Search NASA⌕ Search

SEARCH · Search NASA

Results for “Next generation sequencing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

655 records · Page 37

NextGen Operations in a Simulated NY Area Airspace

A human-in-the-loop simulation conducted in the Airspace Operations Laboratory (AOL) at NASA Ames Research Center explored the feasibility of a Next Generation Air Transportation System (NextGen) solution to address airspace and airport capacity limitations in and around the New York metropolitan area. A week-long study explored the feasibility of a new Optimal Profile Descent (OPD) arrival into the airspace as well as a novel application of a Terminal Area Precision Scheduling and Spacing (TAPSS) enhancement to the Traffic Management Advisor (TMA) arrival scheduling tool to coordinate high volume arrival traffic to intersecting runways. In the simulation, four en route sector controllers and four terminal radar approach control (TRACON) controllers managed traffic inbound to Newark International Airport's primary runway, 22L, and its intersecting overflow runway, 11. TAPSS was used to generate independent arrival schedules for each runway and a traffic management coordinator participant adjusted the arrival schedule for each runway 11 aircraft to follow one of the 22L aircraft. TAPSS also provided controller-managed spacing tools (slot markers with speed advisories and timelines) to assist the TRACON controllers in managing the arrivals that were descending on OPDs. Results showed that the tools significantly decreased the occurrence of runway violations (potential go-arounds) when compared with a Baseline condition with no tools. Further, the combined use of the tools with the new OPD produced a peak arrival rate of over 65 aircraft per hour using instrument flight rules (IFR), exceeding the current maximum arrival rate at Newark Liberty International Airport (EWR) of 52 per hour under visual flight rules (VFR). Although the participants rated the workload as relatively low and acceptable both with and without the tools, they rated the tools as reducing their workload further. Safety and coordination were rated by most participants as acceptable in both conditions, although the TRACON Runway Coordinator (TRC) rated neither as acceptable in the Baseline condition. Regarding the role of the TRC, the two TRACON controllers handling the 11 arrivals indicated that the TRC was very much needed in the Baseline condition without tools, but not needed in the condition with tools. This indicates that the tools were providing much of the sequencing and spacing information that the TRC had supplied in the Baseline condition.

NextGen↗

Improving Limit Surface Search Algorithms in RAVEN Using Acceleration Schemes: Level II Milestone

The RAVEN code is becoming a comprehensive tool to perform Probabilistic Risk Assessment (PRA); Uncertainty Quantification (UQ) and Propagation; and Verification and Validation (V&V). The RAVEN code is being developed to support the Risk-Informed Safety Margin Characterization (RISMC) pathway by developing an advanced set of methodologies and algorithms for use in advanced risk analysis. The RISMC approach uses system simulator codes applied to stochastic analysis tools. The fundamental idea behind this coupling approach to perturb (by employing sampling strategies) timing and sequencing of events, internal parameters of the system codes (i.e., uncertain parameters of the physics model) and initial conditions to estimate values ranges and associated probabilities of figures of merit of interest for engineering and safety (e.g. core damage probability, etc.). This approach applied to complex systems such as nuclear power plants requires performing a series of computationally expensive simulation runs. The large computational burden is caused by the large set of (uncertain) parameters characterizing those systems. Consequently, exploring the uncertain/parametric domain, with a good level of confidence, is generally not affordable, considering the limited computational resources that are currently available. In addition, the recent tendency to develop newer tools, characterized by higher accuracy and larger computational resources (if compared with the presently used legacy codes, that have been developed decades ago), has made this issue even more compelling. In order to overcome to these limitations, the strategy for the exploration of the uncertain/parametric space needs to use at best the computational resources focusing the computational effort in those regions of the uncertain/parametric space that are “interesting” (e.g., risk-significant regions of the input space) with respect the targeted Figures Of Merit (FOM): for example, the failure of the system, subject of the analysis. These methodologies are named, in the RAVEN environment, adaptive sampling strategies. These methodologies infer system responses from surrogate models constructed from already existing samples (produced using high fidelity simulations) and suggest the most relevant location (coordinate in the input space) of the next sampling point to be explored in the uncertain/parametric domain. When using those methodologies, it is possible to understand features of the system response with a small number of carefully selected samples. This report focuses on the development and improvement of the limit surface search. The limit surface is an important concept in system reliability analysis. Without going into the details, which will be covered later in the report, the limit surface could be briefly described as an hyper-surface in the system uncertainty/parametric space separating the regions leading to a prescribed system outcome. For example, if the uncertainty/parametric space is the one generated by the reactor power level and the duration of the batteries, the system is a nuclear power plant and the system outcome discriminating variable is the clad failure in a station blackout scenario, then the limit surface separates the combinations of reactor power level and battery duration that lead to clad failure from the ones that do not.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Proposal for a Ton Scale Bubble Chamber for Dark Matter Detection

