown out for failing anatomical checks, the remaining 1124 were used in computing dose matrices via SBD and a standard 7-beam protocol. As a proof of concept, and to generate data for later study, we performed fluence map optimization emphasizing PTV coverage. Conclusions: We successfully developed and tested a tool for creating customizable sets of virtual patients suitable for large-scale radiation therapy optimization research.

60 APPLIED LIFE SCIENCES↗

Trabecular Bone Mechanical Properties and Fractal Dimension

Countermeasures for reducing bone loss and muscle atrophy due to extended exposure to the microgravity environment of space are continuing to be developed and improved. An important component of this effort is finite element modeling of the lower extremity and spinal column. These models will permit analysis and evaluation specific to each individual and thereby provide more efficient and effective exercise protocols. Inflight countermeasures and post-flight rehabilitation can then be customized and targeted on a case-by-case basis. Recent Summer Faculty Fellowship participants have focused upon finite element mesh generation, muscle force estimation, and fractal calculations of trabecular bone microstructure. Methods have been developed for generating the three-dimensional geometry of the femur from serial section magnetic resonance images (MRI). The use of MRI as an imaging modality avoids excessive exposure to radiation associated with X-ray based methods. These images can also detect trabecular bone microstructure and architecture. The goal of the current research is to determine the degree to which the fractal dimension of trabecular architecture can be used to predict the mechanical properties of trabecular bone tissue. The elastic modulus and the ultimate strength (or strain) can then be estimated from non-invasive, non-radiating imaging and incorporated into the finite element models to more accurately represent the bone tissue of each individual of interest. Trabecular bone specimens from the proximal tibia are being studied in this first phase of the work. Detailed protocols and procedures have been developed for carrying test specimens through all of the steps of a multi-faceted test program. The test program begins with MRI and X-ray imaging of the whole bones before excising a smaller workpiece from the proximal tibia region. High resolution MRI scans are then made and the piece further cut into slabs (roughly 1 cm thick). The slabs are X-rayed again and also scanned using dual-energy X-ray absorptiometry (DEXA). Cube specimens are then cut from the slabs and tested mechanically in compression. Correlations between mechanical properties and fractal dimension will then be examined to assess and quantify the predictive capability of the fractal calculations.

Hogan, Harry A.↗

Optimized 3D co-registration of ultra-low-field and high-field magnetic resonance images

The prototypes of ultra-low-field (ULF) MRI scanners developed in recent years represent new, innovative, cost-effective and safer systems, which are suitable to be integrated in multi-modal (Magnetoencephalography and MRI) devices. Integrated ULF-MRI and MEG scanners could represent an ideal solution to obtain functional (MEG) and anatomical (ULF MRI) information in the same environment, without errors that may limit source reconstruction accuracy. However, the low resolution and signal-to-noise ratio (SNR) of ULF images, as well as their limited coverage, do not generally allow for the construction of an accurate individual volume conductor model suitable for MEG localization. Thus, for practical usage, a high-field (HF) MRI image is also acquired, and the HF-MRI images are co-registered to the ULF-MRI ones. We address here this issue through an optimized pipeline (SWIM—Sliding WIndow grouping supporting Mutual information). The co-registration is performed by an affine transformation, the parameters of which are estimated using Normalized Mutual Information as the cost function, and Adaptive Simulated Annealing as the minimization algorithm. The sub-voxel resolution of the ULF images is handled by a sliding-window approach applying multiple grouping strategies to down-sample HF MRI to the ULF-MRI resolution. The pipeline has been tested on phantom and real data from different ULF-MRI devices, and comparison with well-known toolboxes for fMRI analysis has been performed. Our pipeline always outperformed the fMRI toolboxes (FSL and SPM). The HF–ULF MRI co-registration obtained by means of our pipeline could lead to an effective integration of ULF MRI with MEG, with the aim of improving localization accuracy, but also to help exploit ULF MRI in tumor imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hazard Detection Software for Lunar Landing

