Search NASA⌕ Search

SEARCH · Search NASA

Results for “Observational methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Statistical properties of filaments in the cosmic web

ABSTRACT In the context of the cosmological and constrained Exploring the Local Universe with the reConstructed Initial Density field (ELUCID) simulation, this study explores the statistical characteristics of filaments within the cosmic web, focussing on aspects such as the distribution of filament lengths and their radial density profiles. Using the classification of the cosmic web environment through the Hessian matrix of the density field, our primary focus is on how cosmic structures react to the two variables $R_{\rm s}$ and $\lambda _{\rm th}$. The findings show that the volume fractions of knots, filaments, sheets, and voids are highly influenced by the threshold parameter $\lambda _{\rm th}$, with only a slight influence from the smoothing length $R_{\rm s}$. The central axis of the cylindrical filament is pinpointed using the medial-axis thinning algorithm of the COsmic Web Skeleton (COWS) method. It is observed that median filament lengths tend to increase as the smoothing lengths increase. Analysis of filament length functions at different values of $R_{\rm s}$ indicates a reduction in shorter filaments and an increase in longer filaments as $R_{\rm s}$ increases, peaking around $2.5R_{\rm s}$. The study also shows that the radial density profiles of filaments are markedly affected by the parameters $R_{\rm s}$ and $\lambda _{\rm th}$, showing a valley at approximately $2R_{\rm s}$, with increases in the threshold leading to higher amplitudes of the density profile. Moreover, shorter filaments tend to have denser profiles than their longer counterparts.

Zhang, Youcai (ORCID:0000000319674091)↗

RosettaBackrub--a web server for flexible backbone protein structure modeling and design

The Rosetta-Backrub server (http://kortemmelab .ucsf.edu/backrub) implements the Backrub method, derived from observations of alternative conformations in high-resolution protein crystal structures, for flexible backbone protein modeling. Backrub modeling is applied to three related applications using the Rosetta program for structure prediction and design: (I) modeling of structures of point mutations, (II) generating protein conformational ensembles and designing sequences consistent with these conformations and (III) predicting tolerated sequences at protein–protein interfaces. The three protocols have been validated on experimental data. Starting from a user-provided single input protein structure in PDB format, the server generates near-native conformational ensembles. The predicted conformations and sequences can be used for different applications, such as to guide mutagenesis experiments, for ensemble-docking approaches or to generate sequence libraries for protein design.

59 BASIC BIOLOGICAL SCIENCES↗

Ab initio electronic density in solids by many-body plane-wave auxiliary-field quantum Monte Carlo calculations

We present accurate many-body results of the electronic densities in several solid materials, including Si, NaCl, and Cu. These results are obtained using the ab initio auxiliary-field quantum Monte Carlo (AFQMC) method working in a plane-wave basis with norm-conserving, multiple-projector pseudopotentials. AFQMC has been shown to be an excellent many-body total energy method. Computation of observables and correlation functions other than the ground-state energy requires back-propagation, whose adaption and implementation in the plane-wave basis AFQMC framework are discussed in the present paper. This development allows us to compute correlation functions, electronic densities, and interatomic forces, paving the way for geometry optimizations and calculations of thermodynamic properties in solids. Finite supercell size effects are considerably more subtle in the many-body framework than in independent-electron calculations. We analyze the convergence of the electronic density, and obtain best estimates for the thermodynamic limit. The densities from several typical density functionals are benchmarked against our near-exact results. The electronic densities we obtained can also be used to help construct improved density functionals.