The nature of non-baryonic dark matter is one of the most intriguing questions for particle physics at the start of the 21st century. There is ample evidence for its existence, but almost nothing is known of its properties. WIMPs are a very appealing candidate particle and several experimental campaigns are underway around the world to search for these particles via the nuclear recoils that they should induce. The COUPP series of bubble chambers has played a significant role in the WIMP search. Through a sequence of detectors of increasing size, a number of R&D issues have arisen and been solved, and the technology has now been advanced to the point where the construction of large chambers requires a modest research effort, some development, but mostly just engineering. It is within this context that we propose to build the next COUPP detector - COUPP-500, a ton scale device to be built over the next three years at Fermilab and then deployed deep underground at SNOLAB. The primary advantages of the COUPP approach over other technologies are: (1) The ability to reject electron and gamma backgrounds by arranging the chamber thermodynamics such that these particles do not even trigger the detector. (2) The ability to suppress neutron backgrounds by having the radioactively impure detection elements far from the active volume and by using the self-shielding of a large device and the high granularity to identify multiple bubbles. (3) The ability to build large chambers cheaply and with a choice of target fluids. (4) The ability to increase the size of the chambers without changing the size or complexity of the data acquisition. (5) Sensitivity to spin-dependent and spin-independent WIMP couplings. These key advantages should enable the goal of one background event in a ton-year of exposure to be achieved. The conceptual design of COUPP-500 is scaled from the preceding devices. In many cases all that is needed is a simple scaling up of components previously used. Calibration and R&D are still needed on some aspects of the system. We know we have the ability to distinguish alpha-induced events from nuclear recoils, but we do not yet know whether the combination of material purity and rejection are good enough to run for a year with no alpha background. We also need to have more detailed measurements of the detector threshold and a better understanding of its high gamma rejection. In addition, there are important checks to make on the longevity of the detector components in the hydraulic fluid and on the chemistry of the active fluid. The 2009 PASAG report explicitly supported the construction of the COUPP-500 device in all funding scenarios. The NSF has shown similar enthusiasm. It awarded one of its DUSEL S4 grants to assist in the engineering needed to build COUPP-500. The currently estimated cost of COUPP-500 is $8M, about half the $15M-$20M price tag expected by the PASAG report for a next generation dark matter search experiment. The COUPP-500 device will have a spin independent WIMP-nucleus cross-section sensitivity of 6 x 10{sup -47} cm{sup 2} after a background-free year of running. This device should then provide the benchmark against which all other WIMP searches are measured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