The Autonomous Landing and Hazard Avoidance Technology (ALHAT) Project is developing a system for safe and precise manned lunar landing that involves novel sensors, but also specific algorithms. ALHAT has selected imaging LIDAR (light detection and ranging) as the sensing modality for onboard hazard detection because imaging LIDARs can rapidly generate direct measurements of the lunar surface elevation from high altitude. Then, starting with the LIDAR-based Hazard Detection and Avoidance (HDA) algorithm developed for Mars Landing, JPL has developed a mature set of HDA software for the manned lunar landing problem. Landing hazards exist everywhere on the Moon, and many of the more desirable landing sites are near the most hazardous terrain, so HDA is needed to autonomously and safely land payloads over much of the lunar surface. The HDA requirements used in the ALHAT project are to detect hazards that are 0.3 m tall or higher and slopes that are 5 or greater. Steep slopes, rocks, cliffs, and gullies are all hazards for landing and, by computing the local slope and roughness in an elevation map, all of these hazards can be detected. The algorithm in this innovation is used to measure slope and roughness hazards. In addition to detecting these hazards, the HDA capability also is able to find a safe landing site free of these hazards for a lunar lander with diameter .15 m over most of the lunar surface. This software includes an implementation of the HDA algorithm, software for generating simulated lunar terrain maps for testing, hazard detection performance analysis tools, and associated documentation. The HDA software has been deployed to Langley Research Center and integrated into the POST II Monte Carlo simulation environment. The high-fidelity Monte Carlo simulations determine the required ground spacing between LIDAR samples (ground sample distances) and the noise on the LIDAR range measurement. This simulation has also been used to determine the effect of viewing on hazard detection performance. The software has also been deployed to Johnson Space Center and integrated into the ALHAT real-time Hardware-in-the-Loop testbed.

Huertas, Andres↗

SU-F-J-93: Automated Segmentation of High-Resolution 3D WholeBrain Spectroscopic MRI for Glioblastoma Treatment Planning

Purpose: We report on an automated segmentation algorithm for defining radiation therapy target volumes using spectroscopic MR images (sMRI) acquired at nominal voxel resolution of 100 microliters. Methods: Wholebrain sMRI combining 3D echo-planar spectroscopic imaging, generalized auto-calibrating partially-parallel acquisitions, and elliptical k-space encoding were conducted on 3T MRI scanner with 32-channel head coil array creating images. Metabolite maps generated include choline (Cho), creatine (Cr), and N-acetylaspartate (NAA), as well as Cho/NAA, Cho/Cr, and NAA/Cr ratio maps. Automated segmentation was achieved by concomitantly considering sMRI metabolite maps with standard contrast enhancing (CE) imaging in a pipeline that first uses the water signal for skull stripping. Subsequently, an initial blob of tumor region is identified by searching for regions of FLAIR abnormalities that also display reduced NAA activity using a mean ratio correlation and morphological filters. These regions are used as starting point for a geodesic level-set refinement that adapts the initial blob to the fine details specific to each metabolite. Results: Accuracy of the segmentation model was tested on a cohort of 12 patients that had sMRI datasets acquired pre, mid and post-treatment, providing a broad range of enhancement patterns. Compared to classical imaging, where heterogeneity in the tumor appearance and shape across posed a greater challenge to the algorithm, sMRI’s regions of abnormal activity were easily detected in the sMRI metabolite maps when combining the detail available in the standard imaging with the local enhancement produced by the metabolites. Results can be imported in the treatment planning, leading in general increase in the target volumes (GTV60) when using sMRI+CE MRI compared to the standard CE MRI alone. Conclusion: Integration of automated segmentation of sMRI metabolite maps into planning is feasible and will likely streamline acceptance of this new acquisition modality in clinical practice.

60 APPLIED LIFE SCIENCES↗

Pain Analysis in Patients with Hepatocellular Carcinoma: Irreversible Electroporation versus Radiofrequency Ablation-Initial Observations

