Phase-Diverse Coherent Diffractive Imaging: High Sensitivity with Low Dose
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Odd-parity superconductor $\mathrm{UTe_2}$ shows spontaneous time-reversal symmetry breaking and multiple superconducting phases, which imply chiral superconductivity, but only in a subset of samples. Here, we microscopically observe a homogeneous superfluid density $n_s$ on the surface of $\mathrm{UTe_2}$ and an enhanced superconducting transition temperature near the edges. We also detect vortex-antivortex pairs even at zero magnetic field, indicating the existence of a hidden internal field. The temperature dependence of $n_s$, determined independent of sample geometry, does not support point nodes along the $b$ axis for a quasi-2D Fermi surface and provides no evidence for multiple phase transitions in $\mathrm{UTe_2}$.
A new method of constructing ultrasonic images in layered media is proposed that is based on the radiation and reception of plane pulsed waves at various angles. Upon passage via a set of layers, plane pulsed waves do not change their shape and direction in the imaged region, which eliminates the need for detailed analysis of wave propagation in intermediate layers. It is shown that, in the absence of a priori information on the thicknesses and acoustical parameters of layers or the results of their measurement, the proposed method allows images to be obtained at a spatial resolution corresponding to the theoretical limit.
Abstract not provided.
Abstract not provided.
A recommended imaging system is outlined for use aboard the Outer Planet Grand Tour Explorer. The system features the high angular resolution capacity necessary to accommodate large encounter distances, and to satisfy the demand for a reasonable amount of time coverage. Specifications for all components within the system are provided in detail.
A 4.67X, plus or minus 5 deg. compound parabolic concentrator (CPC) for a large photovoltaic array in space was analyzed. The design was demonstrated to be effective in achieving a net power gain which can be varied from more than a factor of 3 down to approximately unity. A method for reducing nonuniformities in illumination to a given desired level was found. The effectiveness of this method, which involves the introduction of a degree of non-specularity in the reflector surface, was confirmed by direct measurements with prepared foil reflectors in a CPC in terrestrial sunshine as well as by computer ray tracing. Further ray tracing confirms that the CPC design is extremely tolerant to pointing and alignment errors, minor distortions, etc. A two stage non-imaging design was shown, by preliminary measurements and analysis, to provide both the desired angular tolerance and the required degree of intensity uniformity if higher concentrations (4X-10X) are necessary.
The determination of interfacial area density in two-phase, gas-liquid flows is one of the major elements impeding significant development of predictive tools based on the two-fluid model. Currently, these models require coupling of liquid and vapor at interfaces using constitutive equations which do not exist in any but the most rudimentary form. Work described herein represents the first step towards the development of Electrical Impedance Computed Tomography (EICT) for nonintrusive determination of interfacial structure and evolution in such flows.
No abstract available
No abstract provided
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Bi-component protection-systems need to withstand a variety of extreme loading conditions such as high-velocity projectile impact to shock and blast mitigation. The large number of parameters at each stage of bi-component protection system design process results in a near-infinite number of possible variables for optimization. The aim of this project is to identify the scaling laws linking material and geometric scales of the problem to the final impact performance, further including the effects of wave propagation/interaction and inter-component bonding. Specifically, the impact dynamics for different optimal projectile/target density ratios and relative component mass fractions are quantified for bonded ceramic/titanium alloy systems. The impact behavior such as wave mechanics and damage propagation within the target system is characterized and quantified via digital image correlation or via x-ray phase-contrast imaging.
In this paper, the beam-steering characteristics of photoconductive dipole phased array antenna configuration at 1.95 THz is presented. The proposed array antenna configuration with frequency selective surface favourably improves its gain and directivity which is useful to upsurge the imaging capabilities to address the deliberations such as limited depth-of-field (DoF) and size-weight-and-power of the THz source for imaging applications. These are important considerations for applications like stand-off imaging and surveillance of moving targets where the high angular resolution as well as extended DoF are the important parameters for successful detection of concealed explosives. The projected planar profile and compact highly directive (2×2) small-gap photoconductive dipole phased array antenna can be castoff for the exposure of concealed explosives such as RDX, TNT, and HMX which illustrate their substantial spectral absorption fingerprints in terahertz (1.4–2.2 THz) regime of the spectrum. A simple method of beam-steering has been explored based on phase controlled optical excitation of highly directive small-gap photoconductive dipole array antenna. Further, the effects of uniform progressive phase shift on the beam-steering of uniform linear array (along x-axis) as well as planar array (x-axis and y-axis) is investigated.
