Search NASA⌕ Search

SEARCH · Search NASA

Results for “ORIFICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Transcatheter Closure of a Chronic Iatrogenic Arteriovenous Fistula Between the Carotid Artery and the Brachiocephalic Vein with an Amplatzer Duct Occluder in Combination with a Carotid Stent

We report an original method of transcatheter closure of an arteriovenous fistula using the combination of an Amplatzer PDA occluder and a carotid stent. The fistula was between the left carotid artery and the brachiocephalic vein. The patient had significant left-to-right shunt and was highly symptomatic. Due to the large orifice and pseudoaneurysmatic enlargement of the fistula, we had to use a large Amplatzer PDA occluder and the protruding part of the PDA device disk had to be covered with a carotid stent. The fistula was completely closed. The patient stopped having symptoms and, 2 years after the procedure, the effect persists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perigraft Plug Embolization of the Internal Iliac Artery and Implantation of a Bifurcated Stentgraft: One Treatment Option for Insufficient Tubular Stentgraft Repair of a Common Iliac Artery Aneurysm

We report an endovascular technique for the treatment of type Ia endoleak after a plain tubular stentgraft had been implanted for a large common iliac artery aneurysm with an insufficient proximal landing zone and without occlusion of the hypogastric in another hospital. CT follow-up showed an endoleak with continuous sac expansion over 12 months. This was classified as type Ia by means of dynamic contrast-enhanced MRI. Before a bifurcated stentgraft was implanted to relocate the landing zone more proximally, the still perfused ipsilateral hypogastric artery was embolized to prevent a type II endoleak. A guidewire was manipulated alongside the indwelling stentgraft. The internal iliac artery could then be selectively intubated followed by successful plug embolization of the vessel’s orifice despite the stentgraft being in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Adrenal Venous Sampling by Non-experts with Reference to CT Images

PurposeTo establish technical success rates and safety of adrenal venous sampling (AVS) performed by non-experts with reference to CT images.Materials and Methods104 AVS procedures with adrenocorticotropic hormone stimulation were performed for patients with suspected primary aldosteronism. One of three radiology residents with 2nd, 5th, and 5th grade experience undertook the procedure under the guidance of an experienced, board-certified interventional radiologist with reference to contrast-enhanced CT images obtained in 102 cases. Successful catheterization of the adrenal veins was assessed using three criteria: an adrenal venous cortisol concentration of more than 200 μg/dL (criterion A); an adrenal vein/inferior vena cava cortisol ratio of more than 5:1 (criterion B); and an adrenal vein/inferior vena cava cortisol ratio of more than 10:1 (criterion C).ResultsThe operators were aware of the anatomy of the left adrenal veins in 102 cases (98 %) and of the right adrenal veins in 99 cases (95 %) prior to the procedure. CT identified the correct position of the right adrenal vein orifice in 82 of 99 cases (83 %). The overall technical success rates for AVS from the right adrenal vein according to criteria A, B, and C, were 96, 96, and 94 %, respectively. Those for the left adrenal vein were 97, 98, and 94 %, respectively. No significant differences in success rates were observed between the operators (p = 0.922–0.984). No major complications, including adrenal vein rupture, were observed.ConclusionsWhen CT images are used to guide AVS, the procedure can be performed successfully and safely even by non-experts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Occluded Carbon Dioxide Gas Angiography for Internal Iliac Arteriography and Intervention

IntroductionThe usefulness of carbon dioxide (CO{sub 2}) gas digital subtraction angiography (DSA) has been reported for patients with renal insufficiency and allergy to iodinated contrast agents. However, CO{sub 2} gas cannot replace the iodinated contrast agent in all cases owing to some disadvantages. We describe balloon-occluded CO{sub 2} DSA (B-CO{sub 2} DSA) as an improved CO{sub 2} DSA procedure for interventions in the internal iliac artery (IIA) region and compare the quality of images obtained using conventional CO{sub 2} DSA and B-CO{sub 2} DSA.Materials and MethodsB-CO{sub 2} DSA-guided embolization was performed for one case of genital bleeding with an acute anaphylactic reaction to the iodinated contrast agent and for three cases of type II endoleaks after endovascular abdominal aortic aneurysm repair with renal dysfunction. A 9-mm occlusion balloon catheter was placed just after the orifice of the IIA. Then, 10–15 ml of CO{sub 2} gas was injected manually via the catheter with and without balloon occlusion. The quality of sequential digital subtraction angiograms was analyzed based on a scoring criterion.ResultsIn all four cases, image quality was improved with B-CO{sub 2} DSA; the poor quality of images without balloon occlusion was because of reflux of the CO{sub 2} gas.ConclusionsB-CO{sub 2} DSA improves the image quality of CO{sub 2} DSA in the IIA region and is useful for vascular intervention. Level of Evidence: Level IV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of the external and internal flow structure of an aerated-liquid injector using X-ray radiography and fluorescence

