Search NASA⌕ Search

SEARCH · Search NASA

Results for “PENETRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Evolution of London penetration depth with scattering in single crystals of K1-xNaxFe2As2

London penetration depth, λ(T), was measured in single crystals of K1-xNaxFe2As2, x=0 and 0.07, down to temperatures of 50 mK, ~Tc/50. Isovalent substitution of Na for K significantly increases impurity scattering, with ρ(Tc) rising from 0.2 to 2.2 μΩ cm, and leads to a suppression of Tc from 3.5 to 2.8 K. At the same time, a close to T-linear Δλ(T) in pure samples changes to almost T2 in the substituted samples. The behavior never becomes exponential as expected for the accidental nodes, as opposed to T2 dependence in superconductors with symmetry imposed line nodes. The superfluid density in the full temperature range follows a simple clean and dirty d-wave dependence, for pure and substituted samples, respectively. This result contradicts suggestions of multiband scenarios with strongly different gap structure on four sheets of the Fermi surface.

36 MATERIALS SCIENCE↗

Spatially resolved penetration depth measurements and vortex manipulation in the ferromagnetic superconductor ErNi 2 B 2 C

We present a local probe study of the magnetic superconductor ErNi 2 B 2 C, using magnetic force microscopy at sub-Kelvin temperatures. ErNi 2 B 2 C is an ideal system to explore the effects of concomitant superconductivity and ferromagnetism. At 500 mK, far below the transition to a weakly ferromagnetic state, we directly observe a structured magnetic background on the micrometer scale. We determine spatially resolved absolute values of the magnetic penetration depth λ and study its temperature dependence as the system undergoes magnetic phase transitions from paramagnetic to antiferromagnetic, and to weak ferromagnetic, all within the superconducting regime. We estimate the absolute pinning force of Abrikosov vortices, which shows a position dependence and temperature dependence as well, and discuss the possibility of the purported spontaneous vortex formation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing the superconducting gap symmetry of α - PdBi 2 : A penetration depth study

In this paper, we report measurements of the in-plane London penetration depth λ in single crystals of the α - PdBi 2 superconductor—the α-phase counterpart of the putative topological superconductor β - PdBi 2 , down to 0.35 K using a high-resolution tunnel-diode-based technique. Both λ and superfluid density ρ s exhibit an exponential behavior for T ≤ 0.35T c , with Δ(0) /k B T c ~ 2.0, ΔC/γT c ~ 2.0, and λ(0) ~ 140 nm, showing that α - PdBi 2 is a moderately coupling, fully gapped superconductor. Finally, the values of Δ(0) and ΔC/γT c are consistent with each other via strong-coupling corrections.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In-plane magnetic penetration depth of superconducting CaKFe 4 As 4

Here, the temperature dependence of the in-plane magnetic penetration depth (λ ab ) in an extensively characterized sample of superconducting CaKFe 4 As 4 (T c ≃35K) was investigated using muon-spin rotation (μSR). A comparison of λ –2 ab (T) measured by μSR with the one inferred from angle-resolved photoemission spectroscopy (ARPES) data confirms the presence of multiple gaps at the Fermi level. An agreement between μSR and ARPES requires the presence of additional bands, which are not resolved by ARPES experiments. These bands are characterized by small superconducting gaps with an average zero-temperature value of Δ 0 =2.4(2)meV. Our data suggest that in CaKFe 4 As 4 the s ± order parameter symmetry acquires a more sophisticated form by allowing a sign change not only between electron and hole pockets, but also within pockets of similar type.

36 MATERIALS SCIENCE↗

Nodeless superconductivity in the type-II Dirac semimetal PdTe 2 : London penetration depth and pairing-symmetry analysis

Superconducting gap structure was probed in type-II Dirac semimetal PdTe 2 by measuring the London penetration depth using the tunnel diode resonator technique. At low temperatures, the data for two samples are well described by a weak-coupling exponential fit yielding λ( T = 0) = 230 nm as the only fit parameter at a fixed Δ(0)/ T c ≈ 1.76, and the calculated superfluid density is consistent with a fully gapped superconducting state characterized by a single gap scale. Electrical resistivity measurements for in-plane and inter-plane current directions find very low and nearly temperature-independent normal-state anisotropy. The temperature dependence of resistivity is typical for conventional phonon scattering in metals. Here, we compare these experimental results with expectations from a detailed theoretical symmetry analysis and reduce the number of possible superconducting pairing states in PdTe 2 to only three nodeless candidates: a regular, topologically trivial s-wave pairing, and two distinct odd-parity triplet states that both can be topologically nontrivial depending on the microscopic interactions driving the superconducting instability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dependence of the absolute value of the penetration depth in ( Ba 1 – x K x ) Fe 2 As 2 on doping

Here, we report magnetic force microscopy (MFM) measurements on the iron-based superconductor Ba 1–x K x Fe 2 As 2 . By measuring locally the Meissner repulsion with the magnetic MFM tip, we determine the absolute value of the in-plane magnetic penetration depth (λ ab ) in underdoped, optimally doped, and overdoped samples. The results suggest an abrupt increase of λ ab as doping is increased from x opt , which is potentially related to the presence of a quantum critical point. The response of superconducting vortices to magnetic forces exerted by the MFM tip for x = 0.19 and 0.58 is compatible with previously observed structural symmetries at those doping levels.