To retrospectively compare the postprocedure pain of hepatocellular carcinoma treated with irreversible electroporation (IRE) with radiofrequency ablation (RFA). This Health Insurance Portability and Accountability Act-compliant, institutional review board-approved study compared postprocedure pain in 21 patients (15 men, six women; mean age 61.5 years) who underwent IRE of 29 intrahepatic lesions (mean size 2.20 cm) in 28 IRE sessions with 22 patients (16 men, six women; mean age 60.2 years) who underwent RFA of 27 lesions (mean size 3.38 cm) in 25 RFA sessions. Pain was determined by patient-disclosed scores with an 11-point numerical rating scale and 24 h cumulative hydromorphone use from patient-controlled analgesia pump. Complications were noted. Statistical significance was evaluated by Fisher's exact test, the Chi-square test, and Student's t test. There was no significant difference in the cumulative hydromorphone dose (1.54 mg (IRE) vs. 1.24 mg (RFA); P = 0.52) and in the mean pain score (1.96 (IRE) vs. 2.25 (RFA); P = 0.70). In nine (32.14 %) of 28 IRE sessions and 11 (44.0 %) of 25 RFA sessions, patients reported no pain. Complications occurred in three (10.7 %) of 28 IRE treatments and included pneumothorax (n = 1), pleural effusion (n = 1), and bleeding in the form of hemothorax (n = 1); one (4 %) of 25 RFA treatments included burn. IRE is comparable to RFA in the amount of pain that patients experience and the amount of pain medication self-administered. Both modalities were well tolerated by patients. Prospective, randomized trials are necessary to further evaluate these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Uptake Patterns of Radioactive Iodine and [18F]-Fluorodeoxyglucose (FDG) in Metastatic Differentiated Thyroid Cancers

Background: Metastatic differentiated thyroid cancer (DTC) represents a molecularly heterogeneous group of cancers with varying radioactive iodine (RAI) and [ 18 F]-fluorodeoxyglucose (FDG) uptake patterns potentially correlated with the degree of de-differentiation through the so-called “flip-flop” phenomenon. However, it is unknown if RAI and FDG uptake patterns correlate with molecular status or metastatic site. Materials and Methods: A retrospective analysis of metastatic DTC patients (n = 46) with radioactive 131-iodine whole body scan (WBS) and FDG-PET imaging between 2008 and 2022 was performed. The inclusion criteria included accessible FDG-PET and WBS studies within 1 year of each other. Studies were interpreted by two blinded radiologists for iodine or FDG uptake in extrathyroidal sites including lungs, lymph nodes, and bone. Cases were stratified by BRAF V600E mutation status, histology, and a combination of tumor genotype and histology. The data were analyzed by McNemar’s Chi-square test. Results: Lung metastasis FDG uptake was significantly more common than iodine uptake (WBS: 52%, FDG: 84%, p = 0.04), but no significant differences were found for lymph or bone metastases. Lung metastasis FDG uptake was significantly more prevalent in the papillary pattern sub-cohort (WBS: 37%, FDG: 89%, p = 0.02) than the follicular pattern sub-cohort (WBS: 75%, FDG: 75%, p = 1.00). Similarly, BRAF V600E+ tumors with lung metastases also demonstrated a preponderance of FDG uptake (WBS: 29%, FDG: 93%, p = 0.02) than BRAF V600E- tumors (WBS: 83%, FDG: 83%, p = 1.00) with lung metastases. Papillary histology featured higher FDG uptake in lung metastasis (WBS: 39%, FDG: 89%, p = 0.03) compared with follicular histology (WBS: 69%, FDG: 77%, p = 1.00). Patients with papillary pattern disease, BRAF V600E+ mutation, or papillary histology had reduced agreement between both modalities in uptake at all metastatic sites compared with those with follicular pattern disease, BRAF V600E- mutation, or follicular histology. Low agreement in lymph node uptake was observed in all patients irrespective of molecular status or histology. Conclusions: The pattern of FDG-PET and radioiodine uptake is dependent on molecular status and metastatic site, with those with papillary histology or BRAF V600E+ mutation featuring increased FDG uptake in distant metastasis. Further study with an expanded cohort may identify which patients may benefit from specific imaging modalities to recognize and surveil metastases.