In the present study, the internal flowfield of aerated-liquid fuel injectors is examined through x-ray radiography and x-ray fluorescence. An inside-out injector, consisting of a perforated aerating tube within an annular liquid stream, sprays into a quiescent environment at a fixed mass flow rate of water and nitrogen gas. The liquid is doped with bromine (in the form of NaBr) to create an x-ray fluorescence signal. This allows for reasonable absorption and fluorescence signals, and one or both diagnostics can be used to track the liquid distribution. The injector housing is fabricated from beryllium (Be), which allows the internal flowfield to be examined (as Be has relatively low x-ray attenuation coefficient). Two injector geometries are compared, illustrating the effects of aerating orifice size and location on the flow evolution. Time-averaged equivalent pathlength (EPL) and line-of-sight averaged density ρ(y) reveal the formation of the two-phase mixture, showing that the liquid film thickness along the injector walls is a function of the aerating tube geometry, though only upstream of the nozzle. These differences in gas and liquid distribution (between injectors with different aerating tube designs) are suppressed as the mixture traverses the nozzle contraction. The averaged liquid velocity (computed from the density and liquid mass flow rate) reveal a similar trend. This suggests that at least for the current configurations, the plume width, liquid mass distribution, and averaged liquid velocity for the time-averaged external spray are insensitive to the aerating tube geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revealing pMDI Spray Initial Conditions: Flashing, Atomisation and the Effect of Ethanol

Sprays from pressurised metered-dose inhalers are produced by a transient discharge of a multiphase mixture. Small length and short time scales have made the investigation of the governing processes difficult. Consequently, a deep understanding of the physical processes that govern atomisation and drug particle formation has been elusive. X-ray phase contrast imaging and quantitative radiography were used to reveal the internal flow structure and measure the time-variant nozzle exit mass density of 50 µL metered sprays of HFA134a, with and without ethanol cosolvent. Internal flow patterns were imaged at a magnification of 194 pixels/mm and 7759 frames per second with 150 ps temporal resolution. Spray projected mass was measured with temporal resolution of 1 ms and spatial resolution 6 µm × 5 µm. The flow upstream of the nozzle comprised large volumes of vapour at all times throughout the injection. The inclusion of ethanol prevented bubble coalescence, altering the internal flow structure and discharge. Radiography measurements confirmed that the nozzle exit area is dominantly occupied by vapour, with a peak liquid volume fraction of 13%. Vapour generation in pMDIs occurs upstream of the sump, and the dominant volume component in the nozzle exit orifice is vapour at all times in the injection. Furthermore, the flow in ethanol-containing pMDIs has a bubbly structure resulting in a comparatively stable discharge, whereas the binary structure of propellant-only flows results in unsteady discharge and the production of unrespirable liquid masses.

42 ENGINEERING↗

Picoelectrospray Ionization Mass Spectrometry Using Narrow-bore Chemically Etched Emitters

Electrospray ionization mass spectrometry (ESI-MS) at flow rates below ~10 nL/min has been only sporadically explored due to difficulty in reproducibly fabricating emitters that can operate at lower flow rates. Here we demonstrate narrow orifice chemically etched emitters for stable electrospray at flow rates as low as 400 pL/min. Depending on the analyte concentration, we observe two types of MS signal response as a function of flow rate. At low concentrations, an optimum flow rate is observed slightly above 1 nL/min, while the signal decreases monotonically with decreasing flow rates at higher concentrations. In spite of lower MS signal, the ion utilization efficiency increases exponentially with decreasing flow rate in all cases. No unimolecular response was observed within this flow rate range during the analysis of an equimolar mixture of peptides, indicating that ionization efficiency is an analyte-dependent characteristic in given experimental conditions. While little to no gain in signal-to-noise was achieved at ultralow flow rates for concentration-limited analyses, experiments consuming the same amount of analyte suggest that mass-limited analyses will benefit strongly from the use of low flow rates and avoiding unnecessary sample dilution. By operating under optimal conditions, consumption of just 500 zmol of sample yielded signal-to-noise ratios ~10 for some peptides. These findings have important implications for the analysis of trace biological samples.

