Search NASA⌕ Search

SEARCH · Search NASA

Results for “One”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Stability and magnetic behavior of exfoliable nanowire one-dimensional materials

Low-dimensional materials can display enhanced electronic, magnetic, and quantum properties. Here we use the topological scaling algorithm to identify all sufficiently metastable materials in the Materials Project database to identify bulk crystals with one-dimensional (1D) structural motifs: Five hundred fifty-one crystals that are within 50 meV atom –1 of the thermodynamic hull display 1D motifs, where 293 of these contain d-valence elements, which we focus on in this work. After exfoliating nanowires from 263 of these materials and calculating their thermodynamic stability using density functional theory, 103 nanowires meet per-atom and per-Ångström thermodynamic stability criteria. We illustrate for three nanowire systems that a variety of local minima can be present in these systems, demonstrating one case of a Peierls distortion. The wires display a broad diversity of electronic and magnetic properties of these nanowires, with 14 metals, 7 half-metals, and 82 semiconductors and insulators, and 41 nanowires displaying magnetic moments ranging from 0.1 to 5μ B per d-valence species when assuming ferromagnetic order. A subset of these chains are investigated for the impact of magnetic ordering, identifying 1D FeCl 3 to be most stable in an antiferromagnetic state. The electronic and magnetic properties of the identified 1D materials could enable applications in spintronic and quantum devices.

36 MATERIALS SCIENCE↗

SHMEMGraph: Efficient and Balanced Graph Processing Using One-Sided Communication

State-of-the-art synchronous graph processing frameworks face both inefficiency and imbalance issues that cause their performance to be suboptimal. These issues include the inefficiency of communication and the imbalanced graph computation/communication costs in an iteration. We propose to replace their conventional two-sided communication model with the one-sided counterpart. Accordingly, we design SHMEMGraph, an efficient and balanced graph processing framework that is formulated across a global memory space and takes advantage of the flexibility and efficiency of one-sided communication for graph processing. Through an efficient one-sided communication channel, SHMEMGraph utilizes the high-performance operations with RDMA while minimizing the resource contention within a computer node. In addition, SHMEMGraph synthesizes a number of optimizations to address both computation imbalance and communication imbalance. By using a graph of 1 billion edges, our evaluation shows that compared to the state-of-the-art Gemini framework, SHMEMGraph achieves an average improvement of 35.5% in terms of job completion time for five representative graph algorithms.

Fu, Huansong↗

Mapping Arbitrarily Sparse Two-body Interactions on One-dimensional Quantum Circuits

We consider an assignment problem arising in Fermionic-swap based mapping of the one-body and two-body interaction terms in simulating time evolution of a sparse second-quantized electronic structure Hamiltonian on a quantum computer. Relative efficiency of different swap networks depends on the relative costs of performing a swap layer and computing a Hamiltonian interaction term. Under the assumption that the interaction term cost dominates the computation, we develop an iterative algorithm that uses hypergraph optimal linear arrangement (HOLA) and partial distance-2 coloring to exploit arbitrary sparsity in the Hamiltonian for efficient computation using swap networks. Using a set of 122 problems from computational chemistry, we demonstrate performance improvements up to 100% relative to the state-of-the-art approaches for one-body terms and up to 86% utilization for two-body terms relative to a theoretical peak utilization. To the best of our knowledge, this is the first study to exploit arbitrary sparsity in orbital interactions for efficient computation on one-dimensional qubit connectivity layouts. The proposed algorithms form the basis for extension to map general k-body interactions that arise in other domains onto generalized qubit connectivity layouts.

quantum computing, Combinatorial Optimization, hyp↗

Scaling communication-intensive applications on BlueGene/P using one-sided communication and overlap

In earlier work, we showed that the one-sided communication model found in PGAS languages (such as UPC) offers significant advantages in communication efficiency by decoupling data transfer from processor synchronization. We explore the use of the PGAS model on IBM Blue-Gene/P, an architecture that combines low-power, quad-core processors with extreme scalability. We demonstrate that the PGAS model, using a new port of the Berkeley UPC compiler and GASNet one-sided communication layer, outperforms two-sided (MPI) communication in both microbenchmarks and a case study of the communication-limited benchmark, NAS FT. We scale the benchmark up to 16,384 cores of the BlueGene/P and demonstrate that UPC consistently outperforms MPI by as much as 66% for some processor configurations and an average of 32%. Additionally, the results demonstrate the scalability of the PGAS model and the Berkeley implementation of UPC, the viability of using it on machines with multicore nodes, and the effectiveness of the BG/P communication layer for supporting one-sided communication and PGAS languages.