60 APPLIED LIFE SCIENCES↗

The Design of a Remote Sensing Data Acquisition Campaign for Precision Agriculture and Some Early Results

In the 1970s NASA and the Department of Agriculture attempted to use the new Landsat MSS system for agricultural purposes. The program had relatively little success. With the advent of differential GPS, yield monitors on harvest equipment and higher spatial resolution remote sensing systems it seemed likely the situation should be reexamined. Therefore, a campaign of data acquisition involving remote sensing and other modalities with dependent research was assembled and funded by the Space Grant Consortia in Alabama and Georgia. The design of the remote sensing data acquisition was driven by the biology and physics of the crop system and limited by the available sensor platforms. Major parameters included crop stage, spatial resolution, seasonal and daily weather conditions, and which portion of the EM spectrum would actually capture the most discriminating information. Joint visible and Near IR with Thermal IR would permit use of existing indices, such as greenness, as well as phenomena driven by the plant' s evapotranspiration. Spatial resolution in the 2-5 meter range was chosen, avoiding many complexities caused by aliasing crop row spacing at, higher resolutions yet finer than the harvester's tightest recording rate. This dictates use of an airborne system. Use of an airborne system also makes scheduling around weather much simpler than use of satellite data. Active video calibration was recognized as essential if quantitative measures were ever to be obtained or reproduced. The system would also have to have onboard geoOF1 Based on these elements 3 data acquisitions have been flown. Seven flight lines were flown twice in 1998 and 16 lines flown in 1999. Total raw data is several GBytes. All of the data has now been geometrically corrected and some preliminary analysis accomplished. The thermal bands have an extremely high correlation with yield. For one@test case with corn, correlation in excess of 0.86 was obtained from a data acquisition two months prior to harvest! Soil images show significant within field variation in clay, soil brightness and emissivity. Light wind has been found to effect the reflectance and temperature of broad leaf crops, including soybeans, cotton and peanuts. Clearly, this work has already demonstrated some very important results. With continued development of the remote sensing technology there is good reason to believe this research will soon be able to help the individual farmer.

Rickmanl, D.↗

SU-E-J-210: Characterizing Tissue Equivalent Materials for the Development of a Dual MRI-CT Heterogeneous Anthropomorphic Phantom Designed Specifically for MRI Guided Radiotherapy Systems

Purpose: MRI guided radiotherapy (MRIgRT) is an emerging technology which will eventually require a proficient quality auditing system. Due to different principles in which MR and CT acquire images, there is a need for a multi-imaging-modality, end-to-end QA phantom for MRIgRT. The purpose of this study is to identify lung, soft tissue, and tumor equivalent substitutes that share similar human-like CT and MR properties (i.e. Hounsfield units and relaxation times). Methods: Materials of interested such as common CT QA phantom materials, and other proprietary gels/silicones from Polytek, SmoothOn, and CompositeOne were first scanned on a GE 1.5T Signa HDxT MR. Materials that could be seen on both T1-weighted and T2-weighted images were then scanned on a GE Lightspeed RT16 CT simulator and a GE Discovery 750HD CT scanner and their HU values were then measured. The materials with matching HU values of lung (−500 to −700HU), muscle (+40HU) and soft tissue (+100 to +300HU) were further scanned on GE 1.5T Signa HDx to measure their T1 and T2 relaxation times from varying parameters of TI and TE. Results: Materials that could be visualized on T1-weighted and T2-weighted images from a 1.5T MR unit and had an appropriate average CT number, −650, −685, 46,169, and 168 HUs were: compressed cork saturated with water, Polytek Platsil™ Gel-00 combined with mini styrofoam balls, radiotherapy bolus material, SmoothOn Dragon-Skin™ and SmoothOn Ecoflex™, respectively. Conclusion: Post processing analysis is currently being performed to accurately map T1 and T2 values for each material tested. From previous MR visualization and CT examinations it is expected that Dragon-Skin™, Ecoflex™ and bolus will have values consistent with tissue and tumor substitutes. We also expect compressed cork statured with water, and Polytek™-styrofoam combination to have approximate T1 and T2 values suitable for lung-equivalent materials.