Environmental Molecular Sciences Laboratory↗

Influence of Ionization Source Conditions on the Gas-Phase Protomer Distribution of Anilinium and Related Cations

The gas-phase-ion generation technique and specific ion-source settings of a mass spectrometer influence heavily the protonation processes of molecules and the abundance ratio of the generated protomers. Hitherto that has been attributed primarily to the nature of the solvent and the pH. By utilizing electrospray ionization and ion-mobility mass spectrometry (IM-MS), we demonstrate, even in the seemingly trivial case of protonated aniline, that the protomer ratio strongly depends on the source conditions. Under low in-source ion activation, nearly 100% of the N-protomer of aniline is produced, and it can be subsequently converted to the C-protomer by collisional activation effected by increasing the electrical potential difference between the entrance and exit orifices of the first vacuum region. This activation and transformation process takes place even before the ion is mass-selected and subjected to IM separation. Despite the apparent simplicity of the problem, the preferred protonation site of aniline in the gas phase—the amino group or the aromatic ring—has been a topic of controversy. Our results not only provide unambiguous evidence that ring- and nitrogen-protonated aniline can coexist and be interconverted in the gas phase, but also that the ratio of the protomers depends on the internal energy of the original ion. There are many dynamic ion-transformation and fragmentation processes that take place in the different physical compartments of a Synapt G2 HDMS instrument. Such processes can dramatically change the very identity even of small ions, and therefore should be taken into account when interpreting product-ion mass spectra. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiple simultaneous faults’ impacts on air-conditioner behavior and performance of a charge diagnostic method

Although there have been several studies that have focused on the effects of faults on the performance and on the characteristic features that could be used to detect faults, almost none of the research has studied the effects of multiple simultaneous faults. Existing fault detection and diagnosis approaches that have been developed based on single faults may struggle with simultaneous faults. Here, this paper is part of a series that present a methodology and comprehensive measurement data from a battery of laboratory tests on an air-conditioner with combinations of common faults (refrigerant charge, evaporator airflow, non-condensable gas, and liquid line restrictions) imposed, to show how the indicator variables and overall performance are impacted. The system has a microtube condenser and a fixed-orifice (FXO) expansion device, which are found to affect the features’ fault sensitivity. This experiment is the first to test these combined faults in an FXO-equipped system, so comparisons are made to a previously studied thermostatic expansion valve-equipped system. Finally, a promising charge diagnostic technology is assessed, to see how it is impacted by other faults. The faults reduced capacity by up to 42%, and efficiency by up to 39%. The charge diagnostic performed well, even with multiple faults present.

42 ENGINEERING↗

Toward local core outlet temperature monitoring in gas-cooled nuclear reactors using distributed fiber-optic temperature sensors

Gas-cooled nuclear reactors operate at temperatures up to 950 °C with significant spatial variations in power generation and coolant flow through hundreds of parallel flow channels, resulting in complex mixing at the core outlet. The high temperatures and complex mixing can damage downstream components, challenge reactor calorimetry for power determination, and result in significant conservatism in calculated peak fuel temperatures, which ultimately limits the total power output. Directly measuring each gas stream individually is unrealistic using single point thermocouples, requiring more robust sensing techniques. Fiber-optic sensors are resilient to high temperatures (up to 1,000 °C) and radiation damage. Moreover, distributed measurements can be made along the length of one fiber, making them potential candidates for monitoring local core outlet temperatures to improve core calorimetry and identify hot channels. Here, to the authors’ knowledge, this manuscript is the first to report spatially distributed fiber optic temperature measurements to quantify mixing at the outlet of a relevant orifice plate under prototypic temperature and flow regimes to assess the feasibility of using fiber-optic sensors for distributed measurements of coolant temperature in gas-cooled reactors. A single optical fiber captured dynamic changes in local temperatures, whereas the mixed outlet temperature exhibited a muted response and could not identify which channels were responsible for the change in the mixed outlet temperature. The discussion focuses on potential challenges for deploying distributed optical fibers in gas-cooled reactors, including the effects of vibrations, radiation-induced signal attenuation and drift, and routing of the fiber while minimizing flow obstructions.

