Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

NASA Tech Briefs, November 2003

Topics covered include: Computer Program Recognizes Patterns in Time-Series Data; Program for User-Friendly Management of Input and Output Data Sets; Noncoherent Tracking of a Source of a Data-Modulated Signal; Software for Acquiring Image Data for PIV; Detecting Edges in Images by Use of Fuzzy Reasoning; A Timer for Synchronous Digital Systems; Prototype Parts of a Digital Beam-Forming Wide-Band Receiver; High-Voltage Droplet Dispenser; Network Extender for MIL-STD-1553 Bus; MMIC HEMT Power Amplifier for 140 to 170 GHz; Piezoelectric Diffraction-Based Optical Switches; Numerical Modeling of Nanoelectronic Devices; Organizing Diverse, Distributed Project Information; Eigensolver for a Sparse, Large Hermitian Matrix; Modified Polar-Format Software for Processing SAR Data; e-Stars Template Builder; Software for Acoustic Rendering; Functionally Graded Nanophase Beryllium/Carbon Composites; Thin Thermal-Insulation Blankets for Very High Temperatures; Prolonging Microgravity on Parabolic Airplane Flights; Device for Locking a Control Knob; Cable-Dispensing Cart; Foam Sensor Structures Would be Self-Deployable and Survive Hard Landings; Real-Gas Effects on Binary Mixing Layers; Earth-Space Link Attenuation Estimation via Ground Radar Kdp; Wedge Heat-Flux Indicators for Flash Thermography; Measuring Diffusion of Liquids by Common-Path Interferometry; Zero-Shear, Low-Disturbance Optical Delay Line; Whispering-Gallery Mode-Locked Lasers; Spatial Light Modulators as Optical Crossbar Switches; Update on EMD and Hilbert-Spectra Analysis of Time Series; Quad-Tree Visual-Calculus Analysis of Satellite Coverage; Dyakonov-Perel Effect on Spin Dephasing in n-Type GaAs; Update on Area Production in Mixing of Supercritical Fluids; and Quasi-Sun-Pointing of Spacecraft Using Radiation Pressure.

Source record↗

Wavefront Sensing Analysis of Grazing Incidence Optical Systems

Wavefront sensing is a process by which optical system errors are deduced from the aberrations in the image of an ideal source. The method has been used successfully in near-normal incidence, but not for grazing incidence systems. This innovation highlights the ability to examine out-of-focus images from grazing incidence telescopes (typically operating in the x-ray wavelengths, but integrated using optical wavelengths) and determine the lower-order deformations. This is important because as a metrology tool, this method would allow the integration of high angular resolution optics without the use of normal incidence interferometry, which requires direct access to the front surface of each mirror. Measuring the surface figure of mirror segments in a highly nested x-ray telescope mirror assembly is difficult due to the tight packing of elements and blockage of all but the innermost elements to normal incidence light. While this can be done on an individual basis in a metrology mount, once the element is installed and permanently bonded into the assembly, it is impossible to verify the figure of each element and ensure that the necessary imaging quality will be maintained. By examining on-axis images of an ideal point source, one can gauge the low-order figure errors of individual elements, even when integrated into an assembly. This technique is known as wavefront sensing (WFS). By shining collimated light down the optical axis of the telescope and looking at out-of-focus images, the blur due to low-order figure errors of individual elements can be seen, and the figure error necessary to produce that blur can be calculated. The method avoids the problem of requiring normal incidence access to the surface of each mirror segment. Mirror figure errors span a wide range of spatial frequencies, from the lowest-order bending to the highest order micro-roughness. While all of these can be measured in normal incidence, only the lowest-order contributors can be determined through this WFS technique.