Nozomi Cis-Lunar Phase Orbit Determination

Japan's Institute of Space and Astronautical Science (ISAS) launched Nozomi, its first mission to the planet Mars using the newly developed M-V launch vehicle on July 3, 1998. Scientific objectives of the mission are to study the structure and dynamics of the Martian upper atmosphere and its interaction with the solar wind. Nozomi is a cooperative mission between ISAS and the National Aeronautics and Space Administration (NASA). The NASA contribution includes navigation and tracking services provided by the Jet Propulsion Laboratory (JPL). The spacecraft also serves as an engineering demonstration of basic technology for planetary exploration. One of the new technologies was a unique trajectory, developed by ISAS, which used solar gravitational perturbations at the weak stability boundary as an aid to achieve an Earth-Mars transfer orbit. This trajectory saves approximately 120 m/s of Delta V compared to direct hyperbolic insertion and is considered an enabling technology for the mission. Nozomi was the first spacecraft to employ this trajectory and provided on-orbit validation of the technique. The trajectory was achieved by initially placing the spacecraft in a highly elliptical cis-lunar phasing orbit. Six maneuvers were performed during this period to correct injection errors and target an outbound lunar swingby in September 1998. The gravity assist from the lunar swingby raised apogee to the vicinity of the weak stability boundary. After three more targeting maneuvers, Nozomi performed an inbound lunar swingby followed immediately by a powered Earth swingby in late December 1998. A 420 m/s Trans Mars Insertion (TMI) burn at the final Earth periapsis was intended to place the spacecraft on a heliocentric trajectory leading to Mars orbit insertion in October 1999. Orbit determination for Nozomi is performed in parallel by both ISAS and the Multi-Mission Navigation (MMNAV) group at JPL. This was an advantage for the mission because each group would generate solutions based on data collected from their respective tracking networks. Spacecraft events, such as sequence uplinks and maneuvers, were generally scheduled during passes at the Usuda tracking station in Japan. As a result, maneuver design and reconstruction was derived from MMNAV solutions based on JPL tracking data obtained immediately prior to or following maneuvers. Data was also exchanged between ISAS and MMNAV so orbit determination could be performed on joint data sets in support of critical targeting late in the cis-lunar phase. In this paper, information regarding the MMNAV orbit determination effort for the first six months of the mission is presented. The spacecraft trajectory is characterized first, followed by a discussion of the orbit determination estimation procedure and models. Results from selected orbit solutions are presented and compared against reconstructed trajectories. One area of emphasis in this paper is orbit determination in the vicinity of the weak stability boundary. Precise navigation was necessary to target the second lunar swingby and the powered Earth swingby. Delivery accuracy of 150 m was required for these critical encounters, but a number of factors contributed to the general degradation of orbit determination accuracy. This included the fact that the spacecraft was at apogee, at a range of 1.7 million km and moving at less than I km/sec perpendicular to the line of sight. Nozomi was also close to zero degrees declination where there are known limitations on orbit determination performance. Finally, S-band tracking data was acquired through the Nozomi backup low gain antenna. This antenna is offset from the axis of this spin stabilized spacecraft and superimposed large signatures in the Doppler and range data. These difficulties were overcome by combining long data arcs, spanning several maneuvers, with a high fidelity solar pressure model. The model included a physically accurate representation of the spacecraft structure and a high time resolution orientation model. Observation modeling included the removal of the spin induced Doppler bias, spin signature and per pass correction of range calibration errors applied for data leading up to critical events. As a result, all orbit determination goals were met. A second area of emphasis in this paper is the JPL tracking and orbit determination effort in support of the TMI maneuver. TMI occurred out of contact with ground stations and the JPL Goldstone tracking complex had the first pass following the bum. As a result, MMNAV had the responsibility to make a rapid assessment of the maneuver performance. MMNAV made the determination that a 100 m/s under bum had occurred and promptly informed ISAS via voice lines. ISAS immediately began preparations for a correction maneuver (TMIc), which had to be performed during the next Usuda pass. The near real time assessment by MMNAV provided accurate antenna frequency and pointing updates for the spacecraft acquisition at Usuda and the close coordination between the two agencies enabled the design and successful execution of the TMc maneuver. Propellant consumption during the correction burn dictated that the mission be redesigned. ISAS developed a new plan which adds 3 full solar orbits, two Earth swingbys and one lunar swingby with arrival at Mars in January 2004. The final Mars orbit will still enable the mission to achieve all of its science objectives.