42 ENGINEERING↗

Numerical investigation of equivalence ratio effects on Flex-Fuel mixing controlled combustion enabled by prechamber ignition

There is interest in adapting renewable and low-carbon intensity fuels to heavy-duty engines to help displace criteria and greenhouse gas emissions associated with diesel combustion. Low-carbon fuels have inherently low cetane numbers and thus pose a significant challenge when considering direct substitution in diesel combustion systems. Use of an actively fueled prechamber as an ignition source to initiate mixing-controlled combustion (PC-MCC) of low-cetane fuels is becoming an attractive combustion mode to alleviate the identified reactivity deficit. This work focuses on the utilization of an active prechamber to facilitate diesel-like combustion of bioethanol-gasoline fuel blends in a heavy-duty engine. Recent results in this emerging technology suggest that ignition quality is uniquely coupled to prechamber equivalence ratio. In this numerical study, the fundamental implications of prechamber equivalence ratio on the ignition performance of direct injected fuels ranging from E10 to E100 are investigated using CONVERGE. Parametric studies of the prechamber operating strategy were assessed at diesel-like conditions to characterize the performance trends relative to a diesel baseline at the same boundary conditions. Simulation results indicate that PC-MCC is flex-fuel capable and achieves diesel-like ignition qualities and combustion processes for all fuels considered under stoichiometric and rich prechamber conditions. To characterize the equivalence ratio trends observed, a novel inflow boundary modeling technique was utilized to prescribe turbulent jets in place of the prechamber where selective speciation of the jet composition was conducted to isolate the ignition contributions of radical and reacting species in lean, stoichiometric, and rich jets. The inflow boundary modeling suggests that excess fuel and combustion intermediates present in jets produced from stratified and fuel-rich prechamber operation promotes higher jet temperatures and as such are superior ignition sources. Relative to a lean prechamber jet, the peak temperature of a reacting jet from a rich prechamber was up to 600 K hotter at fixed distances from the orifice exit. Furthermore, radicals also demonstrated an influence on the ignition process, but the combustion mode was identified to be thermally dominant.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluating consumer 3D printing nozzles as a low cost alternative for mesophase pitch-derived carbon fiber production

Synthetic fibers, such as Kevlar fibers, SiC fibers, and carbon fibers, are essential components for constructing high performance structures. Whether for engineering, sports, energy storage (batteries and supercapacitors), or aerospace applications, fiber microstructure plays a critical role in fiber properties and functionalities. However, studying fiber nozzle configurations and spinning parameters to achieve the desired microstructure remains challenging, costly, and time consuming. Here, mesophase pitch-derived fibers were used as an example to demonstrate that low cost, commercially available 3D printer nozzles can “print” fibers. Four different nozzles were used to “print” fibers and the effects of their features on fiber properties were observed and compared to other lab spun and commercial pitch- derived CF. A longer orifice length resulted in higher modulus fiber whereas a larger draw-down ratio yielded a stronger fiber. Furthermore, the findings provide a new opportunity for 3D printer hardware application and open up opportunities for developing low-cost fibers.

36 MATERIALS SCIENCE↗

One-dimensional turbulence modeling of a turbulent counterflow flame with comparison to DNS

The one-dimensional turbulence (ODT) model is applied to a reactant-to-product counterflow configuration and results are compared with DNS data. The model employed herein solves conservation equations for momentum, energy, and species on a one dimensional (1D) domain corresponding to the line spanning the domain between nozzle orifice centers. The effects of turbulent mixing are modeled via a stochastic process, while the Kolmogorov and reactive length and time scales are explicitly resolved and a detailed chemical kinetic mechanism is used. Comparisons between model and DNS results for spatial mean and root-meansquare (RMS) velocity, temperature, and major and minor species profiles are shown. The ODT approach shows qualitatively and quantitatively reasonable agreement with the DNS data. Scatter plots and statistics conditioned on temperature are also compared for heat release rate and all species. ODT is able to capture the range of results depicted by DNS. However, conditional statistics show signs of underignition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring the soot onset temperature in high-pressure n-dodecane spray pyrolysis