36 MATERIALS SCIENCE↗

All-sky search for periodic gravitational waves in LIGO S4 data

We report on an all-sky search with the LIGO detectors for periodic gravitational waves in the frequency range 50-1000 Hz and with the frequency's time derivative in the range -1x10{sup -8} Hz s{sup -1} to zero. Data from the fourth LIGO science run (S4) have been used in this search. Three different semicoherent methods of transforming and summing strain power from short Fourier transforms (SFTs) of the calibrated data have been used. The first, known as StackSlide, averages normalized power from each SFT. A 'weighted Hough' scheme is also developed and used, which also allows for a multi-interferometer search. The third method, known as PowerFlux, is a variant of the StackSlide method in which the power is weighted before summing. In both the weighted Hough and PowerFlux methods, the weights are chosen according to the noise and detector antenna-pattern to maximize the signal-to-noise ratio. The respective advantages and disadvantages of these methods are discussed. Observing no evidence of periodic gravitational radiation, we report upper limits; we interpret these as limits on this radiation from isolated rotating neutron stars. The best population-based upper limit with 95% confidence on the gravitational-wave strain amplitude, found for simulated sources distributed isotropically across the sky and with isotropically distributed spin axes, is 4.28x10{sup -24} (near 140 Hz). Strict upper limits are also obtained for small patches on the sky for best-case and worst-case inclinations of the spin axes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bounding Lorentz violation at particle colliders by tracking the motion of charged particles

In the presence of Lorentz violation, the motion of a charged particle in a magnetic field is distorted. By measuring the eccentricities of particles' elliptical orbits and studying how those eccentricities vary with the absolute orientation of the laboratory, it is possible to constrain the Lorentz-violating c{sub JK} parameters. For each observed species, this method can provide constraints on four linear combinations of coefficients for which, in some species, there are presently no two-sided bounds.

43 PARTICLE ACCELERATORS↗

Charge Redistribution from Anomalous Magnetovorticity Coupling

Here, we investigate novel transport phenomena in a chiral fluid originated from an interplay between a vorticity and strong magnetic field, which induces a redistribution of vector charges in the system and an axial current along the magnetic field. The corresponding transport coefficients are obtained from an energy-shift argument for the chiral fermions in the lowest Landau level due to a spin-vorticity coupling and also from diagrammatic computations on the basis of the linear response theory. Based on consistent results from both methods, we also observe that the transport coefficients are proportional to the anomaly coefficient and are independent of temperature and chemical potential. Finally, we speculate that these transport phenomena are connected to quantum anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dissecting Reactor Antineutrino Flux Calculations

Current predictions for the antineutrino yield and spectra from a nuclear reactor rely on the experimental electron spectra from 235 U , 239 Pu , 241 Pu and a numerical method to convert these aggregate electron spectra into their corresponding antineutrino ones. In our present work we investigate quantitatively some of the basic assumptions and approximations used in the conversion method, studying first the compatibility between two recent approaches for calculating electron and antineutrino spectra. We then explore different possibilities for the disagreement between the measured Daya Bay and the Huber-Mueller antineutrino spectra, including the 238 U contribution as well as the effective charge and the allowed shape assumption used in the conversion method. Here, we observe that including a shape correction of about + 6 % MeV - 1 in conversion calculations can better describe the Daya Bay spectrum. Because of a lack of experimental data, this correction cannot be ruled out, concluding that in order to confirm the existence of the reactor neutrino anomaly, or even quantify it, precisely measured electron spectra for about 50 relevant fission products are needed. With the advent of new rare ion facilities, the measurement of shape factors for these nuclides, for many of which precise beta intensity data from TAGS experiments already exist, would be highly desirable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Complementarity-based complementarity: The choice of mutually unbiased observables shapes quantum uncertainty relations

Quantum uncertainty relations impose fundamental limits on the joint knowledge that can be acquired from complementary observables: Perfect knowledge of a quantum state in one basis implies maximal indetermination in all other mutually unbiased bases (MUBs). Uncertainty relations derived from joint properties of the MUBs are generally assumed to be uniform, irrespective of the specific observables chosen within a set. In this work, we demonstrate instead that the uncertainty relations can depend on the choice of observables. Through both experimental observation and numerical methods, we show that selecting different sets of three MUBs in a five-dimensional quantum system results in distinct uncertainty bounds, i.e., in varying degrees of complementarity, in terms of both entropy and variance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Estimation of the Water Table Position in Unconfined Aquifers with MODFLOW 6

Abstract The numerical estimation of the position of the water table in unconfined aquifers is important for many practical applications. Its determination through observations or analytical methods is restricted to a few cases. Therefore, it is often estimated through numerical simulations, which may be affected by numerical artifacts and/or poor stability. We use MODFLOW to estimate the position of the water table for a seemingly simple example problem and demonstrate difficulties that can be faced when performing this kind of numerical simulation. We explain the causes for the numerical challenges that originate from the properties of the mathematical equations that must be solved. Based on the results of more than 600 steady‐state simulations, we show how the stability of the numerical solution can be affected by the values of physical parameters that define the problem (e.g., recharge rate, anisotropy ratio, and other parameters that control the numerical algorithm such as settings of the linear and nonlinear solution methods). Finally, we comment on some best practices to apply numerical simulations to estimate the water table position.