Rohrbach, Scott↗

Effect of Jitter on Linear Pulse-Characterization Techniques

Linear pulse-characterization techniques based on electrically driven temporal modulators can measure the electric field of optical pulses with high sensitivity and accuracy. Synchronization of the electric-drive signal to the optical source under test is paramount to their implementation, and it is important to understand the impact of relative synchronization jitter on the measured experimental trace and on the reconstructed electric field. Derivations and simulations are presented for linear spectrography, spectral shearing interferometry, and simplified chronocyclic tomography. For these three techniques, accurate characterization is obtained for relative jitter with a standard deviation as high as several times the pulse duration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observations of Circumstellar Disks with Infrared Interferometry

Star formation is arguably the area of astrophysics in which infrared interferometry has had the biggest impact. The optically thick portion of T Tauri and Herbig Ae/Be disks DO NOT extend to a few stellar radii of the stellar surface. Emission is coming from near the dust sublimation radius, but not all from a single radius. The Herbig Ae stars can be either flared or self-shadowed but very massive (early Be) stars are geometrically thin. The Herbig Ae stars can be either flared or self-shadowed but very massive (early Be) stars are geometrically thin. Observational prospects are rapidly improving: a) Higher spectral resolution will allow observations of the gas: jets, winds, accretion. b) Closure phase and imaging will help eliminate model uncertainties/dependencies.

young steller objects↗

Optical Testing of Retroreflectors for Cryogenic Applications

A laser tracker (LT) is an important coordinate metrology tool that uses laser interferometry to determine precise distances to objects, points, or surfaces defined by an optical reference, such as a retroreflector. A retroreflector is a precision optic consisting of three orthogonal faces that returns an incident laser beam nearly exactly parallel to the incident beam. Commercial retroreflectors are designed for operation at room temperature and are specified by the divergence, or beam deviation, of the returning laser beam, usually a few arcseconds or less. When a retroreflector goes to extreme cold (.35 K), however, it could be anticipated that the precision alignment between the three faces and the surface figure of each face would be compromised, resulting in wavefront errors and beam divergence, degrading the accuracy of the LT position determination. Controlled tests must be done beforehand to determine survivability and these LT coordinate errors. Since conventional interferometer systems and laser trackers do not operate in vacuum or at cold temperatures, measurements must be done through a vacuum window, and care must be taken to ensure window-induced errors are negligible, or can be subtracted out. Retroreflector holders must be carefully designed to minimize thermally induced stresses. Changes in the path length and refractive index of the retroreflector have to be considered. Cryogenic vacuum testing was done on commercial solid glass retroreflectors for use on cryogenic metrology tasks. The capabilities to measure wavefront errors, measure beam deviations, and acquire laser tracker coordinate data were demonstrated. Measurable but relatively small increases in beam deviation were shown, and further tests are planned to make an accurate determination of coordinate errors.

Ohl, Raymond G.↗

Generation of gamma radiation by a subterawatt ultrashort laser pulse: optimisation of preplasma and pulse duration

We report an experimental and numerical study of the acceleration of electrons in a plasma interacting with a subterawatt laser pulse (intensity of ∼3 × 10{sup 18} W cm{sup −2} at a pulse duration of 50 fs). A preplasma layer on the surface of a molybdenum target is formed by an additional laser pulse with a duration of 8 ns and an intensity of ∼2 × 10{sup 12} W cm{sup −2}. It is shown that an increase in the laser pulse duration to 1700 fs at a constant energy (and a proportional decrease in intensity) leads to an increase in the yield of bremsstrahlung γ-radiation by more than an order of magnitude when the nanosecond pulse is ahead of the femtosecond one by 15 − 25 ns. Interferometry data and results of diagnostics of optical and γ-radiation of a plasma demonstrate that the collisional ionisation of atoms by electrons oscillating in the field of such a laser pulse plays an essential role in the formation of electron density profile. The sensitivity of the described effect to the level of amplified spontaneous emission is determined, despite the nanosecond pulse impact. Numerical simulations show that at a large pulse duration, the acceleration of electrons is stipulated by the beaking of plasma waves excited during stimulated Raman scattering of laser radiation. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Holographic and time-resolving ability of pulse-pair two-dimensional velocity interferometry