Ryne, Mark↗

Special Considerations for the Removal and Disposal of Micro-Reactor Experiments

Idaho National Laboratory (INL) is preparing to host several microreactor experiments through 2030 and beyond. Two new test beds currently under development will operate as microreactor or nuclear system experiment user facilities. Test bed experiments will be performed in series, with each nuclear experiment installed, operated, and removed before installation of the subsequent experiment. The necessarily brief transition period between experiments introduces unique equipment removal and radioactive waste disposal challenges. This paper evaluates equipment removal and radioactive waste management topics associated with tight sequencing of nuclear experiments and presents some of the solutions and approaches currently planned to meet these special considerations for one such experiment, the Molten Chloride Reactor Experiment (MCRE), slated for operation at INL’s Laboratory for Operation and Testing in the United States (LOTUS). The MCRE project is a collaboration between Southern Company Services, TerraPower, and INL, among others, to provide integral nuclear data that will advance molten salt fast reactor technology. MCRE will be the first critical fast-spectrum circulating fuel system ever operated and the first experiment operated in the LOTUS test bed. The experiment will nominally operate at zero power with planned low power excursions as part of operational planning for MCRE has been to minimize at-power operations to limit fission product formation while still achieving experimental objectives. After the experiment is complete, MCRE will be allowed to radioactively decay for a short period (nominally 90 days) prior to system defueling, flushing, removal, and disposal of all MCRE equipment, readying the test bed for the next nuclear experiment. Equipment removal and radioactive waste disposal have been integral to MCRE project planning since the Cooperative Research and Development Agreement was formalized in 2021. Due to requirements for future use of the test bed, the MCRE system, of necessity, must be removed in a much shorter time frame than typical for historic reactor decommissioning projects at INL. This results in minimal time for radioactive decay, resulting in not only elevated radiation dose rates but also the presence of short-to-medium-lived isotopes not typically encountered in the reactor decommissioning and radioactive waste management space. Additional unique constraints placed on the project include lack of intrinsic remote-operations capabilities in the test bed, space constraints in the test bed once MCRE has been installed, and contamination minimization requirements to return the test bed to as-found conditions to enable future use. This paper discusses planned solutions to these challenges. Approaches for implementing remote or semi-remote technologies in a non-hot cell environment with limited space availability are discussed. The paper also summarizes the systems engineering approach for concept development and design of equipment removal systems, which are being implemented concurrent with the MCRE design phase, providing feedback to system designers to incorporate features enabling efficient and safe equipment removal approaches. The timing of this paper at a relatively early phase of the project is meant to highlight the importance of early planning for nuclear system decommissioning while reactor design is ongoing to allow design feedback on componentry driven from decommissioning system needs. As new, innovative nuclear reactor technologies enter the nuclear market sector, reactor experiments are crucial for providing new integral nuclear data that establish safe operational margins for technology advancement. Microreactor experiments at INL will require safe, effective, and timely decommissioning approaches, which in turn require nuclear systems designed to expedite decommissioning. In addition to the advancement of nuclear reactor technologies, these nuclear experiments provide an opportunity to demonstrate, deploy, and test new removal and disposal capabilities to support the next generation of nuclear reactor technology.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Utilization Profiles of the CCSDS Unified Space Link Protocol (USLP)