In this paper, soot formation in pyrolyzing sprays of n-dodecane is visualized and quantified in a high-pressure, high-temperature, constant-volume spray chamber at 38 bar, 76 bar, and 114 bar. Sprays of n-dodecane are injected at 500 bar from a single-hole, 186-µm orifice diameter fuel injector. We quantify the temporal evolution of the soot optical thickness and the total soot mass formed in the pyrolyzing sprays using a high-speed extinction imaging diagnostic. The vessel ambient temperature and pressure are varied independently to identify the soot onset temperature for n-dodecane pyrolysis. Linear extrapolation of the maximum soot formation rates as a function of ambient temperature reveals a soot onset temperature near 1450 K. Finally, the onset temperature determined here for n-dodecane is within 50 K of those previously measured along the centerline of atmospheric pressure coflow diffusion flames for smaller alkane fuels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dielectric-barrier-discharge plasma-assisted hydrogen diffusion flame. Part 1: Temperature, oxygen, and fuel measurements by one-dimensional fs/ps rotational CARS imaging

One-dimensional hybrid fs/ps CARS imaging provides single-laser-shot measurements of temperature, oxygen, and hydrogen in a plasma-assisted hydrogen diffusion flame. The coaxial dielectric-barrier-discharge burner collapses the Re ~50 hydrogen diffusion flame to within ~5 mm of the burner surface at an applied AC potential of 8.75 kV at 18 kHz, coinciding nicely with the full spatial extent of the 1D CARS measurements. Translating the burner through the measurement volume allowed for measurements at numerous radial locations in increments of 1 mm with a resolution of 140 µm × 30 µm × 600 µm, sufficient to resolve spatial gradients in this unsteady flame. Longer probe delays, required for improved dynamic range in regions of high temperature fluctuations, proved difficult to model as a result of a nontrivial decay in the O 2 Raman coherence arising from complexities associated with the triplet ground electronic state of the O 2 molecule. Oxygen linewidths were treated empirically using the observed O 2 coherence decay in spectra acquired from the product gases of lean, near-adiabatic H 2 /air flames stabilized on a Hencken flat-flame burner. While still leading to errors up to 10% at worst, the empirically determined Raman linewidth factors eliminated any systematic error in the O 2 /N 2 measurements with probe delay. Temperature measurements in the Hencken Burner flames proved to be insensitive to probe pulse delay, providing robust thermometry. Here, demonstration of this technique in both the canonical Hencken burner flames and a new DBD burner validates its effectiveness in producing multiple spatially resolved measurements in combustion environments. Measurements in the DBD burner revealed an unsteady, counterflow flattened flame structure near the fuel orifice which became unsteady as the reaction zone curves towards the surface for larger radial positions. Lastly, fluctuations in the fuel concentration were largest at the source, as the large, plasma-generated, unsteady external toroidal vortex that dominates the transport in this flame provides enhanced ventilation of the flame surface in close proximity to the fuel tube.

42 ENGINEERING↗

Machine learning-assisted early ignition prediction in a complex flow

Machine learning methods are used to improve the efficiency by which turbulence-resolved simulations predict whether a hydrogen jet in air crossflow will successfully ignite. The flush-mounted jet issues perpendicularly from the wall of a low-speed wind tunnel into a turbulent boundary layer wherein a laser-induced optical breakdown (LIB) hotspot is deposited. A detailed hydrogen chemical mechanism is used to model the radicals and any subsequent chemical reactions. A dielectric-barrier discharge actuator generates body forces and hydrogen radicals near the jet orifice. Here we focus on the success or not of the ignition based on LIB location. A challenge is that definitive determination of this requires long simulations, up to 440 µs after the LIB deposition. This is particularly expensive since multiple simulations are required to find the threshold. To reduce the computational effort, three short-time (91 µs) criteria are proposed, evaluated, and compared: a constructed criterion based on detailed observations of radicals near the stoichiometric surface and two machine learning approaches, each trained on 38 realizations. The constructed criterion provides a low-cost estimate of the ignition boundary that is unambiguous in 45 of the 50 training and test trials, so only 10% of them would need to be simulated longer. The trained neural networks correctly predict outcomes in all cases evaluated, with the more automated procedure—a convolutional neural network (CNN) trained on two-dimensional images—providing the most definitive outcome prediction. From the CNN, a sensitivity analysis is used to determine which kernel features from the two-dimensional input data, as defined by intermediate-layer network weights, are important for identifying ignition.

42 ENGINEERING↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