Previous velocity interferometers used at research laboratories for shock physics experiments measured target motion at a point or many points on a line on the target. Recently, a two-dimensional (2d) version (2d-velocity interferometer system for any reflector) has been demonstrated using a pair of ultrashort (3 ps) pulses for illumination, separated by 268 ps. We have discovered new abilities for this instrument, by treating the complex output image as a hologram. For data taken in an out of focus configuration, we can Fourier process to bring narrow features such as cracks into sharp focus, which are otherwise completely blurred. This solves a practical problem when using high numerical aperture optics having narrow depth of field to observe moving surface features such as cracks. Furthermore, theory predicts that the target appearance (position and reflectivity) at two separate moments in time are recorded by the main and conjugate images of the same hologram, and are partially separable during analysis for narrow features. Hence, for the cracks we bring into refocus, we can make a two-frame movie with a subnanosecond frame period. Longer and shorter frame periods are possible with different interferometer delays. Since the megapixel optical detectors we use have superior spatial resolution over electronic beam based framing cameras, this technology could be of great use in studying microscopic three-dimensional-behavior of targets at ultrafast times scales. Demonstrations on shocked silicon are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flow characterization in the NASA Ames 16-inch Shock Tunnel

Flow characteristics of NASA's 16-Inch Shock Tunnel are determined for purposes of providing hypersonic propulsion simulation capability. The key tunnel operating parameters are the incident shock speed and reservoir pressure and enthalpy. Flow characteristics of concern are the nozzle exit pressure, temperature, Mach number, Reynolds number, chemical composition, and flow uniformity. Surface mounted gages (for pressure and heat transfer) and nonintrusive optical flow diagnostics (emission and absorption spectroscopy and holographic interferometry) are used to verify tunnel conditions. Experimental measurements are used to validate computational analysis for predicting facility performance, and CFD is used to interpret the free stream optical diagnostic measurements.

Cavolowsky, John A.↗

Estimation of full-field dynamic strains from digital video measurements of output-only beam structures by video motion processing and modal superposition

Strain is an necessary quantity to characterize local structural behaviors and directly correlates with structural damage initiation and development that is within local regions. Strain measurement at high spatial resolution (density) locations is thus required to characterize local structural behaviors and detect potential local damage. Traditional contact-type strain gauges are mostly discrete point-wise sensors that can only be placed in a limited number of positions. Distributed optical fiber sensing techniques can measure strains at spatially dense measurement points, but their instrumentation is a time- and labor-intensive process associated with the issue of the fragility of fibers. Noncontact optical measurement techniques, such as a family of interferometry techniques using laser beams (e.g., laser Doppler vibrometers), can provide vibration measurement at high density spatial points without the need to install sensors on the structure. Yet, these measurement devices are active sensing methods that are relatively expensive and vulnerable to ambient motion. Photogrammetry is an alternative noncontact optical measurement method using (passive) white-light imaging of digital video cameras that are relatively low-cost, agile, and provides simultaneous measurements at high spatial density locations where every pixel becomes a measurement point. Among others, digital image correlation can achieve full-field deformation measurements and subsequently estimate the full-field strains. However, it is computationally extensive. This research develops a new efficient approach to estimate the full-field (as many measurement points as the pixel number of the video frame on the structure) dynamic strains at high-spatial (pixel)-resolution/density location points from the digital video measurement of output-only vibrating structures. The developed approach is based on phase-based video motion estimation and modal superposition of structural dynamic response. Moreover, the method is augmented by a high-fidelity finite element model, which is updated with the full-field experimental modal parameters “blindly” identified from the video measurement of the output-only structure. Laboratory experiments are conducted to validate the method on a bench-scale cantilever beam structure. Results demonstrate that the full-field dynamic strain estimated by the developed approach from the video measurement of the output-only vibrating beam match very well those directly measured by the strain gauges (at discrete measurement points). Some factors associated with the effectiveness of the method are experimentally studied and discussed.