36 MATERIALS SCIENCE↗

Monotonic properties of the shift and penetration factors

Here, we study derivatives of the shift and penetration factors of collision theory with respect to energy, angular momentum, and charge. Definitive results for the signs of these derivatives are found for the repulsive Coulomb case. In particular, we find that the derivative of the shift factor with respect to energy is positive for the repulsive Coulomb case, a long anticipated but heretofore unproven result. In conclusion, these results are closely connected to the properties of the sum of squares of the regular and irregular Coulomb functions; we also present investigations of this quantity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cavity dynamics and particle alignment in the wake of a supersonic projectile penetrating a dusty plasma

The penetration of a projectile into a strongly coupled dusty plasma was studied in a radio-frequency discharge under microgravity conditions. A supersonic projectile produces an elongated dust-free cavity in its wake. The dynamics of the cavity is analyzed and compared with Langevin dynamics simulations. Besides a three-dimensional Mach cone structure, the simulation shows that the cavity dynamics can be subdivided into three phases: An opening phase with fixed time scale, a closing phase, whose duration is affected by the projectile speed and, finally, a phase of particle realignment in the target cloud, which persists for a long time after the closure of the cavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nontrivial Nature and Penetration Depth of Topological Surface States in SmB 6 Thin Films

The nontrivial feature and penetration depth of the topological surface states (TSS) in SmB 6 were studied via spin pumping. The experiments used SmB 6 thin films grown on the bulk magnetic insulator Y 3 Fe 5 O 12 (YIG). Upon the excitation of magnetization precession in the YIG, a spin current is generated in the SmB 6 that produces, via spin--orbit coupling, a lateral electrical voltage in the film. This spin-pumping voltage signal becomes considerably stronger as the temperature decreases from 150 to 10 K, and such an enhancement most likely originates from the spin-momentum locking of the TSS and may thereby serve as evidence for the nontrivial nature of the TSS. The voltage data also show a unique film thickness dependence that suggests a TSS depth of ~32 nm. Finally, the spin--pumping results arc supported by transport measurements and analyses using a tight binding model.

36 MATERIALS SCIENCE↗

Factorization Machine Learning for Disaggregation of Transmission Load Profiles with High Penetration of Behind-the-Meter Solar

The ever-growing high penetration of ubiquitously distributed energy resources, especially behind-the-meter solar (BTM) generations, has significant impacts on nodal load (i.e., net injection) profiles and consequently caused imperative operational challenges to system operators such as regional transmission organizations (RTOs). Illustrated by real-world nodal data and examples at PJM Interconnection, this paper first discusses the application and necessity of effectively extracting daily nodal load profiles in a non-intrusive manner. More importantly, a novel bi-level architecture, including Factorization Machines (FM) learning procedure has been proposed to effectively disaggregate not only one node but every node in an RTO service territory. Specifically, FM leaning is adopted to capture the interconnections between related features to better utilize the correlation between buses in the same region and between a single bus and the zonal load. The proposed bi-level technique is numerically validated using real-world, minute-level, normalized, and anonymized nodal data at PJM service territory.

behind the meter solar, load disaggregation, load ↗

Optimal Size of Energy Storage to Accommodate High Penetration of Renewable Resources in WECC

The variability and intermittence of wind power will cause the large imbalance power that demands more expensive ancillary service. Energy storage, fast response but costly, is a viable solution to suppress the fluctuation of wind power. However, the determination of energy storage is a great challenge given the load demand and wind power uncertainties This paper proposes to use Discrete Fourier Transform (DFT) to decompose the imbalance power into different time-varying components, i.e., intra-week, intra-day, intra-hour and real-time. Therefore, the imbalance power required to be compensated by energy storage can be quantified. By compensating the fast-changing imbalance power (the slowly changing power is provided by the conventional generators), the size of energy storage can be optimized in order to accommodate integration of high penetration of wind power. The simulation results on the 2030 Western Electricity Coordinating Council (WECC) system demonstrate effectiveness and efficiency of this approach.