97 MATHEMATICS AND COMPUTING↗

An Evaluation of One-Sided and Two-Sided Communication Paradigms on Relaxed-Ordering Interconnect

The Cray Gemini interconnect hardware provides multiple transfer mechanisms and out-of-order message delivery to improve communication throughput. In this paper we quantify the performance of one-sided and two-sided communication paradigms with respect to: 1) the optimal available hardware transfer mechanism, 2) message ordering constraints, 3) per node and per core message concurrency. In addition to using Cray native communication APIs, we use UPC and MPI micro-benchmarks to capture one- and two-sided semantics respectively. Our results indicate that relaxing the message delivery order can improve performance up to 4.6x when compared with strict ordering. When hardware allows it, high-level one-sided programming models can already take advantage of message reordering. Enforcing the ordering semantics of two-sided communication comes with a performance penalty. Furthermore, we argue that exposing out-of-order delivery at the application level is required for the next-generation programming models. Any ordering constraints in the language specifications reduce communication performance for small messages and increase the number of active cores required for peak throughput.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration

Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilities of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions. Conclusion: LOOP can cooperate with any fitting routine functioning as a “robust fit”. In addition, it can be set as a benchmark for film-dose calibration fitting performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-G-BRF-04: Robust Real-Time Volumetric Imaging Based On One Single Projection

Purpose: Real-time volumetric imaging is highly desirable to provide instantaneous image guidance for lung radiation therapy. This study proposes a scheme to achieve this goal using one single projection by utilizing sparse learning and a principal component analysis (PCA) based lung motion model. Methods: A patient-specific PCA-based lung motion model is first constructed by analyzing deformable vector fields (DVFs) between a reference image and 4DCT images at each phase. At the training stage, we “learn” the relationship between the DVFs and the projection using sparse learning. Specifically, we first partition the projections into patches, and then apply sparse learning to automatically identify patches that best correlate with the principal components of the DVFs. Once the relationship is established, at the application stage, we first employ a patchbased intensity correction method to overcome the problem of different intensity scale between the calculated projection in the training stage and the measured projection in the application stage. The corrected projection image is then fed to the trained model to derive a DVF, which is applied to the reference image, yielding a volumetric image corresponding to the projection. We have validated our method through a NCAT phantom simulation case and one experiment case. Results: Sparse learning can automatically select those patches containing motion information, such as those around diaphragm. For the simulation case, over 98% of the lung region pass the generalized gamma test (10HU/1mm), indicating combined accuracy in both intensity and spatial domain. For the experimental case, the average tumor localization errors projected to the imager are 0.68 mm and 0.4 mm on the axial and tangential direction, respectively. Conclusion: The proposed method is capable of accurately generating a volumetric image using one single projection. It will potentially offer real-time volumetric image guidance to facilitate lung radiotherapy. This study is supported in part by NIH (1R01CA154747-01), The Core Technology Research in Strategic Emerging Industry, Guangdong, China(2011A081402003)

60 APPLIED LIFE SCIENCES↗

SU-A-BRA-02: Making the Most of a One Hour Lecture with Alternative Teaching Methodologies: Implementing Project-Based and Flipped Learning

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Single Crystal X-ray Study of 6-Phenyl-4-(p-tolyl)pyridin-2(1H)-one