47 OTHER INSTRUMENTATION↗

Collaborative development of diffraction-limited beamline optical systems at US DOE light sources

An ongoing collaboration among four US Department of Energy National Laboratories has demonstrated key technology prototypes and software modeling tools required for new high-coherent flux beamline optical systems. New free electron laser (FEL) and diffraction-limited storage ring (DLSR) light sources demand wavefront preservation from source to sample to achieve and maintain optimal performance. Fine wavefront control was achieved using a novel, roomtemperature cooled mirror system called REAL (resistive element adjustable length) that combines cooling with applied, spatially variable auxiliary heating. Single-grating shearing interferometry (also called Talbot interferometry) and Hartmann wavefront sensors were developed and used for optical characterization and alignment on several beamlines, across a range of photon energies. Demonstrations of non-invasive hard x-ray wavefront sensing were performed using a thin diamond single-crystal as a beamsplitter.

Goldberg, Kenneth A.↗

Analysis of localized fringes in the holographic optical Schlieren system

The relation between localization of interference fringes in classical and holographic interferometry is reviewed and an application of holographic interferometry is considered for which the object is a transparent medium with nonhomogeneous refractive index. The technique is based on the analysis of the optical path length change of the object wave as it propagates through a transparent medium. Phase shifts due to variations of the speed of light within the medium give rise to an interference pattern. The resulting interferogram can be used to determine the physical properties of the medium or transparent object. Such properties include the mass density of fluids, electron densities of plasmas, the temperature of fluids, the chemical species concentration of fluids, and the state of stress in solids. The optical wave used can be either a simple plane or spherical wave, or it may be a complicated spatial wave scattered by a diffusing screen. The mathematical theory on the formation and analysis of localized fringes, the general theoretical concepts used, and a computer code for analysis are included along with the inversion of fringe order data.

Kurtz, R. L.↗

Optical Response of Soda-Lime Glass Shocked to 14 GPa

To investigate the potential use of soda-lime glass (SLG) as an optical window in shock wave experiments, laser interferometry (VISAR) was used to determine the window correction and the refractive index in SLG samples subjected to plane shock wave compression. Symmetric plate impact experiments were conducted at peak stresses varying between 4 and 14 GPa and laser interferometry ($λ_0$ = 532$\textit {nm}$ wavelength) measurements were used to monitor the particle velocity histories at the impact surface. The higher stress experiments displayed a constant state prior to stress unloading. In contrast, the lower stress experiments (4.3 and 7.8 GPa) displayed an initial constant state followed by weakly time-dependent response prior to stress unloading. Because the actual particle velocities were independently known from the projectile velocity measurements, the window correction factor and the refractive index changes were determined over the stress range examined. Above 7.5 GPa, our window correction and refractive index results show significant differences with previously published data for the same material. Potential reasons for these differences are indicated.

36 MATERIALS SCIENCE↗

Characteristics of plasma properties in an ablative pulsed plasma thruster

Pulsed plasma thrusters are electric space propulsion devices which create a highly transient plasma bulk in a short-time arc discharge that is expelled to create thrust. The transitional character and the dependency on the discharge properties are yet to be elucidated. In this study, optical emission spectroscopy and Mach-Zehnder interferometry are applied to investigate the plasma properties in variation of time, space, and discharge energy. Electron temperature, electron density, and Knudsen numbers are derived for the plasma bulk and discussed. Temperatures were found to be in the order of 1.7 to 3.1 eV, whereas electron densities showed maximum values of more than 10{sup 17} cm{sup -3}. Both values showed strong dependency on the discharge voltage and were typically higher closer to the electrodes. Capacitance and time showed less influence. Knudsen numbers were derived to be in the order of 10{sup -3}-10{sup -2}, thus, indicating a continuum flow behavior in the main plasma bulk.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multipoint sensing with a low-coherence source using single-arm frequency-shifted interferometry

We demonstrate that multiple-site sensing along an optical fiber can be done with incoherent continuous-wave light. Here, using a broadband low-coherence noise source, a slow detector, and an optical modulator, we construct a single-arm frequency-shifted interferometer (SA-FSI) capable of simultaneously sensing multiple weak-reflection sites distributed either in parallel or in series along fiber links. By scanning the driving frequency of an electro-optic amplitude modulator in the range of 2.7–3.2 GHz at steps of 41.7 KHz, we demonstrate a spatial resolution of 0.3 m and a measurement range of over 1 km.