Geology↗

Mammographic compression after breast conserving therapy: Controlling pressure instead of force

Purpose: X-ray mammography is the primary tool for early detection of breast cancer and for follow-up after breast conserving therapy (BCT). BCT-treated breasts are smaller, less elastic, and more sensitive to pain. Instead of the current force-controlled approach of applying the same force to each breast, pressure-controlled protocols aim to improve standardization in terms of physiology by taking breast contact area and inelasticity into account. The purpose of this study is to estimate the potential for pressure protocols to reduce discomfort and pain, particularly the number of severe pain complaints for BCT-treated breasts. Methods: A prospective observational study including 58 women having one BCT-treated breast and one untreated nonsymptomatic breast, following our hospital's 18 decanewton (daN) compression protocol was performed. Breast thickness, applied force, contact area, mean pressure, breast volume, and inelasticity (mean E-modulus) were statistically compared between the within-women breast pairs, and data were used as predictors for severe pain, i.e., scores 7 and higher on an 11-point Numerical Rating Scale. Curve-fitting models were used to estimate how pressure-controlled protocols affect breast thickness, compression force, and pain experience. Results: BCT-treated breasts had on average 27% smaller contact areas, 30% lower elasticity, and 30% higher pain scores than untreated breasts (allp < 0.001). Contact area was the strongest predictor for severe pain (p < 0.01). Since BCT-treatment is associated with an average 0.36 dm{sup 2} decrease in contact area, as well as increased pain sensitivity, BCT-breasts had on average 5.3 times higher odds for severe pain than untreated breasts. Model estimations for a pressure-controlled protocol with a 10 kPa target pressure, which is below normal arterial pressure, suggest an average 26% (range 10%–36%) reduction in pain score, and an average 77% (range 46%–95%) reduction of the odds for severe pain. The estimated increase in thickness is +6.4% for BCT breasts. Conclusions: After BCT, women have hardly any choice in avoiding an annual follow-up mammogram. Model estimations show that a 10 kPa pressure-controlled protocol has the potential to reduce pain and severe pain particularly for these women. The results highly motivate conducting further research in larger subject groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-18A-05: Assessing Elekta MLC Tracking Performance

Purpose: To investigate the technical feasibility of using Elekta MLCs in tracked radiotherapy, specifically to show the capability of an Agility MLC to follow model tumor trajectories using object tracking. The system performance of the MLC is to be assessed via dosimetric experiments and temporal response measures. Methods: The system observer in the tracking cascade consisted of a camera serving for this proof of concept; Images of a moving object were acquired continuously and decorrelated for the position information, which was fed forward to the RT computer controlling the MLC via an interface provided by Elekta. The 1D motion (in the direction of the leaves) was induced by a CIRS motion controller. Additionally, the aperture position was observed by means of the light field of the linac. Calculating the phase between aperture and object yielded the mean aperture lag for the current setup. The object was restricted to sinusoidal motion with a period of 10s. For dosimetry, GafChromic radiosensitive film was irradiated with a total dose of 1000MU using an aperture size of 40mm and a motion range of 30mm. Results: Object tracking can substantially reconstruct the geometric dose response of a static target. In the dynamic case, dose is smeared out into the legs of the static distribution, leading to a reduced plateau and increased FWHM of 5mm, compared to the static width of 38mm. The time-lag between object and aperture was determined to be approximately 300ms for the current set-up. Conclusion: We demonstrated a tracking experiment performed on a clinical Elekta linear accelator for the first time. Observed profile variations show the dosimetric impact of tracked delivery. The determined lag is a valuable descriptor for a future tracking cascade employing predictor filters. The performed experiments are generic and possible predecessors for future applications with MR-Linac or ultrasound probes. Conflict of interest: this project is partly funded by Elekta.