Makarov, Yuri V.↗

Imaging Modes for Ground Penetrating Radar and Their Relation to Detection Performance

The focus of this paper is an empirical study conducted to determine how imaging modes for ground penetrating radar (GPR) affect buried object detection performance. GPR data was collected repeatedly over lanes whose buried objects were mostly non-metallic. This data was collected and processed with a GPR antenna array, system hardware, and processing software developed by the authors and their colleagues. The system enables GPR data to be collected, imaged, and processed in real-time on a moving vehicle. The images are focused by applying multistatic and synthetic aperture imaging techniques either separately or jointly to signal scans acquired by the GPR antenna array. An image-based detection statistic derived from the ratio of buried object energy in the foreground to energy of soil in the background is proposed. Detection – false alarm performance improved significantly when the detection algorithm was applied to focused multistatic synthetic aperture radar (SAR) images rather than to unfocused GPR signal scans.

47 OTHER INSTRUMENTATION↗

Inertia Estimation Under High Penetration of Inverter-based Resources

Many types of renewable energy sources, especially solar and wind generation, are connected to the electric grid through power-electronic-based interfaces (inverters). These inverter-based resources (IBRs) are mechanically decoupled from the grid, which reduces system inertia and thus may compromise its stability and reliability. In this study, we examine the impact of high penetration of IBRs on the power grid’s inertia. To achieve this, we intentionally introduce disturbances into a simulation case study, such as a step load change, to observe and record the system’s frequency responses. This study offers a nuanced understanding of how the integration of IBRs affects grid stability, and it provides essential guidance for future grid management and resilience strategies.

Yadav, Ajay↗

Reconfigurable Real-Time Power Grid Emulator for Systems With High Penetration of Renewables

Novel power system control and new utility devices need to be tested before their actual deployment to the power grid. To assist with such a testing need, real-time digital emulators such as RTDS and Opal-RT can be used to connect to the physical world and form a hardware in the loop (HIL) emulation. However, due to the limitations of today's computational resources, the accuracy and fidelity suffer from different levels of model reductions in purely digital simulations. CURENT has developed a reconfigurable electric grid hardware testbed (HTB) to overcome the limitations of digital emulators. The HTB has been used to develop measurement, control, modeling, and actuation techniques for a national grid with a high penetration of renewables. The power electronic-based system includes emulators for synchronous generators; photovoltaics with grid-interfacing inverter; wind turbines; induction motor loads, ZIP loads, power electronic loads; batteries; ac and dc transmission lines; short circuit faults and grid relay protection; and a multiterminal HVDC overlay including power electronics interfaces. The system contains real elements of power flow, measurement, communication, protection, and control that mimic what would be seen in an actual electric grid. This paper presents an overview of the HTB and several scenarios that have been run to determine control and actions needed for the future power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Enhanced Hierarchical Control to Improve Distribution Voltage with Extremely High PV Penetration

Dynamic, scalable, and interoperable control paradigms are required to enable efficient, secure, reliable, and resilient distribution grid operations with widespread grid integration of renewable energy resources. This paper presents our recent research on developing a novel, holistic, data-enhanced hierarchical control architecture that addresses the formidable challenges faced by emerging distribution grids with increasing penetrations of distributed energy resources. The proposed architecture integrates centralized monitoring and control with distributed grid-edge control and thus effectively deals with multi-spatiotemporal dynamics existing in the grid. Simulation results are provided to demonstrate the effectiveness of the proposed control architecture.

14 SOLAR ENERGY↗

A Data-Driven Approach to Dynamic Var Compensator Placement for Local Voltage Stabilization on Feeders with High PV Penetration

Distribution feeders with a high penetration of distributed photovoltaic (PV) systems can experience voltage variability caused by the changing load flow injections corresponding to the availability of the solar resource. The rapid, uncontrolled voltage range fluctuations can affect the system. Tap-changing voltage regulators, switched capacitors, and smart inverter functions have been used to stabilize voltage. However, in some cases, when these options are insufficient or unavailable, dedicated reactive power control devices such as dynamic var compensators (DVCs) can be used for local voltage stabilization. This paper introduces a statistical framework to characterize voltage variability and stabilization, proposes a data-driven approach to DVC placement, and presents the results of a planning study on a real feeder using real data.

Reiman, Andrew P.↗

Field Demonstration of Using Advanced PV Inverter Functionality to Mitigate the Impacts of High-Penetration PV Grid Integration on the Distribution System

This paper describes a field demonstration that was completed to show the ability of currently installed PV inverters to implement advanced PV inverter functionality and that such functionality was effective at reducing the voltage-related PV impacts of high-penetration PV integration. A distribution circuit was instrumented and then tested for a two week period using off-unity power factor operation. Specifically, an inductive power factor of -0.95 was demonstrated. The results show that the PV inverters were capable of such operation and that the use of off-unity power factor operation was highly effective at reducing the voltage-related impacts of the PV systems interconnected to the circuits used in the demonstration. The impacts of using off-unity power factor operation - resulting in additional reactive current flow on the distribution circuit - are also presented and analyzed.

14 SOLAR ENERGY↗