60 APPLIED LIFE SCIENCES↗

Lunar and Planetary Science XXXV: Asteroids, Meteors, Comets

Reports included:Long Term Stability of Mars Trojans; Horseshoe Asteroids and Quasi-satellites in Earth-like Orbits; Effect of Roughness on Visible Reflectance Spectra of Planetary Surface; SUBARU Spectroscopy of Asteroid (832) Karin; Determining Time Scale of Space Weathering; Change of Asteroid Reflectance Spectra by Space Weathering: Pulse Laser Irradiation on Meteorite Samples; Reflectance Spectra of CM2 Chondrite Mighei Irradiated with Pulsed Laser and Implications for Low-Albedo Asteroids and Martian Moons; Meteorite Porosities and Densities: A Review of Trends in the Data; Small Craters in the Inner Solar System: Primaries or Secondaries or Both?; Generation of an Ordinary-Chondrite Regolith by Repetitive Impact; Asteroid Modal Mineralogy Using Hapke Mixing Models: Validation with HED Meteorites; Particle Size Effect in X-Ray Fluorescence at a Large Phase Angle: Importance on Elemental Analysis of Asteroid Eros (433); An Investigation into Solar Wind Depletion of Sulfur in Troilite; Photometric Behaviour Dependent on Solar Phase Angle and Physical Characteristics of Binary Near-Earth-Asteroid (65803) 1996 GT; Spectroscopic Observations of Asteroid 4 Vesta from 1.9 to 3.5 micron: Evidence of Hydrated and/or Hydroxylated Minerals; Multi-Wavelength Observations of Asteroid 2100 Ra-Shalom: Visible, Infrared, and Thermal Spectroscopy Results; New Peculiarities of Cometary Outburst Activity; Preliminary Shape Modeling for the Asteroid (25143) Itokawa, AMICA of Hayabusa Mission; Scientific Capability of MINERVA Rover in Hayabusa Asteroid Mission; Characteristics and Current Status of Near Infrared Spectrometer for Hayabusa Mission; Sampling Strategy and Curation Plan of Hayabusa Asteroid Sample Return Mission; Visible/Near-Infrared Spectral Properties of MUSES C Target Asteroid 25143 Itokawa; Calibration of the NEAR XRS Solar Monitor; Modeling Mosaic Degradation of X-Ray Measurements of 433 Eros by NEAR-Shoemaker; Scattered Light Remediation and Recalibration of near Sheomaker s NIS Global Dataaset at 433 Eros; Evaluation of Preparation and Measuring Techniques for Interplanetary Dust Particles for the MIDAS Experiment on Rosetta; Chiron: a Proposed Remote Sensing Prompt Gamma Ray Activation Analysis Instrument for a Nuclear Powered Prometheus Mission;From Present Surveying to Future Prospecting of the Asteroid Belt; Asteroid Physical Properties Probe Microgravity Testing of a Surface Sampling System for Sample Return from Small Solar System Bodies;and Penetrator Coring Apparatus for Cometary Surfaces.

Source record↗

Use of 3.0-T MRI for Stereotactic Radiosurgery Planning for Treatment of Brain Metastases: A Single-Institution Retrospective Review

Purpose: To investigate the efficacy of 3.0-T magnetic resonance imaging (MRI) for detecting brain metastases for stereotactic radiosurgery (SRS) planning. Methods and Materials: All adult patients scheduled for SRS treatment for brain metastases at our institution between October 2005 and January 2008 were eligible for analysis. All patients underwent radiosurgery treatment planning 3.0-T MRI on the day of scheduled radiosurgery and a diagnostic 1.5-T MRI in the days or weeks prior to radiosurgery for comparison. Both scans were interpreted by neuroradiologists who reported their findings in the radiology reports. We performed a retrospective review of the radiology reports to determine the number of brain metastases identified using each MRI system. Results: Of 254 patients scheduled for treatment from October 2005 to January 2008, 138 patients had radiology reports that explicitly described the number of metastases identified on both scans. With a median interval of 17 days (range, 1-82) between scans, the number of metastases detected using 1.5-T MRI system ranged from 1 to 5 and from 1 to 8 using the 3.0 T-MRI system. Twenty-two percent of patients were found to have a greater number of metastases with the 3.0 T-MRI system. The difference in number of metastases detected between the two scans for the entire cohort ranged from 0 to 6. Neither histology (p = 0.52 by chi-sq test) nor time between scans (p = 0.62 by linear regression) were significantly associated with the difference in number of metastases between scans. Conclusions: The 3.0-T MRI system appears to be superior to a 1.5-T MRI system for detecting brain metastases, which may have significant implications in determining the appropriate treatment modality. Our findings suggest the need for a prospectively designed study to further evaluate the use of a 3.0 T-MRI system for stereotactic radiosurgery planning in the treatment of brain metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