60 APPLIED LIFE SCIENCES↗

TU-F-18C-02: Increasing Amorphous Selenium Thickness in Direct Conversion Flat-Panel Imagers for Contrast-Enhanced Dual-Energy Breast Imaging

Purpose: Contrast-enhanced (CE) breast imaging using iodinated contrast agents requires imaging with x-ray spectra at energies greater than those used in mammography. Optimizing amorphous selenium (a-Se) flat panel imagers (FPI) for this higher energy range may increase lesion conspicuity. Methods: We compare imaging performance of a conventional FPI with 200 μm a-Se conversion layer to a prototype FPI with 300 μm a-Se layer. Both detectors are evaluated in a Siemens MAMMOMAT Inspiration prototype digital breast tomosynthesis (DBT) system using low-energy (W/Rh 28 kVp) and high-energy (W/Cu 49 kVp) x-ray spectra. Detectability of iodinated lesions in dual-energy images is evaluated using an iodine contrast phantom. Effects of beam obliquity are investigated in projection and reconstructed images using different reconstruction methods. The ideal observer signal-to-noise ratio is used as a figure-of-merit to predict the optimal a-Se thickness for CE lesion detectability without compromising conventional full-field digital mammography (FFDM) and DBT performance. Results: Increasing a-Se thickness from 200 μm to 300 μm preserves imaging performance at typical mammographic energies (e.g. W/Rh 28 kVp), and improves the detective quantum efficiency (DQE) for high energy (W/Cu 49 kVp) by 30%. While the more penetrating high-energy x-ray photons increase geometric blur due to beam obliquity in the FPI with thicker a-Se layer, the effect on lesion detectability in FBP reconstructions is negligible due to the reconstruction filters employed. Ideal observer SNR for CE objects shows improvements in in-plane detectability with increasing a-Se thicknesses, though small lesion detectability begins to degrade in oblique projections for a-Se thickness above 500 μm. Conclusion: Increasing a-Se thickness in direct conversion FPI from 200 μm to 300 μm improves lesion detectability in CE breast imaging with virtually no cost to conventional FFDM and DBT. This work was partially supported by a research grant from Siemens Healthcare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-BRA-06: Quantification of Tracking Performance of a Multi-Layer Electronic Portal Imaging Device

Purpose: The purpose of this study was to quantify the improvement in tumor tracking, with and without fiducial markers, afforded by employing a multi-layer (MLI) electronic portal imaging device (EPID) over the current state-of-the-art, single-layer, digital megavolt imager (DMI) architecture. Methods: An ideal observer signal-to-noise ratio (d’) approach was used to quantify the ability of an MLI EPID and a current, state-of-the-art DMI EPID to track lung tumors from the treatment beam’s-eye-view. Using each detector modulation transfer function (MTF) and noise power spectrum (NPS) as inputs, a detection task was employed with object functions describing simple three-dimensional Cartesian shapes (spheres and cylinders). Marker-less tumor tracking algorithms often use texture discrimination to differentiate benign and malignant tissue. The performance of such algorithms is simulated by employing a discrimination task for the ideal observer, which measures the ability of a system to differentiate two image quantities. These were defined as the measured textures for benign and malignant lung tissue. Results: The NNPS of the MLI ∼25% of that of the DMI at the expense of decreased MTF at intermediate frequencies (0.25≤<f≤<0.5 cycles/mm). Lung tissue textures were found to follow a power-law trend in the frequency domain. It was found that for both fiducial marker tracking and lung tissue texture differentiation, the signal power of each task is retained at low frequencies. Thus, little difference may be observed in signal power when DMI and MLI are compared. In all cases, improvements in tracking were greater than a factor of 2. Conclusion: MLI performance in tumor tracking is greatly improved by the additional imager layers. This implies that further improvements in tracking may be gained through increasing the thickness of each MLI layer. For tracking, the MLI performance is limited by noise response. Losses in MTF result in negligible differences in d’. The project was partially supported by a grant from Varian Medical Systems, Inc. and grant No. R01CA188446-01 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Illuminating seafloor faults and ocean dynamics with dark fiber distributed acoustic sensing