This article illustrates the phase contrast instrumentation installed at the Tomographic Microscopy and Coherent Radiology beamline (TOMCAT) of the Swiss Light Source. Our experimental framework has been designed to extract phase information at spatial resolutions covering three orders of magnitude. For moderate (5-10 microns) resolutions we implemented a two-gratings interferometer, operated at energies between 14 and 40 keV. For high resolution (1-5 microns) we obtain phase information thanks to a modified transport of intensity approach. For very high-resolutions (0.1-0.5 microns) we developed a broadband hard X-ray full-field microscope operated in Zernike-phase contrast.
Optical imaging of fast and transient phenomena such as the turbulent breakup of liquid sprays exhibit low signal-to-noise ratios due to the limited illumination intensity relative to the short exposure time. Image denoising is required to facilitate physical studies over these data but is challenging due to the absence of clean ground-truths and the stringency of the denoising task (e.g., strong and complex noise, limited resolution, preserving physical fidelity), preventing supervised and existing un-/self-supervised deep learning methods. To this end, Sequence2Self (Seq2S) is proposed, an extension of Self2Self (S2S) to image sequences that leverages both the signal’s spatial and temporal correlation. Seq2S is demonstrated on time-resolved x-ray phase contrast imaging of liquid jet fuel sprays in a gas turbine combustor, which possesses all of challenges detailed above. Experiments are conducted across four fuels with different breakup morphology using various state-of-the-art methods. Overall, many of the methods failed and Seq2S was most successful: (1) Accurate spray structures were reconstructed with consistent evolution across frames void of artifacts. (2) The performance was robust, invariant to the hyperparameter choice. (3) Computational time is short and can be made eligible for real-time denoising. In particular, the images denoised by Seq2S showed spray droplet diameter distributions with near-zero Kullback–Leibler divergence (0.01 ± 0.01) to a cleaner reference, whereas the second best method yielded 0.06 ± 0.03. In conclusion, this suggests that Seq2S can be reliably used prior to subsequent quantitative spray analyses as it retains (if not, improves) the statistical physical properties of the data.
Purpose: Four-dimensional cone-beam computed tomography (4D CBCT) has been investigated for motion imaging in the radiotherapy treatment room. The drawbacks of 4D CBCT are long scan times and high imaging doses. The aims of this study were to develop and investigate a slow gantry rotation acquisition protocol for four-dimensional digital tomosynthesis (4D DTS) as a faster, lower dose alternative to 4D CBCT. Methods: This technique was implemented using an On-Board Imager kV imaging system (Varian Medical Systems, Palo Alto, CA) mounted on the gantry of a linear accelerator. The general procedure for 4D DTS imaging using slow gantry rotation acquisition consists of the following steps: (1) acquire projections over a limited gantry rotation angle in a single motion with constant frame rate and gantry rotation speed; (2) generate a respiratory signal and temporally match projection images with appropriate points from the respiratory signal; (3) use the respiratory signal to assign phases to each of the projection images; (4) sort projection images into phase bins; and (5) reconstruct phase images. Phantom studies were conducted to validate theoretically derived relationships between acquisition and respiratory parameters. Optimization of acquisition parameters was then conducted by simulating lung scans using patient data. Lung tumors with approximate volumes ranging from 0.12 to 1.53 cm{sup 3} were studied. Results: A protocol for slow gantry rotation 4D DTS was presented. Equations were derived to express relationships between acquisition parameters (frame rate, phase window, and angular intervals between projections), respiratory cycle durations, and resulting acquisition times and numbers of projections. The phantom studies validated the relationships, and the patient studies resulted in determinations of appropriate acquisition parameters. The phase window must be set according to clinical goals. For 10% phase windows, we found that appropriate frame rates ranging from 2 to 5 frames/s, gantry rotation speeds ranging from 0.44 to 1.03 deg./s, and aiming for an approximate maximum angular interval of 3.4 deg. between projections in phase bins were appropriate for dose, scan time, and tumor visibility optimization. Adequate tumor visibility was achieved for coronal 4D DTS images of all three lung tumors with acquisition times ranging from 0.45 to 2.12 min. vs 1.84 to 4.24 min for 4D CBCT. 4D DTS imaging doses ranged from 0.12 to 0.72 times the dose of a standard CBCT scan vs 0.48 to 1.44 times the dose of a standard CBCT scan for 4D CBCT. Conclusions: A slow gantry rotation acquisition technique for 4D DTS was developed and investigated. Study results indicated that 4D DTS is a feasible technique for imaging lung tumor motion in the treatment room and requires shorter acquisition times and less imaging dose than 4D CBCT for larger tumors that do not require large scan angles for sagittal views and for situations where only coronal views are needed to meet clinical needs.