The purpose of this paper is to identify the utilization profiles for interfacing the Data Protocol Sublayer using the Unified Space Link Protocols (USLP) (reference 1) with the space link coding procedures as specified in the CCSDS Coding & Synchronization Blue Books (references 2 through 5), used in both telecommand and telemetry applications. This paper describes how the USLP Protocol utilizes the coding and synchronization sublayer to support: a. Direct to Earth (DTE) telemetry links for engineering and science data b. Direct to Earth (DTE) telemetry links for very high rate science data c. Direct from Earth (DFE) command, sequencing and flight software loads d. Space to Space Links (Proximity) utilized by orbiters for data exchange to/from surface bound assets. The CCSDS has divided the functions of the Data Link Layer into two sublayers: the Data Link Protocol Sublayer (DLP-SL) and the Coding and Synchronization Sublayer (CS-SL). The Data Link Protocol Sublayer (DLP-SL) interfaces to the users, accepting the data that is to be transported, on the sending side of the link, and delivering that data on the receiving end. The Transfer Frame is the data unit that is transferred across the Data Link Protocol Sublayer and the Coding and Synchronization Sublayer boundary. The Coding and Synchronization Sublayer (CS-SL) provides the encoding, randomization, and frame synchronization functions that prepares the USLP Transfer Frame for transport across the space link. The CS-SL is divided into 2 processes: 1) The Frame Interface Processes (FIP) performs the interface functions required to prepare the data for delivery to the Coding/Decoding Process (CDP). This process includes prepending a Frame Start Marker to the provided frame, when management has designated that the frame is not to be aligned to the codeblock or when there is no block code used. 2) The Coding/Decoding Process (CDP) performs the forward error correction processes that are used to optimize the performance of the link and minimize the error rate. The CDP creates the symbol stream that is delivered to the Physical Layer. The transfer of the USLP transfer frames across different types of space links is the focus of this paper. The Protocol Data Unit (PDU) that is passed in both directions between the Data Link Protocol Sublayer (DLP-SL) and Coding and Synchronization Sublayer (CS-SL) is the transfer frame. The USLP frame structure provides flexibility that can be constrained by the functions utilized within the CS-SL that prepare the transfer frame for transit. For example, the USLP transfer frame contains a length field that enables the frame to be of variable length but CS-SL under certain conditions may constrain the frame to be fixed in length. This paper describes 5 operational modes available for use by the Data Link Layer to provide data exchange across the USLP space link. These modes are different because different operational requirements apply to vastly different types of space links and thus the communications implementation requirements differ. The environmental issues include the power or energy available, the distance between the end points of the link, the complexity of the equipment available at those end points, the atmospheric conditions and radiometric frequency selection. The CS-SL utilizes different forward error correcting codes supported by specific operational modes to configure the data for transit. This paper describes all of the operational modes in a series of data models which decompose the functionality between the Data Link Protocol Sublayer and the Coding and Synchronization sublayer. The operational modes described are: 1. Uncoded Mode: has been used for short links that contain significant available power to provide an acceptable frame error rate. The frames in this mode can be variable in length and typically use an error detection algorithm (i.e., CRC) to determine if there are errors in the received frame. 2. Convolutional Only Mode: is currently the prime forward error correction coding used for the proximity links. The frames in this mode can be variable in length and typically use an error detection algorithm (i.e., CRC) to determine if there are errors in the received frame. 3. Variable Length Frame Aligned to Variable Length Codeblock (TC): is used for Direct from Earth links were power levels are high and the simple, least complex code i.e., the BCH code is used. This mode has been in use since the early 1970s. The BCH code is a short code and the decoder is easy to implement. 4. Fixed Length Frame Aligned to Fixed Length Codeblock (AOS/TM): was introduced when the concatenated Convolutional and Reed-Solomon Code was formulated to provide significant reduction in link data error rate and the ability to determine if there was an error in the decoded codeblock. The frame is aligned to the codeblock so that there is a one to one relationship of frame errors to codeblock errors without additional error detection coding being added. This mode requires the protocol frames to be the exact size of the message portion of the codeblock. 5. Frames Unaligned to Fixed Length Codeblocks (Currently used for very high rates and space to space links): This mode is currently used for missions that have a very high data rate that can be controlled adaptively as the environment changes and as the next generation operating mode for the proximity link. This mode from a coded data stream point of view is exactly like that described in 4. above, except that the frame need not be aligned to the codeblock. There is no requirement on frame length when using this mode. Thus when using USLP it can be used to support links that require short or long frames. There is also no mandatory requirement that frames cannot be separated by idle data reducing the tight data rate connection requirements between the data link protocol sublayer and the coding & synchronization sublayer. In conclusion, how these operational modes can be put to use in mission operational scenarios is described for Direct from Earth links (DFE), Direct to Earth links (DTE), and Proximity links.

Greenberg, E.↗