36 MATERIALS SCIENCE↗

Preliminary characterization of active MEMS valves.

Partial characterization of a series of electrostatically actuated active microfluidic valves is to be performed. Tests are performed on a series of 24 valves from two different MEMS sets. Focus is on the physical deformation of the structures under variable pressure loadings, as well as voltage levels. Other issues that inhibit proper performance of the valves are observed, addressed and documented as well. Many microfluidic applications have need for the distribution of gases at finely specified pressures and times. To this end a series of electrostatically actuated active valves have been fabricated. Eight separate silicon die are discussed, each with a series of four active valves present. The devices are designed such that the valve boss is held at a ground, with a voltage applied to lower contacts. Resulting electrostatic forces pull the boss down against a series of stops, intended to create a seal as well as prevent accidental shorting of the device. They have been uniquely packaged atop a stack of material layers, which have inlaid channels for application of fluid flow to the backside of the valve. Electrical contact is supplied from the underlying printed circuit board, attached to external supplies and along traces on the silicon. Pressure is supplied from a reservoir of house compressed air, up to 100 Psig. This is routed through a Norgren R07-200-RGKA pressure regulator, rated to 150 Psig. From there flow passes a manually operated ball valve, and to a flow meter. Two flow meters were utilized; initially an Omega FMA1802 rated at 10 sccm, and followed by a Flocat model for higher flow rates up to 100 sccm. An Omega DPG4000-500 pressure gauge produced pressure measurements. Optical measurements were returned via a WYKO Interferometry probe station. This would allow for determination of physical deformations of the device under a variety of voltage and pressure loads. This knowledge could lead to insight as to the failure mechanisms of the device, yielding improvements for subsequent fabrications.

47 OTHER INSTRUMENTATION↗

New Strainmeters used to Monitor Deformation During Injection and Withdrawal

Injecting or removing fluids from reservoirs or aquifers causes deformation that can be used as a diagnostic signal in some cases, while it can interfere with geodetic interpretations in other cases. This has motivated us to develop instrumentation and methods to characterize the strain field resulting from injection and pumping. Three new instruments have been deployed at our field stations near Clemson University and at the Avant Field north of Tulsa, OK. Two use non-contact eddy current transducers configured to measure four components of strain and two tilts to 1 part-per-billion. One system is designed for permanent installation, the other is removable for short term deployments. Another system is a low cost volumetric strainmeter consisting of an embedded optical fiber that is interrogated using laser interferometry. This strainmeter is designed to be a permanently installed and has a resolution of several parts-per-trillion. The field sites are designed to characterize strains during pumping or injection over different scales and in different geologic settings. The Clemson field station is underlain by biotite gneiss, a low permeability crystalline rock overlain by moderate permeability, soft saprolite above 30m depth. The water table is at approximately 9m depth. The strainmeters are in the crystalline rock at approximately 40m depth, and pumping occurs in the overlying saprolite. In contrast, wells at the Avant Field site are much deeper. They are approximately 500m deep and completed in a 25-m-thick oil-bearing sandstone. Strainmeters at the Avant Field are at ~30m depth. These two sites provide contrasting approaches to characterizing strain at 30-40m depth. Water is pumped from an overlying formation at the Clemson site, whereas it is pumped from a much deeper underlying formation at the Avant Field. Preliminary results are available from a brief injection test, and from a longer shut-in test at the Avant Field. Injection is characterized by an increase in tensile strains in both the radial and circumferential directions approximately 220m from the well. The shut-in was characterized by radial tension and circumferential compression in response to a well approximately 1km from the strainmeter. These are the expected signals caused by injection and shut-in according to poroelastic simulations.

DeWolf, Scott↗