The title compound 6-phenyl-4-(p-tolyl)pyridin-2(1H)-one was synthesized via one-pot, three component reaction of (E)-1-phenyl-3-(p-tolyl)-2-propen-1-one, ethyl 2-nitroacetate and ammonium acetate in refluxing ethanol, as a shiny green crystalline solid in 83% yield. Its structure was characterized by spectral studies and unambiguously corroborated by X-ray diffraction crystallography. The crystals of title compound are monoclinic, sp. gr. P2{sub 1}/n, a = 11.8346(7) Å, b = 13.4413(9) Å, c = 17.7626(10) Å, β = 99.479(5)°, and Z = 8. All the rings in molecule of the title compound are planar. Hydrogen interactions play significant role in stabilizing the crystal structure and the supramolecular aggregate of molecules is facilitated by strong N–H···O and C–H···O type of hydrogen interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functional renormalization-group approaches, one-particle (irreducible) reducible with respect to local Green’s functions, with dynamical mean-field theory as a starting point

We consider formulations of the functional renormalization-group (fRG) flow for correlated electronic systems with the dynamical mean-field theory as a starting point. We classify the corresponding renormalization-group schemes into those neglecting one-particle irreducible six-point vertices (with respect to the local Green’s functions) and neglecting one-particle reducible six-point vertices. The former class is represented by the recently introduced DMF{sup 2}RG approach [31], but also by the scale-dependent generalization of the one-particle irreducible representation (with respect to local Green’s functions, 1PI-LGF) of the generating functional [20]. The second class is represented by the fRG flow within the dual fermion approach [16, 32]. We compare formulations of the fRG approach in each of these cases and suggest their further application to study 2D systems within the Hubbard model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analytic continuation of scattering data to the region of negative energies for systems that have one and two bound states

An exactly solvable potential model is used to study the possibility of deducing information about the features of bound states for the system under consideration (binding energies and asymptotic normalization coefficients) on the basis of data on continuum states. The present analysis is based on an analytic approximation and on the subsequent continuation of a partial-wave scattering function from the region of positive energies to the region of negative energies. Cases where the system has one or two bound states are studied. The α+d and α+{sup 12}C systems are taken as physical examples. In the case of one bound state, the scattering function is a smooth function of energy, and the procedure of its analytic continuation for different polynomial approximations leads to close results, which are nearly coincident with exact values. In the case of two bound states, the scattering function has two poles—one in the region of positive energies and the other in the region of negative energies between the energies corresponding to the two bound states in question. Padéapproximants are used to reproduce these poles. The inclusion of these poles proves to be necessary for correctly describing the properties of the bound states.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effective field theory analysis of the Coulomb breakup of the one-neutron halo nucleus $$^{19}$$C

Abstract We analyse the Coulomb breakup of $$^{19}$$ 19 C measured at 67 A MeV at RIKEN. We use the Coulomb-Corrected Eikonal (CCE) approximation to model the reaction and describe the one-neutron halo nucleus $$^{19}$$ 19 C within Halo Effective Field Theory (Halo EFT). At leading order we obtain a fair reproduction of the measured cross section as a function of energy and angle. The description is insensitive to the choice of optical potential, as long as it accurately represents the size of $${}^{18}$$ 18 C. It is also insensitive to the interior of the $${}^{19}$$ 19 C wave function. Comparison between theory and experiment thus enables us to infer asymptotic properties of the ground state of $$^{19}$$ 19 C: these data put constraints on the one-neutron separation energy of this nucleus and, for a given binding energy, can be used to extract an asymptotic normalisation coefficient (ANC). These results are confirmed by CCE calculations employing next-to-leading order Halo EFT descriptions of $${}^{19}$$ 19 C: at this order the results for the Coulomb breakup cross section are completely insensitive to the choice of the regulator. Accordingly, this reaction can be used to constrain the one-neutron separation energy and ANC of $${}^{19}$$ 19 C.

Physics↗

Global analysis of dark matter simplified models with leptophobic spin-one mediators using MasterCode