Distributed fiber-optic sensing technology coupled to existing subsea cables (dark fiber) allows observation of ocean and solid earth phenomena. We used an optical fiber from the cable supporting the Monterey Accelerated Research System during a 4-day maintenance period with a distributed acoustic sensing (DAS) instrument operating onshore, creating a ~10,000-component, 20-kilometer-long seismic array. Recordings of a minor earthquake wavefield identified multiple submarine fault zones. Ambient noise was dominated by shoaling ocean surface waves but also contained observations of in situ secondary microseism generation, post–low-tide bores, storm-induced sediment transport, infragravity waves, and breaking internal waves. DAS amplitudes in the microseism band tracked sea-state dynamics during a storm cycle in the northern Pacific. These observations highlight this method’s potential for marine geophysics.

Lindsey, Nathaniel J.↗

Structural and electrical properties of metamorphic nanoheterostructures with a high InAs content (37-100%) grown on GaAs and InP substrates

A complex study of the structural and electrical properties of nanoheterostructures containing a metamorphic barrier with a high InAs content (37-100%) in the active region have been performed by the Van der Pauw and X-ray diffraction methods. All peaks observed in the rocking curves for the samples studied (throughout the entire structure) have been revealed and identified. It is shown that, having properly chosen the design of the metamorphic buffer and the compositional gradient in it, one can obtain mobilities and concentrations of the 2D electron gas in the In{sub x}Ga{sub 1-x}As quantum well in the heterostructures formed on GaAs substrates that are comparable with the corresponding values for the nanoheterostructures grown on InP substrates. It is established that the mobility and concentration of 2D electron gas depend both on the metamorphic barrier design and on the structural quality of heterostructure as a whole.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measurement of ion beam angular distribution at different helium gas pressures in a plasma focus device by large-area polycarbonate detectors

The paper presents an experimental study and analysis of full helium ion density angular distributions in a 4-kJ plasma focus device (PFD) at pressures of 10, 15, 25, and 30 mbar using large-area polycarbonate track detectors (PCTDs) (15-cm etchable diameter) processed by 50-Hz-HV electrochemical etching (ECE). Helium ion track distributions at different pressures, in particular, at the main axis of the PFD are presented. Maximum ion track density of ~4.4 × 10{sup 4} tracks/cm{sup 2} was obtained in the PCTD placed 6 cm from the anode. The ion distributions for all pressures applied are ring-shaped, which is possibly due to the hollow cylindrical copper anode used. The large-area PCTD processed by ECE proves, at the present state-of-theart, a superior method for direct observation and analysis of ion distributions at a glance with minimum efforts and time. Some observations of the ion density distributions at different pressures are reported and discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PRIME

SAND2021-0565 O PRIME is a modeling framework designed for the real-time characterization and forecasting of partially observed epidemics. The method is designed to help guide medical resource allocation in the early epoch of the outbreak. Characterization is the estimation of infection spread parameters using daily counts of symptomatic patients. The estimation problem is posed as one of Bayesian inference and solved using a Markov Chain Monte Carlo technique. The framework can accommodate multiple epidemic waves and can help identify different disease dynamics at the regional, state, and country levels. Examples are provided using publicly available COVID-19 data. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Safta, Cosmin↗

Principal Component Analysis for Extremes and Application to U.S. Precipitation

Here, we propose a method for analyzing extremal behavior through the lens of a most efficient basis of vectors. The method is analogous to principal component analysis, but is based on methods from extreme value analysis. Specifically, rather than decomposing a covariance or correlation matrix, we obtain our basis vectors by performing an eigendecomposition of a matrix that describes pairwise extremal dependence. We apply the method to precipitation observations over the contiguous United States. We find that the time series of large coefficients associated with the leading eigenvector shows very strong evidence of a positive trend, and there is evidence that large coefficients of other eigenvectors have relationships with El Niño–Southern Oscillation.

54 ENVIRONMENTAL SCIENCES↗