Abstract We report the results of a global analysis of dark matter simplified models (DMSMs) with leptophobic mediator particles of spin one, considering the cases of both vector and axial-vector interactions with dark matter (DM) particles and quarks. We require the DMSMs to provide all the cosmological DM density indicated by Planck and other observations, and we impose the upper limits on spin-independent and -dependent scattering from direct DM search experiments. We also impose all relevant LHC constraints from searches for monojet events and measurements of the dijet mass spectrum. We model the likelihood functions for all the constraints and combine them within the framework, and probe the full DMSM parameter spaces by scanning over the mediator and DM masses and couplings, not fixing any of the model parameters. We find, in general, two allowed regions of the parameter spaces: one in which the mediator couplings to Standard Model (SM) and DM particles may be comparable to those in the SM and the cosmological DM density is reached via resonant annihilation, and one in which the mediator couplings to quarks are $$\lesssim \, 10^{-3}$$ ≲ 10 - 3 and DM annihilation is non-resonant. We find that the DM and mediator masses may well lie within the ranges accessible to LHC experiments. We also present predictions for spin-independent and -dependent DM scattering, and present specific results for ranges of the DM couplings that may be favoured in ultraviolet completions of the DMSMs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accelerating LHC phenomenology with analytic one-loop amplitudes: A C++ interface to MCFM

Abstract The evaluation of one-loop matrix elements is one of the main bottlenecks in precision calculations for the high-luminosity phase of the Large Hadron Collider. To alleviate this problem, a new C++ interface to the "Image missing" <#comment/> parton-level Monte Carlo is introduced, giving access to an extensive library of analytic results for one-loop amplitudes. Timing comparisons are presented for a large set of Standard Model processes. These are relevant for high-statistics event simulation in the context of experimental analyses and precision fixed-order computations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ARKODE: A Flexible IVP Solver Infrastructure for One-step Methods

We describe the ARKODE library of one-step time integration methods for ordinary differential equation (ODE) initial-value problems (IVPs). In addition to providing standard explicit and diagonally implicit Runge–Kutta methods, ARKODE supports one-step methods designed to treat additive splittings of the IVP, including implicit-explicit (ImEx) additive Runge–Kutta methods and multirate infinitesimal (MRI) methods. We present the role of ARKODE within the SUNDIALS suite of time integration and nonlinear solver libraries, the core ARKODE infrastructure for utilities common to large classes of one-step methods, as well as its use of “time stepper” modules enabling easy incorporation of novel algorithms into the library. Numerical results show example problems of increasing complexity, highlighting the algorithmic flexibility afforded through this infrastructure, and include a larger multiphysics application leveraging multiple algorithmic features from ARKODE and SUNDIALS.

97 MATHEMATICS AND COMPUTING↗

Entanglement Area Law in Disordered Free Fermion Anderson Model in One, Two, and Three Dimensions

We calculate numerically the entanglement entropy of free fermion ground states in one-, two-, and three-dimensional Anderson models and find that it obeys the area law as long as the linear size of the subsystem is sufficiently larger than the mean free path. This result holds in the metallic phase of the three-dimensional Anderson model, where the mean free path is finite although the localization length is infinite. Relation between the present results and earlier ones on area law violation in special one-dimensional models that support metallic phases is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Limitations of one-dimensional mesoscale PBL parameterizations in reproducing mountain-wave flows

In this study, mesoscale models are considered to be the state of the art in modeling mountain-wave flows. Herein, we investigate the role and accuracy of planetary boundary layer (PBL) parameterizations in handling the interaction between large-scale mountain waves and the atmospheric boundary layer. To that end, we use recent large-eddy simulation (LES) results of mountain waves over a symmetric two-dimensional bell-shaped hill [Sauer et al., J. Atmos. Sci. (2015)], and compare them to four commonly used PBL schemes. We find that one-dimensional PBL parameterizations produce reasonable agreement with the LES results in terms of vertical wavelength, amplitude of velocity and turbulent kinetic energy distribution in the downhill shooting flow region. However, the assumption of horizontal homogeneity in PBL parameterizations does not hold in the context of these complex flow configurations. This inappropriate modeling assumption results in a vertical wavelength shift producing errors of ≈ 10 m s–1 at downstream locations due to the presence of a coherent trapped lee wave that does not mix with the atmospheric boundary layer. In contrast, horizontally-integrated momentum flux derived from these PBL schemes displays a realistic pattern. Therefore results from mesoscale models using ensembles of one-dimensional PBL schemes can still potentially be used to parameterize drag effects in general circulation models. Nonetheless, three-dimensional PBL schemes must be developed in order for mesoscale models to accurately represent complex-terrain and other types of flows where one-dimensional PBL assumptions are violated.

54 ENVIRONMENTAL SCIENCES↗